• 제목/요약/키워드: Therm 6.1

검색결과 9건 처리시간 0.026초

Double Vent 창호 시스템의 단열성능평가 (The Evaluation of Thermal Performance of Double Vent Window System)

  • 유승호;박진우;문현준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.557-560
    • /
    • 2008
  • Window system is an essential component for ventilation, lighting, and thermal environment in buildings. However, window system has the lowest insulation performance and may cause high energy consumptions, if it is not properly designed. Thus, performance of window systems play an important role in built environment. This study proposes a new window systems for balcony, which has double vents and analyses the thermal performance using an intergrated simulation method with Therm 6.1 and Widow 6.1. The result shows higher U-factor than conventional window systems. It is expected that the double vent window system can increase thermal performance and save energy in apartment houses.

  • PDF

급액속도가 원심식 박막증발기의 운전 특성에 미치는 영향 (Effect of Feeding Rate for Operation Properties of Centrifugal Thin Film Evaporator)

  • 김병삼;박노현;박무현;한봉호
    • 한국식품과학회지
    • /
    • 제23권4호
    • /
    • pp.437-441
    • /
    • 1991
  • 원심식 박막증발기를 이용해 마늘착즙을 증발 농축하면서 급액속도가 증발표면에서의 액의 흐름상태와 운전 특성에 미치는 영향에 대해서 조사하였다. 급액속도 $25{\sim}125kg/h$의 운전 조건하에서 증발표면에서의 이론적인 박막의 두께는 $0.52{\sim}0.89mm$ 그리고 체류시간은 $1.77{\sim}6.75$초로 계산되었다. 한편 Reynolds number로 판단해 볼 때 증발표면에서의 마늘착즙의 흐름은 대체로 층류로 여겨졌다. 일정한 증기 및 증발온도 조건하에서 농축비는 급액속도가 증가함에 따라 감소한 반면 증발속도와 총괄열전달계수는 어느 일정한 값까지 증가하다가 감소하는 경향을 나타내었다. 그리고 급액속도 $25{\sim}125kg/h$(증발온도 $40^{\circ}C$, 증기온도 $95{\sim}120^{\circ}C$, 급액의 초기농도 $32^{\circ}Brix$)에서 농축비는 $1.04{\sim}2.04$, 총괄열전달계수는 $3,074.33{\sim}17,614.70kJ/m^{2}{\cdot}h{\cdot}^{\circ}C$ 였다.

  • PDF

R-22를 사용한 용접형 판형 열교환기의 응축열전달 및 압력강하 특성에 관한 연구 (Study on Condensation Heat Transfer and Pressure Drop Characteristics of R-22 in Brazed Plate Heat Exchanger)

  • 전창덕;권오갑;이진호
    • 대한기계학회논문집B
    • /
    • 제25권2호
    • /
    • pp.171-179
    • /
    • 2001
  • Experimental study has been carried out on the characteristics of pressure drop and heat transfer of brazed plate heat exchangers using R-22. Data are presented for the following range of variables: the mass flux (40∼90kg/$m^2$s), chevron angle ($20^{\circ}$, $35^{\circ}$, $45^{\circ}$) and inlet pressure of the refrigerant (1.4 and 1.6MPa). For both subcooled and two-phase flow, as chevron angle increases, pressure drop and heat transfer coefficient decrease. Condensation heat transfer coefficient and pressure drop were compared with the previously proposed correlations. Among therm, Traviss correlation agreed with experimental results within -40%∼-84% for heat transfer coefficient and -59%∼62% for pressure drop.

Results of Intradiscal Pulsed Radiofrequency for Lumbar Discogenic Pain: Comparison with Intradiscal Electrothermal Therapy

  • Fukui, Sei;Nitta, Kazuhito;Iwashita, Narihito;Tomie, Hisashi;Nosaka, Shuichi;Rohof, Olav
    • The Korean Journal of Pain
    • /
    • 제25권3호
    • /
    • pp.155-160
    • /
    • 2012
  • Background: We have developed an intradiscal pulsed radiofrequency (Disc PRF) technique, using Diskit $II^{(R)}$ needles (NeuroTherm, Wilmington, MA, USA), as a minimally invasive treatment option for chronic discogenic low back pain (LBP). The purpose of this study was to compare the representative outcomes of Disc PRF and Intradiscal Electrothermal Therapy (IDET) in terms of pain relief and reduction of disability. Methods: Thirty-one patients with chronic discogenic LBP who underwent either Disc PRF (n = 15) or IDET (n = 16) were enrolled in the study. A Diskit $II^{(R)}$ needle (15-cm length, 20-gauge needle with a 20-mm active tip) was placed centrally in the disc. PRF was applied for 15 min at a setting of $5{\times}50$ ms/s and 60 V. The pain intensity score on a 0-10 numeric rating scale (NRS) and the Roland-Morris Disability Questionnaire (RMDQ) were assessed pretreatment and at 1, 3, and 6 months post-treatment. Results: The mean NRS was significantly improved from $7.2{\pm}0.6$ pretreatment to$2.5{\pm}0.9$ in the Disc PRF group, and from $7.5{\pm}1.0$ to $1.7{\pm}1.5$ in the IDET group, at the 6-month follow-up. The mean RMDQ also showed significant improvement in both the Disc PRF group and the IDET group at the 6-month follow-up. There were no significant differences in the pretreatment NRS and RMDQ scores between the groups. Conclusions: Disc PRF appears to be an alternative to IDET as a safe, minimally invasive treatment option for patients with chronic discogenic LBP.

