• Title/Summary/Keyword: Thermostatic System

Search Result 30, Processing Time 0.027 seconds

Simulation Study for Control Strategies of Indoor Air Temperature in Floor Radiant Heating System (바닥 복사난방 시스템의 실내온도 제어방안에 관한 시뮬레이션 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.21-26
    • /
    • 2016
  • In this study, the control strategies of indoor air temperature in floor radiant heating system were researched by computer simulation. The temperature difference based time control method using the difference of indoor set temperature and indoor temperature is compared with the existing On-Off control one for heating control performances. As a result, the temperature difference based time control method shows better thermal environmental characteristics in case of selected operational conditions in comparison with existing control one.

Thermal Energy Recovery from Waste Heat of an I.C. Engine for Agriculture(II) -System Simulation and Stability Test- (농용(農用) 내연기관(內燃機關) 폐열(廢熱)의 열(熱)에너지 회수(回收)(II) -시스템 Simulation과 안정성(安定性) 실험(實驗)-)

  • Suh, S.R.;Yoo, S.N.
    • Journal of Biosystems Engineering
    • /
    • v.12 no.1
    • /
    • pp.6-13
    • /
    • 1987
  • A mathematical model for the waste heat recovery system for an engine was developed. The model based on the experimental data reported before was validated and was used to predict the waste heat recovery and recoverable heat of the engine at various operating conditions of the engine and the system. The model was also used to determine flow rates of the circulating water in the system for a certain temperature increment of the water at various operating conditions of the engine to give basic data to design the system. Stability of the system performance was tested on subjects of vapor lock problem, thermal characteristics of the thermostatic valve, and temperature variation of the circulating water in the engine and fuel consumption of the engine during each mode of the system operation and its change into the other. The test showed that the system operation was stable enough. Temperature profile in the thermal energy storage (TES) was observed during storing thermal energy, and thermal stratification in the TES was well formed acceptable to be used in the system. Finally a scheme to automatize the system was suggested.

  • PDF

Study on Control of Refrigerant Flow Rate and Characteristics of Superheat in Evaporator using Electronic Expansion Valve (전자(電子) 팽창밸브를 이용(利用)한 증발기(蒸發器)의 냉매(冷媒) 流量(유량) 제어(制御) 및 과열도(過熱度) 특성(特性)에 관한 연구(硏究))

  • Choi, S.O.;Kim, J.H.;Yang, H.S.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.380-387
    • /
    • 1994
  • An experimental study was performed to investigate the characteristics of refrigerant flow rate control and superheat in an evaporator with an electronic expansion valve(EEV). The EEV used in this study was devised using a needle valve coupled with a stepping motor controlled by a personal computer. A Pill control equation was used to control the superheat of the evaporator and to set the superheat to $5^{\circ}C$. In order to determine an optimum running condition for the system, Pill parameters were varied for the wide range of values. The running condition of an air conditioning system with a PI control was reasonably stable compared with that of the Pill control. Experimental results for the PI control using parameter values, $K_p=1.5$, $T_i=400(sec)$ and $T_s=6(sec)$ show that the superheat reached its target value. When external disturbances were introduced to the system, the superheat target value was reached within about 3 minutes. When the EEV was applied to the air conditioning system driven by an inverter, room temperature control was excellent.

  • PDF

Internal communication as CCTV Automatic Climate Control System Development (CCTV통신용 함체내의 항온항습 자동제어 장치 개발)

  • Kim, Hee-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.433-439
    • /
    • 2015
  • Enclosures for CCTV internal short circuit are prevented due to wetting to maintain a constant humidity and temperature, to avoid condensation due to temperature difference, a constant temperature and humidity requirements of the equipment, such as high-temperature resistant and a constant temperature of the structure, degree of energy utilization is optimized for developing this corresponding housing automatic control system and humidity is required. Device being an expensive imaging equipment in side of the enclosure according to the temperature conversion from a hazard protection, there is a need for a constant temperature and humidity control apparatus that can prevent a short-circuit failure. This is a system in which the accessory device is absolutely required for the storage and transmission of an image in recording reliability and field conditions.

