• Title/Summary/Keyword: The size of human body

Search Result 490, Processing Time 0.038 seconds

Spatial distribution of particulate matters in comparison with land-use and traffic volume in Seoul, Republic of Korea (서울시 토지이용과 교통량에 따른 미세먼지의 공간분포)

  • Jeong, Jong-Chul;Lee, Peter Sang-Hoon
    • Journal of Cadastre & Land InformatiX
    • /
    • v.48 no.1
    • /
    • pp.123-138
    • /
    • 2018
  • To sustainably monitor air pollution in Seoul, the number of Air Pollution Monitoring Station has been gradually increased by Korea's Ministry of Environment. Although particulate matters(PM), one of the pollutants measured at the stations, have an significant influence on human body, the concentration of PM in Korea came in second among 35 OECD member countries. In this study, using the data of PM concentration from the stations, distribution maps of PM10 and PM2.5 concentrations over Seoul were generated, and spatial factors potentially related to PM distribution were investigated. Based on a circumscribed hexagon about a circle in radius of 500 meters created as a basic unit, Seoul was sectionalized and PM concentration map was generated using the interpolation technique of 'inverse distance weighting'. The distributions of PM concentrations were investigated with commuting time by administrative district and the outcome was related with land-use type and volume of traffic. Results from this analysis indicated distribution pattern of PM10 concentration was different from that of PM2.5 by administrative district and time. The distribution of PM concentration was strongly related to not only the size of business and trafficked areas among the land-use type, but also the existence of urban green. Further analysis of the relationship between the PM concentration and detailed land-use and urban green maps can be helpful to identify spatial factors which have an impact on the PM concentration on the regional scale.

A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System (자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구)

  • So-min Lee;Han-yong Kim;Dong-hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.573-579
    • /
    • 2023
  • This study compares dose difference between the presence or absence of grid in Chest PA radiography using auto exposure control and compares image quality among presence, absence or virtual grid, and proposes a new clinically useful grid combination for chest radiography. The human body phantom was placed Chest PA position and the dosimeter was placed at T6. The same irradiation conditions and field size were applied. 30 images were obtained in the state in which grid was applied and in the state in which grid was not applied, and an additional 30 images in which the virtual grid was applied to the image without the grid were obtained. Radiation dose was presented to entrance surface dose. The image quality was analyzed by comparing the signal-to-noise and contrast-to-noise ratio. ESD decreased by 48% when the grid was not used, compared to when the grid was used. SNR and CNR increased by 32% and 30% compared to grid use when grid was not used, respectively. In the case of using the virtual grid, it increased by 18% and 16% respectively, compared to the case of using the grid. As a result of this study, it is believed that when using a virtual grid instead of a grid, the quality of the image can be maintained while reducing the patient dose.

Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography (흉부 전·후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향)

  • Kim, Jong-Seok;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.295-300
    • /
    • 2021
  • This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

Anti-obesity Effect of Rhizoma Atractylodis Herbal Acupuncture in High Fat Diet-induced Obese ICR Mouse (고지방 식이로 유도된 비만 생쥐에서 창출약침의 항비만 효과)

  • Youh, Eun-Joo;Seo, Byung-Kwan;Nam, Sang-Soo;Kang, Sung-Keel
    • Journal of Acupuncture Research
    • /
    • v.27 no.6
    • /
    • pp.31-42
    • /
    • 2010
  • Objectives : The aim of this study was to investigate the anti-obesity potential and mechanisms of action of Rhizoma Atractylodis(RA) herbal acupuncture in high fat diet- induced obese ICR mice. Methods : Sample solutions for herbal acupuncture were prepared from the Rhizoma Atractylodis water extract powder at concentration of 150mg/kg and 300mg/kg with distilled water. Five week-old ICR mice acclimatized to the laboratory environment for 1 week were allocated into four groups: regular diet group (RD), high fat diet group(HFD), groups fed HFD with 150mg/kg RA herbal acupuncture treatment (RAE 150) and with 300mg/kg RA herbal acupuncture treatment(RAE 300). Herbal acupuncture groups were injected with either 150mg/kg or 300mg/kg of Rhizoma Atractylodis(RA) subcutaneously onto both Sinsu($BL_{23}$) alternately on the same time everyday for 30days. Body weight, gross appearance of epididymal fat area, blood glucose, insulin, insulin resistance(HOMA-IR), non-esterified fatty acid, cholesterol, triglyceride, AST, ALT, histological analysis of white adipose tissue, gene expression responsible for adipocyte differentiation and AMPK activation were analyzed. Results : RA herbal acupuncture inhibited the development of weight gain, hyperglycemia, hyperinsulinemia, hyperlipidemia, increases of AST and ALT, and the enlargement of fat cell size induced by HFD. Also, RA herbal acupuncture inhibited the expression of PPAR-${\gamma}$, C/$EBP{\alpha}$, aP2, LPL, FAS, SCD-1 and enhanced the activation of AMP-activated protein kinase. Conclusions : The results of this study demonstrate that RA herbal acupuncture can exert the anti-obesity effect and it is partially mediated by activation of AMPK and inhibition of the gene expressions responsible for adipocyte differentiation. Further studies will be required to ascertain the nti-obesity effect and mechanisms of action of RA herbal acupuncture in animal models and human for aclinical application.

