• Title/Summary/Keyword: Thermal management system

Search Result 382, Processing Time 0.033 seconds

Experimental Investigation of Variable Emittance Material Based on (La, Sr)MnO3 ((La, Sr)MnO3을 이용한 가변 방사율 소재에 관한 연구)

  • Han, Sunwoo;Choi, Bongsu;Song, Tae-Ho;Kim, Sun Jin;Lee, Bong Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.583-590
    • /
    • 2013
  • Variable emittance radiators can be used in a thermal management system in space because their total emittance changes depending on the temperature of the system. When the temperature of the system decreased, the emittance also decreased so as to minimize the heat loss to the environment. In contrast, when the temperature of the system increased, the emittance also increased such that radiation cooling could occur. Thermochromic materials, whose emittance is a function of the temperature, are often used in variable emittance radiators because no additional parts are needed. In this study, we fabricated a variable-emittance coating by using a sol-gel method based on LSMO ($La_{1-x}Sr_xMnO_3$) and experimentally characterized the emittance change with respect to temperature. Furthermore, we also examined the stability of LSMO film in space environments by exposing it to extremely low pressure and temperature.

A Numerical Analysis on Transient Fuel temperatures in a Military Aircraft under Non-operating Ground Static Condition (지상 정적 상태에서의 항공기내 연료온도변화에 대한 수치해석)

  • 김영준;김창녕
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2003
  • A numerical study was performed on the transient fuel temperatures of a military aircraft stationed under non-operating static condition. Numerical calculation was peformed by an explicit method using modified Dufort-Frankel scheme. It was assumed that the non-operating aircraft is subjected to repeated daily cycles of air temperature with the solar radiation and wind speed corresponding to the 1 % hot day ambient condition. And, the aircraft was assumed to be in turbulent flow. The convective heat transfer coefficient for turbulent flow on the flat plate suggested by Eckert was employed to calculate heat transfer between the aircraft surface and the ambience. The energy conservation equation on fuel was used as governing equation for this analysis. As a result of this analysis, the wing tank temperature showed the highest temperature and the largest rate of temperature changes among fuel tanks. The results of this analysis could be used as initial foe] temperatures for analysis of the transient fuel temperatures in various flight missions. Also, this analysis method could be used to analysis and design of an aircraft thermal energy management system.

A Novel of Solar Heat Collection Device Prototype using Parabolic based on Solar Light Tracking (태양광 추적기반의 파라볼릭을 이용한 태양열 집열장치 프로토타입에 관한 연구)

  • Jung, Se-Hoon;Sim, Chun-Bo;Park, Sung-Kyun;Kim, Jong-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.4
    • /
    • pp.411-420
    • /
    • 2016
  • Efforts have continued in recent years to research and develop new alternative energy sources to replace coal and oil. These days interest is exploding in new pollution-free renewable energy due to the rising prices of finite energy sources. In the field of solar energy, one of new renewable energy that has been actively researched and commercialized, research efforts have been focused on solar light energy, whose efficiency has, however, reached a saturation point already. Thus, this paper proposed a solar tracking-type parabolic heat collection device to utilize solar thermal energy rather than solar light energy. The proposed device was designed in a parabolic form to collect solar heat effectively. The investigator made its prototype by incorporating a five-axis censor-based solar tracking technology in it to sense changes to the location of the sun according to the seasons and periods. In addition, an administrator interface was designed and implemented for the efficient management of heat collection device.

Wind Energy Interface to Grid with Load Compensation by Diode Clamped Multilevel Inverters

  • Samuel, Paulson;Naik, M. Kishore;Gupta, Rajesh;Chandra, Dinesh
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.271-281
    • /
    • 2014
  • Fluctuating wind conditions necessitate the use of a variable speed wind turbine (VSWT) with a AC/DC/AC converter scheme in order to harvest the maximum power from the wind and to decouple the synchronous generator voltage and frequency from the grid voltage and frequency. In this paper, a combination of a three phase diode bridge rectifier (DBR) and a modified topology of the diode clamped multilevel inverter (DCMLI) has been considered as an AC/DC/AC converter. A control strategy has been proposed for the DCMLI to achieve the objective of grid interface of a wind power system together with local load compensation. A novel fixed frequency current control method is proposed for the DCMLI based on the level shifted multi carrier PWM for achieving the required control objectives with equal and uniform switching frequency operation for better control and thermal management with the modified DCMLI. The condition of the controller gain is derived to ensure the operation of the DCMLI at the fixed frequency of the carrier. The converter current injected into the distribution grid is controlled in accordance with the wind power availability. In addition, load compensation is performed as an added facility in order to free the source currents being fed from the grid of harmonic distortion, unbalance and a low power factor even though the load may be unbalanced, non-linear and of a poor power factor. The results are validated using PSCAD/EMTDC simulation studies.

