• 제목/요약/키워드: Thermal impact

검색결과 793건 처리시간 0.028초

Thermal Impact Characteristics by Forest Fire on Porcelain Insulators for Transmission Lines

  • Lee, Won-Kyo;Choi, In-Hyuk;Choi, Jong-Kee;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권4호
    • /
    • pp.143-146
    • /
    • 2008
  • In this study the thermal impact characteristics by forest fire are extensively investigated using temperature controlled ovens. The test conditions for thermal impact damage are simulated according to the characteristics of natural forest fire. The test pieces are suspension porcelain insulators made by KRI in 2005 for transmission lines. In the thermal impact cycle tests with $300\;^{\circ}C$ thermal impact gradient (-70 to $230\;^{\circ}C$), cycling in 10 minute periods, no critical failures occurred in the test samples even with long cycle times. But in tests with thermal impact gradient from room temperature to $200-600\;^{\circ}C$, cycling in 10 to 30 minute periods, there were critical failures of the porcelain insulators according to the thermal impact gradient and quenching method. In the case of thermal impact by forest fire, it was found of that duration time is more important than the cycling time, and the initiation temperature of porcelain insulator failures is about $300\;^{\circ}C$, in the case of water quenching, many cracks and fracture of the porcelain occurred. It was found that the thermal impact failure is closely related to the displacement in the cement by thermal stress as confirmed by simulation. It was estimated that the initiation displacement by the thermal impact of $300\;^{\circ}C$ is about 0.1 %. Above 1% displacement, it is expected that the most porcelain insulators would fail.

Influence of laminated orientation on the mechanical and thermal characteristics of carbon-fiber reinforced plastics

  • Shin, Hee-Jae;Kwac, Lee-Ku;Lee, Min-Sang;Kim, Hong-Gun
    • Carbon letters
    • /
    • 제16권4호
    • /
    • pp.241-246
    • /
    • 2015
  • Rapid industrial development in recent times has increased the demand for light-weight materials with high strength and structural integrity. In this context, carbon fiber-reinforced plastic (CFRP) composite materials are being extensively used. However, laminated CFRPs develop faults during impact because CFRPs are composed of mixed carbon fiber and epoxy. Moreover, their fracturing behavior is very complicated and difficult to interpret. In this paper, the effect of the direction of lamination in CFRP on the absorbed impact energy and impact strength were evaluated, including symmetric ply (0°/0°, −15°/+15°, −30°/+30°, −45°/+45°, and −90°/+90°) and asymmetric ply (0°/15°, 0°/30°, 0°/45°, and 0°/90°), through drop-weight impact tests. Further, the thermal properties of the specimens were measured using an infrared camera. Correlations between the absorbed impact energy, impact strength, and thermal properties as determined by the drop-weight impact tests were analyzed. These analyses revealed that the absorbed impact energy of the specimens with asymmetric laminated angles was greater than that of the specimens with symmetric laminated angles. In addition, the asymmetry ply absorbed more impact energy than the symmetric ply. Finally, the absorbed impact energy was inversely proportional to the thermal characteristics of the specimens.

환경영향평가와 사후환경조사의 비교에 관한 연구 - 태안화력발전소 사례분석 - (The Study on the Improvement of Environmental Assessment Method through Analysis of Environmental Investigation Results of Taean Thermal Power Plant)

  • 전상기;이성철
    • 환경영향평가
    • /
    • 제9권1호
    • /
    • pp.61-74
    • /
    • 2000
  • This study compares the results of environmental impact assessment with the results of post-environmental investigation, using the case of Taean thermal power plant construction. The atmospheric and water qualities were not greatly changed before and after the construction of the power plant. However, the site of the highest concentration predicted by the atmospheric quality modeling in environmental impact assessment was different from that after operation of 4 power plants. There was also a difference in the diffusion range of thermal discharge water between the measured result(1km) and the predicted value(1.5km) with the model. Thus, environmental impact evaluation should be based on long-term (more than a year) environmental monitoring data. For the modeling of atmospheric quality and numerical thermal discharge water diffusion, appropriate models for each plant should be selected and the numerical modeling should be accompanied by computer simulation, wind tunnel test, etc. Moreover, environmental evaluation should focus more on the degree of impact on surroundings than the prediction of changes in surroundings caused by operation of plants.

