• 제목/요약/키워드: Thermocouples

검색결과 265건 처리시간 0.024초

막응축 열전달에서 공기-수증기 혼합기체의 속도 및 온도분포 (Velocity and Temperature Profiles of Steam-Air Mixture on the Film Condensation)

  • 강희찬;김무환
    • 대한기계학회논문집
    • /
    • 제18권10호
    • /
    • pp.2675-2685
    • /
    • 1994
  • A study has been conducted to provide the experimental information for the velocity and temperature profiles of steam-air mixutre and to investigate their roles on the film condensation with wavy interface. Saturated gas mixture of steam-air was made to flow through the nearly horizontal$(4.1^{\circ})$ square duct of 0.1m width and 1.56m length at atmospheric pressure, and was condensated on the bottom cold plate. The air mass fraction in the gas mixture was changed from zero(W =0, pure steam) to one(W =1, pure air), and the bulk velocity was varied from 2 to 4 m/s. Water film was injected concurrently to investigate the effect of wavy interface on the condensation. The velocity and temperature profiles were measured by LDA system and thermocouples along the three parameters ; air mass fraction, mixture velocity and film flow rate. The profiles moved toward the interface with increasing steam mass fraction, mixture velocity and film flow rate. The Prandtl and Schmidt numbers were near one in the present experimental range, however there was no complete similarity between the velocity and temperature profiles of gas mixture. And the heat transfer characteristics and interfacial structure were coupled with each other.

UV 나노임프린트리소그래피의 정렬 공정 중 몰드의 변형해석 (Deformation of a mold for large area UV-nanoimprint lithography in alignment and curing processes)

  • 박인수;원종진;임홍재;정재일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1939-1943
    • /
    • 2008
  • Deformation of a mold is measured and analyzed in alignment and curing processes of UV-Imprint Lithography. We are focused on mold deformation caused by a UV resin, which is laminated between a mold and a target glass-panel. The UV resin is viscous in case of liquid state, and the resin will be solidified when being exposed by the ultra-violet light. The viscosity of the resin causes shear force on the mold during the alignment process. Moreover, the shrinkage during phase change from liquid to solid may cause residual stress on the mold. The experiments for measuring temperature and strain are made during alignment and curing process. Strain-gages and thermocouples are used for measuring the strain and variation of temperature on several points of the mold, respectively. The deformation of mold is also simulated and analyzed. The simulation results are compared with the experiments. Finally, sources of alignment errors in large area UV-nanoimprint lithography are discussed.

  • PDF

고온 나노임프린트 장비용 핫플레이트의 열제어에 대한 수치모사 (NUMERICAL SIMULATION OF THERMAL CONTROL OF A HOT PLATE FOR THERMAL NANOIMPRINT LITHOGRAPHY MACHINES)

  • 박규진;곽호상;신동원;이재종
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 춘계 학술대회논문집
    • /
    • pp.153-158
    • /
    • 2007
  • Since the introduction of Nanoimprint in the mid-1990s, Nanoimprint lithography, a low-cost, non-convential method, has been the dominant lithography technology that guarantees high-throughput patterning of nanostructures. Based on the mechanical embossing mechanism, Nanoimprint lithography creates the nanopatterns on the polymer material cast on the substrate. In essence, the process needs nanofabrication equipment for printing with the adequate control of temperature, pressure and control of parallels of the stamp and substrate. This article introduce the possibility and reality of the thermal control on the hot plate using a CFD code. Numerical computation has been conducted for assessing the feasibility of a hot plate($120{\times}120\;mm2$). PID control is adopted to ensure high temperature uniformity in several zones. Parallel experiments have also been performed for verifying thermal performance. Not only show the results the optimum number of thermocouples related to controllers but also suggest that the thermal simulation using a CFD code would be an alternative method to design and develop the thermal control equipment in the financial aspect.

  • PDF

분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향 (Effects of Spray Characteristics of Water Mist on The Extinction of a Liquid Pool Fire)

  • 김호영;오상엽;정진택
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1591-1599
    • /
    • 2004
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is a small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is l15∼180${\mu}{\textrm}{m}$ with nozzle A and 130∼190${\mu}{\textrm}{m}$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of $O_2$ concentration.

미분무수 분무특성이 액체연료 Pool 화염의 소화에 미치는 영향 (The Effects of Spray Characteristics of Water Mist on the Fire Suppression of Liquid Pool Fire)

  • 오상엽;김호영;정진택
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.215-221
    • /
    • 2003
  • A series of experiments were conducted to study the effectiveness of the extinction of a liquid pool fire with two different water atomizing nozzles. Fire source is small-scale circular stainless steel pan of 120mm in diameter with the fuels of hexane and ethanol. K-type thermocouples were used to measure the flame and fuel temperature along the pool centerline and under fuel surface. A digital camera was used to visualize the process of the fire suppression. The experimental results show that water mist droplet size is $115{\sim}180{\mu}m$ with nozzle A and $130{\sim}190{\mu}m$ with nozzle B. The extinguishing time of pool fire was reduced with the increase of pressure. When water droplets are small, they do not reach the flame base since they may be deflected or evaporated by the fire plume. However, influence of flow rate is more important than droplet size on fire extinction. Among the fire extinction mechanisms, drop of flame temperature is superior to suffocation of O2 concentration.

