Spread Patterns of Thermal Effluent Discharged From Young-Kwang Nuclear Power Plant Using Remote Sensing Data

  • Han J. G.;Yeon Y. K.;Chi K. H.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.331-335
    • /
    • 2004
  • This study is focused to analyze the movement of thermal effluent dischargeed from nuclear power plant by season, ebb and flow, and before and after foundation of tide embankment using thermal infrared band image of 28 scenes observed from Landsat from 1987 to 2004, which is the early stage of operation of young-kwang nuclear power plant. In diffusion of thermal effluent discharge by seasons, spring and summer is spreading further than autumn and winter. It is considered to distribute widely mixed with thermal effluent discharge and hot water, which is distributed naturally along the seaside. It is known the fact that tidal currents control the direction of diffusion of thermal effluent discharge by the change of ebb and flow. Namely, it is distributed widely on the Southwest direction along the seaside by tidal currents when ebb and, it is moved widely on the Northeast direction along the seaside by tidal current when flood. However, in the early stage of flood current, the mainstream of thermal effluent discharge is spread on Southwest direction and, the direction is changed on North­east way when the latter period of flood current. Similarly, in the early stage of ebb current, the mainstream of thermal effluent discharge is spread on Northeast direction and, the direction is changed on Southwest direction when the latter period of ebb current. As the result of comparing to the diffusion pattern of thermal effluent discharge before and after the foundation of seawall, discharged thermal effluent from the drain of plant by the foundation of dike is shown as curved circle pattern on Northeast to West direction from the ending portion of the seawall.

  • PDF

Spatial Variation in Macrobenthic Communities Affected by the Thermal Discharge Volumes of a Nuclear Power Plant on the East Coast of Korea (원자력 발전소의 온배수 배출량 변화에 따른 대형저서동물 군집의 공간 변화)

  • Yu, Ok Hwan;Lee, Hyung-Gon;Lee, Jae-Hac;Kim, Kyung-Tae;Myung, Cheol-Soo;Moon, Hyung Tae;Byun, Ju Young
    • Ocean and Polar Research
    • /
    • v.35 no.4
    • /
    • pp.299-312
    • /
    • 2013
  • This study analyzed the species composition and density of a macrobenthic community according to variations in the thermal discharge volumes of a nuclear power plant before, during, and after the shutdown of the nuclear power plant during two periods. In this study, 369 macrobenthic fauna species were collected, and their mean density was 1,712 ind. $m^{-2}$. The number of species and diversity of macrobenthic fauna decreased with distance from the thermal discharge area, regardless of whether the nuclear plant shutdown or not. Many macrobenthic taxa appeared near the thermal discharge area, but polychaetes species were more prominent in outer areas than at the discharge area. The density of macrobenthic fauna decreased with distance from the thermal discharge area during a plant shutdown in the fall of 2011, but increased, except at two sites, near the discharge area in the winter of 2012. Cluster analysis indicated that the spatial distribution of the macrobenthic community changed in areas near the nuclear power plant after a shutdown period; that is, the station group I, in areas near the nuclear power plant, became narrower after the shutdown, but it recovered to previously occupied areas after the nuclear power plant began operating again. Opportunistic species, such as the polychaetes Lumbrineris longifolia (= Scoletoma longifolia) and Mediomastus californiensis, which were present in high densities near thermal discharge areas, decreased after the shutdown but recovered after the plant re-opened. The number of species and diversity of the macrofauna and the density of dominant species showed a significant correlation with temperature, except in winter periods. The results of this study revealed that changes in the amount of thermal discharge before and after the shutdown of a nuclear power plant could exert an influence on the structure of macrobenthic community within the thermal discharge areas depending on the season.

Spectral analysis for thermal discharge of Hadong Power Plant (하동화력 발전소 온배수에 대한 Spectrum 분석)

  • Park, Il-Heum;Lee, Geun-Hyo
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.435-440
    • /
    • 2006
  • In order to understand changes of water temperature for thermal discharge of Hadong power plant in Gwangyang and Jinju Bay, it was analyzed for temperature data of representative season by MEM(Maximum entropy method) that is one of the spectral analysises. And due to understand effect of thermal discharge at each point, analyzed spectral data showed reactive energy rate of reference point by calculating energy from 24 time period to height frequency zone. As a result of spectral analysis, it showed that there were 9 points which are largely effected, 7 points which will be estimated, 6 points which is difficult to estimate, 14 points which rarely effected by thermal discharge.

