Analysis on the Characteristics of Ventilation and Cooling for Greenhouses Constructed in Reclaimed Lands (간척지 온실의 환기 및 냉방 특성 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.26 no.3
    • /
    • pp.181-187
    • /
    • 2017
  • The purpose of this study was to provide basic data for development of environmental design technology for greenhouses constructed in reclaimed lands. The climatic conditions around seven major reclaimed land areas with a plan to install advanced horticultural complexes in Korea were analyzed. The characteristics of natural ventilation and temperature rise through the thermal environment measurement of the greenhouse in Saemangeum were analyzed. The part to be applied to the environmental design of the greenhouses in reclaimed lands were reviewed. Results of comparing the ventilation rate of the greenhouse according to the presence or absence of plants showed the greenhouse with plants had the lower ventilation rate, but the smaller rise of indoor temperature due to the evapotranspiration of plants. In the greenhouse with plants, the number of air changes was in the range of 0.3 to 0.9 volumes/min and the average was 0.7 volumes/min. The rise of indoor temperature relative to outdoor temperature was in the range of 1 to $5^{\circ}C$ and the average $2.5^{\circ}C$. The natural ventilation performance of the experimental greenhouse constructed in the reclaimed land almost satisfied the recommended ventilation rate in summer and the rise of indoor temperature relative to outdoor temperature did not deviate considerably from the cultivation environment of plants. Therefore, it was determined that the greenhouse cultivation in Saemangeum reclaimed land is possible with only natural ventilation systems without cooling facilities. As the reclaimed land is located in the seaside, the wind is stronger than the inland area, and the fog is frequent. This strong wind speed increases the ventilation rate of greenhouses, which is considered to be a factor for reducing the cooling load. In addition, since the fog duration is remarkably longer than that of inland area, the seasonal cooling load is expected to decrease, which is considered to be advantageous in terms of the operation cost of cooling facilities.

Estimation of Soil Cooling Load in the Root Zone of Greenhouses (온실내 근권부의 지중냉각부하 추정)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.151-156
    • /
    • 2002
  • Root zone cooling, such as soil or nutrient solution cooling, is less expensive than air cooling in the whole greenhouse and is effective in promoting root activity, improving water absorption rate, decreasing plant temperature, and reducing high temperature stress. The heat transfer of a soil cooling system in a plastic greenhouse was analyzed to estimate cooling loads. The thermal conductivity of soil, calculated by measured heat fluxes in the soil, showed the positive correlation with the soil water content. It ranged from 0.83 to 0.96 W.m$^{[-10]}$ .$^{\circ}C$$^{[-10]}$ at 19 to 36% of soil water contents. As the indoor solar radiation increased, the temperature difference between soil surface and indoor air linearly increased. At 300 to 800 W.m$^{-2}$ of indoor solar radiations, the soil surface temperature rose from 3.5 to 7.$0^{\circ}C$ in bare ground and 1.0 to 2.5$^{\circ}C$ under the canopy. Cooling loads in the root zone soil were estimated with solar radiation, soil water content, and temperature difference between air and soil. At 300 to 600 W.m$^{-2}$ of indoor solar radiations and 20 to 40% of soil water contents,46 to 59 W.m$^{-2}$ of soil cooling loads are required to maintain the temperature difference of 1$0^{\circ}C$ between indoor air and root zone soil.

Effect of Hypothermia on the Prevention of Ventilator-Induced Lung Injury in Rats (백서에서 저체온 전처치가 환기기유발폐손상 억제에 미치는 효과)

