• 제목/요약/키워드: Thermal performance standards

검색결과 109건 처리시간 0.033초

환경 대기 중 ppt 수준의 황화수소 분석을 위한 GC 방식의 검량 기법에 대한 연구 (Calibration Methods for the Gas Chromatographic Analysis of ppt-level Hydrogen Sulfide (H2) in Air)

  • 김기현;오상인;최여진;최규훈;주도원
    • 한국대기환경학회지
    • /
    • 제19권6호
    • /
    • pp.679-687
    • /
    • 2003
  • In this study, we investigated the analytical techniques to quantify the ambient concentration of hydrogen sulfide (H$_2$S) in air at ppt concentration level. For this purpose, an on-line GC analytical system equipped with both pulsed-flame photometric detector (PFPD) and thermal desorption unit (TDU) was investigated by collecting ambient air samples. The results of our study generally indicated that calibration conditions of GC system is highly sensitive to affect the accuracy of the analytical technique. Most importantly. we found that the use of different matrices in the the preparation stage of working standards was sensitive to control the overall performance of this technique. The calibration of our analytical system was tested by the two types of working standard (prepared by mixing either with high purity $N_2$ or with the ambient air). According to this test, the latter represented more efficiently the detecting conditions of actual air samples. The peak occurrence patterns of both air samples and standards (prepared by mixing with ambient air) were altered in a similar manner as the function of the loaded volume; however, it was not the case for the $N_2$-mixed standards. Results of our study suggest that detection of H$_2$S is highly different from other sulfides and that its quantification requires minimiaing interfering effects of non -pure substance (like water vapor) and (either sorptive or destructive) loss effects.

Optimal Design of a Coudé Mirror Assembly for a 1-m Class Ground Telescope

  • Jaehyun Lee;Hyug-Gyo Rhee;Eui Seung Son;Jeon Geon Kang;Ji-Young Jeong;Pilseong Kang
    • Current Optics and Photonics
    • /
    • 제7권4호
    • /
    • pp.435-442
    • /
    • 2023
  • These days, the size of a reflective telescope has been increasing for astronomical observation. An additional optical system usually assists a large ground telescope for image analysis or the compensation of air turbulence. To guide collimated light to the external optical system through a designated path, a coudé mirror is usually adopted. Including a collimator, a coudé mirror of a ground telescope is affected by gravity, depending on the telescope's pointing direction. The mirror surface is deformed by the weight of the mirror itself and its mount, which deteriorates the optical performance. In this research, we propose an optimization method for the coudé mirror assembly for a 1-m class ground telescope that minimizes the gravitational surface error (SFE). Here the mirror support positions and the sizes of the mount structure are optimized using finite element analysis and the response surface optimization method in both the horizontal and vertical directions, considering the telescope's altitude angle. Throughout the whole design process, the coefficients of the Zernike polynomials are calculated and their amplitude changes are monitored to determine the optimal design parameters. At the same time, the design budgets for the thermal SFE and the mass and size of the mount are reflected in the study.

건축물의 단열성능 검증 시스템 구축을 위한 실험적 연구 (An Experimental Study to Establish a System for Vertifying the Insulation Performance of Buildings)

  • 김현진;최세진
    • 한국건축시공학회지
    • /
    • 제21권3호
    • /
    • pp.203-211
    • /
    • 2021
  • 최근 건축물의 에너지 사용 저감을 위한 단열 설계기준은 강화되고 있다. 단열공사는 건축물의 단위면적당 1차 에너지 소요량 저감을 위한 가장 효율적인 방법임에도 불구하고, 건축 시공 및 준공검사 과정에서 단열성능에 대한 평가(검사) 기준이 없는 실정이다. 본 연구는 열관류율 측정장비(TESTO 435)를 활용하여 공동주택의 외벽 열관류율을 간편하게 실험 할 수 있는 방법과 분석기법에 대한 기준을 구축하여 객관적인 데이터를 제공하는 데 목적이 있다. 실험 대상 외벽의 단위면적당 비열(열용량)이 20 kJ(m2·K)를 초과하여 ISO 9869-1에 적합한 종료 시점의 데이터를 평균법으로 분석했다. 3일 연속 열관류율 측정값은 설계값 대비 +5% 이내로 허용오차 범위 내로 수렴했고, 일자별 열관류율의 표준편차는 1-Day > 3-Day > 2-Day 순으로 작아졌고, 시간대별 열관류율 표준편차는 00:00~24:00 > 19:00~07:00 > 00:00~07:00 순으로 줄어 들었다. 특히, 측정일자별로 00:00~07:00 시간대의 열관류율 값은 설계값 대비 -3%~+2% 편차로 거의 일치하였다.

