• Title/Summary/Keyword: Thermal response

Search Result 1,162, Processing Time 0.026 seconds

Reliability Design Analysis for Underwater Buriend PBA Based on PoF (고장물리 기반 수중 매설형 PBA에 대한 신뢰성 설계 연구)

  • Kim, Ji-Young;Lee, Ki-Won;Yoon, Hong-Woo;Lee, Seung-Jin;Heo, Jun-Ki;Kwon, Hyeong-Ahn
    • Journal of Applied Reliability
    • /
    • v.17 no.4
    • /
    • pp.280-288
    • /
    • 2017
  • Purpose: PBA buried in underwater requires high reliability because of its mission critical characteristic and harsh operational environment during its life cycle. Therefore, various reliability improvement activities are necessary. The defect on PBA manufacturing process have been studied, as a result, many activities and standards have been presented. However, there are less studies regarding failure pattern on physical features based on design. In this paper, we studied a possible failure patten based on physical features that is related with manufacturing process of PBA. And reliability improvement design based on PoF (Physical of Failure) were intruduced in this paper. Methods: A reliability prediction simulation were performed on the components A and B of the H system using Sherlock Software which is a PoF commercial tool from DFR solution. Solder fatigue and PTH fatigue analysis based on thermal cycling profiles and random vibration was analyzed on three earthquake response spectrum. Result: It was validated that life time and reliability improvement design through solder fatigue and PTH fatigue analysis in case of component. For compoenet B, random vibration fatigue was additionally analyzed and validated reliability for earthquakes profile. Conclusion: In design stage prior to manufacturing, PoF can be analyzed, and it is possible to make a reliability improvement/validated design using design data. This study can be applied in every design step and contribute to make more stable development product.

A TiO2-Coated Reflective Layer Enhances the Sensitivity of a CsI:Tl Scintillator for X-ray Imaging Sensors

  • Kim, Youngju;Kim, Byoungwook;Kwon, Youngman;Kim, Jongyul;Kim, MyungSoo;Cho, Gyuseong;Jun, Hong Young;Thap, Tharoeun;Lee, Jinseok;Yoon, Kwon-Ha
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.256-260
    • /
    • 2014
  • Columnar-structured cesium iodide (CsI) scintillators doped with thallium (Tl) are frequently used as x-ray converters in medical and industrial imaging. In this study we investigated the imaging characteristics of CsI:Tl films with various reflective layers-aluminum (Al), chromium (Cr), and titanium dioxide ($TiO_2$) powder-coated on glass substrates. We used two effusion-cell sources in a thermal evaporator system to fabricate CsI:Tl films on substrates. The scintillators were observed via scanning electron microscopy (SEM), and scintillation characteristics were evaluated on the basis of the emission spectrum, light output, light response to x-ray dose, modulation transfer function (MTF), and x-ray images. Compared to control films without a reflective layer, CsI:Tl films with reflective layers showed better sensitivity and light collection efficiency, and the film with a $TiO_2$ reflective layer showed the best properties.

Study on the wetsuit manufacturing status in Korea and future research task (국내 습식 잠수복 생산 업체의 생산실태 조사 및 향후 연구과제)

  • Shin, Hyun-Suk;Choi, Inyoung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.23 no.3
    • /
    • pp.99-108
    • /
    • 2021
  • The present study examines the overall manufacturing status of local wetsuit makers, problems in the manufacturing process, and future research tasks. The study revealed that most manufacturers use neoprene fabric of varying thickness, depending on the body part. Normally, 3 mm-thick fabric is utilized for high-activity body parts and 5 mm-thick fabric is used for high-activity areas requiring thermal insulation. In terms of the manufacturing method, the tools and manufacturing processes used by companies were found to be similar. However, because of the nature of wetsuits requiring a more complicated manufacturing method than that of general clothing, there were some differences in the manufacturing method processes from company to company, such as bonding and ease treatments. According to wetsuit manufacturers, they make incisions in consideration of the body's curvature and the overall shape and design of the wetsuit when developing patterns. For example, most answered that they preform the wrist and ankle parts, where the body's curvature is obvious. On the question regarding the "difficult manufacturing process", the most frequent response was the "bonding" process. Most manufacturers were found to focus on designs that can improve mobility and clothing fit, and commonly experienced low-order quantity as an operational difficulty. As for the question on the wetsuit-related technology needed in the future, the "development of various designs" was the most frequent answer, followed by the "development of lightweight and diverse materials".

