• 제목/요약/키워드: Thermal interference

검색결과 153건 처리시간 0.022초

척추후관절가동술이 만성요통환자의 통증과 요부안정성에 미치는 영향 (The Effects of Sustained Natural Apophyseal Glides on Pain and Lumbar Stability in Patient with Chronic Low Back Pain)

  • 이영화;권원안;이재홍;김준현;배성수
    • 대한물리의학회지
    • /
    • 제3권3호
    • /
    • pp.203-213
    • /
    • 2008
  • Purpose : The purpose of the study was to investigate the effects of sustained natural appophyseal glides (SNAGS) on pain and lumbar stability in patients with chronic low back pain. Methods : The subjects were assigned randomly devided SNAGS group(n=18) and control group(n=18). The SNAGS group received Infrared(IR) used thermal therapy for 20minutes, Interference current therapy(ICT) used electrical therapy for 10minutes and SNAGS for 10minutes to 15minutes. The control group received IR used thermal therapy for 20minutes, ICT used electrical therapy for 10minutes and active stretching exercise for 10minutes to 15minutes. The visual analogue scale(VAS) and lumbar stability were measured at pre-treatment and post-treatment. Results : The results of this study were summarized as follows : 1. The VAS score of SNAGS group and control group was significantly within-subjects pre-test and post-test (p<.05), there was significantly difference between-subjects on each groups(p<.05). 2. The SNAGS group was significantly increased in variation of lumbar stability on $0^{\circ}$, $180^{\circ}$, $90^{\circ}$, $-90^{\circ}$, $45^{\circ}$, $-45^{\circ}$, $135^{\circ}$ and $-135^{\circ}$ within-subjects pre-test and post-test(p<.05), but The control group wasn't significantly increased in variation of lumbar stability on $0^{\circ}$, $180^{\circ}$, $90^{\circ}$, $-90^{\circ}$, $45^{\circ}$, $-45^{\circ}$, $135^{\circ}$ and $-135^{\circ}$ within-subjects pre-test and post-test(p>.05). There was significantly difference between-subjects on each groups(p<.05). Conclusion : In conclusion, SNAGS found that effective to decrease of pain and increase of lumbar stability. Therefore, the results of this study suggests that SNAGS is beneficial treatment for chronic low back pain.

  • PDF

조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 - (The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제38권2호
    • /
    • pp.1-8
    • /
    • 2010
  • 도시 옥외공간에서 조경 포장면의 종류에 따른 하절기 옥외공간의 온열쾌적성 차이 발생 여부를 차광과 통풍이 배제된 조건에서 실제 온도와 상대습도의 측정을 통하여 검증하였다. 잔디, 석재잔디블럭, 중공잔디블럭, 석재블럭, 사고석, 소형고압블럭, 점토벽돌, 나지, 쇄석, 수밀콘크리트 등 총 10가지 의 인공적으로 조성된 포장면을 대상으로 저항측정식 센서들을 이용하여 2009년 6월부터 9월까지 매 분 단위로 측정하고, 기상청 관측자료를 기준으로 일 최고 기온이 $30^{\circ}C$ 이상인 26일 동안의 정오부터 오후 3시까지의 자료를 분석하였으며, 주요 내용은 다음과 같다. 지면 온도는 포장재의 종류에 따라서 차이가 발생하였는데, 잔디면의 온도가 가장 높았고, 콘크리트의 온도가 상대적으로 낮은 것으로 나타났다. 전체 시험구의 평균 지면온도는 $40.1^{\circ}C$로 분석되었는데, 이는 기상대 관측 최고 기온보다 $9^{\circ}C$ 이상 높은 것이었으며, 최고 온도는 약 $50^{\circ}C$ 이상까지 상승하는 것으로 나타났다. 지면으로부터 1.2m 높이의 온열쾌적성지수인 습구흑구온도(Wet-Bulb Grlobe Temperature: WBGT)는 포장재에 따라서 통계적으로 유의한 차이가 있는 것으로 분석되었으며, 잔디포장면이 가장 높게 나타났고, 석재 또는 콘크리트블럭과 잔디를 혼합한 포장면이 가장 낮게 나타났다. 그러나 이들 측정값은 인간이 느끼는 쾌적한 온도 범위를 심각한 수준으로 넘어선 상태의 값으로 실제 환경에서의 체감 온열쾌적성과 직접 연관시키기는 곤란하다. 이러한 결과는 이상고온에 견디지 못하는 잔디의 생육 특성과 통풍과 차광이 배제된 시험구의 특성, 그리고 남중고도 가 높은 한낮의 데이터만을 분석 대상으로 삼은 점 등이 복합적으로 영향을 미친 결과로 해석되었다. 결론적으로 본 연구를 통해서 통풍과 차광이 배제된 하절기 한낮의 옥외공간에서는 인간이 체감하는 온열쾌적성에 포장재 변화가 미치는 영향은 미미하며, 오히려 통풍과 차광이 미치는 영향이 매우 중요하다는 것을 파악할 수 있었다.

