• 제목/요약/키워드: Thermal comfort(TC)

검색결과 3건 처리시간 0.015초

시스템에어컨과 환기시스템 설치 강의실에서 냉방시 열쾌적성 및 실내공기질 연구 (Study on Thermal Comfort and Indoor Air Quality in the Classroom with System Air-conditioner and Ventilation System for Cooling Loads)

  • 노광철;장재수;오명도
    • 대한기계학회논문집B
    • /
    • 제30권1호
    • /
    • pp.57-66
    • /
    • 2006
  • The experimental and the numerical study was performed on the comparison of thermal comfort(TC) and indoor air quality(IAQ) in the lecture room for cooling loads when the operating conditions are changed. PMV value and $CO_2$ concentration of the lecture room were measured and compared with the numerical results. The numerical results showed a good agreement with the experimental one and then the numerical tool was used to analyze thermal comfort and IAQ for a couple of operating conditions. As a result it was found that the increment of the discharge angle of system air-conditioner makes TC uniformity worse, but rarely affects IAQ. Also TC and IAQ were hardly affected by the variation of the discharge airflow. Finally it turned out that TC is merely affected by the increment of the ventilation airflow, but the average $CO_2$ concentration can be satisfied with Japanese IAQ standards of classrooms when the ventilation airflow is more than $800m^3/h$ in this study.

강의실에서 환기시스템과 난방시스템의 풍량에 따른 PMV와 $CO_2$ 농도 특성 비교 (Comparison of the PMV and $CO_2$ concentration Characteristic in the Lecture Room with a Different Airflow rate of the Ventilation System and Heating System for heating season)

  • 한창우;노광철;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.411-416
    • /
    • 2006
  • In this paper, we performed the experimental and numerical study on the thermal comfort(TC) and indoor air quality(IAQ) in the lecture room with a different airflow rate of the ventilation system and heating system for heating season. Through the experimental results, we found out that there was considerably difference of the PMV but there was little difference of $CO_2$ concentration with a different heating system. From a numerical results, the best operating condition was that discharge airflow rate of SAC is 29 CMM and supply airflow rate of the ventilation system is 1,200 CMH from a viewpoint of TC and IAQ.

  • PDF

쾌적한 상태에서 계절별 의복을 착용하고 있는 동안 불감증설과 온열 생리 요소들 간의 관련성 (Relationships between Insensible Perspiration and Thermo Physiological Factors during Wearing Seasonal Clothing Ensembles in Comfort)

  • 이주영;최정화;박준희
    • 한국의류학회지
    • /
    • 제31권12호
    • /
    • pp.1700-1709
    • /
    • 2007
  • 본 연구의 목적은 계절별 의복을 착용하고 쾌적한 상태를 유지하는 동안 불감체중손실과 온열 생리적 요소들간의 관련성을 살펴보는 것이다. 이를 위해 한국의 계절별 실내 환경이 인공기후실에 조성되었고 (봄/가을 환경 기온 평균 22.5, 여름 24.7, 겨울 16.8), 설문조사를 바탕으로 총 26 종의 계절별 한벌의복이 선정되었다(봄/가을 옷 8종, 여름 옷 7종, 겨울 옷 11종). 다섯 명의 젊은 여성이 피험자로 참여하였으며, 결과는 다음과 같다: 1) 불감체중손실(IL)은 봄/가을 의복을 착용한 경우 $19{\pm}5g{\cdot}m^{-2}{\cdot}hr$, 여름 옷 $21{\pm}5g{\cdot}m^{-2}{\cdot}hr$, 겨울 옷 $18{\pm}6g{\cdot}m^{-2}{\cdot}hr$으로, 겨울 환경보다 여름 환경에서 더 컸다(p<.001). 2) 호흡기를 통한 불감수분손실(IWR)은 불감체중손실과 반대의 경향을 보여 주어, 겨울옷을 입은 경우 $6{\pm}1g{\cdot}m^{-2}{\cdot}hr$, 여름 옷을 입은 경우 $5{\pm}1g{\cdot}m^{-2}{\cdot}hr$ 였다(p<.001). 3) 불감수분손실 (IW)에서 호흡기를 통한 불감수분손실이 차지하는 비중은 여름 옷을 착용한 경우 평균 28%, 겨울 의복의 경우 38%였다(p<.001). 4) 쾌적한 상태에서, 산열량 중 불감수분손실이 차지하는 비율은 봄/가을 의복을 착용한 경우 25%, 여름옷의 경우 27%, 겨울옷의 경우 23%였다. 5) 불감체중손실과 의복의 보온력 간, 그리고 불감체중손실과 피복면적 간에는 모두 약한 역상관 관계가 관찰되었다. 6) 불감체중손실은 기온, 기습, 에너지 대사, 환기량, 평균피부온도, 의복내 습도 등의 요소와 유의한 상관을 보였으나, 상관계수들은 모두 0.5 이하였다. 결론적으로, 불감체중손실과 온열 생리 요인들 간에는 약한 상관이 존재했으나, 피험자들이 온열 쾌적을 유지하는 경우 착용한 의복 종류 및 노출 기온에 상관없이 불감체중손실량은 좁은 범위를 유지했다.