• Title/Summary/Keyword: Thermal power plan

Search Result 61, Processing Time 0.029 seconds

A Study on Expanding the Recycling of Coal Ash for Minimizing Environmental Impact Imposed by the Establishment of Thermal Power Plant Ash Ponds (화력발전소 회처리장 조성에 따른 환경영향 최소화를 위한 석탄회 재활용 확대방안에 관한 연구)

  • Suh, Dong-Hwan;Maeng, Jun-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.5
    • /
    • pp.472-486
    • /
    • 2015
  • More than 8M tons of coal ashes are generated from coal-fired thermal power plants every year in Korea. Excluding the recycled portion (Current recycling rate: approximately 70%), all of the generated coal ashes end up in coastal landfills. Currently, the difficulties faced in establishing new ash treatment fields are attributed to the concerns raised over the environmental impacts caused by the landfills at individual plant facilities. Given the number of coal-fired thermal power plants to be built in the future (reflected in the 7th Basic Plan for Long-term Electricity Supply and Demand), building new ash treatment fields or seeking a new treatment plan seems unavoidable. Based upon a review of coal ash and its management, this study concluded that the most effective and fundamental strategy to minimize the environmental impacts resulting from coal ash landfills is to avoid constructing new coal-fired powerplants and furthermore, suggests that the practice of beneficial use and recycling the produced coal wastes should be encouraged.

Thermal and Electrical Energy Mix Optimization(EMO) Method for Real Large-scaled Residential Town Plan

  • Kang, Cha-Nyeong;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.513-520
    • /
    • 2018
  • Since Paris Climate Change Conference in 2015, many policies to reduce the emission of greenhouse gas have been accelerating, which are mainly related to renewable energy resources and micro-grid. Presently, the technology development and demonstration projects are mostly focused on diversifying the power resources by adding wind turbine, photo-voltaic and battery storage system in the island-type small micro-grid. It is expected that the large-scaled micro-grid projects based on the regional district and town/complex city, e.g. the block type micro-grid project in Daegu national industrial complex will proceed in the near future. In this case, the economic cost or the carbon emission can be optimized by the efficient operation of energy mix and the appropriate construction of electric and heat supplying facilities such as cogeneration, renewable energy resources, BESS, thermal storage and the existing heat and electricity supplying networks. However, when planning a large residential town or city, the concrete plan of the energy infrastructure has not been established until the construction plan stage and provided by the individual energy suppliers of water, heat, electricity and gas. So, it is difficult to build the efficient energy portfolio considering the characteristics of town or city. This paper introduces an energy mix optimization(EMO) method to determine the optimal capacity of thermal and electric resources which can be applied in the design stage of the real large-scaled residential town or city, and examines the feasibility of the proposed method by applying the real heat and electricity demand data of large-scale residential towns with thousands of households and by comparing the result of HOMER simulation developed by National Renewable Energy Laboratory(NREL).

Education Contents Development that Use Thermoelectric Power Plant Generation Facility Third Dimensional Model (3차원 모델을 활용한 발전설비 교육컨텐츠 개발)

  • Kim, Seok-B.;Back, Nam-H.;Son, Kwang-S.;Kim, Joo-Seok;Moon, Seung-Jae;Lee, Jae-Heon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.362-368
    • /
    • 2008
  • The purpose of this is providing employees who take charge of operation and maintenance at power plant with education contents that can be used for self-studying and on the job training through their computers. We developed the education contents for making actually application possible using this piping and instrument diagram(P&ID), operation and maintenance procedure, unit specification and material of 500MW thermal power plant those include unit equipment 3-dimension animation, character and narration performance considering making teaching plan, flexibility, extension, reuse, maintenance and focusing on user. Specially, we developed the flash type education contents about power plant operation based on the plant 3-dimension animation and the spot real picture concerned about new generation trend for power plant incoming employees actual knowledge. in addition, this contents apparently contributed to improve the level of employees technical power as distributed to employees.

