• 제목/요약/키워드: The height of wall

검색결과 896건 처리시간 0.027초

V 형 rib과 dimple로 구성된 SAH 덕트에서의 총괄 열성능에 대한 수치적 연구 (Numerical study on overall thermal performance in SAH duct with compound roughness of V-shaped ribs and dimples)

  • 아닐 쿠마르;김만회
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.43-55
    • /
    • 2015
  • This paper presents the thermal hydraulic performance of a three dimensional rib-roughened solar air heater (SAH) duct with the one principal wall subjected to uniform heat flux. The SAH duct has aspect ratio of 12.0 and the Reynolds number ranges from 2000 to 12000. The roughness has relative rib height of 0.045, ratio of dimple depth to print diameter of 0.5 and rib pitch ratio of 8.0. The flow attack angle is varied from $35^{\circ}$ to $70^{\circ}$. Various turbulent flow models are used for the heat transfer and fluid flow analysis and their results are compared with the experimental results for smooth surfaces. The computational fluid dynamics (CFD) results based on the renormalization k-epsilon model are in better outcomes compared with the experimental data. This model is used to calculate heat transfer and fluid flow in SAH duct with the compound roughness of V-shaped ribs and dimples. The overall thermal performance based on equal pumping power is found to be the highest (2.18) for flow attack angle of $55^{\circ}$. The thermo-hydraulic performance for V-pattern shaped ribs combined with dimple ribs is higher than that for dimple rib shape and V-pattern rib shape air duct.

A case of Sotos syndrome presented with end-stage renal disease due to the posterior urethral valve

  • Cho, Won Im;Ko, Jung Min;Kang, Hee Gyung;Ha, Il-Soo;Cheong, Hae Il
    • Journal of Genetic Medicine
    • /
    • 제11권2호
    • /
    • pp.74-78
    • /
    • 2014
  • Sotos syndrome (SS, OMIM 117550) is characterized by prenatal and postnatal overgrowth with multiple congenital anomalies. However, there have been few cases of growth retardation caused by renal failure from infancy. We report a case of dysplasia of the bilateral kidneys with renal failure and poor postnatal growth. A 2-month-old boy visited the emergency room owing to poor oral intake and abdominal distension. He was born at the gestational age of 38 weeks with a birth weight of 4,180 g. After birth, he had feeding difficulty and abdominal distension. Upon physical examination, his height and weight were in less than the 3rd percentile, while his head circumference was in the 50th percentile on the growth curve. He also showed a broad and protruding forehead and high hairline. Blood laboratory tests showed severe azotemia; emergent hemodialysis was needed. Abdominal ultrasonography revealed bilateral renal dysplasia with multiple cysts and diffuse bladder wall thickening. A posterior urethral valve was suggested based on vesicoureterography and abdominal magnetic resonance findings. Results of a colon study to rule out congenital megacolon did not reveal any specific findings. The conventional karyotype of the patient was 46, XY. Array comparative genomic hybridization study revealed a chromosome 5q35 microdeletion including the NSD1 gene, based on which SS was diagnosed. We describe a case of SS presenting with end stage renal disease due to posterior urethral valve. The typical somatic overgrowth of SS in the postnatal period was not observed due to chronic renal failure that started in the neonatal period.

외부순환 공기부양반응기에서 낮은 주파수의 압력 변동 (Low-Frequency Pressure Fluctuations in an External-Loop Airlift Reactor)

  • 최근호
    • Korean Chemical Engineering Research
    • /
    • 제58권4호
    • /
    • pp.665-674
    • /
    • 2020
  • 외부순환형 공기부양반응기에서 낮은 주파수의 압력 변동에 대해 연구하였다. 상승관과 하강관의 상부와 하부에 설치된 내압관의 액면을 휴대폰으로 촬영하는 방법으로 빠른 주파수의 변동이 제거된 압력을 측정하였다. 자기상관함수와 교차상관함수의 계산을 통해 압력의 주기적인 변동을 확인하였다. 기체속도가 일정하여도 순환액체의 관성으로 인해 압력은 물론이고 상승관과 하강관내의 기체체류량도 주기적으로 변동하였다. 일반적으로 기체유속이 증가할수록 압력 변동의 강도는 커졌다. 비분산 액체높이가 0.04 m일 때 압력 변동의 주기는 기체속도가 0.14 ms-1에서 극대값을 보여주었다. 이는 기체속도가 커질수록 순환 액체속도의 증가율은 둔화하고 효과적으로 순환하는 액체의 부피가 감소하므로 순환액체의 관성이 극대값을 보이기 때문이다.

