• Title/Summary/Keyword: Thermal damage

Search Result 918, Processing Time 0.029 seconds

The dependence of NiSi for CMOS Technology on Surface Damage (CMOS 소자를 위한 NiSi의 surface damage 의존성)

  • Ji, Hee-Hwan;Bae, Mi-Suk;Lee, Hun-Jin;Oh, Soon-Young;Yun, Jang-Gn;Park, Sung-Hyung;Wang, Jin-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.167-170
    • /
    • 2002
  • The influence of Si surface damage on Ni-silicide with TiN Capping layer and the effect of $H_2$ anneal are characterized. Si surface is intentionally damaged using Ar Sputtering. The sheet resistance of NiSi formed on damaged silicon increased rapidly as Ar sputtering time increased. However, the thermal stability of Ni-Si on the damage silicon was more stable than that on at undamaged Si, which means that damaged region retards the formation of NiSi. It was shown that $H_2$ anneal and TiN capping is highly effective in reducing NiSi sheet resistance.

  • PDF

Characteristics of $Si^+$ self implant Induced Damage and Its Annealing Behavior ($Si^+$ 이온주입된 Si 기판의 결함형성 및 회복에 관한 연구)

  • ;;;;;;Hiroshi Kuwano
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.91-99
    • /
    • 1994
  • Damage induced by Si ion implantation and its annealing behavior during rapid thermal annealing were investigated by cross-sectional TEM (transmission electron microscopy) and RB ( Rutherford backscattering) spectrum. 150keV and 50keV Si ions were implanted in Si (100) at room temperature with doses of 2${\times}10^{15}cm^{-2}$. And 100keV Si ions were implanted in Si with doses from 1${\times}10^{14}cm^{-2}$. A variety of damage structures were generated by Si ion implantation such as continuous amorphous layer extending to the surface buried amorphous layer and damage clusters. Damage clusters are annealed out at the lower annealing temperature of 550 $^{\circ}C$. However, event at the temperature of 110$0^{\circ}C$ end of range loops remain in the original lower amorphous/crystal interface in the case of continuous and buried amorphous layer formation. Extended defects in the shape of zipper dislocations are also observed at the middle of the recrystallized region in the buried amorphous layer.

  • PDF

A damage model predicting moderate temperature and size effects on concrete in compression

  • Hassine, Wiem Ben;Loukil, Marwa;Limam, Oualid
    • Computers and Concrete
    • /
    • v.23 no.5
    • /
    • pp.321-327
    • /
    • 2019
  • Experimental isotherm compressive tests show that concrete behaviour is dependent on temperature. The aim of such tests is to reproduce how concrete will behave under environmental changes within a moderate range of temperature. In this paper, a novel constitutive elastic damage behaviour law is proposed based on a free energy with an apparent damage depending on temperature. The proposed constitutive behaviour leads to classical theory of thermo-elasticity at small strains. Fixed elastic mechanical characteristics and fixed evolution law of damage independent of temperature and the material volume element size are considered. This approach is applied to compressive tests. The model predicts compressive strength and secant modulus of elasticity decrease as temperature increases. A power scaling law is assumed for specific entropy as function of the specimen size which leads to a volume size effect on the stress-strain compressive behaviour. The proposed model reproduces theoretical and experimental results from literature for tempertaures ranging between $20^{\circ}C$ and $70^{\circ}C$. The effect of the difference in the coefficient of thermal expansion between the mortar and coarse aggregates is also considered which gives a better agreement with FIB recommendations. It is shown that this effect is of a second order in the considered moderate range of temperature.

