• Title/Summary/Keyword: Thermal analysis characteristics

Search Result 2,348, Processing Time 0.031 seconds

Structural Characteristic Analysis of a Centerless Grinding Machine with Concrete Bed (콘크리트 베드를 이용한 무심연삭기의 구조특성 해석)

  • 김석일;성하경
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.32-36
    • /
    • 2002
  • This paper presents the structural characteristic analysis of a centerless grinding machine with concrete bed. The centerless grinding machine is composed of grinding wheel head, regulating wheel head, concrete bed, wheel dresser and so on. Especially, the concrete bed is introduced to improve the static, dynamic and thermal characteristics of the centerless grinding machine. The structural analysis model of centerless grinding machine is constructed by the finite element method, and the structural characteristics in the design stage are estimated based on the structural deformation and harmonic response under the various testing conditions related to gravity force and directional farces

  • PDF

Computational Analysis of the Heat/Moisture Characteristics and Heat Load of Underground Structures (열.수분 동시이동 모델을 이용한 지하구조물 및 주변지반의 열수분성상 예측에 관한 연구)

  • Park, Kyung-Soon;Son, Won-Tug
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.901-905
    • /
    • 2008
  • This study was conducted to clarify the heat load characteristics and heat and moisture behavior of underground structures. The authors achieved this by carrying out a numerical analysis using simple heat diffusion and simultaneous heat and moisture transfer equations based on measurement data. This paper presents the results of a numerical analysis on the heat load characteristics and heat and moisture behavior of an underground basement and its surrounding ground under a condition of internal heat generation. The authors found it difficult to predict the heat behavior and heat load of the underground basement by simple heat diffusion alone. Accurate prediction of the thermal environment and heat load requires careful consideration of the influences of moisture and precipitation

  • PDF

Far-infrared Emission Characteristics of ZrC Imbedded Heat Storage Knitted Fabrics for Emotional Garment (탄화지르코늄 함유 감성의류용 축열/발열 편물의 원적외선 방출특성)

  • Kim, Hyun-Ah
    • Science of Emotion and Sensibility
    • /
    • v.18 no.1
    • /
    • pp.49-58
    • /
    • 2015
  • This paper investigated far-infrared emission characteristics of ZrC imbedded heat storage knitted fabrics for emotional garment. For this purpose, ZrC imbedded heat storage PET was spun with high viscosity PET imbedded ZrC powder on the core part and low viscosity PET on the sheath part by conjugated spinning method. Ingredient analysis and far-infrared emission characteristics assessment of spun filament were carried out by EDS and FT-IR spectrometer. Two kinds of knitted fabrics were made using texturized ZrC imbedded PET for measuring thermal characteristics of ZrC imbedded heat storage PET. Zr peak was certified by EDS measurement and it was confirmed that content of Zr was 19.29%. Far-infrared analysis revealed that emission power at the range of wavelength, $5{\sim}20{\mu}m$ was $3.65{\times}10^2W/m^2$, and emissivity was 0.906. Heat storage analysis by KES-F7 system revealed that $Q_{max}$ of ZrC imbedded PET knitted fabric was lower than that of regular PET one and warmth keepability rate was higher than that of regular one, which means that ZrC imbedded PET knitted fabric has heat storage property. Thermal conductivity of ZrC imbedded PET knitted fabric was higher than that of regular PET one which was caused by high thermal conductivity of Zr itself. Hand property of ZrC imbedded knitted fabric was not inferior compared to regular PET knitted fabric, which preferably was found to be dependent on knit structure and surface property.

