• Title/Summary/Keyword: The long-term durability

Search Result 500, Processing Time 0.029 seconds

An Experimental Study on Relation between Chloride Diffusivity and Microstructural Characteristics for GGBS Concrete (슬래그 미분말 혼합 콘크리트의 공극구조와 염화물 확산계수와의 관계에 대한 실험적 연구)

  • Kim, Tae-Sang;Jung, Sang-Hwa;Choi, Young-Cheol;Song, Ha-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.639-647
    • /
    • 2009
  • In order to evaluate the durability of reinforced concrete structures under chloride attack from sea water and frost damage, it is important to analyze both the microstructural characteristics of concrete and its diffusion resistance of concrete against chloride ingress. In this study, a relation between micro-pore structures of concrete obtained by the Mercury Intrusion Porosimetry and accelerated chloride diffusivity as well as long term chloride diffusivity were studied for ground granulated blast furnace slag(GGBS) concrete. Different water-cement ratio of 40, 45, 50% and different unit cement concrete of 300, 350, 400 or 450 kg/$m^3$ of the GGBS concrete along with OPC concrete were used and freeze and thawing, and the change in diffusivity and microstructure were observed for both GGBS concrete and damaged GGBS concrete due to rapid freezing and thawing.

Characteristics of Flexural Capacity and Ultrasonic in RC member with Corroded Steel and FRP Hybrid Bar (부식된 FRP Hybrid Bar의 휨 내력 및 초음파 속도 특성)

  • Choi, Se-Jin;Mun, Jin-Man;Park, Ki-Tae;Park, Cheol-Woo;Kwon, Seung-Jun
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.8
    • /
    • pp.397-407
    • /
    • 2015
  • Concrete is a attractive construction material, however durability problem occur due to steel corrosion, which leads propagation to structural safety problem. The recently developed FRP (Fiber Reinforced Plastic) Hybrid Bar has an engineering merit of both structural steel and FRP. Accelerated corrosion test for RC (Reinforced Concrete) samples with normal steel and FRP Hybriud Bar are performed and their flexural capacity is evaluated. Furthermore UV(Ultrasonic Velocity) measurement is attempted for analysis of variation of UV due to corrosion condition. After corrosion test, there is no significant reduction in RC beam with FRP hybrid bar but 11.5% of reduction in the case of normal steel is evaluated with 3.3% of UV reduction. For commercial production of FRP hybrid bar, bond strength evaluation through long-term submerged corrosion is required.

Study on Utilization of Electric Arc Furnace Oxidizing Slag as Fine Aggregates for Cement Concrete (전기로 산화 슬래그의 콘크리트용 잔골재 활용)

  • Kim, Sang Myoung;Park, Ju Won;Lee, Hoon Ha;Kim, Ki Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.407-415
    • /
    • 2008
  • Hydration reaction of Free-CaO is thought to be the main reason of expansion failure of slag. A lot of research institutions are conducting studies on solutions to this problem, and moreover it has been carried out how to make use of aggregates for concrete. While studies covering wide rage of blast furnace slag have been accomplished in the country, studies on steelmaking slag are insufficient. Therefore, this study aimed at analyzing basic physical properties of electric arc furnace oxidizing slag, which is the main material, and furthermore it focused on how to make use of aggregates for concrete examining chemical mechanism, which can be put to practical use. To address this issue, components of electric arc furnace oxidizing slag were analyzed with measurement of physical properties, followed by long-term strength and detailed durability analysis, which can evaluate the appropriateness of application of cement concrete. Besides the environmental conservation and recycling which can be obtained by application of industry byproducts, commercializing of electric arc furnace oxidizing slag as fine aggregates for cement concrete are expected.

