• 제목/요약/키워드: Thermal Discharge

검색결과 631건 처리시간 0.031초

Analysis of characteristics of discharge in liquid

  • Kim, Ju-Sung;Min, Boo-Ki;Hong, Young-June;Kang, Seong-Oun;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.209.2-209.2
    • /
    • 2016
  • Up to now, Plasma applications are thought as a leading technology in industrial, chemical and even medical and biological field. Especially, Due to direct discharge in liquid with reaction in ambient solution, plasma in liquid is useful plasma technology. Such as electro-surgery, water purification, radical generation for synthesis. For using those plasma applications efficiently, plasma characteristics should be understood in advance. But discharge in liquid is not much well-known about its characteristics. And plasma discharge in solution is difficult to generate and analysis due to electrolysis, vaporization and radical generation. So, We make stable plasma discharge in solution(saline 0.9%) without input gas. We also analyze new type of plasma source in thermal and electrochemical view. And we check characteristics of plasma in liquid. For example, plasma density and radical density(OH) with optical emission, thermal energy with thermometer, electrical energy with oscilloscope and so on. And we try to explain the bubble and plasma formation with circuit analysis.

  • PDF

폼 분무 노즐 방사 분포 및 폼의 열적 특성 연구 (Thermal Characteristics of Foams and Discharge of Fire-Protection Foam Spray Nozzle)

  • 김홍식;김윤제
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.151-158
    • /
    • 2005
  • A characteristic of discharge for a foam spray nozzle with various parameters was investigated. The discharge patterns from a fire foam spray nozzle are important to evenly spray over a maximum possible floor area. Two parameters of a foam spray nozzle were chosen, and compared with those from the standard one. Also, in order to evaluate the performance of discharged foam agents used to protect structures from heat and fire damages, the thermal characteristics of fire-protection foams were experimentally investigated. A simple repeatable test for fire-protection foams subjected to fire radiation was developed. This test involves foam generation equipment, a fire source for heat generation, and data acquisition techniques. Results show that the bubble size of foam is increased by large inside diameter of orifice or closed air hole, but phenomenon of discharge angle and expansion ratio is opposite. For the case of the open air hole, liquid film of a circular cone discharges with formation, growth, split and fine grain. In case of the closed air hole, a pillar of foam solution discharges with that. Though the temperature gradient in the foam increases with increased foam expansion ratio. it is not change with increased intensity of heat flux.

알루미나 반응기에서의 이산화탄소의 무성방전 특성 (Silent Discharge Characteristics of $CO_2$ for Alumina Imbedded-Discharge Reacted)

  • 조문수;곽동주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.1061-1064
    • /
    • 2001
  • Deep Interests have been paid on the application of non-thermal plasma technique to solve the environmental pollution problems. $CO_2$, is one of the severe pollutants which cause the acid rain and global warming. In this study, in order to improve the conversion efficiency of $CO_2$, the streamer corona discharge plasma and barrier discharge plasma reactors were made, and the conversion characteristics of $CO_2$by the corona discharge plasma and some discharge characteristics of these discharge chambers are studied experimentally.

  • PDF

동해 울진 원전 온배수배출구 주변 해역에서의 대형저서동물 군집구조 (Community Structure of Macrobenthos around the Thermal Discharge Area of the Uljin Nuclear Power Plant in the East Sea, Korea)

  • 권순현;유옥환;이형곤
    • Ocean and Polar Research
    • /
    • 제39권2호
    • /
    • pp.125-148
    • /
    • 2017
  • This study analyzed the community structure of macrobenthic organisms in the subtidal area suffering under the influence of thermal discharge from the Uljin nuclear power plant during 2012-2013 and reviewed the temporal change in the faunal composition of the macrobenthic community using data from previous studies since the start of the plant operation in 1989. A total of 319 species were collected in 2012-2013, with a mean density of $3,330ind./m^2$ and a mean biomass of $131.96g/m^2$. These results were similar to those obtained in 2006-2007. The dominant species were not different from each other before and after the power plant operations began, but the faunal density near the power plant drainage port was significantly higher compared to those densities obtained from other stations. Spiophanes bombyx and Polydora sp., which is known as a pollution indicator species, was dominant only in the drainage port area. The study area consisted of two subregions with different macrobenthic communities depending on the water depth, which was similar to the results of the 2006-2007 survey. The macrobenthic community structures before and after the operation of the power plant in the coastal area were not changed, but there were seasonal differences in the long-term macrobenthic community structure which were strongly related to the thermal discharge from the power plant.

농어촌지역 미활용에너지의 부존량과 이용 가능량 분석 (A Study on Analysis of Reserves and Available Capacity of Unutilized Energy in Rural Community)

  • 박미란;류연수;김진욱;이용욱;배성돈;채갑병
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.19-25
    • /
    • 2014
  • Alternative sources of energy take a higher interest in order to reduce the greenhouse gas under the Climate Change Convention, fossil fuel consumption, and lower social anxiety about nuclear power such as crisis involving the Fukushima plant, problem of obsolete equipment. The energy consumption of agriculture, forestry and fisheries in South Korea is 3,082,000toe by 2011, reliance on electrical energy(35%) and oil(57.2%) is very high with 92.2%. In this study, we examined reserves and available capacity of temperature difference energy for thermal discharge from plant, treated sewage, river water, dam, and agricultural reservoir in rural community. Reserves of unutilized energy are 455,735Tcal/yr in rural community, these accounts for 78% of total reserves 582,385Tcal/y. Thermal discharge from plant has the most reserves of unutilized energy in rural community, it is estimated that it has the reserves of 277,410Tcal/y. Available capacity of unutilized energy in rural community is total 134,147Tcal/y, thermal discharge from plant available for heating is the most 128,035Tcal/y, and it shows in the order of treated sewage 4,318Tcal/y, river water 1,653Tcal/y, and reservoir 141Tcal/y. Elevating temperature area of green house by 2012 is 21,208ha. The amount of energy required for heating the greenhouse a year is dbout 11,365Tcal/y with 8.5% of the total available capacity of unutilized energy.

