• Title/Summary/Keyword: Thermal Control

검색결과 3,086건 처리시간 0.045초

공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001-)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

동계 Plastic house내 고추(Capsicum annuum L.) 육묘시 온도와 광도가 생장에 미치는 영향 I. 다중피복 고추육묘 시설내의 온도 및 광환경 영향 (Effects of Temperature and Light Intensity on the Growth of Red Pepper(Capsicum annuum L.) in Plastic House During Winter. I. Fluctuations of Temperature and Light Environment in the Multilayered Plastic House Grown Red Pepper)

  • 정순주;이범선;권용웅
    • 생물환경조절학회지
    • /
    • 제3권2호
    • /
    • pp.106-118
    • /
    • 1994
  • 동계 무가온 다중피복 plastic house내 고추육묘의 생장에 영향을 미치는 온도, 광도 및 지온의 변화를 노지와 시설내 피복별로 조사 분석하여 고추의 적정 육묘생장 환경과 실제 무가온 다중피복 plastic house내의 환경요인과의 관련성을 파악코자 수행한 결과는 다음과 같다. 1. 12월 20일부터 2월 25일 까지 P. E.필름으로 4중피복된 턴널내에서도 최저온도는 대부분 5$^{\circ}C$를 보여 고추의 냉해온도에 대한 노출을 피할 수 없었고 이 기간에 최고온도는 대부분 33$^{\circ}C$를 보였으며 극값은 42$^{\circ}C$를 보여 다소간 환기의 필요도 인정되었다. 2. 피복이 증가할수록 온도 일교차가 크게 나타나 노지는 5-1$0^{\circ}C$를 보인 반면 피복내에는 16-38$^{\circ}C$의 일교차를 보였다. 3. 저온기에 다중피복에 의한 보온효과는 뚜렷하였으나 4중피복하에서도 12$^{\circ}C$이하의 온도출현이 많아서 고추 시설내 육묘시 냉해피해 가능성이 상존하며, 3$0^{\circ}C$이상의 고온출현회수도 200회 이상이었다. 4. 광도에 있어서도 피복이 증가할수록 광도는 감소하였고 온도증가는 크게 광의존성이었으며, 최저광도는 피복에 관계없이 고추의 광보상점 이하를 보여주었다. 5. 12월 20일부터 2월 중순까지 기온은 오전 10시 이후에야 고추의 생육한계온도인 10-12$^{\circ}C$이상이 되었고, 오후 4시 이후에는 기온은 12$^{\circ}C$이상이 되어도 광도가 급격히 낮아 고추유묘의 광합성 및 생장에 제한적일 것으로 사료되었다. 6. 시설내 최저지온은 동계 4중피복내에서도 1$0^{\circ}C$내외로서 고추생장에는 생리적 피해온도 범위에 속하였다. 7. 광주지방에 45년간 온도자료를 보면 노지 최저온도의 극값은 1월 5일에 -19.4$^{\circ}C$를 기록하였으며 대부분 장기자료로부터 얻은 평균에서 $\pm$5$^{\circ}C$의 편차를 보였다.

  • PDF

온실지붕 차광과 수막 수준에 따른 냉방효과 분석 (Analysis of Cooling Effect on the Plastic Film Cover of Greenhouse Module Depending on the Shade and Water Curtain)