Chloride Penetration Resistance and UV Properties in Coating Materials Containing Various Slime-Forming Bacteria (슬라임 생성 박테리아를 혼입한 코팅재의 염해 저항성 및 초음파 특성)

  • Kwon, Seung-Jun;Yoon, Hyun-Sub;Yang, Keun-Hyeok
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.395-402
    • /
    • 2017
  • Recently, many researches on crack healing and repairing technique using bacteria which can produce vital-reacted calcite have been proposed. This study is for a basic research on repair material with slime formation through bacteria and deals with durability evaluation for coating materials containing bacteria-forming slime. For the work, 4 types of bacteria (Rhodobacter capsulatus, Rhodopseudomonas palustris, Bacillus thuringiensis, and Bacillus subtilis) and 2 types of nutrient conditions are considered, and several tests covering strength evaluation under sulfate condition, accelerated chloride diffusion, and UV (Ultrasonic Velocity) measurement are performed. Strength improvement in coating materials containing bacteria is evaluated in spite of even exposure to sulfate attack to 7 days. Chloride diffusion coefficient and UV properties are also improved except for the case of Rhodopseudomonas palustris. With resistance of slime to long term exposure and aerobic conditions for bacteria longevity, the proposed bacteria shows an engineering feasibility for repair material of RC structure exposed harsh environment.

The Effect of Gaps in Concrete Bearing Surface of Direct Fixation Track on Vehicle and Track Interaction (직결궤도 체결구 하부에 발생한 단차가 차량/궤도 상호작용에 미치는 영향)

  • Yang, Sin-Chu;Kim, Eun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.50-57
    • /
    • 2010
  • Various installation faults may lie in fasteners in the construction of a direct-fixation track by the top-down method. At an extreme, they may cause excessive interaction between the train and track, compromise the running safety of the train, and cause damage to the track components. Therefore, the faults need to be kept within the allowable level through an investigation of their effects on the interactions between the train and track. In this study, the vertical dynamic stiffness of fasteners in installation faults was measured based on the dynamic stiffness test by means of an experimental apparatus that was devised to feasibly reproduce gap faults. This study proposes an effective analytical model for a train-track interaction system in which most elements, except the nonlinear wheel-rail contact and some components that behave bi-linearly, exhibit linear behavior. To investigate the effect of the behavior of fasteners in gap faults in a direct-fixation track on the vehicle and track, vehicle-track interaction analyses were carried out, targeting key review parameters such as the wheel load reduction factor, vertical rail displacement, rail bending stress, and mean stress of the elastomer. From the results, it was noted that the gap faults in the concrete bearing surface of a direct-fixation track need to be limited for the sake of the long-term durability of the elastomer than for the running safety of the train or the structural safety of the track.

  • PDF

Permanent Sprayed Concrete Tunnel Linings Waterproofed with Bonded Membranes. A Review of the Current State-of-the-art for Hard Rock Conditions

  • Holter, K.G.
    • Magazine of korean Tunnelling and Underground Space Association
    • /
    • v.21 no.2
    • /
    • pp.103-116
    • /
    • 2019
  • Permanent sprayed concrete tunnel linings waterproofed with bonded membranes have been used at a number of important traffic projects over the last decade. Research has been carried out in several teams in order to increase the understanding of the function, properties and behavior of such linings under different loading and boundary conditions. The basic layout of this lining gives fundamental different system properties compared to the traditional lining systems. The main differences pertain to the groundwater exposure and the resulting hydraulic loading, the response of the concrete and membrane materials to this loading, as well as the geomechanically induced loading of the lining structure. The current understanding of the function and properties of such lining structures is presented in the paper based on review of recent research carried out in Norway, as well as field observations and monitoring carried over a several years. The influence of the water exposure on the final condition of the concrete and membrane materials has proven to be of vital importance for proper material testing and acceptance, assessments of the mechanical contribution of the bonded membrane, as well as assessments of the longterm durability of such linings. Obtaining realistic material parameters for the concrete and membrane materials subject to the boundary conditions posed by the groundwater exposure in an undrained structure is emphasized. Finally, some recent results from currently ongoing research on such linings, particularly the hydraulic response of the rock mass and the long term behavior of the concrete and membrane materials are presented.

