• Title/Summary/Keyword: Thermal recovery

Search Result 534, Processing Time 0.027 seconds

Performance Design Analysis of the Bottoming System of Combined Cycle Power Plants (복합화력발전 하부시스템의 성능설계해석)

  • Lee, B.R.;Kim, T.S.;Ro, S.T.;Shin, H.T.;Jeon, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.738-743
    • /
    • 2001
  • A computer program, capable of performing thermal design analysis of the triple pressure bottoming system of combined cycle power plants, was developed. The program is based on thermal analysis of the heat recovery steam generator and estimation of its size and steam turbine power. The program is applicable to various parametric analyses including optimized design calculation. This paper presents examples of analysis results for the effects of arrangement of heat exchanger units, steam pressures and deaerating sources on design performance indices such as steam turbine power and the size of heat recovery steam generator.

  • PDF

Performance Test of Low Temperature Waste Heat Recovery Heat Exchanger Using Self-excited Oscillating Heat Pipe (자려 진동형 히트 파이프를 이용한 저온 폐열 회수 열교환기의 성능 실험)

  • 이욱현;이종현;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.853-859
    • /
    • 2000
  • In this study, low temperature waste heat recovery heat exchanger was developed using a principle of self-excited oscillating heat pipe. The heat exchanger of serpentine type was composed of extruded flat aluminum tube with 6 channels (3 nm$\times$ 2.75nm) and louvered fin. The heat transfer area density of heat exchanger was $331.9 m^2/m^3$. Working fluid is R141b and charge ratio was 40% by volume. Heat transfer rate and the effectiveness of heat exchanger was primary concern of this study. As a result, the effectiveness of heat exchanger was about 0.4-0.67, and recovered waste heat rate was about 4.5 kW per one unit of heat exchanger.

  • PDF

Stability of the Cable-in-Conduit Conductors (CIC 초전도 도체의 안정성)

  • 류경우
    • Electrical & Electronic Materials
    • /
    • v.10 no.9
    • /
    • pp.895-900
    • /
    • 1997
  • A Quench in cable-in-conduit (CIC) conductors is often initiated by a disturbance such as strand motion that generates a highly localized normal zone in a strand or a few strands of the CIC conductors. The localized normal zone causes current and heat transfer between a disturbed strand and neighboring strands. Electrical and thermal contact characteristics between strands thus have an effect on the transient stability of the CIC conductors. In this paper the effect of contact characteristics between strands on the CIC conductor stability is presented based on the measured heat transfer characteristics of supercritical helium (SHe) for the local heating. The quench and recovery processes of the strands for the abrupt and highly localized disturbance are analyzed at the boundary between quench and recovery.

  • PDF

Experimental Study on the Optimal Heat Exchanger of Thermoelectric Generation System for Industrial and Automobile Waste Heat Recovery (차량 및 산업설비 폐열회수용 열전발전시스템의 최적 열교환 시스템에 관한 실험적 연구)

  • Chung, Jae-Hoon;Kim, Woo-Chul;Lee, Jin-Ho;Yu, Tae-U.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.460-463
    • /
    • 2008
  • A large part of the overall industrial energy is dissipated as waste heat despite of much development in the utilization of thermal energy. A mean efficiency is reported to be only around 30 to 35%. The existing waste heat recovery technology has reached its limit and consequently, the development of a new technology is necessary. Improving efficiency using thermoelectric technology has recently come into the spotlight because of its unique way to recover thermal energy. In fact, thermoelectric generator directly converts thermal energy into electric energy by a solid state without any moving parts. Futhermore remarkable improvement in the thermoelectric energy conversion efficiency has been achieved. In this study, a thermoelectric generator was made using commercialized thermoelectric modules. With thermoelectric modules attached on a duct surface, hot air was blown into the duct using a hot air blower. On the other side of the module, a water jacket was attached to cool the module. With different air inlet temperatures and water flowrates, the electrical power of the thermoelectric generator was measured.

  • PDF

A Study on Hydrogen Production with High Temperature Solar Heat Thermochemical Cycle by Heat Recovery (열회수에 따른 고온 태양열 열화학 싸이클의 수소 생산에 관한 연구)

  • Cho, Ji-Hyun;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.13-22
    • /
    • 2017
  • Two-step water splitting thermochemical cycle with $CeO_2/ZrO_2$ foam device was investigated by using a solar simulator composed of 2.5 kW Xe-Arc lamp and mirror reflector. The hydrogen production of $CeO_2/ZrO_2$ foam device depending on heat recovery of Thermal-Reduction step and Water-Decomposition step was analyzed, and the hydrogen production of $CeO_2/ZrO_2$ and $NiFe_2O_4/ZrO_2$ foam devices was compared. Resultantly, the quantity of hydrogen generation increased by 52.02% when the carrier gas of Thermal-Reduction step is preheated to $200^{\circ}C$ and, when the $N_2/steam$ is preheated to $200^{\circ}C$ in the Water-Decomposition step, the quantity of hydrogen generation increased by 35.85%. Therefore, it is important to retrieve the heat from the highly heated gases discharged from each of the reaction spaces in order to increase the reaction temperature of each of the stages and thereby increasing the quantity of hydrogen generated through this.