Capacity Modulation of an Inverter Driven Heat Pump with Expansion Devices

  • Lee, Yong-Taek;Kim, Yong-Chan;Park, Youn-Cheol;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.2
    • /
    • pp.60-68
    • /
    • 2000
  • An experimental study was peformed to investigate characteristics of an inverter driven heat pump system with a variation of compressor frequency and expansion device. The compressor frequency varied from 30Hz to 75Hz, and the performance of the system ap-plying three different expansion devices such as capillary tube, thermostatic expansion valve(TXV), and electronic expansion valve (EEV) was measured. The load conditions were altered by varying the temperatures of the secondary fluid entering condenser and evaporator with a constant flow rate. When the test condition was deviated from the standard value(rated value), TXV and EEV showed better performance than capillary tube due to optimal control of mass flow rate and superheat. In the present study, it was observed that the variable area expansion device had better performance than constant area expansion device in the inverter heat pump system due to active control of flow area with a change of com-pressor frequency and load conditions.

  • PDF

Design and Implementation of a Monitor Checking the Execution Time of Real-time Object-oriented Programs (실시간 객체지향 프로그램의 실행시간을 감시하는 모니터의 설계 및 구현)

  • Min, Byoung-Joon;Choi, Jae-Young;Kim, Jung-Guk;Kim, Moon-Hae
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.12
    • /
    • pp.3804-3814
    • /
    • 2000
  • This paper presents an efficient implementation of a run-time monitor which checks the satisfaction of the timing constraints of real-time object-oriented programs based on a real-time object model called TMO(Time-triggered Messagedtriggered Object). An execution environment of TMO programs on Windows as, WTMOS(Windows TMO System) has been utilized for the implementation and an experimental application for thermostatic control has been developed to analyze the performance of the run-time monitor. We suggest a methodology for application programmers to specify the target methods with the monitoring conditions and an implementation technique which incurs the small cost by effectively distributing the functions of the monitor into the WTMOS and a TMO object.

  • PDF

The Phase Behavior of Nonionic Surfactants having Sucrose as Hydrophilic Group(II) - The Phase Behavior of Sucrose Monopalmitate/Alkanol/Water System - (당류를 친수기로 한 비이온성 계면활성제계의 상거동(제2보) - 슈크로오스 팔미테이트/알칸올/물 계에서의 상거동 -)

  • Lee, Hyang-Woo;Lee, Jin-Hee;Nam, Ki-Dae
    • Applied Chemistry for Engineering
    • /
    • v.8 no.2
    • /
    • pp.246-251
    • /
    • 1997
  • The phase behavior of sucrose monopalmitate/alkanol/water ternary system was investigated. According to compositions of three components ranging from micellar(or inverse micellar) solution up to various lyotropic liquid crystalline(LC) phase, each texture of the separated phases was identified by crossed polarizers equipped with a camera whose stage was connected to a thermostatic circulator. As the carbon atom number in alkanol of the polar oily substance increases, patterns of the various LC phases were also observed hexanol

  • PDF

A study of Fiber-Optic Voltage Sensor in a distribution automated switch (배전자동화 개폐기에서 광전압센서에 관한 연구)

  • 오상기;김요희;서승현;이희철;양승국
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.493-496
    • /
    • 2000
  • This study is about the design and fabrication of optical voltage sensor modules improved in the insulation reliability, where we adopted the space-division voltage system using the auxiliary electrodes to apply the uniform electric fields to the BSO, the device of which the polarization state varies with the variation of refractive index in the electric fields. We measured the output of fiber-Optic Voltage Sensors with the temperature changes in the thermostatic oven. And we measured the output of Fiber-Optic Voltage Sensors after setting its up in the disttibuion automated switch being apply 60Hz alternating voltage from 6.6kV to 17.BkV. In result, measured error characteristic is good, so we can judge it is applicable to the practical case

  • PDF

A Basic Study on Efficient Acrylic Plate Light Transmission Road Machining (효율적인 아크릴판 광전송로 가공에 관한 기초 연구)

