• Title/Summary/Keyword: Thermal profile

Search Result 472, Processing Time 0.029 seconds

Computer Simulation for the Thermal Analysis of the Energy Storage Board (에너지 축열보드 열해석을 위한 컴퓨터 수치해석)

  • 강용혁;엄태인;곽희열
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.224-232
    • /
    • 1999
  • Latent heat storage system using micro-encapsuled phase change material is effective method for floor heating of house and building. The temperature profile in capsule block and flow rate of hot water are important parameters for the development of heat storage system. In the present study, a mathematical model based on 3-D, non-steady state, Navier-Stokes equations, scalar conservation equations and turbulence model ($\kappa$-$\varepsilon$), is used to predict the temperature profiles in capsule and the velocity vectors in hot water pipe. The multi-block grids and fine grids embedding are used to join the circle in hot water pipe and square in capsule block. The phase change process of the capsule is quite complex not only because the size of phase change material is very small, but also because phase change material is mixed with the cement to form thermal storage block. In calculation, it's assumed that the phenomena of phase change is limited only the thermal properties of phase change material and the change of boundary is not happened in capsule. The purpose of this study is to calculate the temperature profiles in capsule block and velocity vectors in hot water pipe using the numerical calculation. Two kinds of thermal boundary condition were considered, the first (case 1) is the adiabatic condition for the both outside surfaces of the wall, the second (case 2) is the case in which one surface is natural convection with atmosphere and another surface is adaibatic. Calculation results are shown that the temperature profile in capsule block for case 1 is higher than that for case 2 due to less heat loss in adaibatic surface. Specially, in the domain of near Y=0, the difference of temperature is greater in case 1 than in case 2. The detailed experimental data of capsule block on the temperature profile and the thermal properties such as specific heat and coefficient of heat transfer with the various temperature are required to predict more exact phenomena of heat transfer.

  • PDF

NUMERICAL ANALYSIS FOR UNSTEADY THERMAL STRATIFIED FLOW WITH HEAT TRACING IN A HORIZONTAL CIRCULAR CYLINDER

  • Jeong, Ill-Seok;Song, Woo-Young;Park, Man-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.304-309
    • /
    • 1997
  • A method to mitigate the thermal stratification flow of a horizontal pipe line is proposed by heating external bottom of the pipe with electrical heat tracing. Unsteady two dimensional model has been used to numerically investigate an effect of the external Denting to the thermally stratified flow. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature distribution, streamline profile and Nusselt numbers of fluids and pipe walls with time are analyzed in case of externally heating condition. no numerical result of this study shows that the maximum dimensionless temperature difference between the hot and the cold sections of pipe inner wall is 0.424 at dimensionless time 1,500 ann the thermal stratification phenomena is disappeared at about dimensionless time 9,000. This result means that external heat tracing can mitigate the thermal stratification phenomena by lessening $\Delta$ $T_{ma}$ about 0.1 and shortening the dimensionless time about 132 in comparison with no external heat tracing.rnal heat tracing.

  • PDF

Thermal stratification in a horizontal pipe of pressurizer surge line (가압기밀림관의 수평배관내 열성층유동)

  • Jung, I,S,;Kim, Y.;Youm, H.K.;Park, M.H.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1449-1457
    • /
    • 1996
  • In this paper, the unsteady two dimensional model for the thermal stratification in the pressurizer surge line of PWR plant has been proposed to numerically investigate the heat transfer and flow characteristics. The dimensionless governing equations are solved by using the Control Volume Formulation and SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm. The temperature profile of fluids and pipe wall with time are shown when the thermal stratification occurs in the horizontal pipe. The numerical result shows that the maximum dimensionless temperature difference is about O.514 between hot and cold section of pipe wall at dimensionless time 1,632.

The study on dielectric properties of $Ta_2O_5$ thin films obtained by thermal oxidation (Thermal Oxidation 법으로 제조된 $Ta_2O_5$ 박막의 유전체 물성에 관한 연구)

  • Kim, I.S.;Kim, H.J.;Min, B.K.;Song, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1473-1475
    • /
    • 2002
  • This study presents the dielectric properties of $Ta_2O_5$ MIM capacitor structure processed by thermal oxidation. The AES(auger electron emission) depth profile showed thermal oxidation effect gives rise to the $O_2$ deficiened into the new layer. The leakage current density respectively, at $1{\sim}3{\times}10^{-3}$(kV/cm) were $3{\times}10^{-4}-10^{-8}(A/cm^2)$. Leakage current density behavior is stable irrespective of applied electric field, the frequency va capacitance characteristic enhanced stability. The capacitance vs voltage measurement that, $V_{fb}$(flat-band voltage) was increase dependance on the thin films thickness, it is changed negative to positive.

  • PDF

A Field Test on the Steady State Thermal Performance for the Forced Convection of Large Size Electric Air Heater (대형 전기온풍기 정상상태 열적성능의 현장시험에 관한 연구)

  • 최창용;김홍건
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.99-103
    • /
    • 2002
  • A field test was peformed to estimate the thermal performance of the forced convection electric air heater by the experiment. Air temperature, flow rate and electrical power input were measured with the related measurement sensors, and acquisition methods for the measured data were studied to effectively estimate the thermal performance of the tested air heater. To determine the mean air temperature at the flow cross-section, measuring positions were chosen by considering the flow velocity profile and the equally divided cross-sectional area. From the experimental results, thermal efficiency is obtained as an indication of the tested electric air heater performance.

