• Title/Summary/Keyword: Thermal Environment Evaluation

Search Result 382, Processing Time 0.031 seconds

Characteristics of Thermal Environment and Evaluation of Thermal Comfort in Task Area with Personal Air-Conditioning System(PACS) (개별공조시스템(PACA)을 적용한 작업공간에서의 온열환경 특성 및 쾌적성 평가)

  • 최익순;정광섭;박영철;한화택;이정재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.106-114
    • /
    • 2001
  • The office environment of the building has been significantly changed and the office automation(OA) for productivity improvement and efficiency has proceeded. According to thee trends, the concept of office environment was transferred from conventional \"working space\" to \"living space\" or \"creative space\". Thus, occupants in office building have demanded more comfortable and advanced task environment. The objective of this paper is to evaluate the indoor environment of working space with personal air conditioning system using the measurements of environmental comfort parameters and the questionnaire survey of occupants、 thermal sensation response to the environment.n response to the environment.

  • PDF

The Study for Evaluation of thermal comfort in office on offshore (해양플랜트 사무공간의 공조 쾌적성 평가에 관한 연구)

  • Lim, Hongseok;Kim, Panjung
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2017.10a
    • /
    • pp.67-72
    • /
    • 2017
  • This paper presents on the evaluation of thermal comfort in office on offshore. In living quarter of offshore, strict air conditioning performance is required to office on offshore and displacement ventilation is applied to office space which rooms are required to confirm the thermal environment. The computational fluid dynamics (CFD) is performed to calculate the temperature, air velocity in office and thermal comfort such as PPM & PPD is evaluated by the CFD result.

  • PDF

A Study on the Summer Thermal Environment in Korean Urban Residences (도시주택의 여름철 온열환경에 관한 측정실험 연구)

  • 윤정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.27 no.1
    • /
    • pp.71-83
    • /
    • 1989
  • This is a basic study designed to discover the most comfortable thermal environment for Korean residences. The purpose of the research is to observe and measure the summer thermal environment in Korean urban detached single family houses and apartments by utilising proposed evaluation standards and methods. The technique used involves the measurement of environmental elements, such as indoor temperature, relative humidity and radiant temperature both in detached single family houses and apartments. Also, in order to understand the resident's thermal comfort response. ASHRAE' thermal sensation 9th level, indoor temperature 5th level, and thermal discomfort 4th level in the psycho-physical voting scale (1972) was used. In conclusion, among Korean urban residences, detached single family houses provided a more stable thermal environment than apartments, as shown by physical psychological evaluations. The possible reason for such stability in detached single family houses may be the usage of reinforced concrete structures which maintain consistent temperatures.

  • PDF

A Study on Examination of Indoor Thermal Environment Elements and Thermal Sensation Vote of Log Cabins in Winter Season (통나무집의 동절기 실내 온열환경 요소의 측정과 온열감 평가에 관한 연구)

  • Min, Byeong-Cheol;Jeon, Ji-Hyeon;Kook, Chan
    • Journal of the Korean housing association
    • /
    • v.18 no.2
    • /
    • pp.21-27
    • /
    • 2007
  • Various buildings constructed by environmentally friendly resources are being built in KOREA. Especially as the wood has distinctive ecological merits in comparison with reinforced concrete and brick, the buildings made by the wood are acknowledged with its superiority of ecological value. Enough field studies for their thermal environment, however, haven't been done. In this study, to investigate indoor environmental condition and occupants' response to it of Log Cabin in Gyeongsangnam-do Hamyang Country Jirisan Natural Recreation Forest, examination of indoor thermal environment and field subjective evaluation have been done in that fundamental information of thermal environment characteristics can be suggested. The results are following; 1) Thermal environment of the Log Cabins; Indoor and outdoor mean dry bulb temperature were $21.9^{\circ}C$ and $-3.1^{\circ}C$, and Indoor and outdoor average relative humidity were 25.8% and 52.1%. These results are below ASHRAE; dry bulb temp. $22.0^{\circ}C$, humidity 30%, and above domestic standards; dry bulb temp. $18{\sim}20.0^{\circ}C$, humidity $40{\sim}60%$. 2) Result of subjective evaluation; Thermal sensation and its comfort were evaluated as 'slightly uncomfortable' because of 'slightly warm'. And humid sensation and its comfort were evaluated as 'slightly uncomfortable' because of 'slightly warm'. 3) Result of vertical temperature and humidity; Vertical temperature difference from head to ankle was $0.54^{\circ}C$ which means most occupants may feel comfortable.