  • 김영복;박중춘;이승규;김성태;나우정;허무룡;정성우
    • 생물환경조절학회지
    • /
    • 제15권4호
    • /
    • pp.306-316
    • /
    • 2006
  • 하절기 온실재배가 늘어나고 적극적인 온실냉방이 필요해짐에 따라 저비용의 냉방법 개발이 매우 중요해졌다. 경제적인 냉방법을 개발하기 위하여 차광율 수준과 물흘림의 상태가 냉각효과에 미치는 영향을 분석하고자 하였다. 실험분석을 위해 온실모형 모듈을 제작하여 차광율수준과 물흘림수준을 조합 변화시켜가며 경시별 측정을 수행하고 변수의 수준별로 비교분석하였다. 1. 외기건구온도가 상승하면 모듈실내온도도 상승하는 경향이며, 차광막이 있고 물흘림이 있으면 대체적으로 외기온보다는 낮고 물온도보다는 높은 수준을 나타내고 있다. 한편, 물흘림이 없는 경우에는 차광율의 수준간 건구온도변화가 크지 않은 것으로 나타나고 있다. 물흘림이 없이 차광막만 있는 경우 차광율의 수준이 35%에서 75V로 높아질수록 평균내부온도는 낮아졌지만 외부보다는 1.7$\sim$4$^{\circ}C$ 정도의 높은 온도를 나타내었다. 그러나 물흘림과 차광이 동시에 이루어지는 경우 전체적으로 외부온도보다 낮은 가운데 그 차이가 -0.2$\sim$-1.2$^{\circ}C$ 정도로 외기평균보다 낮게 나타났다. 그러나 물흘림 수준에 따라서는 차이가 나타나지 않았으며, 물흘림은 골고루 분포되도록 분무해 줄 필요가 있는 것으로 판단되었다. 공급되는 물의 온도는 실내온도에 영향을 주지 않는 것으로 나타났다. 2. 차광율수준이 높을 수록 모듈내 흑구온도는 낮게 나타났다. 그러나 차광막만 설치하여서는 외부의 복사광 차단에 의한 냉각효과를 기대하기 어려우며 차광막과 함께 물흘림을 병행해야 복사광 차단과 함께 복사 냉각효과를 함께 얻을 수 있다는 것을 알 수 있었다. 3. 물흘림이 있는 경우 표면온도는 수온이하이거나 수온보다 높더라도 1.2$^{\circ}C$ 이상을 넘지 않았으며, 차광수준이 높을수록 표면온도는 더 낮게 나타났다 그 이유는 물의 증발냉각에 의해 표면이 냉각되기 때문으로 분석되었다. 필름표면온도의 평균은 차광막의 수준에 관계없이 비교적 일정한 값을 나타내었으나 물흘림이 없는 경우 차광율의 수준이 놓을 수록 평균온도는 높게 나타났던 바 이는 차광에 의해 외부 복사광이 차광막에 흡수되었기 때문으로 판단되었다. 4. 상대습도는 건구온도가 증가함에 따라 비교적 직선적으로 하강하였으며, 이는 수분의 공급이 따로 이루어지지 않는 한 절대습도가 일정하기 때문에 건구온도가 상승하면 자연스럽게 하강하게 되는 것으로 판단되었다. 차광막이 있거나 물흘림이 있는 경우에는 외기건구온도의 영향에는 영향을 받지 않고 모듈내 건구온도에 따라 변하는 것으로 나타났다.

간척지 온실의 환기 및 냉방 특성 분석 (Analysis on the Characteristics of Ventilation and Cooling for Greenhouses Constructed in Reclaimed Lands)

  • 남상운;신현호
    • 생물환경조절학회지
    • /
    • 제26권3호
    • /
    • pp.181-187
    • /
    • 2017
  • 간척지 온실의 환경설계 기술 개발을 위한 기초자료 제공을 목적으로, 첨단 시설원예단지 설치 계획이 있는 국내 7개 대규모 간척지 주변의 기후조건을 분석하였으며, 새만금 간척지 내에 설치된 3연동 플라스틱 온실을 대상으로 하절기에 시설 내외의 열적 환경계측 실험을 통하여 자연환기 및 온도 상승 특성을 분석하고, 간척지 온실의 환경 설계에 적용해야 할 부분을 검토하였다. 작물의 유무에 따른 온실의 환기율을 비교한 결과, 작물이 있으면 온실의 환기율은 낮아지지만 작물의 증발산에 의해 실내기온 상승은 감소하는 것으로 나타났다. 작물이 있는 경우 온실의 환기회수는 대체로 0.3~0.9회/min의 범위에 있었고, 평균 0.7 회/min으로 나타났다. 실외기온 대비 실내기온 상승은 $1{\sim}5^{\circ}C$정도의 범위에 있었고, 평균 $2.5^{\circ}C$로 나타났다. 간척지에 설치된 실험온실의 자연환기 성능은 여름철 권장 환기율을 거의 만족시키고, 실외기온 대비 실내기온 상승도 작물재배 환경을 크게 벗어나지 않으므로 새만금 간척지에서는 냉방설비 없이 자연환기 만으로 온실의 작물 재배가 가능할 것으로 판단된다. 간척지는 해안에 위치하고 있어 내륙지역에 비하여 바람이 강하고, 안개가 자주 끼는 특성을 보이는 것으로 나타났다. 이와 같이 강한 풍속은 온실의 환기율을 증가시키므로 냉방부하의 감소요인으로 작용하게 될 것으로 판단된다. 또한 안개지속시간이 내륙지역에 비하여 현저하게 길기 때문에 기간냉방부하는 감소할 것으로 예상되며 이는 냉방설비의 운전경비 측면에서 유리할 것으로 판단된다. 또한 간척지 온실의 환기 및 냉방시스템 설계 시에는 주변의 기상관측소 자료를 그대로 이용하지 말고, 온실 설치 지역에서 실측한 기상자료 또는 현장 여건을 반영하여 보정된 기상자료를 사용하여 설계하도록 할 필요가 있다.

