• 제목/요약/키워드: Thermal evaporator

검색결과 282건 처리시간 0.024초

증기 이젝터 위치에 따른 다중효용증발시스템의 설계 및 성능분석 (Design and Evaluation of Multiple Effect Evaporator Systems According to the Steam Ejector Position)

  • 김득원;최상민
    • 설비공학논문집
    • /
    • 제28권11호
    • /
    • pp.434-443
    • /
    • 2016
  • The evaporation of water from an aqueous solution is widely used in the food, desalination, pulp, and chemical industries. Usually, a large amount of energy is consumed in the evaporation process to boil off water due to atmospheric pressure. As a way of improving the energy efficiency of the evaporation process, the combination of multiple effect evaporation and thermal vapor recompression has been proposed and has become a successful technique. In this study, 4 multiple-effect falling film type evaporators for sugar solution are designed and the energy efficiency of the system is analyzed in response to the selection of the steam ejector position. Energy efficiency is increased and vapor is more compressed in the steam ejector as the Thermal Vapor Recompression (TVR) is arranged in the rear part of the evaporator system. A simplified 0-dimensional evaporator model is developed using non-linear equations derived from mass balances, energy balances, and heat transfer equations. Steam economy is calculated to compare the evaporation performance of the 4 proposed evaporators. The entrainment ratio, compression ratio, and expansion ratio are computed to check the ejector performance.

자동차용 $CO_2$ 에어컨 시스템 열교환기 성능 특성에 관한 실험적 연구 (Experimental Studies on the Performance Characteristics of Heat Exchangers of $CO_2$ Air Conditioning System for Vehicle)

  • 김성철;이동혁;원종필
    • 한국자동차공학회논문집
    • /
    • 제17권1호
    • /
    • pp.146-153
    • /
    • 2009
  • The performance characteristics of heat exchangers which consist of a gas cooler, an evaporator and an internal heat exchanger have been investigated at various operating conditions of $CO_2$ air conditioning system by experiments. The heat exchangers were designed for use in the vehicle $CO_2$ air conditioning system, when considering the characteristics of heat transfer and high pressure as $CO_2$ refrigerant. This paper studied the performance of heat exchangers at various compressor speeds and expansion valve openings, and quantified the heat transfer rates and pressure drops. Heat transfer rates at the gas cooler and the evaporator were 6.9 kW and 5.2 kW, respectively, when the compressor speed was 4000 rpm and refrigerant vapor quality at the evaporator outlet was 0.98. Therefore, this paper carried out that the heat exchangers were analyzed to achieve superior performance for the vehicle transcritical $CO_2$ cycle.

중온 태양열 응용을 위해 수평 단차를 갖는 열사이펀의 열적 성능 (Thermal Performance of a Thermosiphon with a Step-Change Elevation for Medium-temperature Solar Thermal Applications)

  • 이세권;정의국;부준홍
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.251-254
    • /
    • 2009
  • Thermal performance of a thermosiphon for medium-temperature solar thermal application was investigated. The working fluid was Dowtherm A and the container was made of STS 316L. The thermosiphon had a outer diameter of 12.7 mm and a total length of 2 m, where the evaporator and the condenser had the same length of 0.3 m and the adiabatic section was 1.4 m. Both the evaporator and the condenser were aligned horizontal with an elevation difference of 0.18 m to utilize the gravitational force for the working-fluid return. The optimum fill charge ratio of the working fluid was investigated to obtain the maximum heat transport with the lowest thermal resistance. The maximun input thermal load was 500 W and thermal resistance was $0.60^{\circ}C/W$.

  • PDF

An Analytical Model for Predicting the Effective Thermal Conductivity of Woven Wire Wick Structure

  • Lee, Jin-Sung;Kim, Chul-Ju
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권2호
    • /
    • pp.72-78
    • /
    • 2002
  • Woven wire wick is a very effective structure because of its easiness to insert inside of pipe for a miniature heat pipe. The present study was conducted to predict the porosity and the effective thermal conductivity of liquid-saturated woven wire wick. The porosity and the effective thermal conductivity of the evaporator region indicate different values from those of the condenser region due to the existence of non-flow region. The minimum value of the effective thermal conductivity indicates on condition of the $\theta$=$45^{Wcirc}$ and the values of the effective thermal conductivity increases symmetrically centering around the minimum value. The values of the effective thermal conductivity in the evaporator region at the angle of $45^{Wcirc}$ indicate about 60~80% higher than those in the condenser region for various combinations of copper, and stainless with water and ethanol.

원판증발기를 가진 회전형 히트파이프에서 액막두께가 전열에 미치는 영향 (The Effect of Film Thicknesses on Heat Transfer in a Rotating Heat Pipe with the Disc Evaporator)

  • 권순석;장영석;유병욱
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1572-1581
    • /
    • 1994
  • Heat transfer characteristics in a rotating heat pipe with evaporator of the rotating disc and the condenser of the screwed groove is investigated by numerical method for various dimensionless film thicknesses, Re, C_{p}{\Delta}T/h_{fg}$, rotational speed and working fluids. The temperature difference between evaporator wall and vapor increases a little, but the temperature difference between condenser wall and vapor decreases rapidly as Re increases. As the dimensionless film thickness decreases, the temperature difference of evaporator and condenser decreases. As the rotational speed increases, the temperature difference between evaporator wall and vapor increases but the temperature difference between condenser wall and vapor decreases. The Nusselt number can be shown as a function of dimensionless film thickness and Re, that is $Nu=0.963\cdot(\delta^{-1}(\omega/\vpsilon)^{-1/2}{\cdot}Re^{0.5025})$.