  • Lim, Chae-Man;Hong, Sang-Bum;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.5
    • /
    • pp.540-548
    • /
    • 2001
  • Backgrounds : Because ventilator-induced lung injury is partly dependent on the intensity of vascular flow, we hypothesized that hypothermia may attenuate the degree of such an injury through a reduced cardiac output. Methods : Twenty-seven male Sprague-Dawley rats were randomly assigned to normothermia ($37{\pm}1^{\circ}C$)-injurious ventilation (NT-V) group (n=10), hypothermia ($27{\pm}1^{\circ}C$)-injurious ventilation (HT-V) group (n=10), or nonventilated control group (n=7). The two thermal groups were subjected to injurious mechanical ventilation for 20 min with peak airway pressure 30 cm $H_2O$ at zero positive end-expiratory pressure, which was translated to tidal volume $54{\pm}6\;ml$ in the NT-V group and $53{\pm}4\;ml$ in the HT-V group (p>0.05). Results : Pressure-volume (P-V) curve after the injurious ventilation was almost identical to the baseline P-V curve in the HT-V group, whereas it was shifted rightward in the NT-V group. On gross inspection, the lungs of the HT-V group appeared smaller in size, and showed less hemorrhage especially at the dependent regions, than the lungs of the NT-V group. [Wet lung weight (g)/body weight (kg)] ($1.6{\pm}0.1$ vs $2.4{\pm}1.2$ ; p=0.014) and [wet lung weight/dry lung weight] ($5.0{\pm}0.1$ vs $6.1{\pm}0.8$ ; p=0.046) of the HT-V group were both lower than those of the NT-V group, while not different from those of the control group($1.4{\pm}0.4$, $4.8{\pm}0.4$, respectively). Protein concentration of the BAL fluid of the HT-V group was lower than that of the NT-V group($1,374{\pm}726\;ug/ml$ vs $3,471{\pm}1,985\;ug/ml$;p=0.003). Lactic dehydrogenase level of the BAL fluid of the HT-V group was lower than that of the NT-V group ($0.18{\pm}0.10\;unit/ml$ vs $0.43{\pm}0.22\;unit/ml$;p=0.046). Conclusions : Hypothermia attenuated pulmonary hemorrhage, permeability pulmonary edema, and alveolar cellular injuries associated with injurious mechanical ventilation, and preserved normal P-V characteristics of the lung in rats.

  • PDF

Mock-up Test of Temperature Crack Reduction Method Application by Setting Time Control of Mat Foundation Mass Concrete (응결시간조정에 의한 매트기초 매스 콘크리트의 온도균열저감 공법적용의 Mock-up Test)

  • Han, Cheon-Goo;Lee, Jae-Sam;Noh, Sang-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.55-61
    • /
    • 2009
  • Recently, the number of high-rise buildings being built in Korea by major construction companies for residential and commercial use has been increasing. When constructing a high-rise building, it is necessary to apply massive amounts of concrete to form a mat foundation that can withstand the huge load of the upper structure. However, it is of increasing concern that due to limitations in terms of the amount of placing equipment, available job-sites and systems for mass concrete placement in the construction field, it is not always possible to place a great quantity of concrete simultaneously in a large-scale mat foundation, and for this reason consistency between placement lift cannot be secured. In addition, a mat foundation Is likely to crack due to the stress caused by differences inhydration heat generation time. To derive a solution for these problems, this study provides test results of a hydration heat crack reduction method by applying placement lift change and setting time control with a super retarding agent for mass concrete in a large-scale mat foundation. Mock-up specimens with different mixtures and placement liftswere prepared at the job-site of a newly-constructed high-rise building. The test results show that slump flow of concrete before and after adding the super retarding agent somewhat Increases as the target retarding time gets longer, while the air content shows no great difference. The setting time was observed to be retarded as the target retarding time gets longer. As the target retarding time gets longer, compressive strength appears to be decreased at an early stage, but as time goes by, compressive strength gets higher, and the compressive strength at 28 days becomes equal or higher to that of plain concrete without a super retarding agent. For the effect of placement lift change and super retarding agent on the reduction of hydration heat, the application of 2 and 4 placement lifts and a super retarding agent makes it possible to secure consistency and reduce temperature difference between placement lifts, while also extending the time to reach peak temperature. This implies that the possibility of thermal crack induced by hydration heat is reduced. The best results are shown in the case of applying 4 placement lifts.

Infrared Thermography in the Assessment of Temporomandibular Joint Dysorder (측두하악장애에서의 적외선 체열 촬영 검사의 유용성)