CPLD-based Controller for Bi-directional Communication in a Capsule Endoscope (캡슐형 무선 내시경의 양방향 통신을 위한 CPLD 기반의 제어기 설계 및 구현)

  • Lee Jyung Hyun;Moon Yeon Kwan;Park Hee Joon;Won Chul Ho;Lee Seung Ha;Choi Hyun Chul;Cho Jin Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.447-453
    • /
    • 2004
  • In the case of a capsule that can acquire and transmit images from the intestines, the size of the module and the battery capacity in the capsule are subject to restriction. The capsule must be swallowable and the battery must maintain the stable power during the capsule travels in the gastrointestinal tract. Therefore, it is important to control the endoscope using bi-directional wireless communication. In this study, encoder and decoder CPLD modules for bi-directional capsule endoscopes were designed and implemented. The designed controller for capsule endoscope can transmit the images of GI-track from inside to outside of the body and the capsules can be controlled by external controller simultaneously. The designed and implemented controller was verified by an in-vivo animal experiments. From these experiments, it was verified that the CPLD module for bi-directional capsule endoscope satisfied the design specifications.

Dispersion of Particle Pulse in Human Lung Airway (인체기관지내의 입자펄스 확산 실험)

  • 이진원;이동엽;추경호
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.511-518
    • /
    • 1998
  • In order to develop the aerosol bolus technique which is thought to be a potential tool for probing geometries or abnormalities of small airways, an experimental system of measuring fast time variations of particle concentration in the inhaled and exhaled breathing air was developed. The system generates monodisperse sebacic acrid particles of 1 micron size and 1.2 of geometric standard deviation in high concentration of $10^8$ particles/cc, delivers a short pulse of particles at the controlled instant during inhalation using a solenoid valve, and measures the fast change of particle concentration in using the laser light scattering. Successful operation of the generator and the measuring system was confirmed by smooth concentration profiles in inhalation. It was also confirmed that maintaining a constant breathing rate is essential to stable outputs and any disturbance in flow rate near the mode (maximum concentration) induces a large number of spurious peaks in the exhalation. Experimental data without strict control of breathing flow rate showed a substantial amount of scatter. The measured results showed an improvement in scatter over the existing results. When compared with theoretical predictions from 1-D convective diffusion equation and other experiments, general characteristics of dispersion for several penetration depths showed a good agreement, but there exists some difference in absolute values, which is attributed to the difference in body conditions. Improvements are needed in the theory, especially in relation to correcting for the effect of breathing flow rate.

  • PDF

Motility Analysis of Gate Myocardium SPECT Image Using Left Ventricle Myocardium Model (좌심실 심근 모델을 이용한 게이트 심근 SPECT 영상의 운동성 분석)

  • 손병환;김재영;이병일;이동수;최흥국
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.3
    • /
    • pp.444-454
    • /
    • 2003
  • An analysis of heart movement is to estimate a role which supplies blood in human body. We have constructed a left ventricle myocardium model and mathematically evaluated the motion of myocardium. The myocardial motility was visualized using some parameters about cardiac motion. We applied the myocardium model in the gated myocardium SPECT image that showed a cardiac biochemical reaction, and analyzed a motility between the gated myocardium SPECT image and the myocardium model. The myocardium model was created of the based on three dimensional super-ellipsoidal model that was using the sinusoidal function. To express a similar form and motion of the left ventricle myocardium, we calculated parameter functions that gave the changing of motion and form. The LSF algorithm was applied to the myocardium gated SPECT image data and the myocardium model, and finally created a fitting model. Then we analyzed a regional motility direction and size of the gated myocardium SPECT image that was constructed on a fitting model. Furthermore, we implemented the Bull's Eye map that had evaluated the heart function for presentation of regional motility. Using myocardium's motion the evaluation of cardiac function of SPECT was estimated by a contraction ability, perfusion etc. However, it is not any estimation about motility. So, We analyzed the myocardium SPECT's motility of utilizing the myocardium model. We expect that the proposed algorithm should be a useful guideline in the heart functional estimation.