A STUDY ON HEAT TRANSFER THROUGH THE FIN-WICK STRUCTURE MOUNTED IN THE EVAPORATOR FOR A PLATE LOOP HEAT PIPE SYSTEM

  • ;성병호;최지훈;유정현;서민관
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2137-2143
    • /
    • 2008
  • This paper investigates the plate loop heat pipe system with an evaporator mounted with fin-wick structure to dissipate effectively the heat generated by the electronic components. The heat transfer formulation is modeled and predicted through thermal resistance analysis of the fin-wick structure in the evaporator. The experimental approach measures the thermal resistances and the operating characteristics. These results gathered in this investigation have been used to the objective of the information to improve the LHP system design so as to apply as the future cooling devices of the electronic components.

  • PDF

플레이트 휜 코일형 증발기의 착상에 관한 기초 실험 (Basic Experiment on Frost of Plate Fin Coil Evaporator)

  • 백승문;김창영;한인근;김재돌;윤정인
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 추계 학술발표회 논문집
    • /
    • pp.211-216
    • /
    • 1999
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. In this report, a prediction taking into account the change of the fin efficiency due to the growth of the frost layer.

  • PDF

Performance Analysis of Water-Water Heat Pump System of 100 kW Scale for Cooling Agricultural Facilities

  • Kang, Youn Ku;Ryou, Young Sun;Jang, Jae Kyung;Kim, Young Hwa;Kim, Jong Goo;Kang, Geum Chun
    • Journal of Biosystems Engineering
    • /
    • 제39권1호
    • /
    • pp.34-38
    • /
    • 2014
  • Purpose: In this study, the performance of cooling system with the water-water heat pump system of 100kW scale made for cooling agricultural facilities, especially for horticultural facilities, was analyzed. It was intended to suggest performance criteria and performance improvement for the effective cooling system. Methods: The measuring instruments consisted of two flow meters, a power meter and thermocouples. An ultrasonic and a magnetic flow meter measured the flow rate of the water, which was equivalent to heat transfer fluid. The power meter measured electric power in kW consumed by the heat pump system. T-type thermocouples measured the temperature of each part of the heat pump system. All of measuring instruments were connected to the recorder to store all the data. Results: When the water temperature supplied into the evaporator of the heat pump system was over $20^{\circ}C$, the cooling Coefficient Of Performance(COP) of the system was higher than 3.0. As the water temperature supplied into the evaporator, gradually, lowered, the cooling COP, also, decreased, linearly. Especially, when the water temperature supplied into the evaporator was lower than $15^{\circ}C$, the cooling COP was lower below 2.5. Conclusions: In order to maintain the cooling COP higher than 3.0, we suggest that the water temperature supplied into evaporator from the thermal storage tank should be maintained above $20^{\circ}C$. Also, stratification in the thermal storage tank should be formed well and the circulating pumps and the pipe lines should be arranged in order for the relative low-temperature water to be stored in the lower part of the thermal storage tank.

R123 열원 적용 증발식 담수 시스템 특성 연구 (Characteristics of Solar Desalination System Using Refrigerant-123 As a Heating Source)

  • 윤상국;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.33-38
    • /
    • 2010
  • The evaporative desalination system using solar thermal energy would be the efficient and attractive method to get fresh water from brine due to low carbon dioxide generation. In this research the solar desalination system as a heating source of refrigerant R123 in the evaporator was considered. The circulation of refrigerant in the evaporator can reduce the energy consumption of the system, because of using the latent heat of the refrigerant 123 instead of the sensible heat of present hot water. The system was comprised of the single-stage fresh water production unit on the capacity of 1ton/day with shell and tube type evaporator, heaters instead of solar collector to supply the proper heat to refrigerant, and refrigerant and brine circulation systems. Various operating flowrate and temperature ranges were varied in the experiments to get the optimum design data. The results showed that the optimum flow rate of brine feed rate to evaporator was 1.2Liter/min, and the yield of fresh water was increased as higher temperature of feed brine. It was confirmed that the circulation flowrate of heating source of refrigerant was decrease of one fifth of the present warm water system, and very efficient system for solar desalination.

SUDS증발기를 사용한 2중열원 열펌프의 성능해석 (Performance analysis of dual source heat pump system with single unit dual source evaporator)

  • 우정선;이세균;이재효;박효순
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.391-400
    • /
    • 1999
  • The efficiency and capacity of an air source heat pump system decrease as the ambient temperature drops. One strategy of avoiding the decrease of the efficiency and capacity in air source heat pump system is to switch to another thermal energy source. Water can be a good candidate for the heat source. This paper presents the results of the performance analysis of heat pump system with a single unit dual source(SUDS) evaporator The heat exchanger combines two separated evaporators into a single evaporator and the object of the SUDS evaporator is to recover energy from dual heat sources, i.e. air and water. Simulation program is developed for the dual source heat pump system with a SUDS evaporator and experimental data are obtained and compared with the simulation results. Differences in heating capacity and COP are 7% and 8% respectively. Simulation results are in good agreement with the test results. Therefore, the developed program is effectively used for the design and performance prediction of the dual source heat pump system with a SUDS evaporator.

  • PDF