A Simulation on the Thermal and Fluid about Motorcycle Muffler (모터사이클 머플러 내부 열.유동에 관한 시뮬레이션)

  • Yi, Chung-Seub;Ji, Myoung-Kuk;Shim, Kyu-Jin;Chung, Han-Shik;Lee, Cheol-Jae;Bae, Jae-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2642-2647
    • /
    • 2007
  • This study represents numerical study on the thermal and fluid flow characteristics of exhaust gas in a motorcycle muffler. The reference engine was used 124.cc small displacement. Numerical analysis with computational fluid dynamics(CFD) was carried out to investigate the exhaust gas that flow into a motorcycle muffler. The STAR-CD S/W used to three dimensional steady state CFD analysis in a muffler. And than We got the information of static pressure it is used to structural analysis ant the first baffle plate using the commercial CAE code ANSYS workbench. Exhaust gas flow third chamber from frist chamber and running second chamber. A simulation result shows that each chamber of muffler temperature is about 460 K, 445 and 463K and pressure is about 22,000 Pa, 16,000 Pa and 10,000 Pa.

  • PDF

Injection molding analysis for LED outdoor lighting top cover of one heat sink body type structure (방열체 일체형 구조의 LED 아웃도어 등기구 상부커버에 관한 사출성형해석)

  • Lee, Kwan-Young
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.42-48
    • /
    • 2020
  • This study is on the injection molding analysis for the LED outdoor lighting top cover of one heat sink body type structure. Thermoplastic and thermosetting resins were applied to compare the thermal properties during the injection molding process. The thermoplastic resin is used in this study due to special characteristics that it is light, good strength and dose long not transmute quality even if pass long time. The thermosetting resin is applied to this study due to good in strength, lightweight and excellent etc, thermal conductivity. This study presented a preliminary analysis of fill time, weld line, air trap etc. for the injection molding process of LED lamp cover and body through simulation using Moldflow. As a result of the study, it was selected HTM-102 material because the thermosetting resin has excellent strength and heat conductivity.

Thermal Analysis of a Liquid Hydrogen Vessel (액체수소 저장용기의 열해석)

  • Kim, Seo Young;Kang, Byung Ha
    • Journal of Hydrogen and New Energy
    • /
    • v.8 no.2
    • /
    • pp.57-65
    • /
    • 1997
  • Thermal analysis has been performed to design a high-performance $LH_2$ vessel with about 1% per day evaporation loss. Analysis includes the combined insulations of MLI(Multi-Layer Insulation) and VCS (Vapor-Cooled Shield) under high vacuum. Combined insulation of MLI and VCS shows the existence of optimal location of VCS to minimize evaporation loss. Comparison of parallel-type DVCS (Double Vapor-Cooled Shield) and serial-type DVCS is also made to show the effectiveness of the system. The results indicate that the serial-type DVCS vessel is better than the parallel-type DVCS vessel with respect to overall evaporation loss. The combined insulation of SVCS (Single Vapor-Cooled Shield) with a partial MLI can give a similar performance characteristics compared to that with MLI and DVCS.

  • PDF

Synthesis, Spectral Characterization, Electron Microscopic Study and Influence on the Thermal Stability of Phosphorus-containing Dendrimer with a 4,4'-Sulphonyldiphenol at the Core

  • Dadapeer, Echchukattula;Rasheed, Syed;Raju, Chamarthi Naga
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.498-502
    • /
    • 2011
  • The divergent synthesis of novel phosphorus-containing dendrimer with 4,4'-sulphonyldiphenol at the core has been accomplished involving simple condensation reactions using $P(O)Cl_3$, $P(S)Cl_3$, 3-amino-phenol, 3-hydroxy-benzaldehyde, and 2-butyn 1, 4-diol. The final compound was a Schiff's base macromolecule possessing 4 imine bonds, 8 acetylenic bonds and 8 OH groups at the periphery. The structures of intermediate compounds were confirmed by IR, NMR ($^1H$, $^{13}C$ and $^{31}P$), LC-Mass and C, H, N analysis. The structure of the final dendrimer (5) was confirmed by IR, NMR ($^1H$, $^{13}C$ and $^{31}P$), MALDI-TOF-MS, and C, H, N analysis. The surface morphological characteristics of the final dendrimer were understood by Scanning Electronic Microscopic study (SEM). The thermal stability of the final dendrimer was studied by TGA/DTA analysis.

