• Title/Summary/Keyword: The measurement of Shaft electromotive forces

Search Result 1, Processing Time 0.013 seconds

A Study on Characteristic Analysis of Shaft Electromotive Force in SAEYUDAL (새유달호 축기전력의 특성 분석에 관한 연구)

  • Ahn, Byong-Won;Im, Myeong-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.28-31
    • /
    • 2015
  • Electromotive forces (EMF) are generated by electrical equipment and engine shafting with a number of reasons. The shaft and bearing which is insulated by lubricating oil acts as a condenser, being able to store this EMFs. The electromotive force on the hull and shaft, with very few exceptions, has anode voltage on it. Electrical spark of the anode voltage on the shaft may lead to corrosion. Hence, in order to prevent ship's shaft and propeller corrosion, shaft grounding system are installed and operated. The shaft EMF voltage measurement methods was measured using 24bit 2 channels A/D converter of NI company and Labview software. 1 channel was propeller shaft's voltage and the other was M/E engine rpm gauge. In this paper, the generated electromotive force was analyzed and modeled with result of the analysis. As a result, the main shaft's electromotive force was in direct proportion to the main engine's revolution. However, over the specific R.P.M., it was reduced gradually. In addition, higher electromotive force on the shaft was identified during engine's ahead direction than the astern direction. The generated electromotive force is only minor compared to the shaft grounding system.