• Title/Summary/Keyword: Thevenin model

Search Result 15, Processing Time 0.019 seconds

A Simplified Li-ion Battery SOC Estimating Method

  • Zhang, Xiaoqiang;Wang, Xiaocheng;Zhang, Weiping;Lei, Geyang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • The ampere-hour integral method and the open circuit voltage method are integrated via the extended Kalman filter method so as to overcome insufficiencies of the ampere-hour integral method and the open circuit voltage method for estimating battery SOC. The process noise covariance and the measurement noise covariance of the extended Kalman filter method are simplified based on the Thevenin equivalent circuit model, with a proposed simplified SOC estimating method. Verification of DST experiments indicated that the battery SOC estimating method is simple and feasible, and the estimated SOC error is no larger than 2%.

DISCUSSION ABOUT HBS TRANSFORMATION IN HIGH BURN-UP FUELS

  • Baron, Daniel;Kinoshita, Motoyasu;Thevenin, Philippe;Largenton, Rodrigue
    • Nuclear Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.199-214
    • /
    • 2009
  • High burn-up transformation process in low temperature nuclear fuel oxides material was observed in the early sixties in LWR $UO_2$ fuels, but not studied in depth. Increasing progressively the fuel discharge burn-up in PWR power plants, this material transformation was again observed in 1985 and identified as an important process to be accounted for in the fuel simulations due to its expected consequence on fuel heat transfer and therefore on the fission gas release. Fission gas release was one of the major concerns in PWR fuels, mainly during transient or accidents events. The behaviour of such a material in case of rod failure was also an important aspect to analyse. Therefore several national and international programs were launched during the last 25 years to understand the mechanisms leading to the high burn-up structure formation and to evaluate the physical properties of the final material. A large observations database has been acquired, using the more sophisticated techniques available in hot cells. This large database is discussed in this paper, providing basis to build an engineering-model, which is based on phenomenological description data and information accumulated. In addition this paper has the ambition to construct the best logical model to understand restructuring.

The Implementation of a Battery Simulator with Atypical Characteristics of Batteries (비정형적 배터리 특성을 포함한 배터리 시뮬레이터의 구현)

  • Lee, Dong Sung;Lee, Seong-Won
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.11
    • /
    • pp.419-426
    • /
    • 2014
  • The recent trend of performance increase in the smart mobile devices demands more power consumption and lower batter life time. Among three battery models of mathematical model, electrochemical model and electric model, the Thevenin's equivalent circuit with non-linear function model of SOC in the electrical model is widely used. However, the OCV results have only limited accuracy because of the characteristic shift caused by temperature and age and atypical impedance property that cannot expressed by electrical components. In this paper, the new battery model that improves the accuracy of the existing models is proposed. In the proposed simulator the mathematical model for SOC characteristic is improved and the adjustment for the temperature, the age of battery and atypical electrical characteristics. In the experimental results of predicting of the battery in the static and dynamic state, the proposed simulator shows improved MSE comparing to the results of the existing methods.

An Assessment of Electric Shock Hazard by Safety Criteria Using Graphical Method (그래프법을 이용한 안전기준에 의한 감전위험성 평가)

  • 김두현;강동규
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.53-60
    • /
    • 2001
  • This paper presents a graphical method for hazard assessment of electric shock by safety criteria. For the human body to be safety actual body current should not exceed safety criteria, i.e. allowable body current. The assessment method presented in this paper is based m the safety criteria of the IEEE Standard 80 as well as the IEC 479-1. The hazard can be assessed in terms of alterable touch voltages instead of alterable body current. Thus, the hazard assessment of given electric shock condition is referred to a procedure by which the actual touch voltages are compared with the allowable (safe) touch voltages. Since the IEC 479-1 safety criteria are nonlinear, the graphical method is presented for the hazard assessment. Body current and body voltage are calculated with the allowable touch voltage. A comparison of the safety criteria of two widely accepted standards, i.e. the IEEE Std 80 End the IEC 479-1 is proposed. Also Thevenin equivalent resistance is obtained from electric shock model expressed by two-port earth-grid-foot system. On the basis of calculated results, the allowable touch voltage, the body current and the body voltage we can conduct the hazard or safety assessment and estimate the severity of electric shock.

  • PDF

S-Domain Equivalent System for Electromagnetic Transient Studies PART I : Frequency Dependent Network Equivalent (전자기 과도현상 해석을 위한 S 영역 등가시스템 PART I : 주파수 의존 시스템 등가)

  • 왕용필
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.11
    • /
    • pp.632-638
    • /
    • 2003
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of frequency dependent equivalent. The s-domain rational function form of frequency dependent equivalent does not need refitting if the simulation time-step is changed in the electromagnetic transient program. This is because the s-domain rational function coefficients are independent of the simulation time-step, unlike the z-domain rational function coefficients. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper Presents the formulation for developing 1 Port Frequency Dependent Network Equivalent(FDNE) with the instantaneous term in S-domain and illustrates its use. This 1 port FDNE have been applied to the CIGRE Benchmark Rectifier test AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 port (FDNE) developed with Thevenin and Norton Equivalent network. The study results have indicated the robustness and accuracy of 1 port FDNE for electromagnetic transient studies.