• Title/Summary/Keyword: Therapeutic technique

Search Result 363, Processing Time 0.03 seconds

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

Postoperative Radiation Therapy in the Soft-tissue Sarcoma (연부 조직 육종의 수술 후 방사선 치료 결과)

  • Kim Yeon Shil;Jang Hong Seok;Yoon Sei Chul;Ryu Mi Ryeong;Kay Chul Seung;Chung Su Mi;Kim Hoon Kyo;Kang Yong Koo
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.485-495
    • /
    • 1998
  • Purpose : The major goal of the therapy in the soft tissue sarcoma is to control both local and distant tumor. However, the technique of obtaining local control has changed significantly over the past few decades from more aggressive surgery to combined therapy including conservative surgery and radiation and/or chemotherapy. We retrospectively analyzed the treatment results of the postoperative radiation therapy of soft tissue sarcoma and its prognostic factor. Materials and Methods : Between March 1983 and June 1994, 50 patients with soft tissue sarcoma were treated with surgery and postoperative radiation therapy at Kang-Nam St. Mary's hospital. Complete follow up was possible for all patients with median follow up duration 50 months (range 6-162 months). There were 28 male and 32 female patients. Their age ranged from 6 to 83 with a median of 44 years. Extremity (58$\%$) was the most frequent site of occurrence followed by trunk (20$\%$) and head and neck (12$\%$). Histologically malignant fibrous histiocytoma (23$\%$), liposarcoma (17$\%$), malignant schwannoma (12$\%$) constitute 52$\%$ of the patients. Daily radiation therapy designed to treat all areas at a risk for tumor spread upto dose of 4500-5000 cGy. A shrinking field technique was then used and total 55-65 Gy was delivered to tumor bed. Twenty-five patients (42$\%$) received chemotherapy with various regimen in the postoperative period. Results : Total 41 patients failed either with local recurrence or with distant metastasis. There were 29 patients (48$\%$) of local recurrence. Four patients (7$\%$) developed simultaneous local recurrence and distant metastasis and 8 patients (13$\%$) developed only distant metastasis. Local recurrence rate was rather higher than of other reported series. This study included patients of gross residual, recurrent cases after previous operation, trunk and head and neck Primary This feature is likely explanation for the decreased local control rate. Five of 29 Patients who failed only locally were salvaged by re-excision and/or re-irradiation and remained free of disease. Factors affecting local control include histologic type, grade, stage, extent of operation and surgical margin involvement, lymph node metastasis (p<0.05). All 21 patients who failed distantly are dead with progressive disease at the time of this report. Our overall survival results are similar to those of larger series. Actuarial 5 year overall survival and disease free survival were 60.4 $\%$, 30.6$\%$ respectively. Grade, stage (being close association with grade), residual disease (negative margin, microscopic, gross) were significant as a predictor of survival in our series (p<0.05). Conclusion : Combined surgery and postoperative radiation therapy obtained 5 year survival rate comparable to that of radical surgery.

  • PDF

The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer (열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가)

  • Je Young Wan;Na Keyung Su;Yoon IL Kyu;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2005
  • Purpose : To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Materials and Methods : Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and $116^{\circ}$. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. Result : The deviations of dose detected with TLD from tumor dose were CA $+\;6\%$, thigh $+\;8\%$, umbilicus $+\;4\%$, calf $-\;8\%$, vertex $-\;74.4\%$, deep axillae $-\;10.2\%$, anus and testis $-\;87\%$, sole $-\;86\%$ and nails shielded with 4mm lead $+4\%$. The deviations of dose detected with diode were $-4.5\%{\sim}+5\%$ at the patient center and $-1.1\%{\sim}+1\%$ at the speller. Conclusion : The deviation of total skin dose was $+\;8\%{\sim}-\;8\%$ and that deviation was within the acceptable range(${\pm}\;10\%$). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  • PDF

Dose Characteristics of Stereotactic Radiosurgery in High Energy Linear Accelerator Proton Beam (고에너지 선형가속기에 의한 입체방사선수술의 선량특성)

  • Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.137-145
    • /
    • 1992
  • Three-dimensional dose calculations based on CT images are fundamental to stereotactic radiosurgery for small intracranial tumor. In our stereotactic radiosurgery program, irradiations have been performed using the 6 MV photon beam of linear accelerator after stereotactic CT investigations of the target center through the beam's-eye view and the coordinates of BRW frame converted to that of radiosurgery. Also we can describe the tumor diameter and the shape in three dimensional configuration. Non-coplanar irradiation technique was developed that it consists of a combination of a moving field with a gantry angle of $140^{\circ}$, and a horizontal couch angle of $200^{\circ}C$ around the isocenter. In this radiosurgery technique, we provide the patient head setup in the base-ring holder and rotate around body axis. The total gantry moving range shows angle of 2520 degrees via two different types of gantry movement in a plane perpendicular to the axis of patient. The 3-D isodose curves overlapped to the tumor contours in screen and analytic dose profiles in calculation area were provided to calculate the thickness of $80\%$ of tumor center dose to $20\%$ of that. Furtheremore we provided the 3-D dose profiles in entire calculation plane. In this experiments, measured isodose curves in phantom irradiation have shown very similiar to that of computer generations.

