• 제목/요약/키워드: Thermo-Fluid Analysis

검색결과 103건 처리시간 0.036초

인젝터 노즐 형상이 노즐 내부 유동 및 출구 특성에 미치는 영향 (Influences of Injector Nozzle Shape on Nozzle Internal Flow and Outlet Characteristics)

  • 김창현;이강수;박재인;백제현
    • 한국자동차공학회논문집
    • /
    • 제21권6호
    • /
    • pp.108-116
    • /
    • 2013
  • Diesel engine injector is used for spraying the fuel into the cylinder chamber. Complex phenomenon like cavitation occurs from small scale domain, highly pressurized condition and rapid injection. Flow inside the nozzle affects the whole engine performance including combustion and exhaust, therefore understanding the flow inside the injector nozzle is very important. In this paper, cylindrical and convergent-divergent nozzles are suggested for nozzle types and their influences on nozzle internal flow and nozzle outlet characteristics will be analyzed by changing their outlet diameters.

액정을 이용한 3차원 사각채널 내 혼합대류의 정량적 가시화 (Quantitative Visualization of Mixed Convection in 3-D Rectangular Channels Using TLC Tracers)

  • 박일용;김정수;배대석
    • 동력기계공학회지
    • /
    • 제20권6호
    • /
    • pp.51-57
    • /
    • 2016
  • Experiment is carried out to investigate the mixed convective flow in three-dimensional horizontal rectangular channels filled with high viscous fluid. The particle image velocimetry(PIV) with thermo-sensitive liquid crystal tracers is used for visualizing and analysis. Quantitative data of temperature and velocity are obtained by applying the color-image processing to a visualized image, and neural network is applied to the color-to-temperature calibration. In this study, the fluid used is silicon oil(Pr=909), the aspect ratio(channel width to heigh) is 4 and Reynolds number is $2{\times}10^{-2}$. From the present study, we can visualize the quantitative temperature and velocity of mixed convective flow in three-dimensional horizontal rectangular channels simultaneously.

다상 유동모델과 동적 격자계를 활용한 가스-스팀 발사체계의 열유동과 탄의 운동성능 해석 (Thermo-fluid Dynamic and Missile-motion Performance Analysis of Gas-Steam Launch System Utilizing Multiphase Flow Model and Dynamic Grid System)

  • 김현묵;배성훈;박철현;전혁수;김정수
    • 한국추진공학회지
    • /
    • 제21권2호
    • /
    • pp.48-59
    • /
    • 2017
  • 본 연구에서는 수치모사를 통해 탄의 사출관 내부의 열 유체역학적 분석과 탄의 운동성능 해석을 수행하였다. 동적 격자(dynamic grid)를 사용한 해석영역에서 계산이 진행되었고 증발이 완료된 물을 냉각제로 사용하였다. 고온의 공기와 냉각제간의 상호작용 및 유동장을 해석하기 위해, Realizable $k-{\varepsilon}$ 난류 모델과 VOF (Volume Of Fluid) 모델을 선정하고 냉각제 유량변이에 따른 수치 해석을 진행하였다. 해석결과, 사출관의 압력은 냉각제의 유무에 따라 큰 차이를 보였고, 냉각제량에 따라서도 각각의 차이를 보였다. 탄의 속도와 가속도의 변이는 압력에 종속하여 나타났다.

수치 모사를 통한 사출관 내부의 열유동 해석 (Thermo-fluid Dynamic Analysis through a Numerical Simulation of Canister)

  • 김현묵;배성훈;박철현;전혁수;김정수
    • 한국추진공학회지
    • /
    • 제21권1호
    • /
    • pp.72-83
    • /
    • 2017
  • 본 연구에서는 유도탄 사출관 내부의 수치모사를 통해 이상 유동에 대한 열 유체역학적 분석을 수행하였다. 고정된 해석영역에서 계산이 진행되었고 증발이 완료된 물을 냉각제로 사용하였다. 고온의 공기와 냉각제간의 상호작용 및 유동장을 해석하기 위해, Realizable $k-{\varepsilon}$ 난류 모델과 VOF (Volume Of Fluid) 모델을 선정하고 냉각제 유량에 따른 수치 해석을 진행하였다. 해석결과, 사출관 상부 압력은 냉각제 유량에 따라 비선형적으로 증가하였다. 그리고 내부에서의 유동 진행 과정과 온도분포, 냉각제분포가 밀접한 연관이 있음을 확인하였다. 사출관 하부의 초기 온도는 냉각제량의 증가에 비례하여 감소하지만, 특정시간 이후 경향이 역전되면서 오히려 온도의 상승을 유발하였다. 또한, 혼합가스의 순환유동에 의해 초기의 온도변화가 요동하는 경향도 확인되었다.

