• 제목/요약/키워드: Thermal Environment Evaluation

검색결과 383건 처리시간 0.025초

개별공조시스템(PACA)을 적용한 작업공간에서의 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environment and Evaluation of Thermal Comfort in Task Area with Personal Air-Conditioning System(PACS))

  • 최익순;정광섭;박영철;한화택;이정재
    • 설비공학논문집
    • /
    • 제13권2호
    • /
    • pp.106-114
    • /
    • 2001
  • The office environment of the building has been significantly changed and the office automation(OA) for productivity improvement and efficiency has proceeded. According to thee trends, the concept of office environment was transferred from conventional \"working space\" to \"living space\" or \"creative space\". Thus, occupants in office building have demanded more comfortable and advanced task environment. The objective of this paper is to evaluate the indoor environment of working space with personal air conditioning system using the measurements of environmental comfort parameters and the questionnaire survey of occupants、 thermal sensation response to the environment.n response to the environment.

  • PDF

해양플랜트 사무공간의 공조 쾌적성 평가에 관한 연구 (The Study for Evaluation of thermal comfort in office on offshore)

  • 임홍석;김판중
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2017년도 특별논문집
    • /
    • pp.67-72
    • /
    • 2017
  • This paper presents on the evaluation of thermal comfort in office on offshore. In living quarter of offshore, strict air conditioning performance is required to office on offshore and displacement ventilation is applied to office space which rooms are required to confirm the thermal environment. The computational fluid dynamics (CFD) is performed to calculate the temperature, air velocity in office and thermal comfort such as PPM & PPD is evaluated by the CFD result.

  • PDF

도시주택의 여름철 온열환경에 관한 측정실험 연구 (A Study on the Summer Thermal Environment in Korean Urban Residences)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제27권1호
    • /
    • pp.71-83
    • /
    • 1989
  • This is a basic study designed to discover the most comfortable thermal environment for Korean residences. The purpose of the research is to observe and measure the summer thermal environment in Korean urban detached single family houses and apartments by utilising proposed evaluation standards and methods. The technique used involves the measurement of environmental elements, such as indoor temperature, relative humidity and radiant temperature both in detached single family houses and apartments. Also, in order to understand the resident's thermal comfort response. ASHRAE' thermal sensation 9th level, indoor temperature 5th level, and thermal discomfort 4th level in the psycho-physical voting scale (1972) was used. In conclusion, among Korean urban residences, detached single family houses provided a more stable thermal environment than apartments, as shown by physical psychological evaluations. The possible reason for such stability in detached single family houses may be the usage of reinforced concrete structures which maintain consistent temperatures.

  • PDF

통나무집의 동절기 실내 온열환경 요소의 측정과 온열감 평가에 관한 연구 (A Study on Examination of Indoor Thermal Environment Elements and Thermal Sensation Vote of Log Cabins in Winter Season)

  • 민병철;전지현;국찬
    • 한국주거학회논문집
    • /
    • 제18권2호
    • /
    • pp.21-27
    • /
    • 2007
  • Various buildings constructed by environmentally friendly resources are being built in KOREA. Especially as the wood has distinctive ecological merits in comparison with reinforced concrete and brick, the buildings made by the wood are acknowledged with its superiority of ecological value. Enough field studies for their thermal environment, however, haven't been done. In this study, to investigate indoor environmental condition and occupants' response to it of Log Cabin in Gyeongsangnam-do Hamyang Country Jirisan Natural Recreation Forest, examination of indoor thermal environment and field subjective evaluation have been done in that fundamental information of thermal environment characteristics can be suggested. The results are following; 1) Thermal environment of the Log Cabins; Indoor and outdoor mean dry bulb temperature were $21.9^{\circ}C$ and $-3.1^{\circ}C$, and Indoor and outdoor average relative humidity were 25.8% and 52.1%. These results are below ASHRAE; dry bulb temp. $22.0^{\circ}C$, humidity 30%, and above domestic standards; dry bulb temp. $18{\sim}20.0^{\circ}C$, humidity $40{\sim}60%$. 2) Result of subjective evaluation; Thermal sensation and its comfort were evaluated as 'slightly uncomfortable' because of 'slightly warm'. And humid sensation and its comfort were evaluated as 'slightly uncomfortable' because of 'slightly warm'. 3) Result of vertical temperature and humidity; Vertical temperature difference from head to ankle was $0.54^{\circ}C$ which means most occupants may feel comfortable.