Implementation of ISO45001 Considering Strengthened Demands for OHSMS in South Korea: Based on Comparing Surveys Conducted in 2004 and 2018

  • Lee, Junghyun;Jung, Jinyeub;Yoon, Seok J.;Byeon, Sang-Hoon
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.418-424
    • /
    • 2020
  • Background: According to the previous studies, the work-related accident rate decreased in Korea after the introduction of occupational health and safety management system (OHSMS), but there were several disasters in Korea such as subway worker's death at Guui station in 2016 and the Taean thermal power plant accident in 2018, which escalated the social demand for safety. In 2018, OHSMS became an international standard, as ISO45001 was announced. Methods: A survey was conducted to research the implementation status of OHSMS and changes in people's perception, and the results were compared with those of a past survey. Results: Enhanced social demand and various stakeholders' (not only buyer) needs, and social responsibility are perceived as the motivation for the introduction of OHSMS rather than legal compliance or customer demand. In the questionnaire about problems with the implementation of OHSMS, the factors with higher response rate in 2018 than 2004 were "excessive cost" and "complicated documentation management." In the questionnaire about how to promote OHSMS in organizations, most people answered "reduction of workers' compensation insurance rate" in 2004, but most people answered "exemption from health and safety supervision" in 2018. Conclusion: For the effective implementation of ISO45001, emphasis is placed on social demand, training to recognize health and safety as a part of management, and the reduction of certification and consulting costs to promote the introduction of OHSMS. Incentives such as insurance premium cuts and exemptions from health and safety supervision are needed.

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

The Safety and Analgesic Effect of Datura Flos Pharmacopuncture in Sprague-Dawley Rats

  • Jun, Seungah;Lee, Yun Kyu;Lee, Bong Hyo;Kim, Jae Soo;Lee, Hyun-Jong
    • Journal of Acupuncture Research
    • /
    • v.36 no.3
    • /
    • pp.147-153
    • /
    • 2019
  • Background: The aim of this study was to investigate the safety and analgesic effects of Datura Flos pharmacopuncture (DFP). Methods: The analgesic effects of DFP were assessed using mechanical (hot plate), chemical (formalin test), and thermal (von Frey filament test) pain tests. Forty male Sprague Dawley rats were assigned randomly into DFP (75 mg/kg, 150 mg/kg), lidocaine 0.5%, or normal saline group for treatment on Kl3. Gross pathology, histopathology, biochemistry and hematology were performed. Results: In the hot plate test, DFP at a high dose (HDDFP; 150 mg/kg) produced a significant analgesic effect, at 10 and 20-minutes post injection (p < 0.01). Low dose DFP (LDDFP; 75 mg/kg) also showed an analgesic effect at 10 minutes post injection (p < 0.01). In the formalin test, HDDFP produced an analgesic effect, for 0-10 and 10-20 minutes (p < 0.01) post treatment, whereas LDDFP showed analgesic effects between 10-20 minutes (p < 0.05). In the von Frey filament test, DF-H produced an analgesic effect, 10 (p < 0.01) and 20 minutes post treatment (p < 0.05). LDDFP showed analgesic effect at 10 minutes (p < 0.05). In the acupuncture response test, HDDFP produced an analgesic effect at 10 minutes post treatment (p < 0.05). DF-H did not cause any anatomical changes to the liver or kidney and there were no abnormalities in biochemistry or hematology. Conclusion: DF-H was not toxic and provided short term analgesia, suggesting it may be useful in the management of pain.

Geometrically nonlinear thermo-mechanical analysis of graphene-reinforced moving polymer nanoplates

  • Esmaeilzadeh, Mostafa;Golmakani, Mohammad Esmaeil;Kadkhodayan, Mehran;Amoozgar, Mohammadreza;Bodaghi, Mahdi
    • Advances in nano research
    • /
    • v.10 no.2
    • /
    • pp.151-163
    • /
    • 2021
  • The main target of this study is to investigate nonlinear transient responses of moving polymer nano-size plates fortified by means of Graphene Platelets (GPLs) and resting on a Winkler-Pasternak foundation under a transverse pressure force and a temperature variation. Two graphene spreading forms dispersed through the plate thickness are studied, and the Halpin-Tsai micro-mechanics model is used to obtain the effective Young's modulus. Furthermore, the rule of mixture is employed to calculate the effective mass density and Poisson's ratio. In accordance with the first order shear deformation and von Karman theory for nonlinear systems, the kinematic equations are derived, and then nonlocal strain gradient scheme is used to reflect the effects of nonlocal and strain gradient parameters on small-size objects. Afterwards, a combined approach, kinetic dynamic relaxation method accompanied by Newmark technique, is hired for solving the time-varying equation sets, and Fortran program is developed to generate the numerical results. The accuracy of the current model is verified by comparative studies with available results in the literature. Finally, a parametric study is carried out to explore the effects of GPL's weight fractions and dispersion patterns, edge conditions, softening and hardening factors, the temperature change, the velocity of moving nanoplate and elastic foundation stiffness on the dynamic response of the structure. The result illustrates that the effects of nonlocality and strain gradient parameters are more remarkable in the higher magnitudes of the nanoplate speed.

