• Title/Summary/Keyword: Thermal analysis characteristics

Search Result 2,348, Processing Time 0.032 seconds

Flatness Characteristics Analysis Technique of Attenuator Using Thermal Voltage Converter and AC Measurement Standard (열전압변환기와 교류측정표준을 사용한 감쇠기 평탄도 특성 분석 기법)

  • Cha, Yun-bae;Kim, Boo-il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.330-337
    • /
    • 2018
  • This paper proposes a technique to analyze the flatness characteristics of the attenuator at 10Hz to $50\text\tiny{MHz}$ on the basis of $1\text\tiny{kHz}$ using a Thermal Voltage Converter and AC measurement standard. In the proposed technique, the input voltage of the attenuator for each measuring frequency is supplied at the same rate as $1\text\tiny{kHz}$ using TVC, and the flatness characteristics of the attenuator are analyzed by the voltage variation indicated in the AC measurement standard. The results of the analysis of the attenuator flatness characteristics show that the maximum uncertainty of $866{\mu}V/V$ can be measured from $10\text\tiny{dB}$ to $70\text\tiny{dB}$ and the uncertainty is reduced by about 37% compared to $2.31\text\tiny{mV}$/V using the network measurement method. The improved attenuator flatness characteristic values can be applied to the frequency flatness calibration from 2.2V to 2.2mV at the low voltage of the AC measurement standard.

The Development and Performance Analysis of Compact Type Solar Thermal/Ground Coupled Heat Pump Hybrid System for Heating, Cooling and Hot water (콤팩트형 태양열/지열히트펌프 하이브리드 냉난방 및 급탕 시스템 개발 및 성능분석)

  • Baek, Nam-Choon;Jeong, Seon-Yeong;Yoon, Eung-Sang;Lee, Kyoung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.59-67
    • /
    • 2012
  • In this study,the compact type solar thermal and ground coupled heat pump hybrid system for space heating/cooling and hot water supply has been developed. This hybrid system was installed in Zero Energy Solar House(ZeSH) in KIER for the demonstration. The thermal performance and operational characteristics of this hybrid system were analysed especially. The results are as follows. (1) This hybrid system was designed in order to address the existing disadvantages of solar thermal/ground coupled heat pump system. For this design, all parts except solar collector and ground coupled heat pump were integrated into a single product in a factory. The compact type unit includes two buffer tanks, an expansion tank, pumps, valves, a controller, etc. This system has an advantage of easy installation with simple plumbing work even in narrow space. (2) The thermal charging and discharging time of the buffer tanks and its characteristics by ground coupled heat pump, and heat pump COP according to geo-source temperature and buffer storage temperature have been studied. This system was found to meet well to the heat load without any other auxiliary heating equipment. (3) The operating hours of the ground coupled heat pump as a backup device of solar thermal can be reduced significantly by using solar heat. It was also found that the minimum heating water supply setting temperature and maximum cooling water supply setting temperature make an influence on the heat pump COP. The lower heating water and the higher cooling water temperature, the higher COP. In this respect, the hybrid system's performance can be improved in ZeSH than conventional house.

Analysis of Thermal Characteristics for Areas of Musim Stream in Cheongju City (청주시 무심천 주변의 열환경 특성 분석)

  • Park, Jin-Ki;Na, Sang-Il;Park, Jong-Hwa
    • Korean Journal of Agricultural Science
    • /
    • v.37 no.1
    • /
    • pp.81-86
    • /
    • 2010
  • The urban thermal environment can be an important index to detect heat island phenomena and manage it to improve urban life quality. Cheongju is a typical plain-city that main part has been formed and developed in lowland. The Mushim stream crosses the city from south to north. We reviewed the use of thermal remote sensing in stream around areas and the thermal environments, focusing primarily on the Urban Heat Island(UHI) effect. The purpose of this study is to determine the relationship between the stream nearby urban area and the stream cooling effect of UHI. The objectives are to determine the usefulness of KOMPSAT-2 bands MS3 and MS4 for vegetation cover mapping, and the usefulness of LANDSAT TM band 6 in identifying thermal environmental characteristics and UHI. Land Surface Temperatures (LST) are retrieved by single-channel algorithm to study the UHI from the 6th band (thermal infrared band) of LANDSAT TM images and thermal radiance thermometer based on remote sensing method and the LST distribution maps are accomplished according to the retrieval results. There is also comparison of satellite-derived and in situ measured temperature. The results indicated that the LST of urban center is higher than that of suburban area, the temperature of mountain and water are the lowest area, so it is clearly proved that there are obvious UHI effects by stream. The surface temperature distribution of Mushim stream is detected $2^{\circ}C$ lower than urban area.

