• Title/Summary/Keyword: Thermal Environmental Elements

Search Result 89, Processing Time 0.026 seconds

Characteristics of Mesoscale Circulation with the Detailed Building Distribution in Busan Metropolitan Area (부산지역 빌딩 분포 상세화에 따른 중규모 순환 특성)

  • Son, Jeong-Ock;Lee, Hwa-Woon;Lee, Soon-Hwan
    • Journal of Environmental Science International
    • /
    • v.21 no.2
    • /
    • pp.203-215
    • /
    • 2012
  • In order to clarify the impacts of thermal difference in atmospheric boundary layer due to the different sophistication of building information in Busan metropolitan areas, several numerical simulations were carried out. ACM (Albedo Calculation Model) and WRF (Weather Research and Forecasting) was applied for estimating albedo and meteorological elements in urban area, respectively. In comparison with coarse aggregated and small buildings, diurnal variation of albedo is highly frequent and its total value tend to be smaller in densely aggregated and tall buildings. Estimated TKE and sensible heat flux with sophisticatedly urban building parameterization is more resonable and valid values are mainly induced by urban building sophistication. The simulation results suggest that decreased albedo and increased roughness due to skyscraper plays an important role in the result of thermal change in atmospheric boundary layer.

A Study on the Thernal Conductivity Characteristics of Discarded Tire Powder-Soil Mixture (폐타이어 파우더 혼합토의 열전도율 특성에 관한 연구)

  • Kim, Hak-Sam;Seo, Sang-Youl;NakamuRa, Dai;Yamashita, Satoshi;Suzuki, Teruyuki
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.5
    • /
    • pp.27-36
    • /
    • 2010
  • Thermal conductivities using the thermal probe method were determined for frost susceptible soil with three types of discarded tire powder under the condition of a temperature variation from $-20^{\circ}C{\sim}+10^{\circ}C$. Also, the amount of unfrozen water contents was measured by the pulsed NMR method. The variation of unfrozen water content in the experimental condition could be expressed as a function of temperature given by an exponential equation. A new model for calculating the thermal conductivity of frozen soil was proposed. It is extended from the two element method and subdivided into three constituent elements.

A Study on the Relationship between the Summertime Night Cooling Rate and Meteorological Elements in Daegu (대구의 여름철 야간 냉각량과 기상요소와의 관련성 연구)

  • Kim, Ha-Young;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.30 no.10
    • /
    • pp.821-831
    • /
    • 2021
  • The relationship between night cooling rate and meteorological elements was investigated over the past five years (2016-2020), using weather data from the new (Daegu(143)) and old (Shinam(860)) Daegu Regional Meteorological Agency located in the suburban and urban regions, respectively. There was a correlation between the total daily amount of solar radiation (Stot) and the night cooling rate in the both regions. However, a higher correlation was observed at the new Daegu Regional Meteorological Agency station (Daegu(143)). In particular, data from the new Daegu Regional Meteorological Administration's observatory, which experiences a low thermal storage effect caused by artificial structures, showed a higher correlation between nighttime cooling and weather factors. The reason for this is that the lesser the heat storage effect caused by the artificial structures, the better the effect of surface radiation cooling on temperature reduction. These findings confirm that the correlation between night cooling and weather factors can be used to assess the impact of artificial structures in cities.

Investigation and Analysis of Patents for the Thermal Bridge Breaker in Green Buildings (그린건축을 위한 열교차단 특허기술의 조사 및 분석 연구)

  • Kim, Young-Ho;Kim, Hyung-Joon;Lee, Hee-Young
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.2
    • /
    • pp.35-43
    • /
    • 2013
  • The green building is one of biggest factors to go the goal of energy saving and environmental conservation, "reduction of energy consumption, friendly energy technology, recycling of resource, and environmental pollution reduction technology. The purpose of these green buildings realized by the energy-saving technology such as the thermal bridge breaker(or thermal bridge block). Thermal bridges are localized elements that penetrate insulated portions of building envelope that results in heat loss. The purpose of this paper is to describe the technical interactions for patents of a thermal bridge breaker(TTB) used in green building practices, and be subject to investigation to TTB in the leading countries, that is, United State, Europe Union, Japan, and Korea. As a result, there are four TTB categories(roof, wall-slab connection, opening, footing) in house or building. The TTB categories is remarkable technology that is apparatus in slab-wall joints and sealing element of opening frame in walls.