Problems and Countermeasures in the Construction Industry Application of the Serious Accident Punishment Act (중대재해처벌법의 건설업 적용 문제점 및 대응방안)

  • Jung, Joong-Sup;Seo, Jun-Hyeok;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.45 no.2
    • /
    • pp.37-47
    • /
    • 2022
  • The Act on the Punishment of Serious Accidents to Prevent Large-scale Disasters, including Ferry Sewol and Taean Thermal Power Plant, passed the National Assembly on January 8, 2021, and has been in effect since January 27, 2022. However, the law, in which the representative of the headquarters is unlimitedly responsible for each worker's accident, is somewhat unreasonable at a time when a company owns dozens to hundreds of construction sites due to the nature of the construction industry. I agree with the purpose of enacting the law to reduce chronic serious accidents at construction sites, but it is necessary to carefully reconsider the implementation of the law in that punishment alone cannot achieve industrial safety. Previous studies focused on revising the Occupational Safety and Health Act, but there are few studies on the impact on the construction industry after the implementation of the Serious Accident Act. Therefore, this study attempts to derive problems related to the application of the Serious Accident Act and present improvement measures. To this end, after analyzing previous studies, SWOT analysis was performed by applying the Delphi method to derive strengths, weaknesses, opportunities, and threats. In addition, the results of two surveys of safety experts such as public institutions, academia, and companies were reflected, and its countermeasures were presented as follows. S/O strategy: establishing on-site execution capabilities of health and safety management system; W/O strategy: expanding legal and system execution checks; S/T strategy: establishing a risk response system; W/T strategy: expanding consulting by external specialized institutions

Characteristic Analysis of Resistance Spot Welding between Dissimilar Materials of 1.035mm Laminated Vibration Damping Steel with 35㎛ Viscoelastic Resin (35㎛ 점탄성수지가 적용된 1.035mm 제진강판의 이종소재간 저항점용접 특성분석)

  • Bae, Ki-Man;Baek, Jong-Jin;Shin, Chang-Yeul;Kim, Seung-Kyung;Kang, Myungchang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.12
    • /
    • pp.24-29
    • /
    • 2021
  • Recently, owing to the high demand for eco-friendly cars in the automotive industry, noise and vibrations have become major challenges. The use of laminated damping steel is increasing in response to these demands. Laminated damping steel is primarily used in sound insulation plates. The vibration energy is converted into thermal energy due to the viscoelastic resin being located between two steel sheets and being able to damp the vibrations when an external force, such as, noise or vibration is applied to the steel plate. Laminated damping steel is chiefly applied to dash panels in automotive body parts, and because of its structure, junction technology for bonding with other components is necessary. However, there has not been sufficient research conducted on junctions. In this study, regardless of the electrode shape, in the range of 4.0 ~ 8.0 kA welding current, the same welding force and welding time were applied which were 2.8 kN and 200 m/s (12 cycles) and the tensile shear load and nugget size were analyzed after the resistance spot welding between different materials of laminated damping steel with a thickness of 1.035 mm. The results show that in the range of 5 ~ 8 kA welding current, 1.035 mm laminated damping steel meets the MS181-15 standard, which is the technical standard of Hyundai-Kia Motors.

Recent Progress in Energy Harvesters Based on Flexible Thermoelectric Materials (유연한 열전소재를 이용한 에너지 하베스터 연구개발 동향)

  • Park, Jong Min;Kim, Seoha;Na, Yujin;Park, Kwi-Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.119-128
    • /
    • 2022
  • Recent advancement of Internet of Things (IoT) and energy harvesting technology enable realization of flexible thermoelectric energy harvester (f-TEH), with technological prowess for use in biomedical monitoring system integrated applications. To expand a flexible thermoelectric energy harvesting platform, the f-TEH must be required for optimized flexible thermoelectric materials and device structure. In response to these demands related to thermoelectric energy harvesting, many research groups have investigated various f-TEHs applied as a power source for wearable electronics. As a key member of the f-TEH, film-based f-TEHs possess significant applicability in research to realize self-powered wearable electronics, owing to their excellent flexibility, low thermal conductivity, and convenient fabrication process. Thus, based on the rapid growth of thermoelectric film technology, this review aims to overview comprehensively the f-TEH made of various inorganic/organic thermoelectric materials including developed fabrication methods, high thermoelectric performance, and wide-range applications.