• 제목/요약/키워드: Thevenin model

검색결과 15건 처리시간 0.02초

A Simplified Li-ion Battery SOC Estimating Method

  • Zhang, Xiaoqiang;Wang, Xiaocheng;Zhang, Weiping;Lei, Geyang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권1호
    • /
    • pp.13-17
    • /
    • 2016
  • The ampere-hour integral method and the open circuit voltage method are integrated via the extended Kalman filter method so as to overcome insufficiencies of the ampere-hour integral method and the open circuit voltage method for estimating battery SOC. The process noise covariance and the measurement noise covariance of the extended Kalman filter method are simplified based on the Thevenin equivalent circuit model, with a proposed simplified SOC estimating method. Verification of DST experiments indicated that the battery SOC estimating method is simple and feasible, and the estimated SOC error is no larger than 2%.

DISCUSSION ABOUT HBS TRANSFORMATION IN HIGH BURN-UP FUELS

  • Baron, Daniel;Kinoshita, Motoyasu;Thevenin, Philippe;Largenton, Rodrigue
    • Nuclear Engineering and Technology
    • /
    • 제41권2호
    • /
    • pp.199-214
    • /
    • 2009
  • High burn-up transformation process in low temperature nuclear fuel oxides material was observed in the early sixties in LWR $UO_2$ fuels, but not studied in depth. Increasing progressively the fuel discharge burn-up in PWR power plants, this material transformation was again observed in 1985 and identified as an important process to be accounted for in the fuel simulations due to its expected consequence on fuel heat transfer and therefore on the fission gas release. Fission gas release was one of the major concerns in PWR fuels, mainly during transient or accidents events. The behaviour of such a material in case of rod failure was also an important aspect to analyse. Therefore several national and international programs were launched during the last 25 years to understand the mechanisms leading to the high burn-up structure formation and to evaluate the physical properties of the final material. A large observations database has been acquired, using the more sophisticated techniques available in hot cells. This large database is discussed in this paper, providing basis to build an engineering-model, which is based on phenomenological description data and information accumulated. In addition this paper has the ambition to construct the best logical model to understand restructuring.

비정형적 배터리 특성을 포함한 배터리 시뮬레이터의 구현 (The Implementation of a Battery Simulator with Atypical Characteristics of Batteries)

  • 이동성;이성원
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제3권11호
    • /
    • pp.419-426
    • /
    • 2014
  • 최근 스마트 모바일 기기에서의 고성능화 추세는 더 많은 소비 전력을 요구하게 되어 배터리 사용 시간의 감소로 이어지고 있다. 이에 배터리 관리의 중요성과 그 연구에 필요한 정확한 배터리 모델링 방법이 중요해지고 있다. 배터리 모델은 크게 수학적 모델, 전기화학적 모델, 전기적 모델로 구분된다. 그중 전기적 모델에서 전기적 소자를 사용한 테브닌 등가회로와 SOC의 비선형 함수 모델을 사용하는 것이 일반적이나, 온도나 사용연한에 따른 특성 변화, 전기적 소자로 표현할 수 없는 비정형적 저항성분 등의 존재로 OCV 결과 출력의 정확성에 한계가 존재한다. 본 논문에서는 기존의 모델의 정확성을 향상시키기 위하여 배터리의 SOC 특성을 나타내는 수학적 함수 모델을 개선하고 온도, 수명, 그리고 전기적 특성의 비선형성을 포함하는 새로운 배터리 모델을 제안한다. 또한 제안한 모델을 구현한 시뮬레이터를 사용하여 정적 전류 상태와 동적 전류 상태에서의 배터리의 방전 결과를 예측한 결과, 기존 방법 대비 실측값과의 MSE가 개선된 결과를 보였다.

그래프법을 이용한 안전기준에 의한 감전위험성 평가 (An Assessment of Electric Shock Hazard by Safety Criteria Using Graphical Method)

  • 김두현;강동규
    • 한국안전학회지
    • /
    • 제16권3호
    • /
    • pp.53-60
    • /
    • 2001
  • This paper presents a graphical method for hazard assessment of electric shock by safety criteria. For the human body to be safety actual body current should not exceed safety criteria, i.e. allowable body current. The assessment method presented in this paper is based m the safety criteria of the IEEE Standard 80 as well as the IEC 479-1. The hazard can be assessed in terms of alterable touch voltages instead of alterable body current. Thus, the hazard assessment of given electric shock condition is referred to a procedure by which the actual touch voltages are compared with the allowable (safe) touch voltages. Since the IEC 479-1 safety criteria are nonlinear, the graphical method is presented for the hazard assessment. Body current and body voltage are calculated with the allowable touch voltage. A comparison of the safety criteria of two widely accepted standards, i.e. the IEEE Std 80 End the IEC 479-1 is proposed. Also Thevenin equivalent resistance is obtained from electric shock model expressed by two-port earth-grid-foot system. On the basis of calculated results, the allowable touch voltage, the body current and the body voltage we can conduct the hazard or safety assessment and estimate the severity of electric shock.

  • PDF

전자기 과도현상 해석을 위한 S 영역 등가시스템 PART I : 주파수 의존 시스템 등가 (S-Domain Equivalent System for Electromagnetic Transient Studies PART I : Frequency Dependent Network Equivalent)

  • 왕용필
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권11호
    • /
    • pp.632-638
    • /
    • 2003
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of frequency dependent equivalent. The s-domain rational function form of frequency dependent equivalent does not need refitting if the simulation time-step is changed in the electromagnetic transient program. This is because the s-domain rational function coefficients are independent of the simulation time-step, unlike the z-domain rational function coefficients. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper Presents the formulation for developing 1 Port Frequency Dependent Network Equivalent(FDNE) with the instantaneous term in S-domain and illustrates its use. This 1 port FDNE have been applied to the CIGRE Benchmark Rectifier test AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 port (FDNE) developed with Thevenin and Norton Equivalent network. The study results have indicated the robustness and accuracy of 1 port FDNE for electromagnetic transient studies.