온실내 근권부의 지중냉각부하 추정 (Estimation of Soil Cooling Load in the Root Zone of Greenhouses)

  • 남상운
    • 생물환경조절학회지
    • /
    • 제11권4호
    • /
    • pp.151-156
    • /
    • 2002
  • 지중냉각이나 양액냉각과 같은 근권부 냉각은 뿌리의 활력 증진, 양수분 흡수력의 향상, 작물체온의 강하 및 고온스트레스의 감소 등에 효과가 있는 것으로 알려져 있으며, 또한 온실 전체를 냉방하는것 보다 경제적이다. 따라서 본 연구에서는 지중냉각시스템을 경제적인 고온극복 방법중의 하나로 생각하고, 기술을 체계화하기 위한 시도로 지중냉각시스템의 열전달 특성을 분석하여 냉각부하를 산정하기 위한 실험을 수행하였다. 지중열류 측정자료로부터 힘수비에 따른 토양의 열전도율을 분석하였으며, 함수비 19~36%의 범위에서 열전도율은 0.83~0.96W.m$^{-}$.$^{\circ}C$$^{-}$로 직선적인 증가를 보였다. 일사량, 지표온도 및 기온의 관측치로부터 일사량에 따른 지표온도 상승을 회귀분석한 결과 거의 직선적인 관계를 보였으며, 지표온도는 실내 수평면 일사량 300~800W.m$^{-2}$ 범위에서 작물이 없는 경우 3.5~7.$0^{\circ}C$,작물이 지표면을 거의 덮고 있는 경우 1.0~2.5$^{\circ}C$ 정도 기온보다 상승하는 것으로 나타났다. 실험자료를 이용하여 온실의 설계기온과 냉각설정 지온, 일사량 및 토양의 함수비에 따른 지중냉각시스템의 냉각부하를 구하였다. 실내일사량 300~600W.m$^{-2}$ , 토양함수비 20~40%의 범위에서 기온과 지온의 차이를 1$0^{\circ}C$로 유지하기 위해서는 46~59W.m$^{-2}$ 의 냉각열량이 필요한 것으로 나타났다. 보다 정확한 설계자료의 구축을 위해서는 다양한 조건별 실험을 추가로 수행해야 할 것으로 생각된다.EX>$\mu$$_{r}$′) and the dielectric loss ($\varepsilon$$_{r}$"/$\varepsilon$$_{r}$′) were increased. It was caused that the absorption characteristics of the absorber were improved. The conduction loss and magnetic loss were expected to be occurred together because two matching frequencies were shown with carbon addition. It was confirmed that the matching frequency of the microwave absorber could be controlled by controlling heat-treatment temperatures and carbon additions.ons.tions.加的)으로 되거나 과가황(過加黃)이 될 우려가 있는 제조공정(製造工程)에서는 흔히들 이 방법(方法)을 무시(無視)하고 있다. 여기서 강조(强調)해 두어야 할 것은 항상 제품(製品)의 외부(外部)를 완전(完全)히 가황(加黃)시킬 필요(必要)는 없다는 것이다. 다공성(多孔性)이나 기포생성(氣泡生成)을 조장(助長)하는 불량가황상태(不良加黃狀態)와 표면(表面)에서의 과가황상태간(過加黃狀態間)의 균형(均衡)을 취(取)해 줘야 하는데 물론(勿論) 이때는 가황시간(加黃時間)을 단축(短縮)시켜야 한다는 경제적(經濟的)인 측면(側面)도 아울러 고려(考慮)해야 한다. 이것은 고무기술자(技術者)가 당면(當面)해야할 과제(課題)

백서에서 저체온 전처치가 환기기유발폐손상 억제에 미치는 효과 (Effect of Hypothermia on the Prevention of Ventilator-Induced Lung Injury in Rats)

