• Title/Summary/Keyword: Thermal exposure

Search Result 513, Processing Time 0.028 seconds

Numerical study on the impact response of SC walls under elevated temperatures

  • Lin Wang;Weiyi Zhao;Caiwei Liu;Qinghong Pang
    • Steel and Composite Structures
    • /
    • v.46 no.3
    • /
    • pp.345-352
    • /
    • 2023
  • A thermal-mechanical coupling finite element model of the steel-plate concrete composite (SC) wall is established, taking into account the strain rate effect and variation in mechanical and thermal properties under different temperatures. Verifications of the model against previous fire test and impact test results are carried out. The impact response of the SC wall under elevated temperatures is further investigated. The influences of the fire exposure time on the impact force and displacement histories are discussed. The results show that as the fire exposure time increases, the deflection increases and the impact resistance decreases. A formula is proposed to calculate the reduction of the allowable impact energy considering the fire exposure time.

Effects of thermal aging on mechanical properties of laminated lead and natural rubber bearing

  • Kim, Dookie;Oh, Ju;Do, Jeongyun;Park, Jinyoung
    • Earthquakes and Structures
    • /
    • v.6 no.2
    • /
    • pp.127-140
    • /
    • 2014
  • Laminated rubber bearing is very popular base isolation of earthquake engineering pertaining to the passive structural vibration control technologies. Rubber used in fabricating NRB and LRB can be easily attacked by various environmental factors such as oxygen, heat, light, dynamic strain, and organic liquids. Among these factors, this study carried out thermal aging test to investigate the effect of thermal aging on the mechanical properties of laminated rubber bearings in accelerated exposure condition of $70^{\circ}C$ temperature for 168 hours. The compressive-shear test was carried out to identify the variation of compressive and shear properties of the rubber bearings before and after thermal aging. In contrast to tensile strength and elongation tests, the hardness of rubber materials showed the increasing tendency dependent on exposure temperature and period. Based on the test results, the property changes of rubber bearing mainly aged by heat are quantitatively presented.

A Study on the Silicon surface and near-surface contamination by $CHF_3$/$C_2$$F_6$ RIE and its removal with thermal treatment and $O_2$ plasma exposure ($CHF_3$/$C_2$$F_6$ 반응성이온 건식식각에 의한 실리콘 표면의 오염 및 제거에 관한 연구)

  • 권광호;박형호;이수민;곽병화;김보우;권오준;성영권
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.1
    • /
    • pp.31-43
    • /
    • 1993
  • Thermal behavior and $O_{2}$ plasma effects on residue and penetrated impurities formed by reactive ion etching (RIE) in CHF$_{3}$/C$_{2}$F$_{6}$ have been investigated using X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectrometry (SIMS) techniques. Decomposition of polymer residue film begins between 200-300.deg. C, and above 400.deg. C carbon compound as graphite mainly forms by in-situ resistive heating. It reveals that thermal decomposition of residue can be completed by rapid thermal anneal above 800.deg. C under nitrogen atmosphere and out-diffusion of penetrated impurities is observed. The residue layer has been removed with $O_{2}$ plasma exposure of etched silicon and its chemical bonding states have been changed into F-O, C-O etc.. And $O_{2}$ plasma exposure results in the decrease of penetrated impurities.

  • PDF

Effect of Non-thermal Dielectric Barrier Discharge Plasma by Air Volume against Mycobacterium Tuberculosis (비열 유전체장벽방전 플라즈마 발생기의 풍량에 따른 결핵균 성장억제 효능)