Composite components damage tracking and dynamic structural behaviour with AI algorithm

  • Chen, Z.Y.;Peng, Sheng-Hsiang;Meng, Yahui;Wang, Ruei-Yuan;Fu, Qiuli;Chen, Timothy
    • Steel and Composite Structures
    • /
    • v.42 no.2
    • /
    • pp.151-159
    • /
    • 2022
  • This study discusses a hypothetical method for tracking the propagation damage of Carbon Reinforced Fiber Plastic (CRFP) components underneath vibration fatigue. The High Cycle Fatigue (HCF) behavior of composite materials was generally not as severe as this of admixture alloys. Each fissure initiation in metal alloys may quickly lead to the opposite. The HCF behavior of composite materials is usually an extended state of continuous degradation between resin and fibers. The increase is that any layer-to-layer contact conditions during delamination opening will cause a dynamic complex response, which may be non-linear and dependent on temperature. Usually resulted from major deformations, it could be properly surveyed by a non-contact investigation system. Here, this article discusses the scanning laser application of that vibrometer to track the propagation damage of CRFP components underneath fatigue vibration loading. Thus, the study purpose is to demonstrate that the investigation method can implement systematically a series of hypothetical means and dynamic characteristics. The application of the relaxation method based on numerical simulation in the Artificial Intelligence (AI) Evolved Bat (EB) strategy to reduce the dynamic response is proved by numerical simulation. Thermal imaging cameras are also measurement parts of the chain and provide information in qualitative about the temperature location of the evolution and hot spots of damage.

Thermal Impact Characteristics by Forest Fire on Porcelain Insulators for Transmission Lines

  • Lee, Won-Kyo;Choi, In-Hyuk;Choi, Jong-Kee;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.143-146
    • /
    • 2008
  • In this study the thermal impact characteristics by forest fire are extensively investigated using temperature controlled ovens. The test conditions for thermal impact damage are simulated according to the characteristics of natural forest fire. The test pieces are suspension porcelain insulators made by KRI in 2005 for transmission lines. In the thermal impact cycle tests with $300\;^{\circ}C$ thermal impact gradient (-70 to $230\;^{\circ}C$), cycling in 10 minute periods, no critical failures occurred in the test samples even with long cycle times. But in tests with thermal impact gradient from room temperature to $200-600\;^{\circ}C$, cycling in 10 to 30 minute periods, there were critical failures of the porcelain insulators according to the thermal impact gradient and quenching method. In the case of thermal impact by forest fire, it was found of that duration time is more important than the cycling time, and the initiation temperature of porcelain insulator failures is about $300\;^{\circ}C$, in the case of water quenching, many cracks and fracture of the porcelain occurred. It was found that the thermal impact failure is closely related to the displacement in the cement by thermal stress as confirmed by simulation. It was estimated that the initiation displacement by the thermal impact of $300\;^{\circ}C$ is about 0.1 %. Above 1% displacement, it is expected that the most porcelain insulators would fail.

Utilization of Immersion-Drying Method for Measuring Damage Depth of Fire-Damaged High-Strength Concrete (화재로 손상된 고강도 콘크리트의 손상 깊이 측정을 위한 수중침지 건조방법의 활용)

  • Kim, Jong;Lim Gun-Su;Beak, Seung-Bok;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.3
    • /
    • pp.297-308
    • /
    • 2024
  • This study presents a novel approach for evaluating fire-induced damage depth in concrete. The methodology leverages the principle that exposure to high temperatures causes internal expansion within concrete, leading to increased voids and microcracks in the damaged zones. This heightened porosity results in greater absorption rates compared to undamaged areas. By immersing fire-damaged concrete samples in water and subsequently monitoring the drying process, the depth of damage can be assessed. Differences in drying rates and color variations between damaged and undamaged areas serve as visual indicators for determining the extent of the damage. Experimental results from this water immersion method revealed damage depths of 38.7mm and 37.5mm for two different concrete mixtures. These measurements notably surpass the damage depths estimated using traditional phenolphthalein-based methods. This discrepancy suggests that utilizing the absorption rate principle, which is directly linked to the physical changes caused by thermal expansion, offers a more accurate and sensitive assessment of fire damage depth compared to methods relying solely on the presence of Portlandite for colorimetric indication.