Investigation on transient characteristics of current leads for superconducting magnet (초전도 자석에 사용되는 전류 도입선의 과도 특성에 관한 연구)

  • 인세환;정상권
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.50-55
    • /
    • 2002
  • The transient numerical analysis was performed for vapor cooled current leads. The present numerical modeling considered that there is temperature difference between the copper lead and the helium vapor flow. This numerical modeling was compensated and validated by the experiment with commercially available 100 A current leads. The numerical modeling in this paper described thermal characteristics of overloaded current leads more accurately than the conventional steady state analysis. Proper design of overloaded current leads was suggested by indicating the appropriate overloading factor in the pulse mode operation.

  • PDF

A Study on the Thermal Characteristics of the Spindle System with Built-in Motor according to Spindle type (모터내장형 주축계의 구조에 따른 열특성 해석에 관한 연구)

  • 서창범;김수태;최대봉
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.105-110
    • /
    • 2001
  • Unsteady-state temperature distributions for spindle system with built-in motor according to spindle type are studied. For the analysis, three dimensional model is built considering heat transfer characteristics such as natural and forced convection coefficients. Temperature distributions are analyzed by using the finite element method. Results of analysis are compared.

  • PDF

Influence of Ozone Treatment on the Surface Characteristics of Montmorillonite and the Thermal Stability of Montmorillonite/polypropylene Nanocomposites (오존처리가 몬모릴로나이트의 표면특성 및 몬모릴로나이트/폴리프로필렌 나노복합재료의 열안정성에 미치는 영향)

  • Jin Sung-Yeol;Lee Jae-Rock;Park Soo-Jin
    • Composites Research
    • /
    • v.18 no.1
    • /
    • pp.23-29
    • /
    • 2005
  • In this work, the effect of ozone treatment of montmorillonite (MMT) on the surface characteristics of montmorillonite and the thermal stability of MMT/polypropylene (PP) nanocomposites was investigated. The surface properties of MMT were determined by X-ray diffraction (XRD), Fourier transform infrared (FT-IR), and X-ray photoelectron spectroscopy (XPS). Also, the thermal stability of nanocomposites was investigated in thermogravimetric analysis (TGA). As a result, it was found that the silicate interlayers of the organically modified MMT (D-MMT) were increased by about 11${\AA}$, as compared with the MMT. Also, FT-IR showed that a new peaks at $2800\~2900\;cm^{-1}$ appeared due to the $CH_2$ mode in the D-MMT The ozone treatment of the MMT led to an increase of SiO or $SiO_2$ groups on MMT surfaces, resulting in increasing the oxygen-containing functional groups on MMT. The ozonized MMT had higher thermal stability than that of untreated nanocomposites. This was due to the improvement of interfacial bonding strengths, resulting from the acid-base interfacial interactions between PP and MMT.

An Experimental Study on the Characteristics of Flux Density Distributions in the Focal Region of a Solar Concentrator (태양열 집광기의 초점 지역에 형성된 플럭스 밀도 분포의 특성)

  • Hyun, S.T.;Kang, Y.H.;Yoon, H.G.;Yoo, C.K.;Kang, M.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.31-37
    • /
    • 2002
  • This experimental study represents the results of an analysis on the characteristics of flux density distributions in the focal region of solar concentrator. The characteristics of flux density distributions are investigated to optimally design and position a cavity receiver. This deemed very useful to find and correct various errors associated with a dish concentrator. We estimated the flux density distribution on the target placed along with focal lengths from the dish vertex to experimentally determine the focal length. It is observed that the actual focal point exists when the focal length is 2.17 m. We also evaluated the position of flux centroid, and it was found that there were errors within 2 cm from the target center. The total integrated power of 2467 W was measured under focal flux distributions, which corresponds to the intercept rate of 85.8%. As a result of the percent power within radius, approximately 90% of the incident radiation is intercepted by about 0.06 m radius.

