Large Scale Treatment of Perfluorocompounds Using a Thermal Plasma Scrubber

  • Han, Sung-Han;Park, Hyun-Woo;Kim, Tae-Hee;Park, Dong-Wha
    • 청정기술
    • /
    • 제17권3호
    • /
    • pp.250-258
    • /
    • 2011
  • Thermal plasma has been presented for the decomposition of perfluorocompounds (PFCs) which are extensively used in the semiconductor manufacturing and display industry. We developed pilot-scale equipment to investigate the large scale treatment of PFCs and called it a "thermal plasma scrubber". PFCs such as $CF_4$, $C_2F_6$, $SF_6$, and $NF_3$ used in experiments were diluted with $N_2$. There were two different types of experiment setup related to the water spray direction inside the thermal plasma scrubber. The first type was that the water was sprayed directly into the gas outlet located at the exit of the reaction section. The second type was that the water was sprayed on the wall of the quenching section. More effective decomposition took place when the water was sprayed on the quenching section wall. For $C_2F_6$, $SF_6$, and $NF_3$ the maximum destruction and removal efficiency was nearly 100%, and for $CF_4$ was up to 93%.

Consideration for the Highest Temperature Point Movement of the Dongrae Thermal Water in the Pusan Area. (Poster)

  • Kim Tong-Kwon;Lee Jin-Soo;Lee Seung-Gu;Song Yoon-Ho;Kim Tack-Hyun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2005년도 INTERNATIONAL SYMPOSIUM ON SOIL & GROUNDWATER ENVIRONMENT
    • /
    • pp.158-159
    • /
    • 2005
  • This study showed that the highest temperature point of the Dongrae thermal spring in Pusan was moved to the north direction of the Dongrae fault as times goes by. The Br concentration(1.5mg/L) in Dongrae thermal waters indicated the influence of 2% seawater mixing. If the simple mixing without hydrochemical reaction occurs between seawater and thermal water, the concentration of Mg will be about 20mg/L. But the low concentration(0.1 mg/L) of Mg, contrary to high concentration(10 mg/L) of surrounding groundwater not affected by thermal water, suggested the thermal water, seawater and rock interactions. The calculation of saturation index(SI) by using the geochemical code of EQ3NR showed that the Mg in thermal groundwater, which was introduced by seawater, was removed by the precipitation of Antigorite (SI: log Q/K =71.753, $Mg_{48}Si_{24}O_{85}(OH)_{62}$) and Tremolite (SI: 8.463, $Ca_2Mg_5Si_8O_{22}(OH)_2$), Talc (SI: 6.409, $Mg_3Si_4O_{10}(OH)_2$), Dolomite (SI: 2.014, $CaMg(CO_3)_2$), Chrysotile (SI: 3.698, $Mg_3Si_2O_5(OH)_4$) in the crack of fault zone. The highest temperature point in the study area will move to north direction and stop in the Jangjun area without the input of seawater.

  • PDF

인공위성 탑재품 수준 열진공 시험에 대한 열해석 모델의 개발과 환경시험 결과를 이용한 검증 (Development and Verification of Thermal Analysis Model for Thermal Vacuum Test of Satellite Components)

  • 김상호;서현석;유재호;한은수;김태경;김형동;허환일
    • 한국항공우주학회지
    • /
    • 제38권8호
    • /
    • pp.842-847
    • /
    • 2010
  • 본 연구는 인공위성 탑재품 열진공 시험시 적용된 열환경 조건, 탑재품 시험용 열진공 챔버의 형상, 위성체 내부의 열환경들을 고려하여 열진공 시험 과정을 모사하는 수치해석모델을 설계하여 열해석을 수행하였다. 피시험체인 탑재품과 열진공 챔버 구성요소의 시간에 따른 온도 변화를 보여주는 과도적(Transient) 해석 결과를 구할 수 있다. 열해석에 의한 성능향상 설계를 반영하여 업그레이드한 열진공 챔버를 이용한 탑재품 환경시험을 수행하였으며, 시험 결과와 열해석 결과에 대한 비교/검증을 수행하였다.

외부 환경적 요인에 의한 파이프랙 구조물의 열적 거동 (Thermal Behavior of a Pipe-Rack Structure Subjected to Environmental Factors)

  • 이종한;이종재;김성연
    • 한국건설순환자원학회논문집
    • /
    • 제3권2호
    • /
    • pp.165-170
    • /
    • 2015
  • 파이프랙 구조물은 고온 고압의 파이프를 지지하며 플랜트의 운전 안전성을 좌우하는 매우 중요 구조물이다. 따라서, 파이프랙 구조물의 손상은 산업 전반에 부정적인 파급효과를 가져옴과 동시에 인명 및 재산상의 막대한 피해까지 가져오게 된다. 특히, 파이프랙 구조물은 외부환경에 노출되어 있어, 구조물의 적절한 설계 및 유지관리를 위하여 환경적 영향에 의한 거동 특성을 평가할 필요가 있다. 따라서, 가장 널리 설계되어지는 하나의 파이프랙 구조물을 대상 구조물로 선정하여 열-구조 연성해석을 실시하여 파이프랙 구조물의 온도분포와 열응력을 평가하였다. 외부 환경적 요인으로는 국내의 여수지역과 중동의 사우디 지역을 고려하여 파이프의 운전조건과 함께 외부환경 영향인자에 대한 고려 필요성을 검증하였다.