  • PDF

A Study on the Precise Measurement of the Performance in the Heating System (발열시스템 열적 성능의 정밀측정에 관한 연구)

  • 최창용;김홍건
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.6
    • /
    • pp.60-67
    • /
    • 2002
  • A precise measurement of field test was performed to estimate the thermal performance of the forced convection electric air heater by experiment. Air temperature, flow rate and electrical power input were measured with the related measurement sensors, and acquisition methods for the measured data were studied to estimate the thermal performance of the tested air heater effectively. To determine the mean air temperature at the flow cross-section, measuring positions were chosen by considering the flow velocity profile and the equally divided cross-sectional area. From the experimental results, thermal efficiency was obtained accurately as an indication of the tested heating system performance.

The Thermal Analysis of Te-based media for Optica1 Recording (광기록에 이용되는 Te-based Mediao에 대한 열적 해석)

  • 천석표;이성준;이현용;정홍배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.123-126
    • /
    • 1994
  • We discussed the thermal analysis for recording media with the variation of the laser pulse duration and the power and the temperature distribution for the optimized Te-based antireflection structure by using the computer calculations. If the radial diffusion of heat is negligible, we can calculate the maximum temperature at the spot center in recording layer by Simple Method, and the temperature profile considering the specific heat and the latent heat by Numerical Method. As a result, the effect of the heat sinking which acted as a loss for the hole formation can be minimized by introducing the pulse of the hole formation duration( $\tau$ ) shorter than the thermal time constant( $\tau$$\sub$D/) of dielectric layer. This requirments can be satisfied as using the dielectric thickness of the 7nd ART condition or the dielectric materials with low thermal diffusivity.

  • PDF

Determination of Thermal Decomposition Parameters for Ablative Composite Materials (삭마용 내열 복합재료의 열분해 반응인자 결정)

  • Kim Yun-Chul
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.22-25
    • /
    • 2005
  • The thermal degradation of carbon/phenolic composite have been studied at high temperature by using thermogravimetric (TGA). A heating .ate of 5, 10, 15, 30 and $50^{\circ}C/min$ was used for the determination of thermal decomposition parameters of composite materials at high-temperature service. It has been shown that as the heating rates is increased, the peak decomposition rates are occur at higher temperature. Based on results of thermogravimetric analysis, the pyrolysis process is analyzed and physical and mathematical models for the process are proposed. The thermal analysis also has been conducted using transient heat conduction and the in-depth temperature distribution and the density profile were evaluated along the solid rocket nozzle. As a future effort the thermal decomposition parameter determined in this investigation will be used as input to thermal and mechanical analysis when subjected to solid rocket propulsion environment.

  • PDF

Thermal Degradation of Black Cobalt Solar Selective Coatings (흑색 코발트 태양 선택흡수막의 열퇴화)

  • Lee, Kil-Dong
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.9-15
    • /
    • 2015
  • Black cobalt solar selective coatings were prepared by using an electroplating method. The changes in the optical properties of the black cobalt selective coating due to thermal degradation were analyzed by using the Auger electron spectroscopy (AES) and spectrophotometer. The black cobalt selective coating was prepared on a copper substrate by using a synthesized electrolyte with $CoCl_2$ and KSCN at a current density of ${\sim}0.5A/dm^2$ for 45s ~ 60s. Its optical properties were a solar absorptance (${\alpha}$) of the order of 0.80 ~ 0.84 and a thermal emittance (${\epsilon}$) of 0.01. From the AES depth profile analysis of heated sample, thermal degradation of the black cobalt selective coating heated for 33 hours at temperature of $350^{\circ}C$ occurred primarily due to interdiffusion at interface of cobalt and copper substrate. This results were predictable that the ${\alpha}$ decreases due to the thermal oxidation and diffusion.

The effect of the system factors on the shape of the S/L interface in GaAs single crystal grown by VGF method (VGF법을 사용한 GaAs 단결정 성장시 계의 구성요소가 고액계면의 형상에 미치는 영향)

  • Seung-Ho Hahn;Hyung-Tae Chung;Young-Kyu Kim;Jong-Kyu Yoon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.4 no.1
    • /
    • pp.33-41
    • /
    • 1994
  • It is well known that the position and the shape of the S/L interface affect the qualities of the single crystal in the growth process. Thus the information of the temperature profile in the growth system is very important. In this study, we developed the program to predict the temperature profile from the setting values of the heating blocks in VGF(vertical gradient freezing) single crystal growth system. With this program, we studied the effects of the materials and the sizes of support rod, the materials of the crucible on the S/L interface shape. The larger radius and/or smaller thermal diffusivity support rod was, the flatter the S/L interface was. When the thermal conductivity of crucible was isotropic, the S/L interface was more concave downward to the solid phase in proportional to the increase of thermal diffusivity of the crucible. By the comparison of the S/L interface shape between PBN crucible and quartz crucible for the same condition, the effect of anisotropy of thermal conductivity of crucible showed different trends with respect to the position of the S/L interface.

  • PDF