다기능 복합 솔라윈도우 시스템의 에너지성능평가 (The Energy Performance Evaluation of Multi-purpose Solar Window System)

  • 조일식;김병수
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.10-15
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window System built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. The reference model of simulation was made up to analysis energy performance on Solar Window system. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

다기능 솔라윈도우의 열성능 연구 (The Study of Thermal Performance on Solar Window)

  • 조일식;김장회;양윤섭;김병수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in Heating/cooling performance analysis. The reference model of simulation was made up to analysis Heating/cooling performance on Solar Window. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

  • PDF

시뮬레이션에 의한 다기능 복합 솔라윈도우 시스템의 채광과 에너지성능평가 (The Daylight and Energy Performance Evaluation of Multi-purpose Solar Window System Using Simulaton Program)

  • 정열화;이순명
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.103-110
    • /
    • 2011
  • The aim of this study was to analysis the Heating/cooling performance and Daylighting performance of Solar Window System built in apartments. the solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system. The process of this study is as follows: 1)Solar Window system was designed through the investigation of previous paper and work. 2)The simulation program(Lightscape3.2) was used in daylighting performance analysis. the reference model of simulation was made up to analysis daylighting performance on Solar Window system. 3)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. the reference model of simulation was made up to analysis energy and daylighting performance on Solar Window system. 4)The Size of Simulation model for daylighting and heating/cooling energy analysis was $148.5m^2$ 5)The lighting performance analysis was carried out with various variants, such as the size and installed area of Solar Window system. 6)Energy performance simulation was carried out with various variants, such as Integrated U-value of Solar Window system according to its position, installed angle and insulation thickness. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down at the average of $4.1kWh/m^2$ or 4.2%.

실측 실험을 통한 단열문의 열성능 평가 (Thermal Performance Assessment of Insulated door by experiment.)

  • 장철용;김치훈;안병립;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.47-52
    • /
    • 2011
  • Currently, Exterior wall's U-value about building envelope is 0.36 W/$m^2K$(Central Region), but window's one is 2.1 W/$m^2K$ according to air gap of glazing, filling gas, coating and type of windows. The door"s one is 1.6~5.5 W/$m^2{\cdot}K$ depending on material and configuration of door. As such, energy loss per unit of door is considerably larger like windows. The door for the recognition was relatively low because energy loss through the door is relatively small compared to window area. In this paper, thermal performance was analyzed through simulation targeting the door which has thermal break that can improve the insulation performance and doesn't have one. As a results of simulations, case1 was calculated as the average of 1.63 w/m2k and case 2 was calculated as the average of 4.14 w/m2k. The thermal performance of door depends on the type and condition of insulations. As a results of final simulations, Case1 was calculated as 1.06 w/m2k and Case2 was calculated as 1.27 w/m2k. As a results of the experiments, thermal performance of case 1 was measured as 1.28 w/m2k. Error between experiments and simulations is considered problems encountered when creating the samples. The effect of door frame on the overall thermal performance is slight because it's a small proportion of the door frame.

철도정비부지 내 매립된 폐기물에 의해 중금속으로 오염된 토양의 인체위해성 평가 (Human Risk Assessment of Soil Contaminated with Heavy Metal by Waste Reclaimed in Railway Maintenance Site)

  • ;정민정;문세흠;박진규
    • 유기물자원화
    • /
    • 제27권3호
    • /
    • pp.63-74
    • /
    • 2019
  • 본 연구에서는 대규모 철도부지를 상업부지로 개발함에 따라 과거 부지 내부에 산업 폐기물 등이 부적절하게 처리되어 중금속 폐기물로 오염된 토양의 Cu, Pb, Zn, Ni 에 대한 인체 위해성 평가를 수행하였다. 위해성 평가는 토양의 복원 및 복원과정에서 필요한 고려요소를 도출하는데 주요한 과정이다. 본 연구에서는 위해성 평가를 위해 환경부 위해성평가지침을 준용하여 노출농도 결정, 노출량 산정, 발암 및 비발암 위해도를 결정하였다. 이를 통해 철도부지의 중금속 오염토양의 인체 위해성 평가 결과를 제시하였다. 노출농도 산정결과 토양내 중금속 함량은 621.3 Cu mg/kg, 2,824.5 Pb mg/kg, 1,559.1 Zn mg/kg, 45 Ni mg/kg이고, 독성금속별 인체 노출량 결과, 노출경로별로는 토양의 실외비산 > 토양섭취 > 토양 접촉 순으로 나타났으며, 오염물질별로는 Pb > Zn > Cu > Ni 순으로 나타났다. 발암위해도 평가 결과, USEPA에서 제시한 허용발암위해도(TCR > $10^{-6}$) 보다 높게 나타났으며, 독성위해도(비발암성) 평가 결과, HI 지수(HI< 1.0)도 성인 3.5, 어린이 4.85, Cu 1.94 ~ 2.16, Pb 1.37 ~ 2.90으로 나타났다. 따라서 대상부지의 중금속으로 오염된 토양의 복원관리가 필요할 것으로 판단된다.