• Title/Summary/Keyword: Thermal calculation

Search Result 796, Processing Time 0.028 seconds

Validation of Computational Fluid Dynamics Calculation Using Rossendorf Coolant Mixing Model Flow Measurements in Primary Loop of Coolant in a Pressurized Water Reactor Model

  • Farkas, Istvan;Hutli, Ezddin;Farkas, Tatiana;Takacs, Antal;Guba, Attila;Toth, Ivan
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.941-951
    • /
    • 2016
  • The aim of this work is to simulate the thermohydraulic consequences of a main steam line break and to compare the obtained results with Rossendorf Coolant Mixing Model (ROCOM) 1.1 experimental results. The objective is to utilize data from steady-state mixing experiments and computational fluid dynamics (CFD) calculations to determine the flow distribution and the effect of thermal mixing phenomena in the primary loops for the improvement of normal operation conditions and structural integrity assessment of pressurized water reactors. The numerical model of ROCOM was developed using the FLUENT code. The positions of the inlet and outlet boundary conditions and the distribution of detailed velocity/turbulence parameters were determined by preliminary calculations. The temperature fields of transient calculation were averaged in time and compared with time-averaged experimental data. The perforated barrel under the core inlet homogenizes the flow, and therefore, a uniform temperature distribution is formed in the pressure vessel bottom. The calculated and measured values of lowest temperature were equal. The inlet temperature is an essential parameter for safety assessment. The calculation predicts precisely the experimental results at the core inlet central region. CFD results showed a good agreement (both qualitatively and quantitatively) with experimental results.

Thermal Decomposition of Copolymers of Butyl methacrylate and Styrene Produced in a CSTR

  • Kim, Duck-Sool;Kim, Nam-Seok;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.273-280
    • /
    • 2002
  • Thermal decomposition of the copolymer of butyl methacylate(BMA) with styrene(St) was investigated. The copolymer Was obtained at 80 $^{\circ}C$ in a continuous stirred tank reactor(CSTR) using toluene and benzoyl peroxide(BPO), as solvent and initiator, respectively. The reactor volume was 0.3 liters and residence time was 3 hours. The thermal decomposition followed the second order kinetics for BMA/St copolymer. The activation energies of thermal decompositon were in the ranges of 38 ${\sim}43$ kcal/mol for BMA with St copolymer and a good additivity rule was observed with the composition of copolymer. The thermogravimetric trace curve agreed well with the theoretical calculation.

Analysis of Thermal Recovery Characteristics for Nozzle of SF6 GCB Considering Nozzle Ablation (노즐용삭을 고려한 SF6 가스차단기 노즐의 열적회복특성 해석)

  • Lee Byeong-Yoon;Song Ki-Dong;Chong Jin-Kyo;Park Kyong-Yop
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.2
    • /
    • pp.76-82
    • /
    • 2005
  • In this paper, a method for analyzing the thermal recovery characteristics of the nozzle of gas circuit breaker was described. In order to obtain thermal recovery characteristics, the transient simulation of SF6 arc plasma within the nozzle was carried out. In particular, the nozzle ablation was taken into account by simultaneously solving the PTFE concentration equation with the governing equations such as continuity, momentum and energy equation. After that, post arc current calculation was performed with the rate of rise of recovery voltage changed. From the calculated post arc current, it was possible to suggest the thermal recovery characteristics of the nozzle of gas circuit breaker.

Design of an Aquifer Thermal Energy Storage System(II) : Thermal Analysis (지하대수층을 이용한 축열시스템의 설계(II) : 열해석)

  • Lee, K.S.;Lee, T.H.;Song, Y.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.315-324
    • /
    • 1994
  • The energy recovery efficiency(ERE) of an aquifer thermal energy storage system was calculated using curvilinear coordinate. The results of the calculation were compared with the experimental results, and agreed within 11% of the discrepancy. The variation of ERE was investigated as a function of the underground water natural velocity, the amount of the stored energy, and period of the energy recovery. The slower the natural velocity and shorter the recovery period, the higher ERE was yielded. Also it was found that increase in the amount of energy storage yields higher ERE, and carries out less influential ERE to the natural velocity. Reiterative usage of the aquifer as a thermal storage tends to gradually increase ERE. The result of this study implements that the aquifer thermal energy storage system is suitable for large cooling/heating loads, such as district cooling/heating.

  • PDF

Analysis of the stresses induced by magnetic field and cooling in the CICC type superconducting bus-line (CICC 형태의 초전도 버스 선에서 냉각 및 자기장에 의한 응력 해석)

  • Lee, Ho-Jin;Nam, Hyeon-Il;Kim, Gi-Baek;Hong, Gye-Won
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.2
    • /
    • pp.20-25
    • /
    • 2000
  • A CICC type superconducting bus-line electrically connecting a superconducting magnet to a power supply is cooled down to low temperature under the external magnetic field during operation. The thermal contraction during the cooling may be constrained by the supports which are installed to protect the bus-line from Lorenz magnetic forces. This constrained contraction causes thermal stresses in the bus-line to release thermal contraction. The minimum stress conditions in the bus-line may be optimized by controlling the supporting arrangement considering the thermal contraction and the external field. The analytical method to find optimal supports arrangement was suggested by using the beam theory, and numerical calculation using commercial code was performed to verify the suggested analytical optimization method.