FMEA에 근거한 LV URD 케이블의 고장분석 (Failure Analysis of LV URD Cable based on FMEA)

  • 송길목;한운기;김영석;김선구;곽희로
    • 조명전기설비학회논문지
    • /
    • 제21권5호
    • /
    • pp.90-98
    • /
    • 2007
  • 본 연구의 목적은 고장 케이블(LV URD(low voltage underground) cable)의 원인을 밝히는데 있다. 분석방법은 외형패턴, 열패턴, 표면구조 분석, 열분석, 성분분포 등 다양한 분석기기를 이용하여 분석되었다. 국제기준과 사고케이블 제작회사가 제시하고 있는 규정이 일치하는지의 여부를 분석하였으며, 국내산 케이블과의 비교분석하였다. 그 내용을 요약하면 다음과 같다. (1) 사고케이블 자체의 절연성능을 저하시키는 요인으로 IEC 60502-1과 IEC 60811-1-1에 의한 절연피복의 최소 두께가 시방(specification)과 일치하지 알음을 확인하였다. (2) 적외선분광기에 의해 적외선흡광피크가 동일 재료에서 일치하지 않는 것으로 나타났다. (3) PVC bedding 부분이 열적으로 취약하여 장시간 현장에 노출되어 사용되는 경우 이와 유사한 패턴의 사고를 유발할 것으로 판단된다.

저열유속 조건의 복사열 노출에 따른 소방보호복의 열보호성능 측정에 관한 연구 (Study on the Thermal Protective Performance Measurements of Fire Fighter's Protective Clothing for Low Level Radiant Heat Exposures)

  • 이준경;방영준;방창훈;권정숙
    • 한국화재소방학회논문지
    • /
    • 제28권2호
    • /
    • pp.1-8
    • /
    • 2014
  • 보호복 섬유 및 재료의 개발을 통해 나아진 단열 성능을 제공함에도 불구하고 보호복의 화상 방지는 아직도 중요한 사항이다. 화염으로부터의 보호성능을 보장받기 위해서 보호복의 정확한 성능검증이 필요하며, 열보호 특성을 정확히 파악하기 위해 ISO 등은 시험방법을 표준화하여 제시하고 있다. 하지만 대부분의 경우, 높은 열유속 조건에 대해 보호복의 열보호 성능을 시험하는 것으로 되어 있어, 고열유속에 의한 시편의 파괴가 일어나기 쉽다. 그러므로 낮은 열유속 조건에서 보호복의 열보호 성능을 측정하는 방법이 필요하며, 본 연구에서는 낮은 열유속에 대한 열보호 성능을 측정할 수 있는 화상 및 통증유발시간에 기초한 개선된 RPP(복사열 보호 성능) 지수와 그의 측정방법을 제안하였다. 또한 제안된 열보호성능 측정 방법을 실험을 통해 확인하고, 보호복의 비정상열전달특성을 파악하였다. 또한 기존의 여러 가지 열보호성능지표들과 제안지표와의 관계를 제시하였다.

K1A1 전차 전차장 열상조준경의 관측창 재생을 위한 창 정비기술 연구 (A Study on Deport Maintenance Technology for Recycling Observation Window of the K1A1 Tank Commander's Primary Thermal Sight)

  • 최명진;변용완;양재경
    • 산업경영시스템학회지
    • /
    • 제42권3호
    • /
    • pp.89-94
    • /
    • 2019
  • K1A1 tank commander's primary thermal sight is a device that enables tank commanders to detect, identify, aim and track the target by observing targets in all directions during day, night and in situations of smokescreen and fog through $360^{\circ}$ rotation independent from the gunner's primary thermal sight and stabilizing the line of sight even under the vibrations occurring when the tank is standstill and moving. The main function of this device is to detect and process visible and thermal images and deliver the final images to the tank commander. One of the core parts to that end is the observation window (daytime/thermal image window). This core part is mounted at the entrance of the optical path for observing the target and plays the role of making visible light during the daytime and infrared light during the night pass through the target and transmitting the resultant images to the internal optical system of the tank commander's primary thermal sight. Such core parts have been selected as depot maintenance items so that they are replaced by new parts instead of being recycled when they are subjected to maintenance in most cases. That is, the military budget is wasted because such parts are replaced by new parts despite that they can be recycled for maintenance. Therefore, this study proposed a mounting tool for polishing and coating observation windows (daytime and thermal image window) using planar polishing equipment and DLC (Diamond-Like Carbon) coating equipment. In addition, this study presented an amendment (proposal) of the Depot Maintenance Work Request (DMWR) already published to verify the performance of recycled products including the establishment of inspection standards for recycling processes.