  • PDF

A study on the characteristics of fuel performance according to the oxygenated additive type for gasoline fuel Part 2. Exhaust and Non-regulated, PM emission characteristics (휘발유 연료용 함산소 첨가제 종류에 따른 성능 특성 연구 Part 2. 배출가스 및 미규제 물질, 입자상 물질 특성)

  • Lee, Min-Ho;Kim, Ki-Ho;Ha, Jong-Han
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.374-384
    • /
    • 2016
  • Concern about air pollution is gradually rising up in domestic and foreign, automotive and fuel researchers are trying to reduce vehicle exhaust emissions, through a lot of approaches, which consist of new engine design and innovative after-treatment systems, using clean (eco-friendly alternative) fuels and fuel quality improvement. This research is proceeding by two main issues : exhaust emissions and PM particle emissions of gasoline vehicle. Exhaust emissions, non-regulated emissions and PM (particulate matter) particles of automotive are causing many problems which ambient pollution and harmful effects on the human body. The main particulate fraction of automotive exhaust emissions consists of small particles. Because of their small size, inhaled particles can easily penetrate deep into the lungs. The rough surfaces of these particles make it easier for them to combine with other toxins in the environment. Thus, the hazards of particle inhalation are increased. Based on the oxygenated fuel additive types (MTBE, Bio-ETBE, Bio-ethanol, Bio-butanol), this paper discussed the influence of oxygen contents on gasoline vehicle exhaust emissions, non-regulated emissions and nano-particle emissions. Also, this paper assessed exhaust emission characteristics at 2 type test modes. The test modes were FTP-75 and HWFET. All measurement items be verified less than the value of regulated emissions. It could be known difference increase and decrease by each measurement item depending on increase the oxygen contents.

Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode (자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향)

  • Jeong, Woon-Chan;Joo, Young-Cheol
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.85-90
    • /
    • 2021
  • The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom's lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, mAs, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 cm and 8 cm back and forth and compared dose factors and image quality. The exposure parameters were 85 kVp, 320 mA, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 cm. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 mGy, without AEC was 2.12±0.01 mGy. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD were 1.09±0.004 mGy, 0.32±0.003 mGy, 1.19±0.017 mGy, 1.11±0.006 mGy respectively, SNR were 18.29±0.60 dB, 11.11±0.22 dB, 18.98±0.80 dB, 17.71±0.82 dB. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and mAs by 38%, without any difference in SNR(p<0.05). When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

DNN Model for Calculation of UV Index at The Location of User Using Solar Object Information and Sunlight Characteristics (태양객체 정보 및 태양광 특성을 이용하여 사용자 위치의 자외선 지수를 산출하는 DNN 모델)

  • Ga, Deog-hyun;Oh, Seung-Taek;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.23 no.2
    • /
    • pp.29-35
    • /
    • 2022
  • UV rays have beneficial or harmful effects on the human body depending on the degree of exposure. An accurate UV information is required for proper exposure to UV rays per individual. The UV rays' information is provided by the Korea Meteorological Administration as one component of daily weather information in Korea. However, it does not provide an accurate UVI at the user's location based on the region's Ultraviolet index. Some operate measuring instrument to obtain an accurate UVI, but it would be costly and inconvenient. Studies which assumed the UVI through environmental factors such as solar radiation and amount of cloud have been introduced, but those studies also could not provide service to individual. Therefore, this paper proposes a deep learning model to calculate UVI using solar object information and sunlight characteristics to provide an accurate UVI at individual location. After selecting the factors, which were considered as highly correlated with UVI such as location and size and illuminance of sun and which were obtained through the analysis of sky images and solar characteristics data, a data set for DNN model was constructed. A DNN model that calculates the UVI was finally realized by entering the solar object information and sunlight characteristics extracted through Mask R-CNN. In consideration of the domestic UVI recommendation standards, it was possible to accurately calculate UVI within the range of MAE 0.26 compared to the standard equipment in the performance evaluation for days with UVI above and below 8.