Characteristics of Meteorological Elements and Long-wave Radiation in the Greater Daegu Area During Winter (동절기 대구지역의 기상요소와 장파복사 특성 분석)

  • Baek, Chang-Hyeon;Choi, Dong-Ho;Lee, Bu-Yong;Lee, In-Gyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.6
    • /
    • pp.93-102
    • /
    • 2017
  • Interpretation of relevance between long-wave radiation and meteorological elements is recognized as an essential element for understanding the underlying mechanism of urban thermal environment formation. In this study, we analyzed relation between three elements : long-wave radiation, temperature, and lower-middle class cloudiness. The correlation was analyzed through field observations. The results are as follows. (1) Temperatures and long-wave radiation increased from January to March. This phenomenon has been confirmed in urban and suburban areas. (2) Long-wave radiations showed a tendency to increase clearly with increasing cloudiness.

A Study on the Summer Thermal Environment in Korean Urban Residences (도시주택의 여름철 온열환경에 관한 측정실험 연구)

  • 윤정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.27 no.1
    • /
    • pp.71-83
    • /
    • 1989
  • This is a basic study designed to discover the most comfortable thermal environment for Korean residences. The purpose of the research is to observe and measure the summer thermal environment in Korean urban detached single family houses and apartments by utilising proposed evaluation standards and methods. The technique used involves the measurement of environmental elements, such as indoor temperature, relative humidity and radiant temperature both in detached single family houses and apartments. Also, in order to understand the resident's thermal comfort response. ASHRAE' thermal sensation 9th level, indoor temperature 5th level, and thermal discomfort 4th level in the psycho-physical voting scale (1972) was used. In conclusion, among Korean urban residences, detached single family houses provided a more stable thermal environment than apartments, as shown by physical psychological evaluations. The possible reason for such stability in detached single family houses may be the usage of reinforced concrete structures which maintain consistent temperatures.

  • PDF

A Study on the Indoor Climate Characteristics and Thermal Sensation Vote of the Earthen House in Summer Season (흙집의 하절기 실내 물리적 환경 특성과 온열감에 관한 연구)

  • Chan, Kook;Jeon, Ji-Hyeon;Shin, Yong-Gyu
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.9-16
    • /
    • 2006
  • The researches on the environmental friendly buildings have carried out on the materials, environmental property, technical elements and etc., and various buildings with these green materials have built and under construction nowadays and became a new trend of the green building. And recently, new building technique which builds the wall with the soil and wood and very easy to construct (called M Earthen House) was introduced as the green building and rapidly propagated. But the research on the indoor climatic characteristics, the ability to control the environmental comfort and the influence to the human beings of these buildings are not sufficiently identified yet. In this paper, the indoor environmental characteristics and the temperature controlling ability of these buildings in summer season were measured and analysed by the Portable Indoor Air Quality Monitor(BABUC/A, LSI) measuring equipments, ana the subjective test on the thermal environment of the subjects were carried out to evaluate the thermal comfort. The results can be summarized as follows; 1) Compared to the outdoor dry bulb temp.($15.4{\sim}28.7^{\circ}C$), the indoor temp. was $19.5{\sim}26.8^{\circ}C$. It showed the temperature controlling ability of the M earthen house was outstanding. And the indoor relative humidity, compared to the outdoor($45.4{\sim}100%$), was $58.1{\sim}76.4%$, it showed the humidity controlling ability of the M earthen house was also outstanding. 2) The thermal environment was evaluated as 'comfort'(neutral-slightly warm) and the humidity was also evaluated as 'comfort'(neutral-slightly humid). So, the results of the physical and subjective evaluation on the indoor thermal comfort in summer season were 'neutral' and 'comfort' coincidently, it was confirmed that the controlling ability of the indoor temperature and humidity of the M earthen house was very excellent.