  • PDF

복합 단열 매트 보강 폴리우레탄 폼의 열적 성능 및 내충격성 평가 (Thermal Performance and Impact Resistance Evaluations of Composite Insulation Mat Reinforced Polyurethane Foam)

  • 황병관;배진호;이제명
    • Composites Research
    • /
    • 제32권5호
    • /
    • pp.290-295
    • /
    • 2019
  • 본 연구에서는 액화 천연 가스 운반선 단열 시스템에 적용되는 폴리우레탄 폼(Polyurethane foam, PUF)의 열적 성능 및 내충격성을 향상시키기 위한 목적으로, PUF에 복합 단열 매트를 보강하였다. 복합 단열 매트는 극저온 환경에서 운용이 가능한 케블라, 에어로겔, 그리고 크라이오겔 매트를 선정하였다. 열적 성능은 $20^{\circ}C$의 상온에서 열전도율을 측정하였으며, 내충격성은 $20^{\circ}C$의 상온 및 $-163^{\circ}C$의 극저온에서 30 J의 충격에너지로 낙하 충격 시험을 수행하여 측정하였다. 측정된 열전도율은 유효 열전도율 이론 값을 통해 보강되지 않은 PUF와 비교하였으며, 내충격성은 접촉력, 접촉 시간, 그리고 흡수에너지를 평가하였다. 실험 결과 크라이오겔 복합 매트 보강 시 가장 우수한 열적 성능을 나타났으며, 내충격성은 에어로겔 복합 매트 보강 시 가장 우수하게 나타났다.

Numerical study on the impact response of SC walls under elevated temperatures

  • Lin Wang;Weiyi Zhao;Caiwei Liu;Qinghong Pang
    • Steel and Composite Structures
    • /
    • 제46권3호
    • /
    • pp.345-352
    • /
    • 2023
  • A thermal-mechanical coupling finite element model of the steel-plate concrete composite (SC) wall is established, taking into account the strain rate effect and variation in mechanical and thermal properties under different temperatures. Verifications of the model against previous fire test and impact test results are carried out. The impact response of the SC wall under elevated temperatures is further investigated. The influences of the fire exposure time on the impact force and displacement histories are discussed. The results show that as the fire exposure time increases, the deflection increases and the impact resistance decreases. A formula is proposed to calculate the reduction of the allowable impact energy considering the fire exposure time.

Impact of standard construction specification on thermal comfort in UK dwellings

  • Amoako-Attah, Joseph;B-Jahromi, Ali
    • Advances in environmental research
    • /
    • 제3권3호
    • /
    • pp.253-281
    • /
    • 2014
  • The quest for enhanced thermal comfort for dwellings encompasses the holistic utilization of improved building fabric, impact of weather variation and amongst passive cooling design consideration the provision of appropriate ventilation and shading strategy. Whilst thermal comfort is prime to dwellings considerations, limited research has been done in this area with the attention focused mostly on non-dwellings. This paper examines the current and future thermal comfort implications of four different standard construction specifications which show a progressive increase in thermal mass and airtightness and is underpinned by the newly developed CIBSE adaptive thermal comfort method for assessing the risk of overheating in naturally ventilated dwellings. Interactive investigation on the impact of building fabric variation, natural ventilation scenarios, external shading and varying occupants' characteristics to analyse dwellings thermal comfort based on non-heating season of current and future weather patterns of London and Birmingham is conducted. The overheating analysis focus on the whole building and individual zones. The findings from the thermal analysis simulation are illustrated graphically coupled with statistical analysis of data collected from the simulation. The results indicate that, judicious integrated approach of improved design options could substantially reduce the operating temperatures in dwellings and enhance thermal comfort.