범용 열/유체 유동해석 프로그램 NUFLEX의 개발 (DEVELOPMENT OF GENERAL PURPOSE THERMO/FLUID FLOW ANALYSIS PROGRAM NUFLEX)

  • 허남건;원찬식;유홍선;손기헌;김사량
    • 한국전산유체공학회지
    • /
    • 제12권2호
    • /
    • pp.8-13
    • /
    • 2007
  • A general purpose program NUFLEX for the analysis 3-D thermo/fluid flow and pre/post processor in complex geometry has been developed, which consists of a flow solver based on FVM and GUI based pre/post processor. The solver employs a general non-orthogonal grid system with structured grid and solves laminar and turbulent flows with standard/RNG $k-{\varepsilon}$ turbulence model. In addition, NUFLEX is incorporated with various physical models, such as interfacial tracking, cavitation, MHD, melting/solidification and spray models. For the purpose of evaluation of the program and testing the applicability, many actual problems are solved and compared with the available data. Comparison of the results with that by STAR-CD or FLUENT program has been also made for the same flow configuration and grid structure to test the validity of NUFLEX.

광섬유 고속생산용 헬륨 주입식 유리섬유 냉각공정에 대한 열유동 해석 (THERMO-FLUID ANALYSIS ON THE HELIUM INJECTION COOLING OF GLASS FIBER FOR HIGH SPEED OPTICAL FIBER MANUFACTURING)

  • 오일석;김동주;곽호상;김경진
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.92-95
    • /
    • 2011
  • In manufacturing optical fibers, the process starts with the glass fiber drawing from the heated and softened silica preform in the furnace, and the freshly drawn glass fiber is still at high temperature when it leaves the glass fiber drawing furnace. It is necessary to cool down the glass fiber to the ambient temperature before it then enters the fiber coating applicator, since the hot glass fiber is known to cause several technical difficulties in achieving high quality fiber coating. As the fiber drawing speed keeps increasing, a current manufacturing of optical fibers requires a dedicated cooling unit with helium gas injection. A series of three-dimensional flow and heat transfer computations are carried out to investigate the effectiveness of fiber cooling in the fiber cooling unit. The glass fiber cooling unit is simplified into the long cylindrical enclosure at which the hot glass fiber passes through at high speed, and the helium is being supplied through several injection slots of rectangular shape along the cooling unit. This study presents and discusses the effects of helium injection rates on the glass fiber cooling rates.

  • PDF

범용 열/유체 유동해석 프로그램 NUFLEX의 개발 (DEVELOPMENT OF GENERAL PURPOSE THERMO/FLUID FLOW ANALYSIS PROGRAM NUFLEX)

  • 허남건;원찬식;유홍선;손기헌;김사랑
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 춘계 학술대회논문집
    • /
    • pp.87-90
    • /
    • 2007
  • A general purpose program NUFLEX for the analysis 3-D thermo/fluid flow and pre/post processor in complex geometry has been developed, which consists of a flow solver based on FVM and GUI based pre/post processor. The solver employs a general non-orthogonal grid system with structured grid and solves laminar and turbulent flows with standard/RNG ${\kappa}-{\varepsilon}\;SST$ turbulence model. In addition, NUFLEX is incorporated with various physical models, such as interfacial tracking, cavitation, MHD, melting/solidification and spray model. For the purpose of verification of the program and testing the applicability, many actual problems are solved and compared with the available data. Comparison of the results with that by STAR-CD or FLUENT program has been also made for the same flow configuration and grid structure to test the validity of NUFLEX.

  • PDF