구조적 제약조건을 갖는 500 MW 석탄화력발전소 탈황설비의 성능개선 (Performance Enhancement of Flue Gas Desulfurization System with Structural Constraints in 500 MW Coal Fired Power Plants)

  • 김종성;유호선
    • 플랜트 저널
    • /
    • 제15권4호
    • /
    • pp.30-35
    • /
    • 2019
  • 미세먼지 감축에 대한 사회적 요구 증가와 강화되는 대기오염물질 배출허용기준을 충족시키기 위해 구조적 제약조건을 갖는 500 MW급 석탄화력발전소 탈황설비의 성능개선 방안을 제시하였다. 탈황설비 흡수탑을 통과하는 배기가스가 선회하도록 내부 설비를 개조하여 난류를 형성시켜 물질전달효율을 증가시키고 반응 면적 및 시간을 증가시킴으로써 황산화물 저감 및 먼지 포집 능력을 향상시킬 수 있었다. 개선결과 황산화물 제거효율은 91.61%에서 98.43%로 향상되었고 먼지 제거성능은 77.4%에서 87.08%로 향상되었다. 배출농도는 황산화물 7.85 ppm, 먼지 4.67 mg/㎥이 배출되어 2023년의 대기오염물질 배출허용기준인 황산화물 25 ppm, 먼지 5 mg/㎥을 만족하는 수준이다. 본 연구의 성능 개선 방식은 유사한 제약조건을 갖는 다른 석탄화력발전소에도 효과적으로 적용될 수 있으리라 기대된다.

Zr-based 비정질 합금의 비정질 특성에 미치는 Sn의 영향 (The Effect of Sn on the Glass Formation Ability of the Zr-based Amorphous Alloy)

  • 이병철;박흥일;박봉규;김성규
    • 한국주조공학회지
    • /
    • 제34권2호
    • /
    • pp.49-53
    • /
    • 2014
  • In commercial Zr-Nb-Cu-Ni-Al amorphous alloys, expensive element, Zr, was substituted to Sn which was cheaper one, and then, glass forming ability, compressive strength and hardness of them were estimated. Even though the Sn was added up to 1.5%, resulting phase was not changed to the crystalline form. It was confirmed by X-ray diffraction and thermal analyses. In the X-ray profiles, there were no peaks for crystalline phases and typical halo pattern for amorphous phase was appeared at the diffraction angle of $35^{\circ}{\sim}45^{\circ}$. Thermal analyses also showed that the Sn modified alloys were corresponded to the amorphous standards where ${\delta}T$(= Tx - Tg) and Trg(= Tg/Tm) affecting to the amorphous forming ability were more than 50K and 0.60 respectively. Compressive strengths were 1.77 GPa, 1.63 GPa, 1.65 GPa and 1.77 GPa for 0%Sn, 0.5%Sn, 1.0%Sn and 1.5%Sn respectively. Hardnesses of the Sn modified alloys were decreased from 752 Hv to 702 Hv in 1.0%Sn and recovered to 746 Hv in 1.5%Sn.

A Proposal on Evaluation Method of Neutron Absorption Performance to Substitute Conventional Neutron Attenuation Test

  • Kim, Jae Hyun;Kim, Song Hyun;Shin, Chang Ho;Choe, Jung Hun;Cho, In-Hak;Park, Hwan Seo;Park, Hyun Seo;Kim, Jung Ho;Kim, Yoon Ho
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.384-388
    • /
    • 2016
  • Background: For a verification of newly-developed neutron absorbers, one of guidelines on the qualification and acceptance of neutron absorbers is the neutron attenuation test. However, this approach can cause a problem for the qualifications that it cannot distinguish how the neutron attenuates from materials. Materials and Methods: In this study, an estimation method of neutron absorption performances for materials is proposed to detect both direct penetration and back-scattering neutrons. For the verification of the proposed method, MCNP simulations with the experimental system designed in this study were pursued using the polyethylene, iron, normal glass and the vitrified form. Results and Discussion: The results show that it can easily test neutron absorption ability using single absorber model. Also, from simulation results of single absorber and double absorbers model, it is verified that the proposed method can evaluate not only the direct thermal neutrons passing through materials, but also the scattered neutrons reflected to the materials. Therefore, the neutron absorption performances can be accurately estimated using the proposed method comparing with the conventional neutron attenuation test. Conclusion: It is expected that the proposed method can contribute to increase the reliability of the performance of neutron absorbers.

데이터센터의 그린화 성능 평가지표 개발에 관한 연구 (A Study on the Development of Assessment Indices about Greening Performance of Datacenter)

  • 안재근
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권4호
    • /
    • pp.29-42
    • /
    • 2011
  • 본 연구는 그린화 성능을 고려한 데이터센터의 평가지표를 개발하는 것을 목표로 한다. 이를 위해 다음과 같은 연구를 수행하고자 한다. 첫째, 데이터센터에 관련된 기준과 표준을 조사한다. 이 기준과 표준을 활용하여 그린화 성능을 고려한 데이터센터 모형을 제시한다. 이모형은 데이터센터에서 그린화 성능에 영향을 미치는 주요 구성요소들 간의 상관관계를 작업량-에너지-열로 표현한 것이다. 둘째, 이모형을 이용하여 그린화 성능 평가항목과 평가지표 그리고 평가방법을 제안한다. 셋째, 기기 수준과 데이터센터 수준의 그린화 성능을 평가하는 기준들에 대한 현황을 파악한다. 이를 통해 데이터센터의 그린화 성능에 영향을 미치는 요인을 고려할 수 있을 것이다. 마지막으로 기존의 그린화 성능 평가도구들을 조사하여, 제안하는 평가항목과 지표의 향후 필요한 개선점을 식별하고자 한다.