  • Nahm, Sahngun Francis;Koo, Mi Suk;Kim, Yang Hyun;Suh, Jeong Hun;Shin, Hwa Yong;Choi, Yong Min;Kim, Yong Chul;Lee, Sang Chul;Lee, Pyung Bok
    • The Korean Journal of Pain
    • /
    • v.20 no.2
    • /
    • pp.163-168
    • /
    • 2007
  • Background: Temporomandibular joint disorder (TMD) is a group of musculoskeletal conditions characterized by pain in the pre-auricular area, limitation of jaw movement and palpable muscle tenderness. Thermography is a nonionizing, noninvasive diagnostic alternative for the evaluation of TMD. This study was conducted to evaluate the usefulness of thermography in the assessment of TMD. Methods: Thermography was conducted on the 61 patients who had been diagnosed with TMD, and on the 34 normal symptom-free volunteers. The temperature differences between opposite sides of the temporomandibular joint (${\Delta}T_{TMJ}$) and the masseter muscle (${\Delta}T_{MST}$) were calculated. The sensitivity and specificity of thermography was calculated at the cut off values of 0.2, 0.3, and $0.4^{\circ}C$. Results: In the patient group, the ${\Delta}T_{TMJ}$ was $0.42{\pm}0.38^{\circ}C$ and the ${\Delta}T_{MST}$ was $0.38{\pm}0.33^{\circ}C$, whereas in the control group the ${\Delta}T_{TMJ}$ was $0.10{\pm}0.07^{\circ}C$ and the ${\Delta}T_{MST}\;0.15{\pm}0.10^{\circ}C$. In addition, the patient group demonstrated a significantly lower level of thermal symmetry than the control group (P < 0.001) in both the temporomandibular joints and the masseter muscles. The sensitivity of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 67.2, 49.2, and 42.6% in the temporomandibular joint (TMJ) and 60.7, 49.2 and 37.7% in the masseter muscle, respectively. The specificity of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 88.2, 100, and 100% in the TMJ and 61.8, 91.2 and 100% in the masseter muscles, respectively. The accuracy of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 74.7, 67.4, and 63.2% in TMJ and 61.1, 64.2 and 60.0% in the masseter muscles, respectively. Conclusions: Temperature differences exist between the opposite sides of the TMD and masseter muscles in patients with TMD. Although the sensitivity of thermography in the diagnosis of TMD is low, it has high specificity in the evaluation of TMD, and is therefore applicable to patients with TMD.

A Study on the Effect of Applying Water Seepage Lowering Method Using Swelling Waterstop for Expansion Joint in the Concrete Dam (콘크리트 댐에서 수축이음부의 수팽창성 차수재를 이용한 침투저감 공법 적용효과 연구)

  • Han, Kiseung;Lee, Seungho;Kim, Sanghoon;Kim, Sejin;Pai, Sungjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.10
    • /
    • pp.21-29
    • /
    • 2021
  • Most concrete gravity-type dams in and out of the country were constructed by column method to control cracks caused by concrete hydration heat generated during construction, resulting in a certain level of leakage after impoundment through various causes, such as contraction joints and construction joints. However, due to the characteristics of concrete structures that shrink and expand according to temperature, concrete dams have vertical joints and drains to allow penetration. PVC waterproof shows excellent effects in completion of the dam, which however increases the possibility of interfacial failure due to different thermal expansion. Other causes of penetration may include problems with quality control during installation, generation of cracks due to heat of hydration of concrete, waterproofing methods, etc. In the case of Bohyunsan Dam in Yeongcheon, North Gyeongsang Province, the amount of drainage in the gallery was checked and underwater, and it was confirmed that there are many penetrations from drainage holes connected to vertical joints, and that some of the PVC waterproofs are not fully operated. As a new method to prevent penetration through vertical joints, D.S.I.M. (Dam Sealing Innovation Method) developed by World E&C was applied to Bohyunsan Dam and checked the amount of drainage in the gallery. As a result of first testing three most leaking vertical joints, the drain in the gallery was reduced by 87% on the average and then applied to the remaining 13 locations, which showed a 83% reduction effect based on the total drain in the gallery. Summing up these results, it was found that D.S.I.M. preventing water leakage from the upstream face is a valid construction method to reduce the water see-through and penetration quantity seen in downstream faces of concrete dams. If D.S.I.M. is applied to other concrete dams at domestic and abroad, it is expected that it will be very effective to prevent water leakage through vertical joints that are visible from downstream faces.

Study on Control of Thermal Environmental Factors for Improvement of Productivity of Laying Hens in Summer (여름철 산란계사 내 열환경인자 중 제어요소에 관한 연구)

  • Kim, Seong-Wan;Lee, Tae-Hoon;Cha, Gwang-Jun;Gutierrez, Winson M.;Chang, Hong-Hee
    • Journal of agriculture & life science
    • /
    • v.53 no.2
    • /
    • pp.121-129
    • /
    • 2019
  • This study carried out to determine control factors for the improvement of productivity of laying hens suffering heat stress during hot weather. A total of 48,451 ISA Brown layers were housed in a farm located in Gyeongsangnam-do, Republic of Korea. Five thermo-hydrometer loggers were installed inside the house to collect data of dry-bulb temperature and relative humidity. The experiment continued for 81 days when the summer season begins from 19th June to 7th September, 2018. This study analyzed the correlations among layers' production index and daily average, highest, and lowest temperature; daily average, highest, and lowest relative humidity; and daily average, minimum, and maximum THI. The result indicated that feed consumption, hen-day egg production, egg weight, and FCR decreased as the daily average, highest and lowest dry-bulb temperature and THI rise (p<0.01). On the other hand, water intake increased as the daily average, highest and lowest dry-bulb temperature and THI rise (p<0.001). The relative humidity was not considered to have direct correlations to the layers' production index (p>0.05). However, it was noticeable that the mortality did not have significant relations with daily average and highest temperature; THI; or daily average, highest and lowest relative humidity while it was relevant to the daily lowest temperature and THI (p<0.05). In conclusion, to enhance the productivity of laying hens in a hot climate, it is recommended that daily average, highest, and lowest dry-bulb temperature and THI are maintained as low as possible. Especially, the daily lowest temperature is needed to lower to 20℃, which is the lowest critical temperature for layers.