열-알칼리성 전처리에 따른 폴리하이드록시부티레이트의 혐기성 소화 개선 효과 조사 (Improving Anaerobic Digestion of Polyhydroxybutyrate by Thermal-Alkaline Pretreatment)

  • ;이준엽
    • 한국환경과학회지
    • /
    • 제31권7호
    • /
    • pp.609-616
    • /
    • 2022
  • In this study, the effect of different reaction times for thermal-alkaline pretreatment on the solubilization and biogasification of polyhydroxybutyrate (PHB) were evaluated. Thermal-alkaline pretreatment tests were performed at 73 ℃ and pH 13 at 0-120 h reaction times. The mesophilic anaerobic batch tests were performed with untreated and pretreated PHB samples. The increase in the pretreatment reaction time results in a 52.8-98.8% increase of the abiotic solubilization efficiency of the PHB samples. The reaction time required to achieve solubilization efficiencies of 50%, 90%, and 95% were 10.5, 52.0, and 89.6 h, respectively. The biogasification of the untreated PHB samples achieved a specific methane production rate of 3.6 mL CH4/g VSS/d and require 101.3 d for complete biogasification. The thermal-alkaline pretreatment significantly improved specific methane production rate (10.2-16.0 time increase), lag time (shortened by 76-81%), and time for complete biogasification (shortened by 21-83%) for the biogasification of the PHB samples when compared to those of the untreated PHB samples. The improvement was higher as the reaction time of the thermal-alkaline pretreatment increased. The findings of this study could be used as a valuable reference for the optimization of the biogasification process in the treatment of PHB wastes.

Experimental and finite element parametric investigations of the thermal behavior of CBGB

  • Numan, Hesham A.;Taysi, Nildim;Ozakca, Mustafa
    • Steel and Composite Structures
    • /
    • 제20권4호
    • /
    • pp.813-832
    • /
    • 2016
  • This research deals with the behavior of Composite Box Girder Bridges (CBGBs) subjected to environmental effects such as solar radiation, atmospheric temperature, and wind speed. It is based on temperature and thermal stress results, which were recorded hourly from a full-scale experimental CBGB segment and Finite Element (FE) thermal analysis. The Hemi-cube method was adopted to achieve the accuracy in temperature distributions and variations in a composition system during the daily environmental variations. Analytical findings were compared with the experimental measurements, and a good agreement was found. On the other hand, parametric investigations are carried out to investigate the effect of the cross-section geometry and orientation of the longitudinal axis of CBGB on the thermal response and stress distributions. Based upon individual parametric investigations, some remarks related to the thermal loading parameters were submitted. Additionally, some observations about the CBGB configurations were identified, which must be taken into account in the design process. Finally, this research indicates that the design temperature distribution with a uniform differential between the concrete slab and the steel girder is inappropriate for describing the thermal impacts in design objective.

2013년 부산지역 폭염사례일의 열쾌적성 평가 (Evaluation of Thermal Environments during the Heat Waves of Summer 2013 in Busan Metropolitan Area)

  • 김영준;김현수;김유근;김진국;김연매
    • 한국환경과학회지
    • /
    • 제23권11호
    • /
    • pp.1929-1941
    • /
    • 2014
  • Now a days, frequency of abnormally high temperatures like heat wave by global warming and climate change is increasing constantly and the number of patient with heat related illness are jumping rapidly. In this study, we chose the case day for the heat wave in Busan area(Busan and Yangsan), 2013 which it was the most hottest year during 21th century. And then, we analysed the weather condition using automatic synoptic observing system(ASOS) data. Also, four indices, heat index(HI), wet bulb globe temperature(WBGT), Man-ENvironment heat EXchange model(MENEX)'s results like Physiological subjective temperature(PST), Physiological strain(PhS), were calculated to evaluate the thermal comfort and stress quantitatively. However, thermal comfort was different as the each station and thermal comfort index during same time. Busan's thermal indices (HI: hot, WBGT: sweltering, PST: very hot, PhS: very hot) indicated relatively higher than Yansan's (HI: very hot, WBGT: sweltering, PST: very hot, PhS: sweltering). It shows that Busan near coast is relatively more comfortable than Yangsan located in inland.