폴리우레탄 콘크리트의 열전도율과 바닥충격음에 관한 연구 (A Study on the Thermal Conductivity and Floor Impact Sound of Polyurethane Concrete)

  • 강재홍;조영국;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.676-681
    • /
    • 1997
  • The purpose of this study is to evaluate the thermal Conductivity and Foolr Impact Sound of Polyurethane Concretes. The Polyurethane Concretes are prepared with various resin content, Fine and Coarse aggregates content, and its thickness, and tested for the Thermal Conductivity and Impact Sound. From the test results. the sound insulation grade of polyurethane concretes by the floor impact sound test on high frequency band is L-60, and its effect is considerable Polyurethane concretes have high degree of solidity compared with other heat shield materials, and its thermal conductivity is 0.05kcal/$mh^{\cire}C$. And it is suitable for sound proof floor materials.

  • PDF

열응력을 받은 하이브리드 섬유보강 시멘트 복합체의 내충격성능 평가 (Evaluation of Impact Resistance of Hybrid Fiber Reinforced Cementitious Composites Subjected to Thermal Stress)

  • 한승현;김규용;이예찬;유하민;박준영;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.145-146
    • /
    • 2023
  • In this study, the effect of hybrid fiber reinforcement on the residual strength and impact resistance of high-strength cementitious composites exposed to high temperatures was investigated. A cementitious composites was manufactured in which 0.15 vol% of polypropylene fiber (PP) and 1.0 vol% of smooth steel fiber (SSF) were double-mixed, and a residual strength test was conducted while thermal stress was applied by heating test, and then a high-velocity impact test was performed. In the case of general cementitious composites, the rear surface is damaged due to explosion and low tensile strength during high temperature or impact, while hybrid fiber reinforced cementitious composites can repeatedly absorb and distribute stress until multiple fibers are damaged to suppress the propagation of impact and resistance to explosion. Therefore, this study analyzed the residual strength of cementitious composites exposed to high temperatures depending on whether hybrid fibers were mixed or not, and collected research data on fracture behavior through high-speed impact tests to evaluate impact resistance and mechanical properties.

  • PDF

초등학교 교실에서 적용한 환경주의력 평가기법 개발에 관한 연구 (Study on Development of Environmental Attention Assessment Applied in the Elementary Classroom)

  • 정지원;이희관
    • 한국대기환경학회지
    • /
    • 제32권6호
    • /
    • pp.624-632
    • /
    • 2016
  • Attention plays vital role either students academic performance in classroom or work performance of workers. This study was accomplished among elementary school students of elementary school classroom for two years. Three experiment cases were designed based on the Predicted Mean Vote (PMV) indexes. Thermal environment and PMV were directly monitored; Thermal Sensation Vote (TSV) and Comfort Sensation Vote (CSV) were analyzed based on survey data; and attention was analyzed for different comfort level using FAIR program. PMV, TSV and CSV were varied with the change in thermal environment and there was not noticeable gender influence on impact. The good correlation between thermal environment, PMV, TSV and CSV confirmed the impact of thermal environment on indoor comfort. There were different impacts on attention with comfort conditions. Academic attention of low attention group i.e. weak students, can be improved by providing the comfort environment. Thermal environment influences the comfort and the comfort influences the attention, it is possible to assess the impact of thermal environment on attention in further.

Deformation Analysis of Impact Damaged Composite Tube Using Thermal Shearography

  • Kim, Koung-Suk;Chang, Ho-Seob;Jang, Su-Ok;Lee, Seung-Seok;Jang, Wan-Sik;Jung, Hyun-Chul
    • 비파괴검사학회지
    • /
    • 제28권3호
    • /
    • pp.302-308
    • /
    • 2008
  • Composite materials are widely used as structural materials for aerospace engineering because of its excellent mechanical properties such as light weight, high stiffness, and low thermal expansion. In driving, impact damage is one of the common but dangerous damages, caused by internal failure of the laminas interface which is not detected by in the surface. Many techniques to detect defects or delaminate between laminates have been reported. Shearography is a kind of laser speckle pattern interferometry with the advantages of non-destructive, non-contact, high resolution and displacement slope measurement. In this paper, the shearography is used to evaluate non-destructively impact damaged surface of the composite material and a measuring method using shearography for the thermal deformation of a impact damaged composite material is discussed. The basic principles of the technique are also described briefly.