Study on Improvement in Reliability of Analysis for VOCs and Aldehydes (대기 중 휘발성유기화합물질 및 알데하이드의 분석 신뢰도 향상에 관한 고찰)

  • Lee M.D.;Lee S.U.;Lim Y.J.;Kim Y.M.;Kim S.Y.;Moon K.J.;Han J.S.;Chung I.R.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.4
    • /
    • pp.468-476
    • /
    • 2006
  • Hazardous air pollutants (HAPs) have high toxicity and bioaccurnulation potentials into human body even inbsmall amount (levels of ng/$m^3$). As the levels of HAPs might be controversial, it has been become essential to establish the analysis method for correct results. In this study, various analysis methods of VOCs and Aldehydes were compared in order to select the proper methods in our condition. Sampling and analysis method of VOCs were followed to EPA TO-14a and TO-17. VOCs were collected in absorption tube and separated by thermal desorption unit then analyzed by GC/MSD. Aldehydes were sampled in DNPH-cartridge and extracted into solution then analyzed by HPLC as the same condition of EPA TO-13a. This study also shows the results of QA/QC system of selected methods. Some experiments could be improving the data assurance blank test, calibration check, repetition precision check, the determination of detection limit and reproducibility of the retention time. Precisions of VOCs and aldehydes were ranged in 2$\sim$9% and 1$\sim$4% RSD, respectively. Recovery rate of VOCs showed variable ranges from 60 to 133.5%. MDL of VOCs and aldehydes were 0.044$\sim$0.284 ppb and 0.14$\sim$1.02 ng, respectively.

Development of 80kW Bi-directional Hybrid-SiC Boost-Buck Converter using Droop Control in DC Nano-grid (DC 나노그리드에서 Droop제어를 적용한 80kW급 양방향 하이브리드-SiC 부스트-벅 컨버터 개발)

  • Kim, Yeon-Woo;Kwon, Min-Ho;Park, Sung-Youl;Kim, Min-Kook;Yang, Dae-Ki;Choi, Se-Wan;Oh, Seong-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.360-368
    • /
    • 2017
  • This paper proposes the 80-kW high-efficiency bidirectional hybrid SiC boost/buck converter using droop control for DC nano-grid. The proposed converter consists of four 20-kW modules to achieve fault tolerance, ease of thermal management, and reduced component stress. Each module is constructed as a cascaded structure of the two basic bi-directional converters, namely, interleaved boost and buck converters. A six-pack hybrid SiC intelligent power module (IPM) suitable for the proposed cascaded structure is adopted for high-efficiency and compactness. The proposed converter with hybrid switching method reduces the switching loss by minimizing switching of insulated gate bipolar transistor (IGBT). Each module control achieves smooth transfer from buck to boost operation and vice versa, since current controller switchover is not necessary. Furthermore, the proposed parallel control using DC droop with secondary control, enhances the current sharing accuracy while well regulating the DC bus voltage. A 20-kW prototype of the proposed converter has been developed and verified with experiments and indicates a 99.3% maximum efficiency and 98.8% rated efficiency.

Evaluation of Body Movement during Sleep with a Thermopile, Wavelets and Neuro-fuzzy Reasoning

  • Yoon, Young-Ro;Shin, Jae-Woo;Lee, Hyun-Sook;Jose C.Principe
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.5-10
    • /
    • 2004
  • Body movement is one of the important factors in sleep analysis. In this study, a thermopile detector with four channels was implemented as a non-contacting detector of body movement in sleep. Using a thermopile mathematical model and several frames of thermal images, the possibility of detecting body movement was evaluated. Instant body movement signals were evaluated for the upper, lower, and entire body using the Haar wavelet. This decomposition shows the points in time when the upper-body or lower-body movement occurred and the level of body movement. Additionally, partial body movement was decomposed in head-only, whole body, and leg-only movement using the ANFIS algorithm. Finally, three subject's data were evaluated for 60 minutes, and the detection rates of instant and partial body movement, on average, were 96.3% and 89.2%, respectively.