구강 악안면 영역의 생체 흡수성 고정판 사용에 관한 임상 연구 (A CLINICAL STUDY OF BIODEGRADABLE PLATES AND SCREWS IN ORAL AND MAXILLOFACIAL SURGERY)

  • 김일규;박승훈;장금수;양정은;장재원;사시카라 바라라만
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권6호
    • /
    • pp.451-458
    • /
    • 2009
  • Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.

가변 통기성 의복을 위한 스마트 개폐장치 개발: 양방향 작동 액추에이터 제작을 위한 일방향 형상기억합금 와이어의 최적 직경 및 전압인가 단위시간의 도출 (Development of Smart Switchgear for Versatile Ventilation Garments: Optimum Diameter and Voltage Application Unit Time of One-way Shape Memory Alloy Wire for a Bi-directional Actuator)

  • 김상구;김민성;유신정
    • 감성과학
    • /
    • 제21권2호
    • /
    • pp.137-144
    • /
    • 2018
  • 본 연구에서는 가변 통기성 스마트 의류의 제작을 위해 필요한 형상기억합금 액추에이터의 작동 조건을 파악하였다. 의복의 개방, 폐쇄와 같은 양방향 작동 시 형태 변형 시에만 전력을 소모하는 저전력 소모 액추에이터 개발을 위해 복수 채널의 일방향 형상기억합금을 이용하여 스위치로 작동되는 액추에이터를 설계하였으며 가장 효율적으로 작동할 수 있는 와이어의 직경과 전압인가 단위시간을 도출하였다. 선행연구 결과 도출된 양방향 작동이 가능한 일방향 형상기억합금의 직경 범위 내에서 Arduino 스위치를 제작하여 3.7V 전압인가 시 변화량을 분석한 결과 $0.4{\Phi}$의 액추에이터가 가장 적합한 것으로 나타났다. $0.4{\Phi}$ 형상기억합금와이어를 사용한 양방향작동 액추에이터의 개방, 폐쇄에 필요한 최적전압인가 시간을 도출하기 위해 액추에이터의 최대개방, 최소폐쇄 도달 전압인가 시간으로부터 50ms씩 감소, 증가 시키며 냉각 후 액추에이터의 내경을 비교하는 방식으로 측정한 결과 개방 동작에 필요한 최적 전압인가 단위시간은 4,100ms로 나타났다. 각 채널간의 발열에 의한 간섭을 최소화하기 위한 양방향간 작동 시 필요 딜레이 분석을 위해 상온에서 형상기억합금에 최적 전압입가 시간인 4.1초 동안 전원을 공급하고 가열 후 냉각까지의 과정을 열화상카메라로 촬영하여 형상기억합금 와이의 온도가 냉각시의 상변태온 이하로 하강하는 시점을 파악한 결과, 액추에이터의 양방향간 작동 딜레이는 1.8초 이상이 확보되어야 함을 파악할 수 있었다.