electrical Damage of Metallized Film Capacitors (필름 Capacitor의 전기적Damage에 관한 연구)

  • ;Chathan M. Cooke
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.6
    • /
    • pp.574-581
    • /
    • 1991
  • Damage in film capacitors has been investigated, using FTIR and ESCA, aiming to elucidate the nature of electrode removal and the possibility of base films to be damaged. Also, tests were conducted to investigate the effect of a long-term thermal aging at elevated temperatures. Unsuccessful clearing or grape-clustering processes can induce a long-term degradation which involves the chemical and morphological changes. Major changes are the oxidation and the decrease in surface crystallinity possibly arising from the corona discharge. An immediate deterioration of BOPP film may occur when the air entrapped between the film layers induces an extensive autocatalytic oxidative degradation. This type of immediate damage may result in a premature failure at an early stage of qualification test. As far as the nature of electrode removal is concerned, a permanent removal of electrode materials was observed in the main erosion area.

  • PDF

Low Cycle Fatigue Behavior of 12Cr Steel for Thermal Power Plant Steam Turbine (화력발전소 증기터빈용 12Cr 강의 저주기 피로거동)

  • Kang, Myeong-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.8
    • /
    • pp.71-76
    • /
    • 2002
  • In this study low cycle fatigue (LCF) behavior of 12Cr steel at high temperature are described. Secondly, comparisons between predicted lives and experimental lives are made for the several sample life prediction models. Two minute hold period in either tension or compression reduce the number of cycles to failure by about a factor of two. Twenty minute hold periods in compression lead to shorter lives than 2 minute hold periods in compression. Experiments showed that life predictions from classical phenomenological models have limitations. More LCF experiments should be pursued to gain understanding of the physical damage mechanisms and to allow the development of physically-based models which can enhance the accuracy of the predictions of components. From a design point-of-view, life prediction has been judged acceptable for these particular loading conditions but extrapolations to thermo-mechanical fatigue loading, for example, require more sophisticated models including physical damage mechanisms.

Effect of Skin Burn on the Skin and Liver (피부화상이 피부 및 간에 미치는 영향)

  • Nam, Chul-Hyun;Seo, Hyun-Gyu;Hwang, Tae-Yeun;Choi, Hyun-Lim;Lee, Dong-Ho
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.2
    • /
    • pp.1091-1097
    • /
    • 2001
  • The main experiments was investigated the skin tissue damage changing for the skin bum having influence on the skin and the liver and also observed the radical liver weight, ALT in the serum, the fluctuating of AST for the skin bum causing to the liver damage. Anatomically the edema formation of skin after thermal injury was showed, and skin bum increased liver weight (% of body weight, p<0.05) and the activity of serum aniline aminotrasferase (p<0.05), and also histologically induced wes of epidermal layer, protein degeneration of connective tissue, local hemorrhage and degeneration of glandular epithelium in the skin tissue. Liver tissue showed the evidences of postbum damage, they were sinusoidal dilatation, cell swelling, infiltration of inflammatory cells.

  • PDF

A Study on the Analysis of Tool-wear Patterns and Mechanisms in Face Milling (정면밀링에서 공구마멸 패턴과 메커니즘 분석에 관한 연구)

  • Jang, Sung-Min;Baek, Seung-Yub
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.4
    • /
    • pp.24-29
    • /
    • 2017
  • This paper provides an experimental analysis on the breakage of the coated tool using the face-milling cutter of the machining center due to changes in the cutting speed and the feed rate. The experimental studies were conducted using STS 304 materials and the damage to the tool was analyzed according to the change in machining time. The experiments confirmed that the cutting speed and feed rate affected the tool damage and the mechanical impact and thermal shock were determined to severely damage the tool. From the production engineering point of view, it has been experimentally investigated that the increased feed rate significantly influences the material removal rate more than the increased cutting speed.