An Evaluation of Thermal Comfort on Urban Neighborhood Park for Improving Thermal Environment (도시근린공원의 열환경 개선을 위한 열쾌적성 평가)

  • Lim, Eun-Na;Lee, Woo-Sung;Choi, Chul-Hyun;Song, Bong-Geun;Jung, Sung-Gwan
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.16 no.4
    • /
    • pp.153-170
    • /
    • 2013
  • This study was conducted to analyze the thermal comfort in the urban neighborhood park and to obtain a plan for improvement of the thermal environment. First, in the result of the analysis of the distribution characteristics of the park's main thermal environment factors and differences among types of space, temperature, relative humidity, and wind speed did not show a clear difference spatially. However, the median radiant temperature showed great differences according to the openness of the space and the covering material. According to the evaluation of thermal comfort by types of space based on derived thermal environmental factors, the PMV value of the square was the highest at 4.39, the paths showed 2.58, greenery 1.90, and resting spaces 0.42. In the result of the PMV regression model established for the evaluation of the significance of these thermal environment factors that decide thermal comfort, it showed that the relative significance to the PMV was as follows in decreasing order: median radiant temperature(1.084), wind speed(-0.280), temperature(0.013), and relative humidity(-0.009). When conducting a scenario analysis on the areas with need for improvement in thermal environment, it was found that through reflectivity, color and the change in the physical properties of packing materials the thermal comfort felt by the body could be improved, and it is believed that through this the improvement plan can be established.

Evaluation of Indoor Thermal Environment and Thermal Sensation in Traditional Ondol Room (전통온돌방의 실내온열환경 및 온열감에 관한 연구)

  • 김난행;손장열
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.19-25
    • /
    • 2004
  • The aim of the research was to evaluate the characteristics of indoor thermal environment and thermal sensation in the traditional Ondol room. Indoor thermal factors including air temperature, operative temperature, floor surface temperature, relative humidity, PMV, OT were measured, and survey was carried out to understand subjective responses of resident's related to indoor thermal environment in Ondol room. The analysed houses are: the Chung hyo dang(the head house of Ryu family in Andong) and the Pyeung won jung(the traditional house in Yesan). The purpose of the survey was to know the relationship between resident's sensation and thermal environmental indicators such as air temperature, relative humidity, floor surface temperature, OT. The experimental results have pointed out how Ondol room may lead to comfortable and uniform indoor thermal environments.

Research on the Performance of a Solar Air Conditioning System using a Liquid Desiccant in Summer (액체흡수제 이용 태양열 공조시스템의 하계 능력에 관한 연구)

  • Choi, K.H.;Yoon, J.I.;Kim, B.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.33-38
    • /
    • 2002
  • In order to find out whether solar air conditioning system could be applied to building or not, the performance and evaluation on thermal environment of the system suggested was done during summer. A solar model house was constructed to find out the performance and thermal environment evaluation when it actually operated outside. As a result, regeneration rate increased rapidly when LiCl solution temperature was over $50^{\circ}C$ and the regeneration rate was $13\sim15kg$ during 9 hours operation. Furthermore the dehumidification rate was 12kg at maximum during 10 hours operating of a dehumidifier and indoor temperature and relative humidity was $28.4^{\circ}C$ and 39.1% in average respectively. On evaluation of thermal environment during summer, PMV value was slightly high, but thermal sensation vote was 71% within the comfort zone.

Evaluation of Thermal Stratification and Primary Water Environment Effects on Fatigue Life of Austenitic Piping (열성층 및 냉각재 환경이 오스테나이트 배관의 피로수명에 미치는 영향 평가)

  • Choi, Shin-Beom;Woo, Seung-Wan;Chang, Yoon-Suk;Choi, Jae-Boong;Kim, Young-Jin;Lee, Jin-Ho;Chung, Hae-Dong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.8
    • /
    • pp.660-667
    • /
    • 2008
  • During the last two decades, lots of efforts have been devoted to resolve thermal stratification phenomenon and primary water environment issues. While several effective methods were proposed especially in related to thermally stratified flow analyses and corrosive material resistance experiments, however, lack of details on specific stress and fatigue evaluation make it difficult to quantify structural behaviors. In the present work, effects of the thermal stratification and primary water are numerically examined from a structural integrity point of view. First, a representative austenitic nuclear piping is selected and its stress components at critical locations are calculated in use of four stratified temperature inputs and eight transient conditions. Subsequently, both metal and environmental fatigue usage factors of the piping are determined by manipulating the stress components in accordance with NUREG/CR-5704 as well as ASME B&PV Codes. Key findings from the fatigue evaluation with applicability of pipe and three-dimensional solid finite elements are fully discussed and a recommendation for realistic evaluation is suggested.

A Study on Characteristics of Indoor Thermal Environment and Comfort Evaluation in Summer and Winter (하계 및 동계 실내 온열 환경 특성과 쾌적성 평가에 대한 연구)

  • 고경태;박종일;김경훈
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.11a
    • /
    • pp.88-93
    • /
    • 1998
  • The purpose of this study was to examine theory about indoor thermal comfort-environment as well as to determine thermal sensation and physical responses for men in summer and winter indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart rate(Electrocardiogram, ECG), Electroencephalo gram(EEG) were examined. We found that comfort of people was achieved at SET*. 24.7$^{\circ}C$, -0.82${\alpha}$-wave) both in summer and in winter.

  • PDF

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • v.17 no.2
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.