Performance Analysis of Off-Gas/Syngas Combustor for Thermal Management of High Temperature Fuel Cell System (고온형 연료전지 열관리를 위한 배기가스 연소기 성능시험)

  • Lee, Sang-Min;Lee, Youn-Hwa;Ahn, Kook-Young;Yu, Sang-Seok
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.3
    • /
    • pp.193-200
    • /
    • 2010
  • Anode off-gas of high temperature fuel cell still contains combustible components such as hydrogen, carbon monoxide and hydrocarbon. In this study, a catalytic combustor has been applied to the high temperature fuel cell so that the combustion of anode-off gas can be boosted up. Since the performance of catalytic combustor directly depends on the combustion catalyst, this study is designed to perform the experimental investigation on the combustion characteristics of the three commercial catalysts with a different composition. Screening tests with three catalysts are preceded before the performance examination since it is necessary to determine the most suitable catalyst for design configuration of the catalytic combustor. The performance analysis shows that methane conversion rate strongly depends on gas hourly space velocity (GHSV) as well as inlet gas temperature. Additionally, the GSHV optimization results show that the optimum GHSV will be in the range between 18,000 $hr^{-1}$ and 36,000 $hr^{-1}$. It is also shown that the minimum inlet temperature of catalytic reaction of methane is from $100^{\circ}C$ to $150^{\circ}C$.

Numerical Study on the Heat Transfer Characteristics of 360 Wh Li-ion Battery Pack for Personal Mobility (360 Wh급 퍼스널 모빌리티용 리튬이온 배터리 팩의 열전달 특성에 관한 연구)

  • Kim, Dae-Wan;Seo, Jae-Hyeong;Kim, Hak-Min;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.1-7
    • /
    • 2017
  • This study numerically evaluates the heat transfer characteristics of a 360-Wh Li-ion battery pack. The analysis was done in ANSYS CFX using different cell arrangements, cell holders, and case materials for a personal mobility device program. A total of four cases of cell arrangements were considered, along with various materials for both the cell holder and the case, such as polypropylene, aluminum, and magnesium alloy. Out of the four cell arrangements, model 2 showed the best heat transfer performance, while aluminum showed the best heat transfer performance for the cell holder and case.

Review on the Effectiveness of Apartments According to Insulation Reinforcement of Energy Saving Design Standard - Energy Cost Analysis of Space Heating and Domestic Hot Water - (에너지절약설계기준의 단열 변화에 따른 공동주택 실효성 검토 - 난방 및 급탕에너지 사용금액 분석 -)

  • Kim, Ji-hyeon;Lim, Hee-won;Lee, Hyun-seung;Shin, U-cheul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.1
    • /
    • pp.173-178
    • /
    • 2020
  • In this study, we analyzed space heating and domestic hot water(DHW) charges from 2017 to 2018 for 151,206 households in 202 apartment complexes built from 1997 to 2016, in order to evaluate the effectiveness of Korea's insulation standards reinforcement. The applied insulation standards were revised three times(in 1987, 2001 and 2010). We used the Anderson-Darling test to review the normality of the space heating and DHW charges. As a result, each p-value was greater than 0.05 and it followed the normal distribution. The annual average space heating charges per unit area of apartments with the 1987 insulation standards were 5,237₩/㎡a in 2017 and 5,328₩/㎡a in 2018. The heating charges with the 2001 standards were 4,827₩/㎡a in 2017 and 4,817₩/㎡a in 2018. Compared to previous standards(1987 standards), heating charges decreased by 7.8% and 9.6%. Also the heating charges with the 2010 standards were 3,683₩/㎡a in 2017 and 3,734₩/㎡a in 2018. Compared to previous standards(2001 standards), heating charges decreased by 24.3% and 21.5%. On the other hand, compared to each previous standards, DHW charges were decreased by 12.2%, 13.6% or increased by 4.6%, 6.9%, which means there's no correlation between insulation standards reinforcement and DHW charges.