Subjective Responses to Thermal Stress for the Outdoor Performance of Smart Clothes

  • Kwon, JuYoun;Parsons, Ken
    • 대한인간공학회지
    • /
    • 제36권3호
    • /
    • pp.169-181
    • /
    • 2017
  • Objective: The aim of this study was to explore the influence of outdoor weather conditions on subjective responses during physical activity. Background: The largest difference between indoor and outdoor conditions is the existence of the sun. The heat load from the sun has an influence on the heat gain of the human body and the intense degree of solar radiation affected thermal comfort. Method: Thirty eight people were exposed to a range of climatic conditions in the UK. Weather in England does not have extremely hot and cold temperature, and the current study was conducted under warm (summer and autumn) and cool (spring and summer) climates. Measurements of the climate included air temperature, radiant temperature (including solar load), humidity and wind around the subjects. Subjective responses were taken and physiological measurements included internal body temperature, heart rate and sweat loss. Results: This study was conducted under four kinds of environmental conditions and the environmental measurement was performed in September, December, March, and June. The values for sensation, comfort, preference, and pleasantness about four conditions were from 'neutral' to 'warm', from 'not uncomfortable' to 'slightly comfortable', from 'slightly cooler' to 'slightly warmer', and from 'neither pleasant nor unpleasant' and 'slightly unpleasant', respectively. All subjective responses showed differences depending on air temperature and wind speed, and had correlations with air temperature and wind speed (p<0.05). However, subjective responses showed no differences depending on the radiant temperature. The combined effects of environmental parameters were showed on some subjective responses. The combined effects of air temperature and radiant temperature on thermal sensation and pleasantness were significant. The combined effects of metabolic rate with air temperature, wind speed and solar radiation respectively have influences on some subjective responses. In the case of the relationships among subjective responses, thermal sensation had significant correlations with all subjective responses. The largest relationship was shown between preference and thermal sensation but acceptance showed the lowest relationship with the other subjective responses. Conclusion: The ranges of air temperature, radiant temperature, wind speed and solar radiation were $6.7^{\circ}C$ to $24.7^{\circ}C$, $17.9^{\circ}C$ to $56.6^{\circ}C$, $0.84ms^{-1}$ to $2.4ms^{-1}$, and $123Wm^{-2}$ to $876Wm^{-2}$ respectively. Each of air temperature and wind speed had significant relationships with subjective responses. The combined effects of environmental parameters on subjective responses were shown. Each radiant temperature and solar radiation did not show any relationships with subjective responses but the combinations of each radiant temperature and solar radiation with other environmental parameters had influences on subjective responses. The combinations of metabolic rate with air temperature, wind speed and solar radiation respectively have influences on subjective responses although metabolic rate alone hardly made influences on them. There were also significant relationships among subjective responses, and pleasantness generally showed relatively high relationships with comfort, preference, acceptance and satisfaction. Application: Subjective responses might be utilized to predict thermal stress of human and the application products reflecting human subjective responses might apply to the different fields such as fashion technology, wearable devices, and environmental design considering human's response etc.

Removal of Heavy Metals(Pb, Cr) Using Waste Eggshell

  • Park, Heung-Jai;Bong, Sang-Hun;Jeong, Seong-Ug
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.386-393
    • /
    • 2005
  • The calcination characteristic of waste eggshell were examined by thermal gravimetric analysis (TGA), qualitative and quantitative analysis by X-ray fluorescence, and microstructural analysis by scanning electronic microscopy(SEM). The calcined sample was lager grain and pore size.

  • PDF

대류 난방시 실내열환경에 관한 연구 -상하온도차에 대한 온열쾌적감- (The Study on Indoor Thermal Environment during Convection Heating - Thermal Comfort Sensation for Vertical Temperature Differences -)

  • 김동규;금종수
    • 한국환경과학회지
    • /
    • 제14권2호
    • /
    • pp.215-220
    • /
    • 2005
  • Thermal neutrality is not enough to achieve thermal comfort. The temperature level can be the optimal, and still people may complain. This situation is often explained by the problem of local discomfort. Local discomfort can be caused by radiant asymmetry, local air velocities, too warm and too cold floor temperature and vertical temperature difference. This temperature difference may generate thermal discomfort due to different thermal sensation in different body parts. Therefore, thermal comfort can not be correctly evaluated without considering these differences. This study investigates thermal discomfort sensations of different body parts and its effect on overall thermal sensation and comfort in air-heating room. Experimental results of evaluating thermal discomfort at different body parts in an air-heating room showed that thermal sensation on the shoulder was significantly related to the overall thermal sensation and discomfort. Although it is known that cool-head, warm-foot condition is good for comfort living, cool temperature around the head generated discomfort.