• 제목/요약/키워드: Thermo

검색결과 2,363건 처리시간 0.029초

The Applications of the Duplex Stainless Steel as Hyperthermia Materials

  • Kim, Young-Kon
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 춘계학술발표대회
    • /
    • pp.7.1-7.1
    • /
    • 2009
  • The use of Duplex stainless steel as a thermo-implant categorizes into two clinical applications: hyperthermia and thermal ablation or destruction. The goal of hyperthermia is to destroy the heat-sensitive abnormal cells and minimize normal cell death maintaining heat between $42^{\circ}C$ and $46^{\circ}C$. Thermal ablation takes place when the local tissue temperature increases greater than $46^{\circ}C$. This elevated temperature denatures protein irreversibly resulting cellular death. The author introduced several thermo-implants such as thermo-rod, thermo-stent, thermo-coil and thermoacupuncture-needle. Those thermo-implants are made of duplex stainless steel which can produce regulated heat by itself within an induction magnetic field. Thermal ablation characteristics of the thermo-rod on tumor hyperthermia depend on configurations of the thermo-rods and the magnitude of the induction magnetic strength. The exothermic properties of the thermo-implants can be characterized using the calorimetric test and the heat affected zone(HAZ) analyses in vitro. Thermal radiation studies using thermo-coils and thermo-stents show the capability of the occlusion of animal blood vessels and inhibiting the proliferation of the abnormal smooth muscle cell growth and inflammatory cell reactions maintaining the heat between $42^{\circ}C$ and $46^{\circ}C$ minimizing a normal cell death in the study on external iliac artery of the New Zealand White (NZW) rabbit. Thermal stimulation study using thermo-acupuncture needles suggests the potential applications of the automated acupunctural therapies.

  • PDF

가공유기 마르텐사이트 변태를 갖는 합금의 감쇠능에 미치는 가공열처리의 영향 (Effect of Thermo-Mechanical Treatment on the Damping Capacity of Alloy with Deformation Induced Martensite Transformation)

  • 한현성;강창룡
    • 한국재료학회지
    • /
    • 제29권3호
    • /
    • pp.160-166
    • /
    • 2019
  • This study investigates the effect of thermo-mechanical treatment on the damping capacity of the Fe-20Mn-12Cr-3Ni-3Si alloy with deformation induced martensite transformation. Dislocation, ${\alpha}^{\prime}$ and ${\varepsilon}-martensite$ are formed, and the grain size is refined by deformation and thermo-mechanical treatment. With an increasing number cycles in the thermo-mechanical treatment, the volume fraction of ${\varepsilon}-martensite$ increases and then decreases, whereas dislocation and ${\alpha}^{\prime}-martensite$ increases, and the grain size is refined. In thermo-mechanical treated specimens with five cycles, more than 10 % of the volume fraction of ${\varepsilon}-martensite$ and less than 3 % of the volume fraction of ${\alpha}^{\prime}-martensite$ are attained. Damping capacity decreases by thermo-mechanical treatment and with an increasing number of cycles of thermo-mechanical treatment, and this result shows an opposite tendency for general metal with deformation induced martensite transformation. The damping capacity of the thermo-mechanical treated damping alloy with deformation induced martensite transformation greatly affect the formation of dislocation, grain refining and ${\alpha}^{\prime}-martensite$ and then ${\varepsilon}-martensite$ formation by thermo-mechanical treatment.

강자성 판의 열-자탄성학적 불안정성 (Thermo-Magneto-Elastic Instability of Ferromagnetic Plates)

  • 이종세;왕성철
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.153-160
    • /
    • 2002
  • Based on a generalized variational principle for magneto-thermo-elasticity, a theoretical model is proposed to describe the coupled magneto-thermo-elastic interaction in soft ferromagnetic plates. Using the linearized theory of magneto-elasticity and perturbation technique, we analyze the magneto-elastic and magneto-thermo- elastic instability of simply supported ferromagnetic plates subjected to thermal and magnetic fields. A nonlinear finite element procedure is developed next to simulate the magneto-thermo-elastic behavior of a finite-size ferromagnetic plates. The effects of thermal and magnetic fields on the magneto-thermo-elastic bending and buckling is investigated in some detail.

  • PDF

Fe-20Mn-12Cr-3Ni-3Si 합금의 인장성질에 미치는 가공열처리의 영향 (Effect of Thermo-mechanical Treatment on the Tensile Properties of Fe-20Mn-12Cr-3Ni-3Si Damping Alloy)

  • 한현성;강창룡
    • 열처리공학회지
    • /
    • 제32권2호
    • /
    • pp.61-67
    • /
    • 2019
  • This study was carried out to investigate the effect of thermo-mechanical treatment on the tensile properties of Fe-20Mn-12Cr-3Ni-3Si alloy with deformation induced martensite transformation. ${\alpha}^{\prime}$ and ${\varepsilon}$-martensite, dislocation, stacking fault were formed, and grain size was refined by thermo-mechanical treatment. With the increasing cycle number of thermo-mechanical treatment, volume fraction of ${\varepsilon}$ and ${\alpha}^{\prime}$-martensite, dislocation, stacking fault were increased, and grain size decreased. In 5-cycle number thermo-mechanical treated specimens, more than 10% of the volume fraction of ${\varepsilon}$-martensite and less than 3% of the volume fraction of ${\alpha}^{\prime}$-martensite were attained. Tensile strength was increased and elongation was decreased with the increasing cycle number of thermo-mechanical treatment. Tensile properties of thermo-mechanical treated alloy with deformation induced martensite transformation was affected to formation of martensite by thermo-mechanical treatment, but was large affected to increasing of dislocation and grain refining.