Rayleigh wave for detecting debonding in FRP-retrofitted concrete structures using piezoelectric transducers

  • Mohseni, H.;Ng, C.T.
    • Computers and Concrete
    • /
    • v.20 no.5
    • /
    • pp.583-593
    • /
    • 2017
  • Applications of fibre-reinforced polymer (FRP) composites for retrofitting, strengthening and repairing concrete structures have been expanded dramatically in the last decade. FRPs have high specific strength and stiffness compared to conventional construction materials, e.g., steel. Ease of preparation and installation, resistance to corrosion, versatile fabrication and adjustable mechanical properties are other advantages of the FRPs. However, there are major concerns about long-term performance, serviceability and durability of FRP applications in concrete structures. Therefore, structural health monitoring (SHM) and damage detection in FRP-retrofitted concrete structures need to be implemented. This paper presents a study on investigating the application of Rayleigh wave for detecting debonding defect in FRP-retrofitted concrete structures. A time-of-flight (ToF) method is proposed to determine the location of a debonding between the FRP and concrete using Rayleigh wave. A series of numerical case studies are carried out to demonstrate the capability of the proposed debonding detection method. In the numerical case studies, a three-dimensional (3D) finite element (FE) model is developed to simulate the Rayleigh wave propagation and scattering at the debonding in the FRP-retrofitted concrete structure. Absorbing layers are employed in the 3D FE model to reduce computational cost in simulating the practical size of the FRP-retrofitted structure. Different debonding sizes and locations are considered in the case studies. The results show that the proposed ToF method is able to accurately determine the location of the debonding in the FRP-retrofitted concrete structure.

Properties of High Strength Recycled Aggregate Concrete (고강도 영역의 재생골재 콘크리트의 물리적 특성)

  • 이세현;서치호
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.575-583
    • /
    • 2001
  • The purpose of this study is to present the method of utilizing the recycled aggregate that are obtained from waste concrete as the concrete aggregate. We manufactured the recycled aggregate concrete with compressive strength of over 300kgf/㎠ to increase its weaker strength than the normal concrete, and compared the physical features of the recycled aggregate concrete with that of the normal concrete. As a result of the study, the mechanical performances such as compressive and tensile strength were generally reduced as the mixing rate of the recycled aggregate increased; however, it was possible to manufacture the concrete with the compressive strength of 300∼600kgf/㎠ using the adequate mixing material such as unit quantity of cement, compounding water and silicafume. However, a continuous study on long-term durability performance is required to manufacture and utilize the recycled aggregate concrete for the structure.

Development of the Bus Duct Installation System for Wind Tower (풍력타워용 부스덕트 포설시스템 개발)

  • Rhee, Huinam;Lee, Joon Keun;Kim, Bong-Seok;Park, Seong-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.219-226
    • /
    • 2014
  • A bus duct system for wind tower is introduced. A marine cable has been widely used in wind tower or various offshore structures. However, as the electric load capacity is increases, large number of cable lines must be used to cover the huge amount of electric capacities. Therefore, the installation of the cable lines becomes very difficult due to the heavy weight and volume of the cables. On the other hand, by using a single bus duct system line, the power capacity amount of 16 cables can be delivered with significantly compacted form. However, unlike flexible cables, the bus duct is relatively stiff which could generate the resonance phenomenon in the operating condition of the wind tower. In this study, the vibration characteristics of the bus duct are investigated and its long-term reliability during the life time of the wind tower is verified.

Application of FBG Sensors on a Cantilever Beam for Analyzing Behavior of Laterally Loaded Piles (실내 모형실험을 통한 수평재하 말뚝의 거동측정을 위한 FBG 센서의 적용성 평가)

  • Lee, Tae-Hee;Chung, Won-Seok;Jung, Young-Hoon;Mok, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.587-597
    • /
    • 2010
  • Analysis of the behavior of a laterally loaded pile is important in the design of critical civil structures. Recently, the electric strain gauge has been widely used to measure the strains along the pile. The electric strain gauge, due to lack of durability, is inappropriate in the use of long-term measurements. Herein, the feasibility of implementing the FBG sensor was investigated using a cantilever-type calibrator in laboratory. A special calibrating tool called "cantilever-calibrator" was used to calibrate the FBG sensors. The calibrator consists of a special calibration beam, a holding-clamp at one end of the beam, and a micrometer on the other end. Three FBG sensors were installed on the calibration beam. The strains measured by FBG sensors were compared with those calculated theoretically using cantilever beam theory. The calibration factor of FBG sensors were suggested to compensate the difference between measured and calculate strains.

  • PDF