  • 임채만;홍상범;고윤석;심태선;이상도;김우성;김동순;김원동
    • Tuberculosis and Respiratory Diseases
    • /
    • 제50권5호
    • /
    • pp.540-548
    • /
    • 2001
  • Backgrounds : Because ventilator-induced lung injury is partly dependent on the intensity of vascular flow, we hypothesized that hypothermia may attenuate the degree of such an injury through a reduced cardiac output. Methods : Twenty-seven male Sprague-Dawley rats were randomly assigned to normothermia ($37{\pm}1^{\circ}C$)-injurious ventilation (NT-V) group (n=10), hypothermia ($27{\pm}1^{\circ}C$)-injurious ventilation (HT-V) group (n=10), or nonventilated control group (n=7). The two thermal groups were subjected to injurious mechanical ventilation for 20 min with peak airway pressure 30 cm $H_2O$ at zero positive end-expiratory pressure, which was translated to tidal volume $54{\pm}6\;ml$ in the NT-V group and $53{\pm}4\;ml$ in the HT-V group (p>0.05). Results : Pressure-volume (P-V) curve after the injurious ventilation was almost identical to the baseline P-V curve in the HT-V group, whereas it was shifted rightward in the NT-V group. On gross inspection, the lungs of the HT-V group appeared smaller in size, and showed less hemorrhage especially at the dependent regions, than the lungs of the NT-V group. [Wet lung weight (g)/body weight (kg)] ($1.6{\pm}0.1$ vs $2.4{\pm}1.2$ ; p=0.014) and [wet lung weight/dry lung weight] ($5.0{\pm}0.1$ vs $6.1{\pm}0.8$ ; p=0.046) of the HT-V group were both lower than those of the NT-V group, while not different from those of the control group($1.4{\pm}0.4$, $4.8{\pm}0.4$, respectively). Protein concentration of the BAL fluid of the HT-V group was lower than that of the NT-V group($1,374{\pm}726\;ug/ml$ vs $3,471{\pm}1,985\;ug/ml$;p=0.003). Lactic dehydrogenase level of the BAL fluid of the HT-V group was lower than that of the NT-V group ($0.18{\pm}0.10\;unit/ml$ vs $0.43{\pm}0.22\;unit/ml$;p=0.046). Conclusions : Hypothermia attenuated pulmonary hemorrhage, permeability pulmonary edema, and alveolar cellular injuries associated with injurious mechanical ventilation, and preserved normal P-V characteristics of the lung in rats.

  • PDF

응결시간조정에 의한 매트기초 매스 콘크리트의 온도균열저감 공법적용의 Mock-up Test (Mock-up Test of Temperature Crack Reduction Method Application by Setting Time Control of Mat Foundation Mass Concrete)

  • 한천구;이재삼;노상균
    • 한국건축시공학회지
    • /
    • 제9권4호
    • /
    • pp.55-61
    • /
    • 2009
  • 현재 국내의 건설공사현장에서는 도심부에 대형 건설사를 중심으로 초고층 건축물의 시공이 진행 중에 있다. 그런데 이러한 초고층 건축물의 기초는 상부의 큰 하중을 지지하기 위해 매우 두꺼운 매트 콘크리트가 필수적이다. 그러나 이와 같은 매스 콘크리트는 현장여건상 다량의 콘크리트를 동시에 타설할 수 없기 때문에 일체성에 의문이 제기되는 것은 물론이고 수화발열시간의 서로 다름에 따른 내응력에 의한 균열발생 가능성이 증가한다. 따라서 본 연구에서는 상기의 문제점을 해소시키고자 국내 모처에 건설되고 있는 초고층 건축물을 대상으로 초지연제의 응결시간차를 활용한 수평분할타설 건축 매스 콘크리트의 수화열 조정공법을 실제 건축현장에 적용하고자 Mock-up test를 통하여 그 효율성을 확인하였다. 실험결과 초지연제 투입 전 후슬럼프 플로우는 목표 지연시간이 길어질수록 다소 증가하였고, 공기량은 큰 차이는 없는 것으로 나타났으며, 응결시간은 목표 지연시간이 길어질수록 지연되었다. 목표 지연시간이 길어질수록 초기재령에서는 압축강도가 작게 나타났으나, 재령이 경과할수록 강도증진 폭이 크게 되어 재령 28일에서는 보통 콘크리트보다 동등 혹은 그 이상을 나타내었다. 또한 2단 및 4단으로 초지연제에 의한 응결시간차공법을 활용한 경우 하부와 상부간 콘크리트의 일체화 및 온도차를 낮추고, 수화열 피크시점이 후기로 늦어짐에 따라 균열발생가능성을 저하시키는 효과를 확인할 수 있었는데, 특히 4단 타설에서 가장 양호한 효과가 나타남을 확인할 수 있었다.