Characteristics of Cooling Effect Depending on Operation of Forced Ventilation Systems in a Single-span Plastic Greenhouse (강제환기장치 사용에 따른 단동 플라스틱 온실 기온 강하 특성)

  • Kim, Seong-Heon;Kim, Hyung-Kweon;Kwon, Jin-Kyung;Lee, Si-Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.143-151
    • /
    • 2022
  • This study was carried out to investigate quantitative characteristics of the cooling effect in a single-span arch greenhouse with roll-up side vents depending on operation of circulation and exhaust fans during ventilation, in order to suggest a practical strategy regarding installation or operation of forced ventilation systems. The examination was conducted under 3 different ventilation conditions (side vents only, side vents + circulation fans, and side vents + circulation fans + exhaust fans). In each condition, variations of internal and external air temperatures and exogenous environmental factors were recorded during ventilation, and the cooling effects were investigated by comparing the normalized temperature difference (NTD) of each ventilation condition. In the morning time (11:00-12:00), a temporary peak in the temperature difference was observed at the beginning of ventilation regardless of ventilation methods. The time taken to the maximum NTD was decreased from 340 s to 110s, and the NTD was dropped from 1.158 to 1.037 as the more forced ventilation systems were operated. The more operations caused the passing time over specific NTD values reduced by 60% as the time was reduced from 1,030 s to 550 s at NTD = 0.8, 1,610 s to 915 s at NTD = 0.6, and 2,315 s to 1,360 s at NTD = 0.4. The temporary peak in NTD was not observed in the afternoon time (14:00-15:00) but it was dropped as quickly as the ventilation started. Also the more operations resulted in the passing time over specific NTD values reduced by 70% as the time was reduced from 560 s to 345 s at NTD = 0.8, from 825 s to 540 s at NTD = 0.6, and from 1,145 s to 810 s at NTD = 0.4. Conclusively, the intervention of the forced ventilation system is recommended in the morning time or in high thermal conditions to achieve more effective and economical ventilation.

Studies on Garlic Mosaic Virus -lts isolation, symptom expression in test plants, physical properties, purification, serology and electron microscopy- (마늘 모자이크 바이러스에 관한 연구 -마늘 모자이크 바이러스의 분리, 검정식물상의 반응, 물리적성질, 순화, 혈청반응 및 전자현미경적관찰-)