  • Son, Eun-Soon;Kim, Yonghee;Paik, Namwon;Lee, Ilyong;Kim, Eunhwa;Park, Hae-Ryoung;Lee, Jongseok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.414-419
    • /
    • 2019
  • Objectives: The objective of this study was to evaluate the inhibitory effect of non-thermal dielectric barrier discharge (DBD) plasma by air volume against Mycobacterium tuberculosis (MTB). Methods: Plasma generators (TB-300, Shinyoung Airtec, Seongnam-si, Korea) were operated in a 2A type biosafety cabinet. The plasma generator was set to a wind flow rate of 14 ($80m^3/h$), 18 ($110m^3/h$), and 22 ($150m^3/h$), and exposure times were set to 0 hours, 3 hours, 6 hours, 9 hours, and 24 hours. Results: The inhibitory effects of plasma at air volume 14 with prolonged exposure time of three hours was 20%, 64% at six hours, 82.3% at nine hours, and 100% after 24 hours exposure. With air volume of 18, the inhibitory effects upon plasma exposure were 36% for three hours, and 100% from 24 hours. Greater air volume resulted in greater inhibition of tuberculosis bacterial growth. In particular, the maximum inhibitory effect (100%) was shown in air volume of 22 ($150m^3/h$) after three hours of plasma exposure. Conclusions: The results showed the correlating inhibitory effects of plasma on the growth of MTB in combination with increasing plasma exposure time and air volume.

Effect of Combined Environmental Factors on Degradation Behavior of Carbon Fiber/Epoxy Composites (복합적인 환경인자의 영향에 따른 탄소섬유/에폭시 복합재의 열화 특성)

  • Hwang, Young-Eun;Lee, Gil-Hyung;Yoon, Sung-Ho
    • Composites Research
    • /
    • v.22 no.5
    • /
    • pp.37-42
    • /
    • 2009
  • Thermal analysis properties and chemical structure of carbon fiber/epoxy composites under environmental exposure were examined using an accelerated aging tester which can simulate real weather conditions such as temperature, moisture and ultraviolet. The composite specimens were exposed to combined environmental factors up to 3000 hours. Thermal analysis properties and chemical structure of the composites were evaluated with various exposure times through Modulated DSC and FTIR. According to the results of Modulated DSC, the glass transition temperature increased as exposure time increased due to the formation of network structures in the composites. Also endotherm peaks of enthalpy relaxation related to physical aging that can affect the properties of the composites were observed as exposure time increased. From the results of FTIR, it was found that the location of the peaks was little affected by exposure time, but the intensity of the peaks slightly decreased as exposure time increased due to the curing reaction in the epoxy group.

Mechanical Property Behaviors of Polyethylene Pipe due to Thermal-Degradation (열화시간에 따른 폴리에틸렌 파이프의 기계적 물성 거동)

  • Weon, Jong-Il;Choi, Kil-Yeong
    • Polymer(Korea)
    • /
    • v.33 no.5
    • /
    • pp.446-451
    • /
    • 2009
  • Reliability evaluations of linear low density polyethylene (LLDPE) pipe with respect of thermal exposure time have been investigated in accordance with RS M 0042, which is a reliability standard for polymer pipe. As the thermal exposure time is prolonged, a progressive increase, until 250 days, in tensile strength and a slight increase in hardness are observed, while a proportional decrease in elongation at break is showed. These results can be explained by the increase of crystallinity, followed by the increase of crosslinking density, chain scission and the decrease in chain mobility, due to thermal oxidation as the exposure time increases. Long term hydrostatic pressure test result implies the existence of transition point from ductile to brittle fracture. Oxidation induction time (OIT) test is employed to monitor the thermo-oxidative degradation of LLDPE pipe. This result shows that after the exposure time is 250 days, the depletion of antioxidants added in LLDPE pipe occurs. An empirical equation as function of exposure time, under $100^{\circ}C$ thermal-degradation condition, is proposed to assess the remaining amount of antioxidants owing to thermo-oxidative degradation. Fourier transform infrared spectroscopy results show the increase of carbonyl (-C=O) and hydroxyl (O-H) function groups on the surface of thermally exposed LLDPE pipe. This result suggests that the hydrocarbon groups locally undergo the oxidation on the LLDPE surface due to thermal-degradation.