다중벽 탄소나노튜브를 함유한 PC/ABS 복합재의 마모 특성 및 다중벽 탄소나노튜브의 유출 평가 (Evaluation of MWCNT Exposure and the Wear Characteristics of MWCNT-containing PC/ABS Composites)

  • 이현우;김경식;이재혁;김효섭;김재호;오동훈;류상효;장영찬;김재현;이학주;김광섭
    • Tribology and Lubricants
    • /
    • 제30권5호
    • /
    • pp.278-283
    • /
    • 2014
  • Carbon nanotubes (CNTs) are used in various composite materials to enhance electrical, thermal and mechanical properties of composite materials. In this study, we investigate the wear characteristics of polycarbonate/acrylonitrile-butadiene-styrene (PC/ABS) blends containing multi-walled carbon nanotubes (MWCNTs). PC/ABS blends are commonly used in many industrial applications such as cellular phones and display cases and MWCNTs have been added to the PC/ABS blends to improve their electromagnetic interference shielding (EMS). We performed wear tests on PC/ABS blends containing MWCNTs under reciprocating linear sliding conditions with chrome steel balls as a counterpart material. The normal loads were 10, 30, 50, 70, 100 N, the sliding speed was 10 mm/s, the stroke length was 15 mm, and the tests lasted 900 s. The MWCNTs included in the PC/ABS blends lower the wear volume and friction coefficient of the composites. We analyzed the wear debris collected from the composites during the tests in terms of the MWCNT concentration using inductively coupled plasma optical emission spectroscopy. The results show that the quantity of MWCNTs in the debris is proportional to the concentration of MWCNTs in the composite, indicating that the exposure of the MWCNTs to environments by wear could be increased with their concentration in the composite.

등가열교환율을 적용한 현장타설 에너지파일 설계법 (Design Method for Cast-in-place Energy Pile Considering Equivalent Heat Exchange Rate)

  • 민선홍;박상우;정경식;최항석
    • 대한토목학회논문집
    • /
    • 제33권3호
    • /
    • pp.1049-1061
    • /
    • 2013
  • 본 연구에서는 현장타설 에너지파일의 열교환 파이프 배치 형태별 열교환율을 전산유체해석 프로그램(FLUENT)을 이용하여 평가하고, 이를 이용하여 에너지파일의 설계법을 제시하였다. 등가열교환율을 산정하기 위해 동일한 현장타설말뚝 제원에 대해 열교환파이프 배치 형태를 W-형(직렬), 복합 U-형(병렬 4쌍), 나선형의 3가지로 고려하였다. 건물측 부하조건은 여름철 냉방운용를 모사하기 위해 순환수의 에너지파일 유입온도, 즉 히트펌프 유출온도(Leaving water temperature, LWT)를 $35^{\circ}C$로 일정하게 유지하여 에너지파일 유출온도, 즉 히트펌프 유입온도(Entering water temperature, EWT) 변화를 관찰하였다. 지반에 최대 가상부하를 적용한 경우(100시간 연속 냉방부하 조건)에는 3가지 열교환기 형태가 유사한 열교환율을 보인 반면, 실제 히트펌프 가동에 의한 건물 냉방운용을 모사하기 위해 간헐적으로 일일 8시간 운용-16시간 정지를 7일간 반복 해석한 경우에는 W-형(직렬연결)과 복합 U-형(병렬 4쌍) 열교환기는 유사한 열교환율을 보이나, 나선형 열교환기는 파이프 루프 상호 간 열간섭으로 인해 복합 U-형 열교환기에 비해 약 86%의 열교환율을 갖는 것으로 평가되었다. 전산유체해석에 의해 계산된 열교환파이프 배치 형태별 에너지파일의 등가열교환율을 에너지파일 설계프로그램(PILESIM2)에 적용하여 다양한 형상의 현장타설 에너지파일에 대한 설계법과 대표적인 설계변수에 대한 설계도표를 제시하였다.

Formation and Characteristics of the Fluorocarbonated SiOF Film by $O_2$/FTES-Helicon Plasma CVD Method