  • PDF

Community Structure of Macrobenthos around the Thermal Discharge Area of the Uljin Nuclear Power Plant in the East Sea, Korea (동해 울진 원전 온배수배출구 주변 해역에서의 대형저서동물 군집구조)

  • Kwon, Soon Hyun;Yu, Ok Hwan;Lee, Hyung-Gon
    • Ocean and Polar Research
    • /
    • v.39 no.2
    • /
    • pp.125-148
    • /
    • 2017
  • This study analyzed the community structure of macrobenthic organisms in the subtidal area suffering under the influence of thermal discharge from the Uljin nuclear power plant during 2012-2013 and reviewed the temporal change in the faunal composition of the macrobenthic community using data from previous studies since the start of the plant operation in 1989. A total of 319 species were collected in 2012-2013, with a mean density of $3,330ind./m^2$ and a mean biomass of $131.96g/m^2$. These results were similar to those obtained in 2006-2007. The dominant species were not different from each other before and after the power plant operations began, but the faunal density near the power plant drainage port was significantly higher compared to those densities obtained from other stations. Spiophanes bombyx and Polydora sp., which is known as a pollution indicator species, was dominant only in the drainage port area. The study area consisted of two subregions with different macrobenthic communities depending on the water depth, which was similar to the results of the 2006-2007 survey. The macrobenthic community structures before and after the operation of the power plant in the coastal area were not changed, but there were seasonal differences in the long-term macrobenthic community structure which were strongly related to the thermal discharge from the power plant.

A Study on the NOx Removal Rate by Arrangement of Discharge Electrode in Pulsed Corona Discharge Reactor (펄스 코로나 반응기에서 방전극의 배열에 따른 탈질율 연구)

  • Choi, Min;Park, So-Jin;Wi, Young-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.3
    • /
    • pp.315-323
    • /
    • 2003
  • The goal of this study if the optimization of discharge electrode for pulsed corona discharge reactor located in thermal power plant. For this purpose, we have performed experiments of NO$_{x}$ removal rate by exchange of discharge electrode diameter and arrangement of discharge electrode in the non -thermal plasma reaction facility using a ethylene as additive. If the diameter and numbers of discharge electrode were larger, the NO$_{x}$ removal rate was higher. From these results, if we optimized the shape and installed numbers of discharge electrode at the pilot plant, we could increase the NO$_{x}$ removal rate with less amount of additive than current amount.mount.

A Standard Guide to Physical Oceanographic Survey of the Effect of Thermal Discharge from a Nuclear Power Plant (원자력발전소 온배수 영향 해양물리분야 조사의 표준지침)

  • Lee, Jae-Hak;Ro, Young-Jae;Cho, Yang-Ki
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.1
    • /
    • pp.43-49
    • /
    • 2007
  • The methods of physical oceanographic surveys to examine the effect of thermal discharge from nuclear power plants in Korea have been reviewed and a standard guide to the survey is proposed. It is desirable that in situ observation and numerical thermal diffusion modeling are conducted simultaneously to describe the variation in temperature distribution affected by thermal discharge from a power plant because any observation or numerical modeling alone has limits to do so quantitatively. It is suggested that the field observation must be based on the concept of heat budget modeling considering all artificial and natural heat sources/sinks around the power plant. Any results from numerical modeling must reach to a certain statistical significance level to use for a standard temperature distribution. In addition, the development of standard numerical codes is proposed to improve the problems shown in the past numerical circulation and diffusion modelling.

Design and Implementation of Fluid Flow Generation System by using Water Captures (물받이를 이용한 유수발전장치의 설계 및 구현)

  • Son, Young-Dae;Jung, Hyun-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.413-421
    • /
    • 2012
  • This paper proposes the design and implementation of fluid flow generation system by using polypropylene(PP) water capture, which harvests electric energy from the kinetic energy of tidal current or water flow and drives the desired load, and applies it to the discharge drain of Hadong thermal power plant. This experimental system is composed of water captures, driving wheel, gear trains, 10[kW] synchronous generator, and three phase rectifying circuit which drives lamp load for test. The proposed water capturing system which is composed of water captures, rope and driving wheel, rotates as caterpillar according to water flow. This system is very easy to manufacture and more economical than another type of tidal current turbines such as conventional propeller and helical type. Also, we estimated the available fluid flow energy that can be extracted from the cooling water in discharge drain based on drain's cross-sectional area. Therefore, this paper confirms the validity of proposed fluid flow generation system with water captures and the possibility of its application for renewable energy generation in discharge drain of thermal power plant, from the obtained performance characteristic of this energy conversion system.