  • PDF

Studies on Veterinary Acupuncture in Korea (한국 수의침술에 관한 조사연구)

  • Nam Tchi-Chou;Jo Choong-Ho;Choi Hee-In;Sung Jai-Ki;Kweon Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.9 no.1
    • /
    • pp.283-299
    • /
    • 1992
  • Since successive operations under the acupuncture analgesia have been reported In China 1971, veterinary acupuncture was brought to the attention over the world and then its research and clinical use have markedly developed. Veterinary acupuncture and moxibustion was originated in China and Korea, but the research activities on them were not very significantly advanced. In this study, status of veterinarians on veterinary acupuncture and moxibustion, acupunctures which has been practiced by civil acupuncturist, therapeutic effects of acupuncture for the animal diseases in the field, and effects of electric acupuncture on the lumen motility in ruminants, etc. were Investigated. One-fifty of veterinarians of private clinics in Korea was interested in acupuncture and moxibustion in veterinary medicine. A lot of veterinarians required the scientific, systemic technique and knowledge or acupuncture. Civil acupuncturists who have been practiced acupuncture and moxibustion were 20 persons, and most of them were very old. They used chiefly three edged needles which were made by themselves and utilized old traditional technique in which the acupoints were stimulated and bled. Treatment with acupuncture for the digestive, muscular locomotive and febrile diseases was very effective. Until nowadays, the research on veterinary acupuncture in Korea has not much progressed. However, the Korean Societh of Veterinary Acupuncture and Moxibustion was organized in 1990. Valuable development for acupuncture through the society are expected. Electroacupuncture regional analgesia on the combinations of Yao-Pang 1, 2 and 4 acupoints was very effective for abdominal operations in cattle. But a lot of experiences and studies on the acupuncture anesthesia were required for clinical use in the future. Therapeutic effects of about 80% were obtained from electroacupuncture on the combinations of Tian Ping-Bai Hui-Shi Zhang, and Guan Yuan Yu acupoints in cattle with luminal atony and tympany In the field. Electroacupuncture on the combination of Tian Ping-Bai Hui-Qi Men, and Tian Ping-Bai Bui-Wei Gen for the treatment of downer cow was not so effective. The effects of stimulation and bleeding from acupoint by three edged needle was excellent for febrile diseases. The luminal contractile movement was accentuated by electroacupuncture on Tian Ping-Bai Hui-Shi Zhang combination and Guan Yuan Yu acupoint. It was concluded that veterinary acupuncture and moxibustion should be utilized for veterinary practice, and the advanced scientific research and clinical experiences must be followed.

  • PDF

A Study on Dose Distribution using Virtual Wedge in Breast Cancer (유방암 환자에서 가상 쐐기모양 보상체의 선량분포 특성에 대한 연구)

  • Yun, Sang-Mo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.7-12
    • /
    • 2007
  • In the radiation therapy for breast cancer patients, wedge shaped compensators are essentially used to achieve appropriate dose distribution because of thickness difference according to breast shapes. Tangential Irradiation technique has usually been applied to radiation therapy for breast cancer patients treated with breast conservative surgery. When a primary beam is incident on wedge shaped compensators from medial direction In tangential irradiation technique, low energy scattered radiation is generated and gives additional dose to the breast surface. As a method to reduced additional dose to breast surface, the use of virtual wedge shaped compensator is possible. Eclipse radiation treatment planning (RTP) systems Installed at our institution have virtual wedge shaped compensator for radiation therapy treatment planning. The dose distributions of 15, 30, 45, 60 degree physical wedges and virtual wedges were measured and compared. Results showed that there was no significant differences In symmetry of $10{\times}10$ field among various wedge angles. When the transmission factor was compared, transmission factor Increased linearly as the wedge angle Increased. These results Indicates that the appilcation of virtual wedge in clinical use is appropriate.

  • PDF

An Analysis of Research Using the Rhythmic Auditory Stimulation Technique: A Comparison of Music Therapy and Physical Therapy Approaches (국내 리듬청각자극(RAS) 기법 활용 연구 분석: 음악치료와 물리치료 비교를 중심으로)

  • Lee, Jiyeon
    • Journal of Music and Human Behavior
    • /
    • v.17 no.1
    • /
    • pp.71-96
    • /
    • 2020
  • The purpose of this study was to identify research that included the rhythmic auditory stimulation (RAS) technique and to compare this body of research within the field of music therapy with that in physical therapy. Forty-five studies were identified that were published from January 1999 through November 2018, and these were analyzed in terms of intervention procedure, type of rhythmic cueing, and therapeutic basis described by the researcher. While research in both fields used rhythmic cueing as the primary therapeutic agent, differences were found in the area targeted by training and specific type of rhythmic cueing used. Research conducted in the field of music therapy focused primarily on gait function, while research in the field of physical therapy tended to address gait-related physical issues, such as balance, muscle strength, and proprioceptive sensation as well as gait. While all of the identified studies from the field of music therapy used music for cueing, a metronome was used more often for cueing in physical therapy research. In terms of description of theoretical basis, theory of entrainment was more sufficiently described in music therapy research. These results indicate that while music therapy research maximized the role of various elements of music in intervening in gait function, physical therapy research addressed gait in relation to other physical functions. Considering that both aspects are essential for gait training, this study supports the need for a multidisciplinary approach to neurological rehabilitation with RAS.