  • Han, Su-Won;Hong, Jun-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.1
    • /
    • pp.95-101
    • /
    • 2022
  • This paper proposes a method to process the shape of an optical transmission road and attempts to determine the most suitable single processing method for an acrylic plate optical transmission road. In addition, by manufacturing an automatic pattern processing device to generate certain shapes on the acrylic plate at regular intervals, and measuring the illuminance of the patterned acrylic plate optical transmission road, the measured illuminance was confirmed to fall under the KS illuminance values presented in Table 1. In conclusion, when an incident light of approximately 20,000 lx is applied, the transmission illumination is approximately 200 lx, which represents a transmission rate of approximately 1% for incident light and corresponds to the KS illumination criterion F. Additionally, the right-angle triangular pyramid base size (A) processed at a temperature of 350 ℃ for one second was 2 mm, exhibiting the largest transmission illumination of 280 lx. When the transparent acrylic plate was set to a constant size of 1.6 mm at the bottom of the right-angle triangular pyramid, the fastest response occurred at a processing tip temperature of 350 ℃ (0.04 s). On the other hand, it took 10 s to process the size of the bottom of the right-angled triangular pyramid at a temperature of 200 ℃ to 1.6 mm, and it was confirmed that the optical transmission efficiency was significantly reduced because of the burr that occurred at this time.

Experimental Studies on Heat Conductivity of Human Bone and Torsional Strength of Pasteurized Porcine Tibia (생체골의 열전도성 및 열처리된 골의 염전력 변화에 대한 실험적 연구)

  • Park, Il-Hyung;Kim, Sin-Gun;Shin, Dong-Kyu;Ihn, Joo-Chul
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.1
    • /
    • pp.7-16
    • /
    • 1995
  • In countries where confucianism is popular, it is extremely hard to get fresh cadaver bone for allograft. Therefore in Korea, the reimplantation of resected autoclaved autogenous bone segments has been increasingly performed for limb reconstruction of extremities with malignancies. To preserve the bone morphogenetic protein and mechanical strength of heated bone, many studies have reported that pasteurization of bone is far better than autoclaving over $100^{\circ}C$. Based on this assumption, replacement with a pasteurized autogenous bone graft after resection of a malignant bone tumor was deemed feasible for reconstruction. However, little is known about how high a temperature and how much time for pasteurization is needed to make tumors completely necrotic and to maintain the mechanical strength of bone. Consequantly, experimental studies were carried out to test heat conductivity of human bone and torsional strength of porcine tibia after pasteurization. First, two pairs of human proximal tibia and distal femur were used. We used T-type thermocoples to check core temperature of the bone and a computerized data acquisition system to record results. Without reaming of the medullary cavity, in a $60^{\circ}C$-thermostatic saline tub, it took 32 minutes and 50 seconds to raise the core temperature of human proximal tibia from $20^{\circ}C$ to $58^{\circ}C$, and 30 minutes for distal femur. In a $80^{\circ}C$ saline tub, it took 12 minutes and 50 seconds for proximal tibia, and 11 minutes and 10 seconds for distal femur. In contrast, using porcine tibia whose cortical thickness is similar to that of human tibia, after reaming of the medullary canal, it took less than 3 minutes and 30 seconds in a $60^{\circ}C$ saline tub, less than 1 minute and 45 seconds in a $70^{\circ}C$ tub, and less than 1 minute in a $80^{\circ}C$ tub to elevate core temperature from $20^{\circ}C$ to $58^{\circ}C$. Second, based on data of the heat conductivity test, we compared the torsional strength before and after pasteurization. Twenty matched pairs of porcine tibia were used, The left one was used as a non-heated control group and the right one as a pasteurized experimental group. Wighout reaming of the medullary cavity, there was no statistical difference in torsional strength between the pasteurization of the $60^{\circ}C$-35minute and of $80^{\circ}C$-15minute. With reaming, we also found no statistical difference among pasteurization of $60^{\circ}C$-15 minute, of $70^{\circ}C$-15 minute, and of $80^{\circ}C$-15 minute groups. In conclusion, reaming of the medullary canal is very helpful in saving pasteurization time. And, in a $60^{\circ}C$ saline tub, no significant weakness in torsional strength occurs with pasteurization of the bone for up to 35 minutes. Also no significant weakness in torsional strength occurs with an exposure of 15 minutes to the $80^{\circ}C$ saline tub.

  • PDF