  • PDF

Monitoring of Urban Thermal Environment Change in Daejun Using Landsat TIR Satellite Data (Landsat 열적외 영상자료를 활용한 대전시 열 환경 변화 모니터링)

  • Choi, Jin-Ho;Cho, Hyun-Ju;Jong, Hoan-Do
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.5
    • /
    • pp.513-523
    • /
    • 2013
  • This purpose of this work is to explore the characteristics of urban thermal environment distribution with the case of Daejeon. To do that, this work applied GIS Spatial Statistics to the LandSAT images gathered from 2000 to 2011. The urban thermal environment distribution at the time point of 2 showed high spatial autocorrelation. Therefore, it is judged that spatial autocorrelation is needed to increase the reliability and explanatory power of the characteristics of thermal environment distribution. In the case of the thermal in Daejeon, its positive clustering appeared high at the time point of 2, and its clustering in 2011 more gradually decreased than that in 2000 to 2011. In particular, given the decrease in the core H-H region, it was found that the thermal environment of Daejeon was greatly improved. However, since the rise in the region L-L means another changed like construction of a new city, it is judged that it is necessary to come up with a proper plan. It is considered that this analysis of the characteristics of urban thermal environment distribution in consideration of spatial autocorrelation L-L be useful for providing a fundamental material necessary for the policy and project of thermal environment improvement.

The Study of Compensation Strategy for FACTS Application in Power System (전력계통의 FACTS적용을 위한 직병렬 보상방안 연구)

  • Lee, Geun-Joon;Chang, Byung-Hoon;Kim, Yeng-Han
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.112-116
    • /
    • 1996
  • This paper presents the study results of FACTS application plan for transmission capability Enhancement. Power transfer across the KEPCO system resulting from a concentration of load in the Kyung-In area are subject to thermal, voltage and stability constrains. In the analysis study of the KEPCO system in 2000 and 2006 year. voltage stability analysis. modal analysis and dynamic stability were simulated by the power system analysis tools(VSTAB, PSS/E).

  • PDF

Economic Evaluation of Alternatives for CO2 Reduction of Thermal Power Generation Companies using ROPM: Comparing CCS with RPS Implementation (실물옵션을 활용한 화력발전회사의 CO2 감축대안의 경제성 평가: CCS와 RPS 이행의 비교)

  • Lee, Dong Su;Jeong, Kiho
    • Environmental and Resource Economics Review
    • /
    • v.20 no.1
    • /
    • pp.61-98
    • /
    • 2011
  • This study conducts economic evaluation of alternatives for $CO_2$ reduction of thermal power plants. Two alternatives in reducing $CO_2$ emission are considered for the evaluation under the RPS(Renewable Portfolio Standard) system; one is to perform renewable energy quotas and another is to construct green thermal power plants using CCS(Carbon Capture and Sequestration). As evaluation methods, DCF(Discount Cash Flow) and ROPM(Real Options Pricing Method) are employed. At a discount rate of 7.5% applied to the Electricity Supply and Demand Plan, it is shown that green thermal power generation has economic dominance under both evaluation methods.

  • PDF

Utility scale solar power development in Nepal

  • Adhikari, Rashmi
    • Bulletin of the Korea Photovoltaic Society
    • /
    • v.6 no.1
    • /
    • pp.86-91
    • /
    • 2020
  • Nepal is among the richest in terms of water resource availability and it is one of the most important natural resources of the country. Currently, 72% of the population is electrified through the national grid system. The power generation mix into the grid is hydro dominated with minor shares generated from solar and thermal (accounts for less than 1%). To achieve sustainable development in the power sector it is essential to diversify power generation mix into the grid. Knowing the facts, the government has a plan to achieve a 5-10% share of power generation from solar and mix it into the grid system. Solar is the second most abundant, prominent and free source of renewable in the context of Nepal. This study mainly focuses on the grid-connected solar system, its importance, present status, government efforts, and its need. It is based on the review of literature, news published in national newspaper online news and international organization's report.