  • Kyoung-Suk Oh;Min-Sung Kang;Chi-Kyu Choi;Seok-Min Yun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.77-77
    • /
    • 1998
  • Present silicon dioxide (SiOz) 떠m as intennetal dielectridIMD) layers will result in high parasitic c capacitance and crosstalk interference in 비gh density devices. Low dielectric materials such as f f1uorina뼈 silicon oxide(SiOF) and f1uoropolymer IMD layers have been tried to s이ve this problem. I In the SiOF ftlm, as fluorine concentration increases the dielectric constant of t뼈 film decreases but i it becomes unstable and wa않r absorptivity increases. The dielectric constant above 3.0 is obtain어 i in these ftlms. Fluoropolymers such as polyte$\sigma$따luoroethylene(PTFE) are known as low dielectric c constant (>2.0) materials. However, their $\alpha$)Or thermal stability and low adhesive fa$\pi$e have h hindered 야1리ru뚱 as IMD ma따"ials. 1 The concept of a plasma processing a찌Jaratus with 비gh density plasma at low pressure has r received much attention for deposition because films made in these plasma reactors have many a advantages such as go여 film quality and gap filling profile. High ion flux with low ion energy in m the high density plasma make the low contamination and go어 $\sigma$'Oss피lked ftlm. Especially the h helicon plasma reactor have attractive features for ftlm deposition 야~au똥 of i앙 high density plasma p production compared with other conventional type plasma soun:es. I In this pa야Jr, we present the results on the low dielectric constant fluorocarbonated-SiOF film d밑JOsited on p-Si(loo) 5 inch silicon substrates with 00% of 0dFTES gas mixture and 20% of Ar g gas in a helicon plasma reactor. High density 띠asma is generated in the conventional helicon p plasma soun:e with Nagoya type ill antenna, 5-15 MHz and 1 kW RF power, 700 Gauss of m magnetic field, and 1.5 mTorr of pressure. The electron density and temperature of the 0dFTES d discharge are measUI벼 by Langmuir probe. The relative density of radicals are measured by optic허 e emission spe따'Oscopy(OES). Chemical bonding structure 3I피 atomic concentration 따'C characterized u using fourier transform infrared(FTIR) s야3띠"Oscopy and X -ray photonelectron spl:’따'Oscopy (XPS). D Dielectric constant is measured using a metal insulator semiconductor (MIS;AVO.4 $\mu$ m thick f fIlmlp-SD s$\sigma$ucture. A chemical stoichiome$\sigma$y of 야Ie fluorocarbina$textsc{k}$영-SiOF film 따~si야영 at room temperature, which t the flow rate of Oz and FTES gas is Isccm and 6sccm, res야~tvely, is form려 야Ie SiouFo.36Co.14. A d dielec$\sigma$ic constant of this fIlm is 2.8, but the s$\alpha$'!Cimen at annealed 5OOt: is obtain려 3.24, and the s stepcoverage in the 0.4 $\mu$ m and 0.5 $\mu$ m pattern 킹'C above 92% and 91% without void, res야~tively. res야~tively.

  • PDF

DECOVALEX-2019 Task G 소개: EDZ Evolution - 굴착손상영역 평가를 위한 수리전도도 및 투수량계수 측정의 신뢰도, 적합성 및 중요성 (An Introduction to the DECOVALEX-2019 Task G: EDZ Evolution - Reliability, Feasibility, and Significance of Measurements of Conductivity and Transmissivity of the Rock Mass)

  • 권새하;민기복
    • 터널과지하공간
    • /
    • 제30권4호
    • /
    • pp.306-319
    • /
    • 2020
  • 사용후핵연료의 심층처분 사업에서는 처분장 주변 모암의 수리역학적 성능을 저하시키는 굴착손상영역의 특성화가 중요하다. 이에 DECOVALEX-2019 프로젝트의 Task G에서는 균열암반 수치해석 모델을 구축한 후 암반 주변의 굴착손상영역의 수리역학적 거동을 모사하고, 구축한 모델로 처분장의 운영 시에 장기적으로 야기될 수 있는 추가적인 수리학적 변화를 관찰하였다. 과업의 첫 번째 단계에서는 2차원 균열암반 모델을 구축하여 수치해석 기법의 특성을 파악하고, 두 번째 단계에서는 3차원 균열암반 모델로 확장 후 스웨덴 애스푀 지하연구시설(Äspö Hard Rock Laboratory) 내 TAS04 간섭시험 결과와 비교하여 수치해석 모델을 검증한 후, 세 번째 단계에서는 열과 빙하 하중에 의한 영향을 반영하여 균열암반의 수리역학적 반응을 순차적으로 확인하였다. 과업의 전 과정에서 유한요소법과 개별요소법으로 균열암반에서의 수리역학적 분석을 수행하였으며, 균열의 기하학적 특성을 반영 및 굴착손상영역을 반영하는 과정에서 각 수치해석 기법에 따라 다양한 접근방법으로 고려하였다. 따라서 본 연구는 향후 결정질 균열암반에 사용후핵연료 처분장을 계획할 시 수치해석 단계에서 채택될 수 있는 다양한 접근 방법과 고려해야 할 사항들을 제시할 수 있을 것으로 전망한다.