A Study on Analysis of Reserves and Available Capacity of Unutilized Energy in Rural Community (농어촌지역 미활용에너지의 부존량과 이용 가능량 분석)

  • Park, Mi-Lan;Ryoo, Yeon-Su;Kim, Jin-Wook;Lee, Yong-Uk;Bae, Sung-Don;Chae, Kap-Byung
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.19-25
    • /
    • 2014
  • Alternative sources of energy take a higher interest in order to reduce the greenhouse gas under the Climate Change Convention, fossil fuel consumption, and lower social anxiety about nuclear power such as crisis involving the Fukushima plant, problem of obsolete equipment. The energy consumption of agriculture, forestry and fisheries in South Korea is 3,082,000toe by 2011, reliance on electrical energy(35%) and oil(57.2%) is very high with 92.2%. In this study, we examined reserves and available capacity of temperature difference energy for thermal discharge from plant, treated sewage, river water, dam, and agricultural reservoir in rural community. Reserves of unutilized energy are 455,735Tcal/yr in rural community, these accounts for 78% of total reserves 582,385Tcal/y. Thermal discharge from plant has the most reserves of unutilized energy in rural community, it is estimated that it has the reserves of 277,410Tcal/y. Available capacity of unutilized energy in rural community is total 134,147Tcal/y, thermal discharge from plant available for heating is the most 128,035Tcal/y, and it shows in the order of treated sewage 4,318Tcal/y, river water 1,653Tcal/y, and reservoir 141Tcal/y. Elevating temperature area of green house by 2012 is 21,208ha. The amount of energy required for heating the greenhouse a year is dbout 11,365Tcal/y with 8.5% of the total available capacity of unutilized energy.

Technical Development of Flue Gas Control at Commercial Plant Using the Non-thermal Plasma Process (저온 플라즈마 공정을 이용한 상용설비의 배연가스 처리 기술개발)

  • Yoo, J.S.;Paek, M.S.;Kim, T.H.;Kim, J.I.;Kim, Y.S.;Choi, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.939-944
    • /
    • 2001
  • For the application of simultaneous $DeSO_{2}\;&\;DeNO_{x}$ equipment using non-thermal plasma process to the industrial and power plants, the many types of plasma device and process were studied. The e-beam and pulsed plasma corona discharge process are outstanding for the study to apply commercial large-scale plant from among these. In this paper, non-thermal plasma of technical trends and the characteristics of system developed by Doosan heavy industries & construction Co., Ltd. are explained. We have researched pulsed plasma corona discharge process since 1994. At the basis of reasonable results for the pilot plant, we constructed the demonstration plant at a domestic coal-fired power plant in 1999, as the previous step for commercial use. In near future, enough information about designs and costs of commercial-size system will be obtained.

  • PDF

Thermal Index for the Assessment of the Impacted Area by the Thermal Discharge from Nuclear Power Plant in Korea (원자력 발전소 온배수 피해역 산정을 위한 영향지수 시안)

  • Ro, Young-Jae
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.1
    • /
    • pp.35-42
    • /
    • 2007
  • Thermal discharges from the nuclear power plants into neighboring Korean coastal waters have raised serious disputable arguments from the two parties of local fishermen and scientists involved since late 1970's. To meet the social demands and provide scientific and reasonable solutions, new set of standards have been established which will guide through measuring and processing the various variables and parameters in environmental and fishery impact assessment procedures for the thermal discharge from the nuclear power plants. These are made possible for the first time by the combined efforts by Korean Oceanography Society and Fishery Society. In this paper, Thermal Disharge Impact Index(TI) is proposed by the probability of the local temperatures exceeding critically to local fishery multiplied by the weighted sum of diverse environmental and ecological factors. The TI is essentially conceived to overcome the long-exising bad practices based on the particular excess temperature such as 1. The proposed TI based on the guideline principle proposed by the UNEP(2002) is expected to be practical, economic and self-adaptive. To prove the usefulness of the TI, it is highly recommended to conduct prototype experiments and exercises in a particular nuclear power plant site in the near future.