  • La Yong-Joon
    • Korean journal of applied entomology
    • /
    • v.12 no.3
    • /
    • pp.93-107
    • /
    • 1973
  • Garlic (Allium sativum L.) is an important vegetable crop for the Korean people and has long been cultivated extensively in Korea. More recently it has gained importance as a source of certain pharmaceuticals. This additional use has also contributed to the increasing demand for Korean garlic. Garlic has been propagated vegetatively for a long time without control measures against virus diseases. As a result it is presumed that most of the garlic varieties in Korea may have degenerated. The production of virus-free plants offers the most feasible way to control the virus diseases of garlic. However, little is known about garlic viruses both domestically and in foreign countries. More basic information regarding garlic viruses is needed before a sound approach to the control of these diseases can be developed. Currently garlic mosaic disease is most prevalent in plantings throughout Korea and is considered to be the most important disease of garlic in Korea. Because of this importance, studies were initiated to isolate and characterize the garlic mosaic virus. Symptom expression in test plants, physical properties, purification, serological reaction and morphological characteristics of the garlic mosaic virus were determined. Results of these studies are summarized as follows. 1. Surveys made throughout the important garlic growing areas in Korea during 1970-1972 revealed that most of the garlic plants were heavily infected with mosaic disease. 2. A strain of garlic mosaic virus was obtained from infected garlic leaves and transmitted mechanically to Chenopodium amaranticolor by single lesion isolation technique. 3. The symptom expression of this garlic mosaic virus isolate was examined on 26 species of test plants. Among these, Chenopodium amaranticolor, C. quince, C. album and C. koreanse expressed chlorotic local lesions on inoculated leaves 11-12 days after mechanical inoculation with infective sap. The remaining 22 species showed no symptoms and no virus was recovered from them whet back-inoculated to C. amaranticolor. 4. Among the four species of Chtnopodium mentioned above, C. amaranticolor and C. quinoa appear to be the most suitable local lesion test plants for garlic mosaic virus. 5. Cloves and top·sets originating from mosaic infected garlic plants were $100\%$ infected with the same virus. Consequently the garlic mosaic virus is successively transmitted through infected cloves and top-sets. 6. Garlic mosaic virus was mechanically transmitted to C, amaranticolor when inoculations were made with infective sap of cloves and top-sets. 7. Physical properties of the garlic mosaic virus as determined by inoculation onto C. amaranticolor were as follows. Thermal inactivation point: $65-70^{\circ}C$, Dilution end poiut: $10^-2-10^-3$, Aging in vitro: 2 days. 8. Electron microscopic examination of the garlic mosaic virus revealed long rod shaped particles measuring 1200-1250mu. 9. Garlic mosaic virus was purified from leaf materials of C. amaranticolor by using two cycles of differential centrifugation followed by Sephadex gel filtration. 10. Garlic mosaic virus was successfully detected from infected garlic cloves and top-sets by a serological microprecipitin test. 11 Serological tests of 150 garlic cloves and 30 top-sets collected randomly from seperated plants throughout five different garlic growing regions in Korea revealed $100\%$ infection with garlic mosaic virus. Accordingly it is concluded that most of the garlic cloves and top-sets now being used for propagation in Korea are carriers of the garlic mosaic virus. 12. Serological studies revealed that the garlic mosaic virus is not related with potato viruses X, Y, S and M. 13. Because of the difficulty in securing mosaic virus-free garlic plants, direct inoculation with isolated virus to the garlic plants was not accomplished. Results of the present study, however, indicate that the virus isolate used here is the causal virus of the garlic mosaic disease in Korea.

  • PDF

Study on the Thermal Storage Characteristics of Phase Change Materials for Greenhouse Heating (온실보온(溫室保溫)을 위한 상변화(相變化) 물질(物質)의 축열특성연구(蓄熱特性硏究))

  • Song, Hyun-Kap;Ryou, Young-Sun;Kim, Young-Bok
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.65-78
    • /
    • 1993
  • An overdose of fossil fuel for greenhouse heating causes not only the high cost and low quality of agricultural products, but also the environmental pollution of farm village. To solve these problems it is desirable to maximize the solar energy utilization for the heating of greenhouse in winter season. In this study phase change materials were selected to store solar energy concentratively for heating the greenhouse and their characteristics of thermal energy storage were analyzed. The results were summarized as follows. The organic $C_{28}H_{58}$, and the inorganic $CH_3COONa{\cdot}3H_2O\;and\;Na_2SO_4{\cdot}10H_2O$ were selected as low temperature latent heat storage materials. The equation of critical radius was derived to define the generating mechanism of the maximum latent heat of phase change materials. The melting point of $C_{28}H_{58}$ was $62^{\circ}C$, and the latent heat was $50.0{\sim}52.0kcal/kg$. The specific heat of liquid and solid phase was $0.54{\sim}0.69kcal/kg^{\circ}C$ and $0.57{\sim}0.75kcal/kg^{\circ}C$ respectively. The melting point of $CH_3COONa{\cdot}3H_2O$ was $61{\sim}62^{\circ}C$, the latent heat was $64.9{\sim}65.8$ kcal/kg and the specific heat of liquid and solid phase was respectively $0.83kcal/kg^{\circ}C$ and $0.51{\sim}0.52kcal/kg^{\circ}C$. The melting point of $Na_2SO_4{\cdot}10H_2O$ was $30{\sim}30.9^{\circ}C$, the latent heat was 53.0 kcal/kg and the specific heat of liquid and solid phase was respectively $0.78{\sim}0.89kcal/kg^{\circ}C$ and $0.50{\sim}0.7kcal/kg^{\circ}C$ When the urea of 21.85% was added to control the melting point of $Na_2SO_4{\cdot}10H_2O$ and the phase change cycles were repeated from 0 to 600, the melting point was $16.7{\sim}16.0^{\circ}C$ and the latent heat was $36.0{\sim}28.0kcal/kg^{\circ}C$.