• Title/Summary/Keyword: Thermal Power Plants

Search Result 522, Processing Time 0.03 seconds

Evaluation of Reference Temperature on Pressurized Thermal Shock for Domestic Pressurized Water Reactors (국내 가압경수형 원자로에 대한 가압열충격 기준온도 평가)

  • Choi, Young Hwan;Park, Jeong Soon;Jhung, Myung Jo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.42-46
    • /
    • 2010
  • The evaluation method for the failure frequency of reactor vessel under pressurized thermal shock(PTS) is developed using probabilistic fracture mechanics. The probabilistic reactor integrity evaluation code, named R-PIE code, is developed. The validity and uncertainty of the R-PIE code is investigated. The reactor failure frequencies under PTS for Kori-1 nuclear power plant and other type of domestic nuclear power plants are evaluated. The reference PTS temperature for domestic nuclear power plants is obtained for the rule making against PTS failure.

  • PDF

Careful Determination of Inservice Inspection of piping by Computer Analysis in Nuclear Power Plant (배관해석에 의한 원전 배관부의 검사부위 선정)

  • Lim, H.T.;Lee, S.L.;Lee, J.P.;Kim, B.C.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.12 no.2
    • /
    • pp.14-20
    • /
    • 1992
  • Stress analysis has been performed using computer program ANSYS in the pressurizer surge line in accordance with ASME Sec. III in order to predict possibility of fatigue failure due to thermal stratification phenomena in pipes connected to reactor coolant system of nuclear power plants. Highly vulnerable area to crack generation has been chosen by the analysis of fatigue due to thermal stress in pressurizer surge line. This kind of result can be helpful to choose the location requiring intensive care during inservice inspection of nuclear power plants.

  • PDF

Sensitivity analysis of thermal-hydraulic parameters to study the corrosion intensity in nuclear power plant steam generators

  • Tashakor, S.;Afsari, A.;Hashemi-Tilehnoee, M.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.394-401
    • /
    • 2019
  • The failure of steam generators (SGs) due to corrosion is one of the most important problems in power plants. Impurities usually accumulate in the hot sides of SG and form deposits on the SG surfaces. In this paper, the sensitivity analysis of the accumulation of water impurities in the heat exchangers of nuclear power plants is presented. The convection-diffusion equation of the liquid phase on the heated surfaces is derived and then solved by the finite volume method. Also, the effects of the thermal-hydraulic parameters in the form of dimensionless numbers, such as $Pe_q$, $Pe_u$, $k_q$(relative solubility of impurity between the steam and water) on the impurities concentration are studied.

A Study on the Application of the Solar Energy Seasonal Storage System Using Sea water Heat Source in the Buildings (해수냉열원을 이용한 태양열계간축열시스템의 건물냉방 적용에 관한 연구)

  • Kim, Myung-Rae;Yoon, Jae-Ock
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.56-61
    • /
    • 2009
  • Paradigm depending only on fossil fuel for building heat source is rapidly changing. Accelerating the change, as it has been known, is obligation for reducing green house gas coming from use of fossil fuel, i.e. reaction to United Nations Framework Convention on Climate Change. In addition, factors such as high oil price, unstable supply, weapon of petroleum and oil peak, by replacing fossil fuel, contributes to advance of environmental friendly renewable energy which can be continuously reusable. Therefore, current new energy policies, beyond enhancing effectiveness of heat using equipments, are to make best efforts for national competitiveness. Our country supports 11 areas for new renewable energy including sun light, solar heat and wind power. Among those areas, ocean thermal energy specifies tidal power generation using tide of sea, wave and temperature differences, wave power generation and thermal power generation. But heat use of heat source from sea water itself has been excluded as non-utilized energy. In the future, sea water heat source which has not been used so far will be required to be specified as new renewable energy. This research is to survey local heating system in Europe using sea water, central solar heating plants, seasonal thermal energy store and to analyze large scale central solar heating plants in German. Seasonal thermal energy store necessarily need to be equipped with large scale thermal energy store. Currently operating central solar heating system is a effective method which significantly enhances sharing rate of solar heat in a way that stores excessive heat generating in summer and then replenish insufficient heat for winter. Construction cost for this system is primarily dependent on large scale seasonal heat store and this high priced heat store merely plays its role once per year. Since our country is faced with 3 directional sea, active research and development for using sea water heat as cooling and heating heat source is required for seashore villages and building units. This research suggests how to utilize new energy in a way that stores cooling heat of sea water into seasonal thermal energy store when temperature of sea water is its lowest temperature in February based on West Sea and then uses it as cooling heat source when cooling is necessary. Since this method utilizes seasonal thermal energy store from existing central solar heating plant for heating and cooling purpose respectively twice per year maximizing energy efficiency by achieving 2 seasonal thermal energy store, active research and development is necessarily required for the future.