A Study on the Development of Fouling and Plugging Margin Evaluation Methods for Shell-and-Tube Heat Exchangers (다관원통형 열교환기의 파울링 및 관막음 여유 평가법)

  • Hwang, Kyeong-Mo;Jin, Tae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.55-60
    • /
    • 2003
  • As operating time of heat exchangers progresses, fouling generated by water-borne deposits increases and thermal performance decreases. The fouling is known to interfere with normal flow characteristics and reduce thermal efficiencies of heat exchangers. The heat exchangers of nuclear power plants have been analyzed in terms of the heat flux and heat transfer coefficient at test conditions based on the ASME OM-S/G-Part 2 as a means of heat exchanger management. It is hard to estimate the heat performance trend and to establish the future management plan. This paper describes the fouling evaluation method which can evaluate the thermal performance for heat exchangers and estimate the future fouling variations and the plugging margin evaluation method which can reflect the current fouling level developed in this study. To develop the fouling and plugging margin evaluation methods for heat exchangers, fouling factor was introduced based on the ASME O&M codes and TEMA standards. For the purpose of verifying the two evaluation methods, the fouling and plugging margin evaluations were performed for a component cooling heat exchanger in a nuclear power plant.

  • PDF

The Effects of Penetration of the Electric Vehicles on the Electric Power Grid in the Jeju Island (제주도에서 전기자동차 보급이 전력계통에 미치는 영향)

  • Oh, Seong-Bo;Lee, Gae-Myoung;Hwang, Choong-Gu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • The Jeju Special Self-Government Provincial Government has made the plan penetrating gradually electric vehicles(EVs) in the Jeju Special Self-Government Province(Jejudo). However the effects of EVs penetration on the electrical grid of the Jejudo is not reported. In this paper the yearly electric energy consumed by the EVs was calculated and the effects of the EV penetration on the peak power of the grid were analyzed in the Jejudo for the future 10 years, and we hope that our study results will help the governors realize the EVs penetration plan in the Jejudo. The calculation results show that the rate of the electric energy used by the EVs will become to 2.9% at its maximum at the 2017 year when the penetration rate of EVs in passenger cars becomes 10%, and the rate of the electric energy consumed by the EVs will become to 9.4% at its maximum at the 2020 year when the penetration rate of EVs in passenger cars becomes 30%. The concepts of smart-charging capacity and 100%-valley-filling charging capacity of the grid were defined and calculated for the Jeju Grid, and the grid was analyzed to have the sufficient EV charging capacity until the 2022 year.

A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater (급수가열기 동체 감육 현상 규명을 위한 유동해석 연구)

  • Shin, Min-Ho;Hwang, Kyeong-Mo;Kim, Kyung-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2017-2022
    • /
    • 2004
  • There are multistage preheaters in the power generation plan to improve the thermal efficiency of the plant and to prevent the components from the thermal shock. The energy source of these heaters comes from the extracted two phase fluid of working system. These two-phase fluid can cause the so-called Flow Accelerated Corrosion(FAC) in the extracting piping and the bubble plate of the heater for example, in case of point Beach Nuclear Power Plant and in the Wolsung Nuclear Power Plant. The FAC is due to the mass transport of the thin oxide layer by the convection. FAC is dependent on many parameters such as the operation temperature, void fraction, the fluid velocity and pH of fluid and so on. Therefore, in this paper velocity was calculated by FLUENT code in order to find out the root cause of the wall thinning of the feedwater heaters. It also includeed in the fluid mixing analysis model are around the number 5A feedwater heater shell including the extraction pipeline. To identify the relation between the local velocities and wall thinning, the local velocities according to the analysis results were compared with distribution of the shell wall thicknes by ultrasonic test.

  • PDF