도시근린공원의 열환경 개선을 위한 열쾌적성 평가 (An Evaluation of Thermal Comfort on Urban Neighborhood Park for Improving Thermal Environment)

  • 임은나;이우성;최철현;송봉근;정성관
    • 한국지리정보학회지
    • /
    • 제16권4호
    • /
    • pp.153-170
    • /
    • 2013
  • 본 연구는 도시 근린공원의 열쾌적성을 평가하고 이에 따른 열환경 개선방안을 도출하고자 연구를 진행하였다. 먼저 공원의 주요 열환경 인자의 분포특성 및 공간 유형별 차이를 평가한 결과, 기온, 상대습도, 풍속의 경우 공간적으로 뚜렷한 차이를 보이지 않았다. 그러나 평균복사온도는 공간의 개방정도 및 포장재질에 따라 큰 차이를 나타내는 것으로 확인되었다. 추출된 열환경 인자를 토대로 공간 유형에 따른 열쾌적성을 평가한 결과, 광장의 PMV(Predicted Mean Vote, 예상온열감) 지수가 4.39로 가장 높게 나타났으며, 동선의 경우 2.58, 녹지 1.90 그리고 휴게공간은 0.42로 평가되었다. 이러한 열쾌적성을 결정하는 열환경 요인에 대한 중요도를 평가해보기 위하여 PMV 회귀모형을 구축한 결과, 평균복사온도(1.084), 풍속(-0.280), 기온(0.013), 상대습도(-0.009)의 순으로 PMV에 대한 상대적인 중요도가 높게 나타났다. 열환경적 측면에서 개선이 필요한 지역을 대상으로 시나리오 분석을 실시한 결과, 반사율, 색상, 포장재질의 물리적 특성 변화를 통해 인체가 체감하는 열쾌적성을 향상시킬 수 있으며, 실제 공원에 이를 적용하여 개선안을 마련할 수 있을 것으로 판단된다.

전통온돌방의 실내온열환경 및 온열감에 관한 연구 (Evaluation of Indoor Thermal Environment and Thermal Sensation in Traditional Ondol Room)

  • 김난행;손장열
    • 한국주거학회논문집
    • /
    • 제15권2호
    • /
    • pp.19-25
    • /
    • 2004
  • The aim of the research was to evaluate the characteristics of indoor thermal environment and thermal sensation in the traditional Ondol room. Indoor thermal factors including air temperature, operative temperature, floor surface temperature, relative humidity, PMV, OT were measured, and survey was carried out to understand subjective responses of resident's related to indoor thermal environment in Ondol room. The analysed houses are: the Chung hyo dang(the head house of Ryu family in Andong) and the Pyeung won jung(the traditional house in Yesan). The purpose of the survey was to know the relationship between resident's sensation and thermal environmental indicators such as air temperature, relative humidity, floor surface temperature, OT. The experimental results have pointed out how Ondol room may lead to comfortable and uniform indoor thermal environments.

액체흡수제 이용 태양열 공조시스템의 하계 능력에 관한 연구 (Research on the Performance of a Solar Air Conditioning System using a Liquid Desiccant in Summer)

  • 최광환;윤정인;김보철
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.33-38
    • /
    • 2002
  • In order to find out whether solar air conditioning system could be applied to building or not, the performance and evaluation on thermal environment of the system suggested was done during summer. A solar model house was constructed to find out the performance and thermal environment evaluation when it actually operated outside. As a result, regeneration rate increased rapidly when LiCl solution temperature was over $50^{\circ}C$ and the regeneration rate was $13\sim15kg$ during 9 hours operation. Furthermore the dehumidification rate was 12kg at maximum during 10 hours operating of a dehumidifier and indoor temperature and relative humidity was $28.4^{\circ}C$ and 39.1% in average respectively. On evaluation of thermal environment during summer, PMV value was slightly high, but thermal sensation vote was 71% within the comfort zone.

열성층 및 냉각재 환경이 오스테나이트 배관의 피로수명에 미치는 영향 평가 (Evaluation of Thermal Stratification and Primary Water Environment Effects on Fatigue Life of Austenitic Piping)

  • 최신범;우승완;장윤석;최재붕;김영진;이진호;정해동
    • 대한기계학회논문집A
    • /
    • 제32권8호
    • /
    • pp.660-667
    • /
    • 2008
  • During the last two decades, lots of efforts have been devoted to resolve thermal stratification phenomenon and primary water environment issues. While several effective methods were proposed especially in related to thermally stratified flow analyses and corrosive material resistance experiments, however, lack of details on specific stress and fatigue evaluation make it difficult to quantify structural behaviors. In the present work, effects of the thermal stratification and primary water are numerically examined from a structural integrity point of view. First, a representative austenitic nuclear piping is selected and its stress components at critical locations are calculated in use of four stratified temperature inputs and eight transient conditions. Subsequently, both metal and environmental fatigue usage factors of the piping are determined by manipulating the stress components in accordance with NUREG/CR-5704 as well as ASME B&PV Codes. Key findings from the fatigue evaluation with applicability of pipe and three-dimensional solid finite elements are fully discussed and a recommendation for realistic evaluation is suggested.

하계 및 동계 실내 온열 환경 특성과 쾌적성 평가에 대한 연구 (A Study on Characteristics of Indoor Thermal Environment and Comfort Evaluation in Summer and Winter)

  • 고경태;박종일;김경훈
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1998년도 추계학술발표 논문집
    • /
    • pp.88-93
    • /
    • 1998
  • The purpose of this study was to examine theory about indoor thermal comfort-environment as well as to determine thermal sensation and physical responses for men in summer and winter indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart rate(Electrocardiogram, ECG), Electroencephalo gram(EEG) were examined. We found that comfort of people was achieved at SET*. 24.7$^{\circ}C$, -0.82${\alpha}$-wave) both in summer and in winter.

  • PDF

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • 제17권2호
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.