Thermal and Hygroscopic Properties of Indoor Particulate Matter Collected on an Underground Subway Platform

  • Ma, Chang-Jin;Lee, Kyoung-Bin;Zhang, Daizhou;Yamamoto, Mariko;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • In order to clarify the thermal and hygroscopic properties of indoor particulate matter (PM) in a semiclosed subway space, which is critically important for understanding of the distinctive particle formation processes as well as the assessment of their health effects, the size-resolved PMs (i.e., $PM_{2.5}$ and $PM_{10-2.5}$) were intensively collected on the platform of Miasageori station on the Seoul Subway Line-4. The elemental concentrations in soluble and insoluble fractions were determined by PIXE from the bulkily pretreated $PM_{2.5}$. The thermal and hygroscopic characteristics of individual particles were investigated via a combination of the unique pretreatment techniques (i.e., the high-temperature rapid thermal process and the water dialysis) and SEM-EDX analysis. Iron and calcium were unequaled in insoluble and soluble $PM_{2.5}$ fractions, respectively, with overwhelming concentration. The SEM-EDX's elemental net-counts for the pre- and post-pyrolyzed PMs newly suggest that magnesium and several elements (i.e., silica, aluminum, and calcium) may be readily involved in the newly generated subway fine PM by a high-temperature thermal processing when trains are breaking and starting. Through the water dialysis technique, it turned out that calcium has meaningful amount of water soluble fraction. Furthermore, the concentrations of the counter-ions associated with the calcium in subway $PM_{10-2.5}$ were theoretically estimated.

A Study on the Thermal Sensation Vote of the Log House in Winter Season (통나무집의 동절기 실내 온열감 평가에 관한 연구)

  • Min, Byeong-Cheol;Jeon, Ji-Hyeon;Shin, Yong-Gyu;Kang, Sang-Woo;Kook, Chan
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.297-300
    • /
    • 2006
  • Various buildings constructed by environmentally friendly resources are being built in KOREA. Especially the building made by the wood, which has environmental characteristics that the reinforced concrete and brick doesn't have, are acknowledged with its superiority. Then, studies on indoor thermal control capability of the wooden building and influence of its indoor environment to sensory environment of occupants are not enough proceed. Thus, there were proceeded 24 hours measurements for indoor and outdoor thermal environmental elements of Log Cabins and the hourly subjective tests to evaluate indoor amenity of occupants in this study. The results of the study are following: 1) Upon evaluation on thermal environment elements, indoor and outdoor dry bulb temp were 22.0$^{\circ}C$ and -2.9$^{\circ}C$, and Indoor and outdoor average relative humidity were 25.8%and 52.7%. Differences of indoor and outdoor temperature and humidity were 24.9$^{\circ}C$ and 26.9%. 2) Upon contrastive analysis between the results of subjective tests, warm and cold sensation vote, and PMV (Predicted Mean Vote) and PPD (Predicted Percent Dissatisfaction), values of subjective tests W.9

  • PDF

Study on Energy Saving Possibilities through Analysis of Environment Control Elements & Natural Ventilation Performance using the CFD & Measurement (CFD와 실측을 이용한 환경제어요소 도입 및 주택 자연환기 성향 검토를 통한 에너지 절감가능성 고찰)

  • Oh, Byoungchull;Lee, Sunyoung
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.27-37
    • /
    • 2014
  • Heat island is caused by changes of land coverage structure of cities and use of energy in buildings. As a result energy use in buildings get to increase further followed by rising of GHG emission and deteriorating climate change. Eco-friendly housing complex is a kind of plan that applies environmental control elements like water and green spaces to housing complex. With these methods, it can be expected to create thermal environment of indoor and outdoor. In this paper quantitative examination is studied on using CFD to find out the effects of river, water permeable, parks and planting on thermal environment. And by comparing field measurements with CFD results which are aimed to development phase housing complex, feasibility and usability of the CFD analysis results are confirmed. And also, analysis on the ventilation performance followed by natural ventilation system is analyzed by selecting one building in housing complex. Based on the results, the possibilities of energy reduction through making thermal environment and applying natural ventilation are studied. With these outcomes, creating thermal conditions and using natural ventilation would be contributed to GHG reduction.