  • PDF

비예혼합 대향류화염의 구조와 소화 (Structure and Suppression of Nonpremixed Counterflow Flames)

  • Anthony Hamins;Park, Woe-Chul
    • 한국화재소방학회논문지
    • /
    • 제17권3호
    • /
    • pp.20-25
    • /
    • 2003
  • 화염변형률과 소화약제의 첨가 및 부력이 비예혼합 대향류 화염의 구조와 소화에 미치는 영향을 조사하기 위해 필라멘트와 열전대를 이용한 실험과 Oppdif 및 FDS를 사용한 수치해석을 수행하였다. 소화농도에 가까운 메탄-공기의 확산화염에 대하여 2.2초의 무중력 낙하실험과 정상중력에서의 측정결과를 수치모사의 결과와 비교하였다. 변형률 7 s$^{-1}$에서 100 s$^{-1}$까지 무중력상태에서 측정한 임계소화농도로부터 질소의 임계소화농도에 최대치가 있음을 확인하였다. 또한, 부력의 효과, 즉, 화염의 곡률과 두께 변화를 FDS의 계산결과로 확인하였다. 무중력상태에서 화염의 최고온도와 그 위치에 대한 실험치와 계산값이 일치함을 알 수 있었다.

고층건물의 수직방향 연기거동에 미치는 발코니의 영향에 관한 실험적 연구 (An Experimental Study on the Effect of the Balcony on the Vertical Smoke Movement of the High Rise Building)

  • 양승신;김성찬;유홍선;심상훈
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.42-48
    • /
    • 2005
  • The present study investigates the effect of balcony on external smoke movement of high rise building through the fire tests of the 1/10 reduced model scale using Froude scaling. A hexane pool fire is used to examine the smoke movement for various opening sizes of balcony and temperature distributions are measured by T-type thermocouples. Also, hydrogen bubble technique is applied to visualize the smoke movement near the balcony. Measured temperatures of the closed balcony is 2.5 times higher than those of the open balcony because the external smoke in case of the closed balcony rise along the vertical wall. The maximum vertical temperature of partially closed balcony is similar with fully closed balcony and mean temperature inside of balcony increases as opening size of balcony decreases. The experimental results show that the balcony space plays an important roles in preventing fire propagation and cooling of smoke layer. In order to ensure the fire safety in high rise building design, a series of systematic researches are required to examine the various type of balconies.

폴리머 2D 캠버 보상을 위한 레이저용접 기술 (A Study of Laser Joining for Polymer 2D Camber Compensation)

  • 이영민;윤진영;송치훈;최해운
    • 한국레이저가공학회지
    • /
    • 제15권2호
    • /
    • pp.15-20
    • /
    • 2012
  • A novel joining technology was developed to compensate the camber in polymers. The preheating laser beam circulates on the joining location and the accumulated heat serves to increase the flexibility of neighboring polymers. The temperature rises up to the glass transient temperature of the polymers and continually loading spring force closes the gap of camber. The irradiated laser was 808nm central wavelength and the power varied between 2Watt and 5Watt. The laps were adjusted between 3 and 10 and the optimum process parameters were 3Watt and 5 laps for the specific application. An FEM analysis was introduced to understand the mechanism of joining by the transient temperature distribution on the polymers. Thermocouples experiments were also tried to correlate the numerical analysis results and it showed the trend of heat accumulation in experiments.

  • PDF

상온 능동형 자기 재생 냉동기의 개발 (Development of the active magnetic regenerative refrigerator for room temperature application)

  • 박인명;김영권;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.60-64
    • /
    • 2012
  • In this paper, an investigation of a room temperature active magnetic regenerative refrigerator is carried out. Experimental apparatus includes two active magnetic regenerators containing 186 g of Gd spheres. Four E-type thermocouples are installed inside the Active magnetic regenerator(AMR) to observe the instantaneous temperature variation of AMR. Both warm and cold heat exchangers are designed for large temperature span. The cold heat exchanger, which separates the two AMRs, employs a copper tube with length of 80 mm and diameter of 6.35 mm. In order to minimize dead volume between the warm heat exchanger and AMRs, the warm heat exchangers are located close to the AMRs. The deionized water is used as a heat transfer fluid, and maximum 1.4 T magnetic field is supplied by Halbach array of permanent magnets. The AMR plate, which contains the warm and the cold heat exchangers and the AMRs, has reciprocating motion using a linear actuator and each AMR is alternatively magnetized and demagnetized by a Halbach array of permanent magnet. Since the gap of the Halbach array of permanent magnets is 25 mm and two warm heat exchangers have the motion through it, a compact printed circuit heat exchanger (PCHE) is used as a warm heat exchanger. A maximum no-load temperature span of 26.8 K and a maximum cooling power of 33 W are obtained from the fabricated Active Magnetic Regenerative Refrigerator (AMRR).

Pt/Pd 열전대의 실온보상을 위한 Cu-Ni 합금 개발 (Development of Cu-Ni Binary Alloys for Room Temperature Compensation of Pt/Pd Thermocouple)

  • 김용규;강기훈;감기술;이영희
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.405-410
    • /
    • 2004
  • Compensation wires for Pt/Pd thermocouple was manufactured using Cu/Ni alloys. Their thermoelectric voltage has been tested from room temperature to about $150^{\circ}C$. Alloys of $Cu_{95.5}Ni_{4.5}$ and $Cu_{89.5}Ni_{10.5}$ introduced only small emf differences to Pt/Pd thermocouples, indicating a real possibility of industrial use. Above $1000^{\circ}C$, the temperature difference was expected to he small as ${\pm}0.5^{\circ}C$, and the difference would be minimized by adjusting the Ni content with a small amount.