측두하악장애에서의 적외선 체열 촬영 검사의 유용성 (Infrared Thermography in the Assessment of Temporomandibular Joint Dysorder)

  • 남상건;구미숙;김양현;서정훈;신화용;최용민;김용철;이상철;이평복
    • The Korean Journal of Pain
    • /
    • 제20권2호
    • /
    • pp.163-168
    • /
    • 2007
  • Background: Temporomandibular joint disorder (TMD) is a group of musculoskeletal conditions characterized by pain in the pre-auricular area, limitation of jaw movement and palpable muscle tenderness. Thermography is a nonionizing, noninvasive diagnostic alternative for the evaluation of TMD. This study was conducted to evaluate the usefulness of thermography in the assessment of TMD. Methods: Thermography was conducted on the 61 patients who had been diagnosed with TMD, and on the 34 normal symptom-free volunteers. The temperature differences between opposite sides of the temporomandibular joint (${\Delta}T_{TMJ}$) and the masseter muscle (${\Delta}T_{MST}$) were calculated. The sensitivity and specificity of thermography was calculated at the cut off values of 0.2, 0.3, and $0.4^{\circ}C$. Results: In the patient group, the ${\Delta}T_{TMJ}$ was $0.42{\pm}0.38^{\circ}C$ and the ${\Delta}T_{MST}$ was $0.38{\pm}0.33^{\circ}C$, whereas in the control group the ${\Delta}T_{TMJ}$ was $0.10{\pm}0.07^{\circ}C$ and the ${\Delta}T_{MST}\;0.15{\pm}0.10^{\circ}C$. In addition, the patient group demonstrated a significantly lower level of thermal symmetry than the control group (P < 0.001) in both the temporomandibular joints and the masseter muscles. The sensitivity of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 67.2, 49.2, and 42.6% in the temporomandibular joint (TMJ) and 60.7, 49.2 and 37.7% in the masseter muscle, respectively. The specificity of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 88.2, 100, and 100% in the TMJ and 61.8, 91.2 and 100% in the masseter muscles, respectively. The accuracy of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 74.7, 67.4, and 63.2% in TMJ and 61.1, 64.2 and 60.0% in the masseter muscles, respectively. Conclusions: Temperature differences exist between the opposite sides of the TMD and masseter muscles in patients with TMD. Although the sensitivity of thermography in the diagnosis of TMD is low, it has high specificity in the evaluation of TMD, and is therefore applicable to patients with TMD.

콘크리트 댐에서 수축이음부의 수팽창성 차수재를 이용한 침투저감 공법 적용효과 연구 (A Study on the Effect of Applying Water Seepage Lowering Method Using Swelling Waterstop for Expansion Joint in the Concrete Dam)