FAST 동체의 공력특성에 대한 수치 및 실험 연구 (Numerical and Experimental Study on the Aerodynamic Characteristics of FAST Fuselages)

  • 한철희;조정보;조진수
    • 한국항공우주학회지
    • /
    • 제35권3호
    • /
    • pp.177-182
    • /
    • 2007
  • 경계요소법을 사용하여 세 가지 유형의 전두부 형상과 비 평면 지면이 FAST 동체의 공력 특성에 미치는 영향을 연구하였다. 본 수치해석 기법을 검증하고 벽면의 영향이 마찰항력에 미치는 영향을 파악하기 위하여 풍동시험을 수행하였다. 채널은 동체의 양력을 증가시키는 효과가 있었다. 최적의 전두부 형상은 동체와 측면 벽 사이의 간격, 동체의 높이와 같은 FAST 및 안내로 설계 조건에 의존하였다. 계산한 유도항력계수 값과 측정한 전항력 값을 비교한 결과 형상 항력은 동체의 고도에 무관하였다. 지면효과를 받지 않는 동체의 형상항력 값을 알고 있다면, 본 수치기법은 고속 지상 운행체의 개념설계에 사용할 수 있다.

이중 블라인드 광파이프 주광 조명시스템 효율 및 조명에너지 절감량 평가 연구 (Evaluation Study of a Double Blind Light Pipe Daylighting System Efficiency and an Illumination Energy Reduction)

  • 강은철;유성연;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제33권1호
    • /
    • pp.89-95
    • /
    • 2013
  • A DBLP(Double blind light pipe) daylight system can be installed at a building exterior wall or roof to replace artificial light during the day time. This system was consisted of a double blind light collector, a mirror duct type light transformer and a prism light pipe distributor. The double blinds were used to track the sun's altitude and azimuth movements to collect the sunlight throughout the day. The sunlight collected by the light collector was reflected on the first mirror and the second mirror and sent to the light pipe through the light transformer. The transformer was designed to deliver the sunlight into the light pipe efficiently. The light distributor plays a role in diffusing the sunlight coming in through the light collector to be used for indoor lighting. In this paper, a DBLP system has been designed, installed and tested at a KIER daylighting twin test cell. The DBLP daylighting system was applied to the experimental test cell which has an indoor area of 2.0 m wide ${\times}$ 2.4 m height ${\times}$ 3.8 m length. The experiment was conducted from January 30 to February 27, 2012, under clear skies and partially cloudy skies. Data was collected from 10:00 am to 16:00 pm every 2 minute and the average was calculated for every 30 minute of the data collection to obtain the system efficiency. The results indicated that the DBLP system efficiency was evaluated as 11.67%. The DBLP system indoor illumination energy reduction was predicted as 0.822 kWh/day. This could replace 4 sets of a 32W fluorescent lamp operating 6.4 hours per a day.

Flow characteristics after water inrush from the working face in karst tunneling

  • Wu, J.;Li, S.C.;Xu, Z.H.;Pan, D.D.;He, S.J.
    • Geomechanics and Engineering
    • /
    • 제14권5호
    • /
    • pp.407-419
    • /
    • 2018
  • In order to investigate flow characteristics after water inrush from the working face in process of karst tunnel construction, numerical calculation for two class case studies of water inrush is carried out by using the FLUENT software on the background of Qiyueshan tunnel. For each class water inrush from the tunnel face, five cases under different water-inrush velocity are simulated and researched. Three probing lines are selected respectively in the left tunnel, cross passage, right tunnel and in the height direction of the tunnel centerline. The variation characteristics of velocity and pressure on each probing line under the five water-inrush velocities are analyzed. As for the selected four groups probing lines in the tunnels, the change rules of velocity and pressure on each group probing lines under the same water-inrush velocity are discussed. Finally, the water flow characteristics after inrush from the tunnel face are summarized by comparing the case studies. The results indicate that: (1) The velocity and pressure change greatly at the intersection area of the cross passage and the tunnels. (2) The velocity nearby the tunnel side wall is the minimum, while it is the maximum in the middle position. (3) The pressure value of every cross section in the tunnels is basically fixed. (4) As water-inrush velocity increases, the flow velocity and pressure in the tunnels also increase. The former is approximately proportional to their respective water-inrush velocity, while the latter is not. The research results provide a theoretical basis for making scientific and rational escape routes.

The interaction between helium flow within supersonic boundary layer and oblique shock waves

  • Kwak, Sang-Hyun;Iwahori, Yoshiki;Igarashi, Sakie;Obata, Sigeo
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.75-78
    • /
    • 2004
  • Various jet engines (Turbine engine family and RAM Jet engine) have been developed for high speed aircrafts. but their application to hypersonic flight is restricted by principle problems such as increase of total pressure loss and thermal stress. Therefore, the development of next generation propulsion system for hypersonic aircraft is a very important subject in the aerospace engineering field, SCRAM Jet engine based on a key technology, Supersonic Combustion. is supposed as the best choice for the hypersonic flight. Since Supersonic Combustion requires both rapid ignition and stable flame holding within supersonic air stream, much attention have to be given on the mixing state between air stream and fuel flow. However. the wider diffusion of fuel is expected with less total pressure loss in the supersonic air stream. So. in this study the direction of fuel injection is inclined 30 degree to downstream and the total pressure of jet is controlled for lower penetration height than thickness of boundary layer. Under these flow configuration both streams, fuel and supersonic air stream, would not mix enough. To spread fuel wider into supersonic air an aerodynamic force, baroclinic torque, is adopted. Baroclinic torque is generated by a spatial misalignment between pressure gradient (shock wave plane) and density gradient (mixing layer). A wedge is installed in downstream of injector orifice to induce an oblique shock. The schlieren optical visualization from side transparent wall and the total pressure measurement at exit cross section of combustor estimate how mixing is enhanced by the incidence of shock wave into supersonic boundary layer composed by fuel and air. In this study non-combustionable helium gas is injected with total pressure 0.66㎫ instead of flammable fuel to clarify mixing process. Mach number 1.8. total pressure O.5㎫, total temperature 288K are set up for supersonic air stream.