열하중을 받는 복합재료 적층판의 손상에 대한 열-음향방출해석 (Analysis of Thermo-Acoustic Emission from Damage in Composite Laminates under Thermal Cyclic Loading)

  • 김영복;민대홍;이덕보;최낙삼
    • 비파괴검사학회지
    • /
    • 제21권3호
    • /
    • pp.261-268
    • /
    • 2001
  • 열-음향방출(thermo-AE) 기법을 이용하여 두께 3mm, $[+45_6/-45_6]_s$ 복합재료 적층판의 열응력 유기 손상에 대한 비파괴평가의 유효성을 연구하였다. 반복적인 열부하 사이클에 의해서 thermo-AE 사상수가 감소하는 경향이 뚜렷하게 나타나서 열부하에 따른 카이저효과가 관찰되었다. 열부하사이클중의 thermo-AE거동을 분석하여 복합재료의 응력자유온도를 결정할 수 있었다. 초음파 C스캔, 광학현미경, 주사형 전자현미경을 통해 섬유파단과 모재파손이 관찰되었으며, 이들 파손 인자는 thermo-AE 신호의 단시간 퓨리에 변환처리에 의해 생성된 3종류의 서로 다른 시간-주파수 특성과 대응하였나 이 특성을 이용하여 복합재료의 냉각열처리 및 반복 열부하사이클시의 손상발생과정 및 내부 마찰거동 내역을 추적할 수 있었다.

  • PDF

Characteristics of Thermo-Acoustic Emission from Composite Laminates during Thermal Load Cycles

  • Kim, Young-Bok;Park, Nak-Sam
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.391-399
    • /
    • 2003
  • The thermo-acoustic emission (AE) technique has been applied for nondestructive characterization of composite laminates subjected to cryogenic cooling. Thermo-AE events during heating and cooling cycles showed a Kaiser effect. An analysis of the thermo-AE behavior obtained during the 1st heating period suggested a method for determining the stress-free temperature of the composite laminates. Three different thermo-AE types classified by a short-time Fourier transform of AE signals enabled to offer a nondestructive estimation of the cryogenic damages of the composites, in that the different thermo-AE types corresponded to secondary microfracturing in the matrix contacting between crack surfaces and some abrasive contact between broken fiber ends during thermal load cycles.

열 사이펀 성능에 따른 동상민감성 지반의 거동 비교 (Frost Heave of Frost Susceptible Soil According to Performance of Thermo-syphon)

  • 박동수;신문범;서영교
    • 한국지반공학회논문집
    • /
    • 제37권10호
    • /
    • pp.27-40
    • /
    • 2021
  • 동상민감성 지반의 융기 및 침하 방지를 위한 공법을 지반 안정화 공법이라고 하며 열 사이펀은 대표적인 지반 안정화 공법 중 하나이다. 열 사이펀은 최근 간편한 해석모델 개발과 더불어 열 해석이 진행되었지만, 이에 따른 동상민감성 지반의 열적 거동을 고려하지 않았다. 따라서 본 연구는 열 사이펀의 성능에 따른 지반의 온도 변화를 위한 열 해석과 이에 따른 지반의 거동을 예측하기 위한 구조해석을 동시에 수행하기 위해 ABAQUS 내부 사용자 서브루틴을 사용하여 열 사이펀을 적용한 TM(Thermo-Mechanical) 모델을 개발하여 열 사이펀의 성능에 따른 지반 융기 억제성능을 확인하였다. 해석결과 열 사이펀의 성능 증가에 따라 지반의 최종 융기가 감소하였으며 냉매 충전율 25%, 50% 그리고 100%의 열 사이펀 적용 시 각각 5.5%, 14.4%, 21% 융기 억제성능을 나타내었다.

Coupled temperature-displacement modeling to study the thermo-elastic instability in disc brakes

  • Ramkumar, E.;Mayuram, M.M.
    • Coupled systems mechanics
    • /
    • 제1권2호
    • /
    • pp.165-182
    • /
    • 2012
  • Macroscopic hot spots formed due to the large thermal gradients at the surface of the disc brake rotor, make the rotor to fail or wear out early. Thermo-elastic deformation results in contact concentration, leading to the non uniform distribution of temperature making the disc susceptible to hot spot formation. The formation of one hot spot event will predispose the system to future hot spotting at the same location. This leads to the complete thermo-elastic instability in the disc brakes; multitude parameters are responsible for the thermo elastic instability. The predominant factor is the sliding velocity and above a certain sliding velocity the instability of the brake system occurs and hot spots is formed in the surface of the disc brake. Commercial finite element package ABAQUS(R) is used to find the temperature distribution and the result is validated using Rowson's analytical model. A coupled analysis methodology is evolved for the automotive disc brake from the transient thermo-elastic contact analysis. Temperature variation is studied under different sliding speeds within the operation range.

Thermo-tracer를 이용한 온실의 열환경 분석 (Thermal environment analysis of greenhouse using Thermo-tracer)

  • 이석건;이종원;이현우;김란숙
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.230-236
    • /
    • 1998
  • Thermal environment of greenhouse was investigated by thermo-tracer in this study. The Thermo-tracer is a high-sensitivity infrared thermometer of non-contact type. The infrared energy emitted from the measured object is converted into an electrical signal by the detector(HgCdTe) and display as a color or black & white thermal image by way of optical scanning, The experiment was conducted for Venlo-type greenhouse with pad & fan system. The temperature difference between measured by Thermo-trace and measured by HOBO sensor is maximum 0.8$^{\circ}C$. Thermo-trace is possible to use for the thermal environment analysis and diagnosis of a cooling and heating system of greenhouse.

  • PDF