  • 한기승;이승호;김상훈;김세진;배성진
    • 한국지반환경공학회 논문집
    • /
    • 제22권10호
    • /
    • pp.21-29
    • /
    • 2021
  • 국내외 대부분의 콘크리트 중력식 댐은 시공 시 발생하는 콘크리트 수화열로 인한 균열을 제어하기 위해 분할타설을 시행하고 있다. 이로 인해 댐 규모와 관계없이 수축이음부, 시공이음 부에서 담수 후 일정 수준의 침투가 발생하고 있다. 설계에서는 신죽 및 시공 이음부 누수를 고려하여 배수처리를 반영하고 있는 실정이다. 또한 온도에 따라 수축팽창하는 콘크리트 구조물의 특성상 동절기에는 수직이음부 확대가 불가피하다. 이에 대한 대비책으로 수직이음부 내에 2열 PVC 지수판과, 침투를 흘려보낼 수 있는 배수공을 일반적으로 설치하고 있다. PVC 지수판의 경우 댐 준공 초기에는 우수한 효과를 발휘한다. 그러나 콘크리트 댐체와의 열팽창 계수가 다르기 때문에 해를 거듭할수록 수축팽창에 따른 계면 탈락 현상이 발생하고 있다. 이로 인해 차수효과가 떨어져 댐체 하류면까지 흘러가는 침투가 발생할 가능성이 크다. 이 외 침투의 원인으로는 타설 시의 품질관리에 관한 문제, 콘크리트 수화열에 의한 균열발생, 방수 공법 및 재료의 문제점 등이 있을 수 있다. 따라서 콘크리트 댐에서의 침투를 방지하기 위해 수직이음부에서 수팽창성 차수재를 이용한 보강공법(D.S.I.M.)을 개발하였다. 수팽창성 차수재를 이용한 침투저감 공법에 대한 적용효과를 확인하기 위해 경북 영천시에 있는 보현산댐에서 현장 적용성을 검토하였다. 현장조사결과 갤러리 내 배수량을 체크 및 수중 약액 조사를 실시한 결과 수직이음부에 연결된 배수공에서 침투가 많이 발생하는 것으로 확인되었다. 이는 일부 지수판의 역할이 완벽히 이루어지고 있지 않음을 확인할 수 있었다. D.S.I.M.을 적용한 후 갤러리 내 배수량을 확인하였다. 침투가 많은 수직이음부 3개소에 먼저 시험시공을 한 결과 해당부위의 갤러리 내 배수량이 약 87% 저감된 것을 확인하였다. 나머지 13개소의 수직이음부에 적용한 결과 총 갤러리 내 총 배수량 기준으로 83%의 저감효과를 확인할 수 있었다. 이러한 결과를 종합해 볼 때 콘크리트 댐의 하류면에서 보이는 물비침 및 침투수량을 저감하기 위해서는 상류면에서 수직이음부에서 침투를 방지하는 D.S.I.M.이 유효한 공법임을 확인할 수 있었다. 국내외 타 콘크리트 댐의 경우에도 D.S.I.M.을 적용한다면 하류면에서 육안으로도 보이는 수직이음부를 통한 침투에 대한 보수효과를 기대할 수 있을 것으로 예상된다.

여름철 산란계사 내 열환경인자 중 제어요소에 관한 연구 (Study on Control of Thermal Environmental Factors for Improvement of Productivity of Laying Hens in Summer)

  • 김성완;이태훈;차광준;;장홍희
    • 농업생명과학연구
    • /
    • 제53권2호
    • /
    • pp.121-129
    • /
    • 2019
  • 본 연구는 여름철 산란계의 더위 스트레스로 인한 생산성 저하에 영향을 미치는 열환경인자들 중 제어 요소를 결정하고 산란계의 생산성을 높일 수 있는 방안을 모색하기 위해 수행되었다. 경상남도에 위치한 산란계사에서 ISA Brown 품종의 산란계 48,451수를 공시하여 생산성 지표를 측정하였다. 또한 산란계사 내부에 온습도로거를 설치하여 건구온도와 상대습도를 여름이 시작되는 6월 19일부터 9월 7일까지 총 81일간 동안 측정하였다. 1일 평균온도, 1일 최고온도, 1일 최저온도, 1일 평균상대습도, 1일 최고상대습도, 1일 최저상대습도, 1일 평균THI, 1일 최고THI 그리고 1일 최저THI와 산란계의 생산성 지표 간의 상관관계를 분석하였다. 분석한 결과에 의하면, 1일 평균, 최고, 최저의 건구온도와 THI가 상승할수록 사료섭취량, 헨데이 산란율, 난중과 FCR은 낮아졌다(p<0.01). 반면, 음수량은 1일 평균, 최고, 최저의 건구온도와 THI가 상승할수록 증가하였다(p<0.001). 상대습도의 경우, 산란계의 생산성 지표에 대해 직접적인 상관관계를 가지지 않는 것으로 판단된다(p>0.05). 특이점으로는 폐사율의 경우, 1일 평균·최고 온도, THI와 1일 평균·최고·최저 상대습도와는 유의적인 상관관계를 가지지 않았지만, 1일 최저의 온도와 THI와는 상관관계를 갖는 것으로 분석되었다(p<0.05). 따라서, 여름철 산란계의 생산성을 향상시키기 위해서는 산란계사 내의 1일 평균, 최고, 최저의 건구온도와 THI를 가능한 낮추는 것이 필요하고, 특히 1일 최저온도를 산란계의 하한임계온도인 20℃에 근접하게 조성해주는 것이 유리할 것으로 판단된다.