  • PDF

주거공간 에어로 시스템 배치에 관한 화재시뮬레이션 연구 (A Study on Fire Dynamics Simulation on the Arrangement of Aero System in the Residential)

  • 최두찬;고민혁;이두희;박계원;최정민;이용권;김길남;선경수
    • 한국재난정보학회 논문집
    • /
    • 제17권4호
    • /
    • pp.890-896
    • /
    • 2021
  • 연구목적: '에어로 시스템'이란 제품을 개발하였으며, 화재 특성상 신속한 감지가 무엇보다 중요함으로 개발하고 있는 제품을 주거 공간 어느 지점에 배치를 하였을 때 신속하게 감지를 할 수 있는지 화재 시뮬레이션을 통해 확인하고자 하였다. 연구방법: 18평형의 주거 공간에서 화재시뮬레이션을 수행하였으며, 화재 환경이 빨리 노출되는 지점을 찾고자 침실, 거실 별로 측정점을 높이 0.6m, 1.5m 지점으로 설치하여 빨리 감지 되는 지점을 확인하였다. 연구결과: 대부분 1.5m 지점으로 설정한 온도 및 일산화탄소 센서가 기준 치에 빨리 감지 되는 지점을 확인하였다. 결론: 소화모듈과 AQI모듈이 분리된 제품을 벽에 부착형으로 설치할 경우 화재 감지가 상대적으로 빠른 것으로 확인되었다.

FDS를 이용한 실규모 공연장 무대 내 화재 시 연기 거동 분석: 방화막 및 자연배출구 면적의 영향 (Analysis of Smoke Behavior in Fire within Real-scale Theater Using FDS: Influences of Fire Curtain and Natural Smoke Vent Area)

  • 김재한;이치영;정이규;김동균
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.7-14
    • /
    • 2018
  • 본 연구에서는 방화막 및 자연배출구 면적이 공연장 무대 화재 시 연기 거동에 미치는 영향에 대해 Fire Dynamics Simulator (FDS)를 이용하여 전산시뮬레이션(Numerical simulation)을 수행하였다. 공연장의 무대 크기는 폭 31 m, 깊이 34 m, 높이 32 m로 설정하였고, 자연배출구 면적은 무대 바닥면적의 약 10%, 약 8%, 약 5%, 약 1%로 하였다. 방화막은 프로시니엄(Proscenium) 벽과 0.5 m 이격하여 설정하였다. 방화막과 자연배출구 면적은 객석으로의 연기유출, 자연배출구 및 프로시니엄 개구부를 통한 유입 및 유출 질량 유량에 지대한 영향을 미치는 것으로 관찰되었고, 동일한 자연배출구 면적 조건에서 방화막이 설치된 경우가 미설치된 경우에 비해 무대 내 압력이 더 낮은 것으로 나타났다.

Subxiphoid Incisional Hernia Development after Coronary Artery Bypass Grafting

  • Kim, Hye-Seon;Kim, Ki-Bong;Hwang, Ho-Young;Chang, Hyung-Woo;Park, Kyu-Joo
    • Journal of Chest Surgery
    • /
    • 제45권3호
    • /
    • pp.161-165
    • /
    • 2012
  • Background: Median sternotomy can weaken the upper abdominal wall and result in subxiphoid incisional hernia. We evaluated risk factors associated with the development of subxiphoid incisional hernias after coronary artery bypass grafting (CABG). Materials and Methods: Of 1,656 isolated CABGs performed between January 2001 and July 2010, 1,599 patients who were completely followed up were analyzed. The mean follow-up duration was $49.5{\pm}34.3$ months. Subxiphoid incisional hernia requiring surgical repair developed in 13 patients (0.8%). The hernia was diagnosed $16.3{\pm}10.3$ months postoperatively, and hernia repair was performed $25.0{\pm}26.1$ months after the initial operation. Risk factors associated with the development of subxiphoid incisional hernia were analyzed with the Cox proportional hazard model. Results: Five-year freedom from the hernia was 99.0%. Univariate analysis revealed that female sex (p=0.019), height (p=0.019), body surface area (p=0.046), redo operation (p=0.012), off-pump CABG (p=0.049), a postoperative wound problem (p=0.041), postoperative bleeding (p=0.046), and low cardiac output syndrome (p<0.001) were risk factors for the development of the hernia. Multivariable analysis showed that female sex (p=0.01) and low cardiac output syndrome (p<0.001) were associated with subxiphoid hernia formation. Conclusion: Female sex and postoperative low cardiac output syndrome were risk factors of subxiphoid hernia. Therefore, special attention is needed for patients with high-risk factors.