Study on Recovery of Polymeric Raw Materials from WastePolystyrene in Motor Oil using Microwave Thermal Decomposition (마이크로웨이브 열분해(熱分解)를 이용(利用)한 폐(廢) 폴리스티렌과 모터 오일 혼합물(混合物)로부터 고분자(高分子) 원료(原料) 물질(物質) 회수(回收)에 관한 연구(硏究))

  • Kang, Tae-Won
    • Resources Recycling
    • /
    • v.15 no.5 s.73
    • /
    • pp.11-16
    • /
    • 2006
  • A novel microwave-induced pyrolysis was used for the recovery of valuable products from waste polystyrene in motor oil. Quartz tube was introduced as microwave reactor and silicon carbide was used as the microwave absorbent. In the experiments, different pyrolysis conditions were applied, such as time range from 30 minutes to 1 hour and microwave input power range from 180 to 250W. The distillate products from pyrolysis were analyzed with GC/MS. Styrene, 1-methyl styrene, toluene, ethyl benzene were the four main products. Styrene recovery rate from polystyrene was around 50%. Temperature for the complete pyrolysis using microwave was around $300^{\circ}C$ which is much lower than that of conventional thermal pyrolysis.

A Study on the Measurement for the Recovery Stress of Intelligent Composite by Experiment (실험법에 의한 지능성 복합체의 회복응력 측정에 관한 연구)

  • Hawong, Jai-Sug;Lee, Hyo-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.515-523
    • /
    • 2003
  • Shape memory is physical phenomenon which a platically metal is restored to its original shape by a solid state phase change by heating. TiNi alloy the most effective material in the shape memory alloy(SMA). To study(measure) recovery stress of intelligent composite. Ti50-Ni50 shape memory matrix with prestrain SMA fiber. When SMA fiber of the intelligent composite is heated over austenite starting temperature(As) by electric heating. a recovery stress are generated. The recovery stress of the intelligent composite was measured by strain gage or photoelastic experiment. Measuring method of recovery stress by photoelastic experiment was developed in this research. It was certified that photoelastic experiment was more effective and more precise than strain gage method in the measurement of recovery stress.

Fabrication and Sensing Characteristics of Multi-Walled Carbon Nanotube Gas Sensor for No2 Detection (이산화질소 감지용 다중벽 탄소나노튜브 가스센서의 제작 및 감응 특성)

  • 조우성;문승일;김영조;이윤희;주병권
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.3
    • /
    • pp.294-298
    • /
    • 2004
  • Carbon nanotubes(CNTs) were synthesized by thermal chemical vapor deposition(CVD) method. To fabricate CNT gas sensor, catalyst metal layer was deposited on microstructure. The CNT gas detecting layer was grown by thermal CVD method on the catalyst metal layer. In order to investigate the gas sensing characteristics of the fabricated CNT gas sensor, it was exposed in NO$_2$ gas and sensitivity, response, and recovery time were measured. As the result, this sensor has better reproductibility and faster recovery time than another CNT gas sensors.

Approximate Optimum Thermal Design Analysis of Combined Cycle Power Plant (복합화력 발전플랜트의 근사 최적 열설계 해석)

  • Jeon, Y.J.;Shin, H.T.;Lee, B.R.;Kim, T.S.;Ro, S.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.782-787
    • /
    • 2001
  • An optimum thermal design analysis of the combined cycle power plant with triple pressure heat recovery steam generator was performed by the numerical simulation. The optimum design module used in the paper is DNCONF, a function of IMSL Library, which is widly known as a method to search for the local optimum. The objective function to be minimized is the cost of total power plant including the steam turbine power enhancement premium. The result of this paper shows that the cost reduces if the design point of power plant becomes the local optimum, and many calculations at various initial conditions should be carried out to get the value near the global optimum.

  • PDF

A Study on the Safety Improvement of the High Temperature Ceramic Heat Recovery System (고온 세라믹 폐열회수장치의 안전성 향상 연구)

  • Park, Yong-Hwan;Kang, Young-Goo;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.107-114
    • /
    • 1996
  • A study to Improve the safety of the ceramic heat exchanger In the high temperature heat recovery system was performed in terms of air flow passes. The numerical and finite element analyses on the heat transfer and thermal stresses in the ceramic core related with air passes were carried out. The results showed that the stresses in the ceramic core induced by the thermal expansion are large enough to cause failure of the brittle ceramic core. The imployment of triple-pass air flow for the same ceramic core could increase the efficiency and effectively release approximately 20% of the maximum thermal stressess, thus improving the safety of the ceramic heat exchanger. The use of triple-pass, however, is limited by the amount of air flow due to the increase of pressure drop.

  • PDF