태양일사가 실내공간의 열적 쾌적성과 환기성능에 미치는 영향에 관한 연구 (The study on the effect of the solar radiation on thermal comfort and ventilation performance in room space)

  • 연성현;이효준;리광훈
    • 한국가시화정보학회지
    • /
    • 제14권1호
    • /
    • pp.19-26
    • /
    • 2016
  • Modern people spend much time at indoor space. So, People want to make better indoor air condition. But the facade of building is made of glass to be seen urbanely, the effect of solar radiation makes indoor environment worse. This study designs an open space affected by solar radiation with 4-way cassette air-conditioner. Using numerical simulation, this paper investigates thermal comfort and ventilation performance with discharge angles $30^{\circ}$ and $45^{\circ}$. To study thermal comfort, this paper studies distribution of velocity, temperature and effective draft temperature. Also, this paper introduces concept of air age to study ventilation performance. The flow influenced by solar radiation determines thermal comfort and ventilation performance in room space. This study shows that discharge angle of 45 degree has better thermal comfort and ventilation performance than that of 30 degree.

리튬이온 전지의 충방전 특성에 대한 전산 모델링 (Computational Modeling of Charge-Discharge Characteristics of Lithium-Ion Batteries)

  • 이대현;윤도영
    • 에너지공학
    • /
    • 제20권4호
    • /
    • pp.278-285
    • /
    • 2011
  • 본 연구에서는 리튬이온 전지의 충 방전 특성에 관한 모델링과 전산모사를 수행하였다. 전지의 시스템 구성은 단순화된 2차원 형태의 단일셀에 대하여 모델링하였고, 공학적 편미분방정식 풀이자인 FEMLAB을 이용하여 288 K와 318 K 범위내에서 충방전 특성에 대한 열적 모델링을 수행하였다. 모델링에 채택한 물성치 변수들에 대하여 온도특성을 고려하였으며, 이를 통하여 전지의 특징적인 충방전의 사이클 변화와 충방전 전하량의 변화를 체계적으로 전산모사하였다. 그 결과 충방전 속도에 상관없이 충방전의 주기가 온도가 낮아질수록 짧아짐을 정량적으로 해석할 수 있었다. 이에 부가하여 전지내에서 리튬이온의 물질전달 현상을 해석하여, 전지의 충방전 특성과의 상관관계를 고찰하였다.

Investigations of Accelerated Aged Polymeric Insulators Using Partial Discharge Signal Measurement and Analysis

  • Mekala, K.;Chandrasekar, S.;Ravindran, R. Samson
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.299-307
    • /
    • 2015
  • Reduction in pollution performance of polymeric insulators, aged due to water absorption stress and thermal stress, is a major threat to the reliable operation of power transmission and distribution system. Formation of partial discharges on the surface of wet polluted insulator plays a major role in determining the life time and pollution performance of outdoor polymeric insulators. However, reports on partial discharge characteristics of water absorption stress aged and thermal aged polymeric insulators are scanty. This paper discusses the pollution performance characteristics of accelerated aged polymeric insulators using the advanced ultra wide band PD signal measurement and analysis. Laboratory experiments on accelerated aged polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. PRPD pattern and Time-Frequency map analysis of PD signals were carried out. From the results, it can be speculated that PD analysis is a well suited technique to understand the pollution performance of aged polymeric insulators.

태양열 발전에서 태양열에너지 수송을 위한 고온 축열 물질의 열절달 특성 (Heat Transfer Characteristics of High Temperature molten salt storage for Solar Thermal Power Generation)

  • ;김기만;강용혁;한귀영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.190-193
    • /
    • 2008
  • The heat transfer characteristics of molten salt storage system for the solar thermal power generation were investigated. Temperature profiles and the heat transfer coefficients during the storage and discharge stage were obtained with the steam as the heat transfer fluid. Two kinds of inorganic salt were employed as the storage materials and coil type of heat exchanger were installed in both tanks to provide the heat transfer surfaces during the storage and discharge stage. The effects of steam flow rates, flow direction of steam in the storage tank and the initial temperature of storage and discharge tank on the heat transfer were tested.

  • PDF

평판형 유전체 장벽 방전 반응기에서 Acetonitrile의 분해 특성 (Decomposition of Acetonitrile by Planar Type Dielectric Barrier Discharge Reactor)

  • 송영훈;김관태;류삼곤;이해완
    • 한국군사과학기술학회지
    • /
    • 제5권3호
    • /
    • pp.105-112
    • /
    • 2002
  • A combined process of non-thermal plasma and catalytic techniques has been investigated to treat toxic gas compounds in air. The treated gas in the present study is $CH_3$CN that has been known to be a simulant of toxic chemical agent. A planar type dielectric barrier discharge(DBD) reactor has been used to generate non-thermal plasma that produces various chemically active species, O, N, OH, $O_3$, ion, electrons, etc. Several different types of adsorbents and catalysts, which are MS 5A, MS 13X, Pt/alumina, are packed into the plasma reactor, and have been tested to save power consumption and to treat by-products. Various aspects of the present techniques, which are decomposition efficiencies along with the power consumption, by-product analysis, reaction pathways modified by the adsorbents and catalysts, have been discussed in the present study.