• 제목/요약/키워드: Thermal chamber

검색결과 719건 처리시간 0.026초

개별환경제어(PEM)시스템의 열적 특성 및 성능개선에 관한 연구 (The Experimental Study on Thermal Characteristics of PEM(Personal Environment Module) System)

  • 조성환;장철용;태춘섭
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.439-447
    • /
    • 2000
  • The PEM(Personal Environment Module) system is an individual air conditioning system developed in order to improve thermal comfort in office buildings. In this study, thermal characteristics of a PEM system have measured experimentally and compared with UFAC(Under Floor hir Conditioning) system in the EC(Environment Chamber) constructed in KIER. Results showed that the PEM system was better than UFAC system for thermal comfort and energy conservation.

  • PDF

겨울철 실내온열환경의 쾌적범위설정에 관한 실험연구 (Establishing the Comfort Zone of Thermal Environment in Winter)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제30권2호
    • /
    • pp.81-86
    • /
    • 1992
  • The purpose of this study was to investigate the psychophysical correponding to temperature and to establish the comfort zone of thermal environment for Korean in winter. An experimental investigation was carried out in climate chamber maintaining the air temperature at 20, 22, 24, 26℃ and subjects were 128 college-age Korean(64 males and 64 females) in good health. Data were analyzed by SPSS PC+ packages. 'Neutral' on the thermal sensation ratings was most frequently indicated at 24℃ by subjects was 23.1℃ (male 24.0℃, female 22.7℃), therefore the comfort zone of thermal environment in winter was considered as 23∼24℃.

  • PDF

Using Natural Graphite Heat Spreaders to Increase CCFL LCD Operating Temperatures

  • Norley, Julian;Shives, Gary D.;Reis, Brad;Schober, John
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.273-276
    • /
    • 2007
  • A natural graphite heat spreader increased the upper operating temperature limit of a CCFL backlit LCD television. A 0-80W heat source was used to simulate additional electronics. Without the heat spreader, internal circuitry shut-down at ${\sim}30;$ no shut-down occurred above 80W with a heat spreader. Additionally, brightness, temperature uniformity, and operating ranges were improved, verified by environmental chamber performance testing at various ambient conditions.

  • PDF

가솔린엔진의 냉각계 유로 변경을 통한 금속면 온도 및 전열에 관한 실험적 연구 (An Experimental Study on the Metal Surface Temperature and Heat Transfer by Improving Gasoline Engine Cooling Passages)

  • 이재헌;류택용;신승용;최재권
    • 한국자동차공학회논문집
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2002
  • Metal surface temperatures around the combustion chamber in a gasoline engine directly affect thermal durability and performance of the engine. Metal surface temperatures are influenced by many cooling factors such as drilled water passage, deflector, combustion chamber wall thickness, pillar, and coolant flow pattern. The object of this study is to learn how the coolant passages and coolant flow pattern in an engine influence to the engine metal surface temperature at engine full load and speed. From the test result, it is suggested a plan to reinforce the engine stiffness and to reduce the thermal stress simultaneously. Also, approaches are introduced to reduce the thermal load on the engine by adjusting the discharging direction from the water pump and by optimizing the water transfer holes in the cylinder head gasket. These methods and the optimized engine cooling system, which were suggested in this paper, were adapted for an engine in progress to eliminate the exhaust valve seat wear.

멤스기술을 이용한 가상밸브가 있는 새로운 잉크젯 헤드 개발 (Development of a new thermal inkjet head with the virtual valve fabricated by MEMS technology)

  • 배기덕;백석순;신종우;임형택;신수호;오용수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1892-1897
    • /
    • 2003
  • A new thermal inkjet printer head on SOI wafer with virtual valve was proposed. It was composed of two rectangular heaters with same size. So we could call it T-jet(Twin jet). T-jet has a lot of merits. It has the advantage of being fabricated with one wafer and is easy to change the size of chamber, nozzle, restrictor and so on. However, above all, It is the best point that T-jet has a virtual valve. And it was manufactured on SOI wafer. The chamber was formed in its upper silicon whose thickness was 40um. The chamber's bottom layer was silicon dioxide of SOI wafer and two heaters were located underneath the chamber's ceiling. And the restirctor was made beside the chamber. Nozzle was molded by process of Ni plating. Ni was 30um thick. Nozzle ejection test was performed by printer head having 56 nozzles in 2 columns with 600NPI(nozzle per inch) and black ink. It measured a drop velocity of 12m/s, a drop volume of 30pl, and a maximum firing frequency of 12KHz for single nozzle ejection. Throwing out the ink drop in whole nozzles at the same time, it was observed that the uniformity of the drop velocity and volume was less than 4%.