하나로의 즉발감마선 방사화분석 장치를 이용한 붕소의 정량에 대한 연구 (Study on Determination of Boron using the PGAA Facility at HANARO Research Reactor)

  • 정용삼;조현제;문종화;김선하;김영진
    • 분석과학
    • /
    • 제16권5호
    • /
    • pp.391-398
    • /
    • 2003
  • 하나로의 즉발감마선 방사화분석 장치를 이용하여 생물시료중의 붕소의 정량을 위한 기초연구를 수행하였다. 측정조건에 대한 특성조사를 위해 시료에 대한 중성자 조사 위치에서 중성자속 및 균질도를 측정하였다. 시료위치에서 열중성자 빔의 크기가 $2{\times}2cm^2$ 되도록 집속하였으며, 측정된 선속은 $1.0{\sim}6.5{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$ 범위를 나타냈으며, 중심부로부터 반경 4.5 mm 이내 및 9 mm 이내에서 각각 $5.77{\pm}0.71{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$, $4.68{\pm}1.64{\times}10^7n{\cdot}cm^{-2}{\cdot}s^{-1}$이었다. 따라서 양질의 균일한 조사를 위해서 시료의 크기를 10 mm 이내로 조정하였다. 검출 시스템은 컴프턴 산란에 의한 백그라운드 요인을 억제하고 분석감도를 높이기 위해 설계되었으며, 감마선 계측 시스템의 에너지 교정과 컴프턴 억제율을 조사하기 위해 NaCl 표준체를 이용하여 단일 및 컴프턴 모드로 백그라운드를 측정하였다. 또한 정확한 붕소의 측정을 위해 시료의 매질효과로서 발생하는 분광학적 Na의 472 keV 피이크에 대한 간섭효과를 결정하였으며, 세 가지 인증표준물질 (NIST SRM 1570a, 1547, 1573a)을 이용한 붕소농도 측정시험을 두 가지 모드로 실시한 후 결과를 비교하였다.

송전선로 자동추적 카메라 짐벌 및 154 kV 송전선로 현장시험 (Auto-Tracking Camera Gimbal for Power Line Inspection Drone and its Field Tests on 154 kV Transmission Lines)

  • 김석태;박준영;이재경;함지완
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.149-156
    • /
    • 2019
  • 송전선로 현장에서는 2017년도부터 송전선로 순시 점검에 드론을 활용하기 시작했다. 전력연구원의 송전선로 드론점검 시범적용을 시작으로 현재 4개 지역본부에서 전력연구원이 개발한 송전선로 드론순시 점검기술을 현장에서 사용 중에 있다. 현재 점검드론 지상관제시스템을 활용하여 드론은 자동비행하고 광학줌 카메라와 열화상카메라의 짐벌은 현장작업자가 수동으로 조종하여 송전선을 촬영하는 체계로 운영되고 있다. 송전선로 드론점검은 작업자가 접근하기 어려운 지역, 예를 들면, 강횡단지역, 해월구간, 산간지역 등에 위치한 송전선로가 그 주요대상이다. 특히 산간지역의 경우, 점검드론과 지상관제시스템 사이에 장애물이 많고 철탑 구조물이 전파간섭을 일으켜 간헐적으로 통신장애가 일어나곤 한다. 이런 통신장애는 계획된 경로로 비행하는 점검드론의 자동비행에는 영향이 없지만, 카메라 짐벌의 제어에는 영향을 주어 제어불능 상태로 되는 경우가 있다. 또한, 카메라 짐벌의 제어가 원활하더라도 통신장애로 인해 발생하는 간헐적 영상 끊김 현상은 현장작업자가 점검대상을 잃어 카메라 짐벌 조정을 불가능하게 한다. 그러므로 본 논문에서는 간헐적 짐벌제어 끊김이나 영상 끊김 현상이 발생하더라도 지속적으로 송전선을 점검할 수 있도록 하기 위하여 딥러닝 기반 영상인식을 통해 송전선을 자동으로 추적하는 카메라 짐벌을 개발하여 현장 시험한 결과를 소개하고자 한다.