• 제목/요약/키워드: Thermal interference

검색결과 151건 처리시간 0.027초

고토크 복합재 프로펠러 샤프트 개발에 관한 연구 (A Study on the Development of High Torque Composite Propeller Shaft)

  • 박지상;황경정;김태욱;윤형석
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.22-26
    • /
    • 2002
  • The goal of this study is to replace the current forward 2-piece propeller shaft of 8 ton large truck made of steel with 1-piece composite propeller shaft. A low cost Glass/Epoxy composite propeller shafts were successfully developed, which satisfy requirements such as the capacity of static torque transfer, fatigue strength and bending natural frequency. Devising secure joining method of a composite tube and metal yoke was the most critical issue in successful development of a high torque composite propeller shaft. In this study, joining method using thermal interference fit was adopted for composite to metal joint. Optimum conditions of heating temperature and interference level of thermal interference fit were determined from thermal stress analysis using 3D finite element method. Static torsion test, fatigue test, RPM and balance test were performed to verify the design.

  • PDF

열응력을 고려한 고무 오일시일 해석 (Coupled Thermal-Mechanical Analysis of Rubber Oil Seals)

  • 김청균;전인기
    • Tribology and Lubricants
    • /
    • 제10권2호
    • /
    • pp.39-42
    • /
    • 1994
  • This paper deals with the distributions of the contact stress in oil seals. The distributions of the contact stress due to the temperature effects are analyzed for various values of the interference for a nitrile rubber seal. The calculated FEM results show that the relative maximum stresses occur at the contacting area against the shaft, the flex zone, and the contacting area of the garter spring grooves. Using the coupled temperature-stress FEM a nalysis, the contact force of a radial lip seal with and without the garter spring are studied as a function of shaft diameter. The calculated results of mechanical analysis show good correspondence with those of the coupled thermal-mechanical analysis method except small values of the interference. And the calculated results indicated that the thermal stresses only have a very minor influence on the deformed shape of the lip seal as the interference increases. But the coupled temperature-stress analysis will be very useful tool to predict the contact behaviors of rubber lip seals for small values of the interference.

주변 지반의 열전도도를 고려한 PHC 에너지파일의 열 거동 및 파일 간 열 간섭 현상에 대한 수치해석 연구 (Thermal Behavior of Energy Pile Considering Ground Thermal Conductivity and Thermal Interference Between Piles)

  • 고규현;윤석;박도원;이승래
    • 대한토목학회논문집
    • /
    • 제33권6호
    • /
    • pp.2381-2391
    • /
    • 2013
  • 일반적으로 에너지파일의 열적 성능에 영향을 주는 중요한 인자로 지반의 열 물성, 열 교환기 형태, 운용방법, 파일 간 열 간섭 등이 고려될 수 있다. 본 연구에서는 지반의 실제 조건을 반영한 수치모델을 통해 이들 인자들이 미치는 영향을 살펴보았다. 지반의 포화 정도에 따라서 파일의 열 교환율은 최대 3배까지 차이를 보였으며, 열 저항은 최대 8.7%의 차이가 발생하였다. 또한 열 교환기 유형이 파일의 열 성능에 영향을 주며, 3U-Type이 W나 U-Type에 비해 상대적으로 높은 열 효율을 보였다. 운용방법에 있어서, 부분가동 시(8시간 가동, 16시간 휴지) 연속가동에 비해서 약 20%의 열효율을 보전할 수 있으며, 장기적인 열 축적현상을 방지하는데 유리하다. 지반의 조건에 따라 군 말뚝에 의한 열 간섭 정도가 달라지는데, 지반이 포화상태에서 건조 상태로 갈수록 군 말뚝에 의한 열 간섭효과는 감소한다. 일반적인 지반조건에서 열 교환 감소율 1%미만을 유지하는 적정 이격 거리는 U-Type에서 최대 3.2D, W-Type에서 최대 3.6D, 3U-Type에서 최대 3.7D로 산정되었다.

압입공정에서 기어의 이끝 및 이뿌리 변형량 예측 (A Prediction of the Amount of Dimensional Deformation of Addendum and Dedendum after Shrink Fitting Process)

  • 김지산;황범철;배원병;김철
    • 한국정밀공학회지
    • /
    • 제28권4호
    • /
    • pp.463-473
    • /
    • 2011
  • The warm shrink fitting process is generally used to assemble automobile transmission parts (shaft/gear). But the fitting process can cause the dimensions of addendum and dedendum of the gear to change with respect to the fitting interference and the profile of the gear. As a result, there may be additional noise and vibration between gears. To address these problems, we analyzed the warm shrink fitting process according to process parameters; the fitting interference between the outer diameter of the shaft and the inner diameter of the gear, the inner diameter of the gear, addendum and dedendum of the gear, the heating temperature. In this study, a closed form equation for predicting the amount of deformation of addendum and dedendum in the R-direction was proposed. And the FEA method to analyze the cooling process was proposed for thermal-structural-thermal coupled field analysis of the warm shrink fitting process (heating-fitting-cooling process).