7Li-NMR and Thermal Analysis for Lithium Inserted into Artificial Carbon Material

  • O, Won Chun
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.4
    • /
    • pp.367-371
    • /
    • 2001
  • Lithium inserted into artificial carbon has been synthesized as a function of the Li concentration. The characteristics of these prepared compounds were determined from the studies using X-ray diffraction(XRD), solid nuclear magnetic resonance (NM R) spectrophotometric and differential scanning calorimeter(DSC) analysis. X-ray diffraction showed that lower stage intercalation compounds were formed with increasing Li concentration. In the case of the AG3, most compounds formed were of the stage 1 structure. Pure stage 1 structural defects of artificial graphite were not observed. 7Li-NMR data showed that bands are shifted toward higher frequencies with increasing lithium concentration; this is because non-occupied electron shells of Li increased in charge carrier density. Line widths of the Li inserted carbon compounds decreased slowly because of nonhomogeneous local magnetic order and the random electron spin direction for located Li between graphene layers. The enthalpy and entropy changes of the compounds can be obtained from the differential scanning calorimetric analysis results. From these results, it was found that exothermic and endothermic reactions of lithium inserted into artificial carbon are related to the thermal stability of lithium between artificial carbon graphene layers.

Numerical Analysis on Heat Transfer Characteristics of a Heat Pipe Type Solar Thermal Receiver Depending on End Wall Angle Variation (고온 히트파이프식 태양열 흡수기의 후벽 각도 변화에 따른 열전달 특성의 수치해석)

  • Park, Young-Hark;Jung, Eui-Guk;Boo, Joon-Hong;Kang, Yong-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.226-231
    • /
    • 2008
  • The heat transfer characteristics of a solar high-temperature receiver with heat pipes was investigated by numerical simulation. The concentration ratio of the solar receiver ranges 1000 and the concentrated heat is required to be transported to a certain distance for specific applications. This study deals with internal geometry variation of a solar receiver incorporating high-temperature heat pipe. The isothermal characteristics in the receiver section is of major concern. The diameter of the solar thermal receiver was 120 mm and the length was 400 mm. The angle of receiver end wall was varied between $0^{\circ}$ and $45^{\circ}$. The wall thickness of the heat pipe channel was 4mm and 48 axial channels of the same dimensions were attached to the outer wall of the receiver with even spacing in the circumferential direction. The channels are changed to high-temperature sodium heat pipes. Commercial softwares were employed to deal with the radiative heat transfer inside the receiver cavity and the conduction heat transfer along the channels. The numerical results are compared and analyzed from the view Point of high-temperature solar receiver.

  • PDF

Component Analysis of Thermally Activated Building System in Residential Buildings

  • Chung, Woong June;Lee, Yu Ji;Yoo, Mi Hye;Park, Sang Hoon;Yeo, Myoung Souk;Kim, Kwang Woo
    • Architectural research
    • /
    • v.16 no.4
    • /
    • pp.203-210
    • /
    • 2014
  • The packaged terminal air conditioner, the typical cooling system for the residential buildings, consumes a large amount of electricity in a short period time during peak hours. In order to reduce the peak load and conserve the electricity, the thermally activated building system can be used as a secondary system to handle the partial cooling load. However, the thermally activated building system may cause condensation and under-cooling. Thus, design of both systems should be performed with careful investigation in characteristics of both systems to amplify the advantages. Since the thermally activated building system has the time-delay effect which may cause under-cooling, the system is designed to handle the base load of the building. Hence, simple simulation with EnergyPlus was performed to observe the characteristics of cooling load in residential buildings. Once the possible range of the load handling ratio of the thermally activated building system was decided, characteristics of system was analyzed in terms of hardware component and operation parameters. The hardware components were analyzed in plant and system aspects and the operation parameter was evaluated in the thermal comfort aspect. As the load handling ratio increased, the thermal comfort increased due to the lower radiant mean temperatures. Within the range of thermal comfort, the several adjustments were made in setpoint temperature and electricity consumptions of difference cases were observed to decide which components and parameters were important for designing the systems.