Dosimetric Characteristics of Multileaf Collimator-based Intensity-modulated Arc Therapy for Stereotactic Radiosurgery (방사선수술 시 다엽 콜리메이터를 기초로 한 IMAT의 선량분포)

  • Yun, Sang-Mo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.93-97
    • /
    • 2007
  • This study was designed to evaluate radiosurgery technique using multiple noncoplanar arc therapy with intensity modulated fine MLC shaped photon beam. The stereotactic radiosurgery was performed with 6-MV X-ray beams from a Clinac 21EX LINAC (Varian, Palo Alto, CA, USA) with a MLC-120, which features a full $40{\times}40cm$ field and is the first MLC for general use that offers 0.5 cm resolution for high precision treatment of small and irregular fields. We used a single isocenter and five gantry-couch combinations with a set of intensity modulated arc therapy. We investigated dosimetric characteristics of 2 cm sized spherical target volume with film (X-OMAT V2 film, Kodak Inc, Rochester NY, USA) dosimetry within $25{\times}25cm$ acrylic phantom. A simulated single isocentric treatment using inversely Planned 3D radiotherapy planning system demonstrated the ability to conform the dose distribution to an spherical target volume. The 80% dose level was adequate to encompass the target volume in frontal, sagittal, and transverse planes, and the region between the 40% and 80% isodose lines was $4.0{\sim}4.5mm$ and comparable to the dose distribution of the Boston Arcs. We expect that our radiosurgery technique could be a treatment option for irregular-shaped large intracranial target.

  • PDF

Comparison of the Immediate Effects of Two Types of Muscle Energy Techniques Applied to the Hamstring of Adults in Their Twenties With or Without Low Back Pain on the Pelvic Inclination and the Length of the Hamstring (요통 유무에 따른 20대 성인의 넙다리뒤근에 적용한 두 가지 근에너지 기법 종류에 따른 골반 경사각 및 넙다리뒤근 길이에 미치는 즉각적 효과 비교)

  • Hwang, Lee-kyeong;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.37-47
    • /
    • 2022
  • Background: Lower back pain (LBP) is a major cause of disability and a common musculoskeletal disorder encountered at some point in life. Dysfunction of the lumbar vertebrae has been associated with decreased flexibility of the hamstrings, which exhibited a strong positive correlation with LBP. Hamstring tension affects lumbar pelvic rhythm. We aimed to activate pelvic stability with compression by Active Therapeutic Movement (ATM), muscle energy technique (MET) was applied to increase the flexibility of the hamstring. Objects: In this study, we aimed to investigate the effects of MET with ATM and general MET were applied to the hamstring of adults, who were in their twenties with nor without LBP, on their pelvic inclination and the length of their hamstring. Methods: A total of 32 subjects were briefed about the purpose of this study and agreed to participate voluntarily. Before the experiment, all subjects were pre-examined, and they were divided into an LBP group and a no lower back pain group accordingly. Thereafter, all subjects participated in both in a crossover manner. After at least one week, they switched to another group and participated in the same experiment. Results: The study results revealed that both groups demonstrated significant results in the modified active knee extension test (p < 0.01) and the sit and reach test (p < 0.01) performed to assess the hamstring flexibility; an interaction (p < 0.05) was noted. Moreover, a more significant difference was observed between the MET with ATM and the general MET. Although significant results were obtained for the pelvic inclination (p < 0.01), interaction was not noted. Conclusion: Conclusively, in this study, when the MET with ATM was applied to the two groups, there was a significant difference compared to the general MET for hamstring flexibility, but it was confirmed that there was no significant difference for the pelvic inclination.

Dose Effect of Tissue Compensator for 6 MV X-Ray (두경부 방사선조사시 3차원조직보상체에 의한 피부선량)

  • Lee, Ho-Jun;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.147-153
    • /
    • 1992
  • It is ideal thing to compensate tissue deficit without skin contamination in curvatured irradiation field of high energy photon beam. The 3-dimensional compensating technique utilizing tissue equivalent materials to ensure an adequate dose distribution and skin sparing effect was described. This compensator was made of paraffin ($70\%$) and stearin wax ($30\%$) compound. The parameters for evaluation of the effect on skin dose in application of compensator were considered in the size of the field, the thickness of the compensator and the source-to-axis distance. The results are as follows; the skin doses were not changed even though application of the compensator, but depended on the field size and the source-to-axis distance, and the skin doses were only slightly changed within $1\%$ relative errors as increasing the thickness of the compensator in these experiments.

  • PDF