A STUDY FOR THERMAL CONDUCTIVITY OF IRRADIATED CAVITY (와동내에 조사된 열의 전도양상에 관한 연구)

  • Baik, Byeong-Ju;Kim, Jae-Gon;Hur, Sun;Lee, Du-Cheol;Yun, Hyun-Du
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.583-597
    • /
    • 1998
  • The purpose of this study was to evaluate temperature change occurred in enamel, dentin and pulp due to the heat from cavity prepration with laser. We made three models had different cavity depth: cavity depth of model A was 3.52mm, model B was 2.32mm, model C was 1.16mm. We irradiated cavity base with thermal capacity of $30J,100J,300J/cm^2s$ during few seconds and studied the change of temperature in tooth during 10 seconds, and estimated change of thermal capacity by different irradiated site and exposure time. At $300J/cm^2$ irradiation for 2 seconds, the temperature of irradiated surface was elevated fast according to irradiated thermal energy during 1 second. In proportion to continuous exposure time, temperature elevated slowly. The surface temperature was $1370^{\circ}C$. After discontinue of thermal irradiation, the heat of irradiated surface was diffused in dentin and pulp and the greatest temperature was made. The greatest temperature was disappeared within 10 seconds The greatest temperature of the inner part of model brought about very severe change by different depth. Temperature in pulp was raised by the greater irradiated energy density and exposure time.

  • PDF

Anti Corrosive Performance of Al and Zn Coatings Deposited by Plasma Arc Thermal Spray Process in Artificial Ocean Water (인공해양환경에서 플라즈마 아크 용사 공법이 적용된 Al 및 Zn 코팅의 부식 방지 성능 평가)

  • Adnin, Raihana Jannat;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.52-53
    • /
    • 2020
  • The thermal spray coating process is being used to protect the metals and alloys from wear, abrasion, fatigue, tribology, and corrosion failure. Therefore, in the present study, Al and Zn was deposited by plasma arc thermal spray process onto the steel substrate and their performance was assessed. The bond adhesion result shows that Al coating has higher value attributed to compact, dense, and less porous compared to Zn coating which contain defects/pores and uneven morphology assessed by scanning electron microscopy (SEM). Electrochemical results show that the Al coating exhibited higher impedance value compared to Zn in artificial ocean water solution at prolonged exposure periods. However, both coatings show the increment in polarization resistance with exposure periods which reveal that porosity of coatings is filled by the corrosion products.

  • PDF

Estimating MOE of Thermal Degraded Wood by Stress Wave Method (Stress wave법에 의한 열적 열화된 목재의 휨탄성계수 예측)

  • Lee, Jun-Jae;Kim, Jeong-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.9-15
    • /
    • 1998
  • The strength and stiffness of structures would be weakened by thermal degradation of wood members which are exposed to a variety of heat including a fire. For this reason, thermal degraded wood members can't pertinently support the load. However, it is easy to repair or rehabilitate wood structures. So, the degraded wood members which can't support the load can be replaced with new members. For the sake of this advantage, there is a need for nondestructive evaluation(NDE) technique, which is very effective to assess wood members in service. In this paper, it was considered whether the stress wave method is adequate to estimate static bending MOE of thermal degraded wood. As the result, the relationship between static bending MOE and MOEsw in elevated temperature was found out significant. Therefore, the application of stress wave method for estimating static bending MOE of thermal degraded zzwood would be possible. However, it is thought that further research for the effects of exposure temperature, time, and thermal degradation on the relationship between static bending MOEb and MOEsw would be needed.

  • PDF

Partial Discharge Diagnosis of Thermal Degradated PVC Cable (열열화된 PVC 케이블의 부분방전 진단)

  • Song, Ki-Tae;Lee, Sung-Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.3
    • /
    • pp.208-214
    • /
    • 2011
  • In this thesis, the partial discharge according to applied voltage and variations of cross-sectional area and length of the conductor related to general condition for using cable was measured in order to study degradation diagnosis for 2-Core cable of the PVC insulator used in industrial fields for other safety installations. Also the thermal degradation conditions under various installation circumstances of cables were studied by assuming degradation conditions with each different degradation rate (50%, 67%, 100%) such as variation in degradated temperature, thermal exposure time, normal state, partially degradated state and overall degradated state for thermal degradation diagnosis. The quantity of electric discharge (V-Q) according to applied voltage was measured for measurement of inception voltage and extinction voltage. The quantity of electric discharge and the number of electric discharge (Q-N) were measured with applied voltage kept constantly. In addition, pictures were taken using SEM (scanning electron microscope) to compare the surface of external insulator to degradated state of internal insulator according to thermal degradation temperature and also compare the surface of external insulator to degradated surface state of internal insulator according exposure time of cables to thermal stress.