  • PDF

Status and Perspective of Biomass Co-firing to Pulverized Coal Power Plants (미분탄 석탄화력발전에서의 바이오매스 혼소 동향 및 전망)

  • Yang, Won
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.525-529
    • /
    • 2016
  • Biomass co-firing to existing thermal power plants is one of the most economical and efficient way to reduce $CO_2$ emission from the plant. There are several methods of co-firing and it can be categorized into (1) Parallel co-firing, (2) Indirect co-firing, and (3) Direct co-firing. Parallel co-firing is the most expensive way to high-ratio co-firing because it requires biomass dedicated boiler. Direct co-firing is widely used because it does not need high capital cost compared with the other two methods. Regarding the direct co-firing, it can be classified into three methods- Method 1 does not need retrofit of the facilities because it uses existing coal mills for pulverizing biomass fuels. In this case high-ratio co-firing cannot be achieved because of poor grindability of biomass fuels. Method 2 needs biomass-dedicated mills and revision of fuel streams for the combustion system, and Method 3 needs additional retrofit of the boiler as well as biomass mills. It can achieve highest share of the biomass co-firing compared with other two methods. In Korea, many coal power plants have been adopting Method 1 for coping with RPS(Renewable portfolio standards). Higher co-firing ratio (> 5% thermal share) has not been considered in Korean power plants due to policy of limitation in biomass co-firing for securing REC(Renewable Energy Certificate). On the other hand, higher-share co-firing of biomass is widely used in Europe and US using biomass dedicated mills, following their policy to enhance utilization of renewable energy in those countries. Technical problems which can be caused by increasing share of the biomass in coal power plants are summarized and discussed in this report. $CO_2$ abatement will become more and more critical issues for coal power plants since Paris agreement(2015) and demand of higher share of biomass in the coal power plants will be rapidly increased in Korea as well. Torrefaction of the biomass can be one of the best options because torrefied biomass has higher heating value and grindability than other biomass fuels. Perspective of the biomass torrefaction for co-firing is discussed, and economic feasibility of biomass torrefaction will be crucial for implementation of this technology.

Development of Turbine Digital Control System for Thermal Power Plants (국내 개발 디지털 터빈제어시스템의 적용)

  • Woo, Joo-Hee;Jeong, Chang-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2141-2143
    • /
    • 2001
  • 국내 한 석탄화력 발전소의 아날로그 터빈 제어시스템을 최초로 국내 기술에 의해 디지털 터빈 제어시스템으로 개조하여 현재 성공적으로 운전되고 있다. 적용된 시스템의 구성 및 기능에 대해서 언급하고자 한다.

  • PDF

동굴 안정성 입력자료로서의 탄성계수(Es)결정

  • 김정대;박인식
    • Tunnel and Underground Space
    • /
    • v.1
    • /
    • pp.32-38
    • /
    • 1991
  • 9 nuclear power plants are presently in operation in Korea. They produce radioactive waste of which the most long-lived radioactive elements need to be safely stored for hundreds of thousands of years, isolated from humanity and the environment. The safe disposal of high level radioactive waste in mined cavities requires knowledge of the mechanical. thermal and fluid flow characteristics of rock as perturbed by a thermal pulse The literature review was performed to assemble data on the following properties: modulus tensile strength compressive strength thermal expansion specific heat, thermal conductivity thermal diffusivity and permeability.

  • PDF

Review on the New Fire Protection Standard for Nuclear Power Plants and Investigation for the Applicability of the Performance-Based Fire Modeling

  • Jee, Moon-Hak;Hong, Sung-Yull;Sung, Chang-Kyung;Kim, In-Hwang
    • Nuclear Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.259-267
    • /
    • 2002
  • NFPA-803 has been referred as the Fire Protection Standard at the Nuclear Power Plants of Pressurized Water Reactor. This Standard has been used as the fire protection regulation, containing prescriptive requirements with deterministic methodology. Recently, with cumulative efforts by the U.S. Nuclear Regulatory Commission and Utilities in America to establish a new Standard, including a quantitative evaluation methodology, NFPA-805, the Performance-Based Standard for FIRE Protection for Light Water Reactor Electric Generating Plants was issued and approved by the American National Standards Institute as an American National Standard with an effective date of February 9, 2001. This paper presents an analysis result from the computer modeling for the fire simulation In addition, it proposes the idea that this kind of analytic method can be available for the facilities design of fire prevention and protection fields, as well as an evaluation for the fire suppression system with a quantitative analysis for the thermal phenomena in fire compartments in Nuclear Power Plants.