A Study on Thermal and Mechanical Behaviors of Micro Reformer (마이크로 리포머의 열 및 역학적 거동 분석)

  • Hwang W.H.;Jang J.H.;Kil J.H.;Kim S.J.;Lee R.W.;Kim S.H.;Chung K.H.;Oh Y.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.235-239
    • /
    • 2005
  • We analyzed the thermal and mechanical behaviors of micro reformer for the purpose of design verifications and modification of micro channels. The reformer designed for hydrogen generation from methanol is essential to PEM(Proton Exchange Membrane) type fuel cell. For the mobile applications, the size and the simplicity would be the most critical issues. We utilized silicon process for micro reformer to obtain the thickness thinner than 2 mm thick. We have used commercial simulation software, IDEAS, to analyze the thermal and mechanical characteristics of micro reformer structure. The heat generation rates of heaters, heat transfer rates, and fluid temperatures are derived from thermal equilibrium relation and these values were used for thermal boundary conditions. We also analyzed the thermal stresses, thermal deformations to examine the possibility of failure.

  • PDF

The Thermal Characterization of Chip Size Packages

  • Park, Sang-Wook;Kim, Sang-Ha;Hong, Joon-Ki;Kim, Deok-Hoon
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.09a
    • /
    • pp.121-145
    • /
    • 2001
  • Chip Size Packages (CSP) are now widely used in high speed DRAM. The major driving farce of CSP development is its superior electrical performance than that of conventional package. However, the power dissipation of high speed DRAM like DDR or RAMBUS DRAM chip reaches up to near 2W. This fact makes the thermal management methods in DRAM package be more carefully considered. In this study, the thermal performances of 3 type CSPs named $\mu-BGA$^{TM}$$ $UltraCSP^{TM}$ and OmegaCSP$^{TM}$ were measured under the JEDEC specifications and their thermal characteristics were of a simulation model utilizing CFD and FEM code. The results show that there is a good agreement between the simulation and measurement within Max. 10% of $\circledM_{ja}$. And they show the wafer level CSPs have a superior thermal performance than that of $\mu-BGA.$ Especially the analysis results show that the thermal performance of wafer level CSPs are excellent fur modulo level in real operational mode without any heat sink.

  • PDF

A Study on the Thermal Characteristics of Comfortable Heat-Retaining Winter Clothing (겨울용 쾌적 보온성 의복의 온열특성에 관한 연구 - 무풍환경하에서 -)

  • Song, Min-Kyu;Kwon, Myoung-Sook
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.6
    • /
    • pp.24-34
    • /
    • 2008
  • The purpose of this study was to create a database of information on fabric factors(i.e., fabric insulation, fabric weight, clothing weight, fabric thickness, air permeability, and water vapor resistance) of clothing used for insulations, to compare them according to clothing types, and to estimate thermal resistance of clothing using these factors. A total of 25 kinds of clothing were selected(9 types for suits, 6 types of jacket, 5 types for shirts, and 5 types for trousers). The results of this study were as follows; Thermal insulation of clothing showed the highest positive correlation(0.85, p>0.01) with thermal insulation of fabric and very high positive correlation with water vapor resistance, fabric thickness, fabric weight, and clothing weight, respectively, 0.77, 0.77, 0.73, 0.71(p>0.01). Fabric weight of jacket was higher than that of shirts and trousers. Air permeability of shirts was the highest of clothing types. Clothing insulation of jacket was higher than that of shirts and trousers and its fabric insulation was also the highest of clothing types. Regression analysis showed that fabric thickness, water vapor resistance, and fabric weight would be useful factors for estimating the thermal resistance of clothing.