  • PDF

Evaluation of Thermal Utilization of Dousing System in PHWR Nuclear Power Plant

  • Nam, S.D.;Ryu, J.I.
    • Journal of ILASS-Korea
    • /
    • v.4 no.3
    • /
    • pp.42-52
    • /
    • 1999
  • An effectiveness of thermal utilization of a dousing system in the 600 MW PHWR Nuclear Power Plant has been evaluated. The behavior and conditions of water droplet sprayed in a postulated accident conditions in containment configuration has been calculated. In this calculation, two pressure conditions with the consideration of obstruction area and containment wall effect has been established : one being the minimum containment pressure of 7 kPa(g) encountered for dousing shut off and the other being the containment design pressure 124 kPa(g). The results revealed that the effectiveness of the thermal utilization ranges from 93% to 97%. In the analysis on two cases without/with side wall effect in the containment building, the thermal utilization decreases with obstruction area from 89% to 85%, which satisfies the design criteria set for the containment pressure against the accident condition.

  • PDF

A Study on the Suggestion of Thermal Comfort Range in Radiant Floor Ondol Heating System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.2
    • /
    • pp.108-112
    • /
    • 2004
  • The purpose of this study is to investigate the characteristics of thermal comfort index and to present the thermal comfort range through regression analyses and experiment in a radiant floor heating system laboratory. The results were compared to the comfort zone of ISO-7730, and the applicability of the thermal comfort index to a radiant floor heating system was studied. On comparing the sedentary posture on the floor to sitting on the chair, the comfort zone and the neutral point of comfort index showed different values. It is considered that the influence of conduction from floor to the human is sufficient. Moreover, we could find a correlation between the thermal sensation votes of subjects, and the comfort indexes were lower than those by calculation.

A Study on the Prediction of Temperature Change during the Thermal Fatigue Test of Exhaust Manifolds (배기계 내구시험 중의 온도 변화 예측을 위한 연구)

  • 이원근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.5
    • /
    • pp.29-36
    • /
    • 2003
  • Exhaust manifolds suffer from serious temperature variation during the thermal fatigue test. The spatial distribution of temperature changes at each moment. Because transient flow can not be simulated during the long period of temperature change, the simulation can not be performed by conjugate heat transfer analysis. In this study, a new procedure for transient thermal analysis is established by decoupling fluid-solid analysis. The procedure consists of (1) transient CFD calculation (2 cycles), (2) mapping heat transfer coefficient to the inner surface of solid mesh as a boundary condition of heat conduction analysis and (3) transient heat conduction analysis in the long period (30 min). The realistic temperature change can be predicted by this procedure.

Calculation of CO2 Emission w.r.t. Instantaneous Generator Output using Input-output Coefficients of Thermal Power Plant (화력발전소 입출력 특성계수를 이용한 순시 발전출력 대비 CO2 대기배출량 계산)

  • Lee, Sang-Joong;Lim, Jeong-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.120-125
    • /
    • 2007
  • Burning the fossil fuel in the thermal power plants causes green house gas emission. Monitoring of CO2 emission of the thermal power plants is growing more important because the amount produced by them is more than 20 percent of national total emission. This paper proposes a method to calculate the amount of the CO2 emission w.r.t. generator[MW] output using the input-output coefficients of the thermal power plants. The power flow computation together with the CO2 emission calculation are demonstrated in a sample power system.

Structural Characterization and Thermal Behavior of a Novel Energetic Material: 1-Amino-1-(2,4-dinitrophenylhydrazinyl)-2,2-dinitroethylene

  • Ren, Xiaolei;Zuo, Xiangang;Xu, Kangzhen;Ren, Yinghui;Huang, Jie;Song, Jirong;Wang, Bozhou;Zhao, Fengqi
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.7
    • /
    • pp.2267-2273
    • /
    • 2011
  • A novel energetic material, 1-amino-1-(2,4-dinitrophenylhydrazinyl)-2,2-dinitroethylene (APHDNE), was synthesized by the reaction of 1,1-diamino-2,2-dinitroethylene (FOX-7) and 2,4-dinitrophenylhydrazine in N-methyl pyrrolidone (NMP) at 110 $^{\circ}C$. The theoretical investigation on APHDNE was curried out by B3LYP/6-311+$G^*$ method. The IR frequencies analysis and NMR chemical shifts were performed and compared with the experimental results. The thermal behavior of APHDNE was studied by DSC and TG/DTG methods, and can be divided into two crystal phase transition processes and three exothermic decomposition processes. The enthalpy, apparent activation energy and pre-exponential factor of the first exothermic decomposition reaction were obtained as -525.3 kJ $mol^{-1}$, 276.85 kJ $mol^{-1}$ and $10^{26.22}s^{-1}$, respectively. The critical temperature of thermal explosion of APHDNE is 237.7 $^{\circ}C$. The specific heat capacity of APHDNE was determined with micro-DSC method and theoretical calculation method, and the molar heat capacity is 363.67 J $mol^{-1}K^{-1}$ at 298.15 K. The adiabatic time-to-explosion of APHDNE was also calculated to be a certain value between 253.2-309.4 s. APHDNE has higher thermal stability than FOX-7.