  • PDF

추력 2톤급 축소형 칼로리미터 개발 (Development of 2-ton thrust-level sub-scale calorimeter)

  • 조원국;류철성;정용현;이광진;김승한;이수용
    • 한국항공우주학회지
    • /
    • 제33권3호
    • /
    • pp.107-113
    • /
    • 2005
  • 고성능 로켓엔진 연소기의 벽면 열유속 측정을 위하여 추력 2톤급 칼로리미터를 개발하였으며 고온에서 전열특성과 강도특성이 뛰어난 크롬동합금을 연소실 내벽 소재로 적용하였다. 전체적인 냉각성능은 경험식을 기반으로 하는 1차원 해석으로 확인하였으며 국부적인 냉각성능은 3차원 CFD 해석으로 검증하였다. 연소압 53 bar 조건에서 노즐목에서의 열유속은 43 $MW/m^{2}$ 으로 예측되었다. 연소실의 구조적인 안전성은 150 bar에서 2차원 해석과 시편에 대한 변형실험으로 확인하였다. 최종적으로 상온 150 bar에 대한 가압실험으로 안전성을 검증하였고 개발된 칼로리미터와 동일한 냉각성능을 갖는 시험용 노즐을 사용하여 예비시험을 수행하였다. 노즐목에서 측정된 열유속이 설계값에 비하여 10% 높았음에도 연소실 내벽에 열손상은 발생하지 않았다.

전자빔 용접기 진공 작업실의 구조설계 (Structural Design on the Vacuum Chamber of Electron Beam Welding System)

  • 이영신;류충현;서정;한유희
    • 한국레이저가공학회지
    • /
    • 제1권1호
    • /
    • pp.11-17
    • /
    • 1998
  • The electron beam welding system has the advantages of the high power density, narrow welding section, and small thermal distortion of a workpiece. Recently, the electron beam welding system is widely used to the airplane engineering, nuclear power plant, and automobile industry. In the present paper, the structural analyses on the vacuum chamber of the electron beam welding system are performed by the F.E.M. analysis. The stiffening characteristics on the geometric shape, stiffener height and stiffener span are investigated. The deflection of the stiffened vacuum chamber under pressure is minimized by longitudinal and transverse stiffeners which are continuous in both direction.

  • PDF

적외선 열화성 온도 측정법을 이용하여 살펴본 서브밀리미터 스케일 촉매 연소기에서의 수소-공기 예혼합 가스의 촉매 연소 특성 (An Investigation on Combustion Characteristics of Hydrogen-Air Premixture in a Sub-millimeter Scale Catalytic Combustor using Infrared Thermography)

  • 최원영;권세진
    • 한국연소학회지
    • /
    • 제10권3호
    • /
    • pp.17-24
    • /
    • 2005
  • A sub-millimeter scale catalytic combustor with a simple plate-shaped combustion chamber was fabricated. A porous ceramics support coated with platinum catalyst was placed in the chamber. The combustor has a gallium arsenide window on the top that is transparent to infrared ray. The temperature distribution in the combustion chamber was measured using infrared thermal imager while hydrogen-air premixture is steadily supplied to the combustor. The area where the catalytic reaction took place broaden for higher flow rate and lower equivalence ratio made activated area in the combustion chamber broaden. The amount of coated platinum catalyst did not affect the reaction. Stop of reaction, which is similar to flame quenching of conventional combustion, was investigated. Large content of heat generation and broad activated area are essential criteria to prevent stop of reaction that has a bad effect on the combustor performance.

  • PDF

정적챔버에서 스파크 플러그 이온프로브를 이용한 공연비와 이온신호와의 상관관계에 대한 연구 (A Study on Correlation between A/F and ion signal in a Constant-Volume Chamber Using Spark-plug Ionization Probe Itself)

  • 박종일;전광민;한재원;박철웅
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.223-229
    • /
    • 2002
  • Spark plug ionization signal could be useful in an internal combustion engine as a feedback signal for combustion diagnostics such as misfire detection, knocking detection and lambda control, but the signal has high level of cyclic fluctuation in an internal combustion engine due to residual gas, pressure, temperature, mixture composition in the spark gap. Because of this reason it is very difficult to apply ion signal to commercial engine control. In this Study, a correlation between A/F and spark plug ionization signal was studied in a constant volume chamber. Constant volume chamber with gas phase fuel(Propane) has homogeneous fuel composition , no mixture flow, same pressure and temperature on each test. The results show that mean chemi-ion signal has the highest correlation with A/F and intial pressure change has on effect on the thermal-ion signal and not on chemi-ion signal.

  • PDF