Performance of a Multitone CDMA System with Interference Canceller in a Multipath Fading Channel

  • Park, Seung-Keum;Kang, Byeong-Gwon;Chung, Hee-Chang
    • The Journal of the Acoustical Society of Korea
    • /
    • 제17권3E호
    • /
    • pp.58-66
    • /
    • 1998
  • In this paper, we analyze the effects of interference canceller on the performance of multitone DS/CDMA system proposed by Vandendorpe[5]. There are various kinds of interference canceller suggested by different researchers including parallel and successive cancellers and we adopt a canceller used by Yoon et al.[9] which is a kind of parallel canceller. We consider three kinds of interferences, that is, multipath interference(MPI), interchannel interference(ICI) and multiple access interference(MAI). The ICI is the interference between multitones. The equations for variances. are derived for the inteferences and thermal noise used for signal to noise ratio calculation. We also consider RAKE reception over multipath channel which is modeled as lowpass equivalent linear filter and three stage interference canceller used for performance improvement. We show the performance results for number of canceller stage, diversity order and number of users and draw some conclusions that interference canceller is effective in multitone DS/CDMA system and the performance is further improved with the higher order of diversity and larger number of PN chips.

  • PDF

파이프 순환수의 수치해석 모사를 통한 수직 밀폐형 지중열교환기 단면의 열전달 효율 평가 (Numerical Evaluation of Heat Transfer un Ground Heat Exchanger Considering Flow through U-loop)

  • 길후정;이강자;이철호;최항석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.583-587
    • /
    • 2009
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of the thickness of HDPE pipe and grout thermal properties, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

Evaluation of Co-Frequency Interference with IMT System Caused by Mobile-Satellite Service System

  • Park, Jong-Min;Park, Dong-Chul
    • Journal of electromagnetic engineering and science
    • /
    • 제9권3호
    • /
    • pp.141-145
    • /
    • 2009
  • Interference scenarios involving and a methodology for a terrestrial international mobile telecommunication(IMT) system and mobile-satellite service(MSS) system in a co-channel environment are established. Taking into account a practical deployment situation for both systems, a computational simulation of interference in terms of the ratio of interference power to thermal noise(I/N) is performed in order to evaluate the co-frequency interference with the IMT system caused by the MSS system. The methodology and results could be used for planning an IMT deployment without an unacceptable interference impact caused by the MSS system.

수치해석을 통한 수직 밀폐형 지중열 교환기의 열전달 거동 연구 (Thermal Behavior of Vertical Ground Heat Exchanger by Numerical Simulation)

  • 길후정;이철호;김주영;최항석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1638-1646
    • /
    • 2008
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 2-D finite element analysis, ANSYS, was employed to evaluate the temperature distribution on the borehole cross section involving HDPE pipe/grout/soil formation to compare the sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system which is equipped with a thermally insulating latice in order to reduce thermal interference between the inflow and outflow pipes. In addition, a 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of grout's thermal properties, rate of circulation pump, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

초고속기용 열박음 로터 제작을 위한 로터의 치수에 따른 가열온도의 해석적 예측 (Analytical Prediction of Heating Temperature to Manufacture Rotor with Shrink Fit for Ultra High Speed Motor According to Change Dimension of Rotor)

  • 홍도관;우병철;정연호;구대현;안찬우
    • 대한기계학회논문집A
    • /
    • 제33권9호
    • /
    • pp.963-968
    • /
    • 2009
  • This paper deals with shrink fit analysis of rotor by 2D cross-section, 2D axis-symmetry, and 3D FEM model. And this paper presents 2nd order approximation function of thermal expansion displacement by design variables (shape dimension, heating temperature, sleeve length, interference etc.), table of orthogonal array and RSM(response surface methodology). The possibility of the rotor with shrink fit is evaluated by thermal expansion displacement. If thermal expansion displacement is larger than interference, shrink fit enable to make the rotor. 2D axis-symmetry model and 3D model are more reasonable than 2D cross-section model, because stress and strain is different along length of shaft.

Improvement of Applebaum Array Interference Cancellation in Smart Antenna System by Using Covariance Matrix Adjustment

  • Tanakorn Sukontapong;Chuwong Phogcharoenpanich;Phaisan Ngamjanyaporn;Monai Krairiksh
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.727-730
    • /
    • 2002
  • This paper proposes the interference cancellation improvement in smart antenna system by using Applebaum array covariance matrix adjustment. This technique adds the specific adjustable multipliers with both desired signal covariance matrix and interference signal covariance matrices in order to overcome some disadvantages and improve the interference cancellation efficiency of Applebaum array. It is based on the desired and undesired signal power or desired signal-to-interference-plus-thermal noise ratio (SINR). As the result from demonstration, the proposed technique can improve and increase the interference cancellation efficiency in smart antenna better than the conventional technique.

  • PDF