• Title/Summary/Keyword: The fire district

Search Result 60, Processing Time 0.024 seconds

Field working and Fire extinguishing performance of an Indoor Fire-fighting Robot (실내화재진압로봇의 현장운용 및 소화성능평가)

  • Kwark, Ji-Hyun;Kim, Jong-Kwon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.163-167
    • /
    • 2008
  • Fire-fighters are struggling against heat and dense smoke by fire when it occurs at the basement or the inner place of a building. An indoor fire-fighting robot with well heat-resistance, great searching cameras and good extinguishing ability has been developed. It never suffocate, coming into the fire district and extinguishes fire directly. In this study, several experiment was conducted to evaluate field working ability of the fire-fighting robot. As a result, a series of passing obstacles, finding fire place and fire suppression by the remote controlling with image information appeared satisfactory.

  • PDF

Evaluation of Field working Improvement for an Indoor Fire-fighting Robot (실내화재진압로봇의 현장운용성 향상을 위한 실용성 평가)

  • Kwark, Ji-Hyun;Lee, Woo-Jun;Kim, Jong-Kwon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.126-131
    • /
    • 2008
  • Fire-fighters have been struggling against heat and dense smoke caused by fire when it occurs especially at the basement or the inner place of a building. An indoor fire-fighting robot with well heat-resistance, great searching cameras and good extinguishing ability has been recently developed. It never suffocate, coming into the fire district and extinguishes fire directly. In this study, several experiment was conducted to promote field working ability of the fire-fighting robot. As a result, heat resistance, water discharge and field working appeared satisfactory.

  • PDF

A Study on the Emergency Medical Service Demand and Fire Service Force (구급서비스 수요와 소방력에 관한 연구)

  • Kim, Jin-Dong;Shin, Sang-Yol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4485-4491
    • /
    • 2013
  • This study was to investigate emergency medical service demands, fire service force of local governments, and relationship between these two factors for developing effective prehospital emergency medical services. For this, this study was measured the ratio of the number of patients transported and residents, ambulances and residents, patients transported and ambulance workers of 16 local governments. And then examined hypotheses. Data were collected from 2000 year to 2010 year. This study results indicated that average number of patients transported are significant differences not only between metropolitan district and general district, but also between capital area and non-capital area. And this study indicated that the fire service force are significant differences not only between metropolitan district and general district, but also between capital area and non-capital area. Also, the numbers of patients transported per ambulance, and the numbers of patients transported per ambulance worker were significant by regional groups. The number of patients transported per ambulance was a significant difference between the first half and the second half, but there was not a significant different the number of patients transported between the first half and the second half.

A case study on the fire victim in the vehicle by GC/MS through derivatization of cyanide with pentafluorobenzyl bromide (PFBBr) (시안화이온의 pentafluorobenzyl bromide (PFBBr)에 의한 유도체화 후 GC/MS 분석에 의한 차량화재 변사체 사인규명에 관한 사례연구)

  • Lee, Joon-Bae;Shon, Sung Kun;Woo, Sang Hee;Park, Se Yeon;Hwang, Jung Ho;Kwon, O-Seong;Kim, Nam Yi;Paeng, Ki Jung
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.73-78
    • /
    • 2016
  • Hydrogen cyanide (HCN) is an extremely toxic gas frequently produced during the incineration of plastics, such as acrylonitrile-butadiene-styrene (ABS). A victim of a fire who has inhaled smoke could have cyanide in the blood. Therefore, cyanide could be a good marker for a post-mortem examination of a fire as well as carboxyhemoglobine (COHb) test of blood samples. For a particular fire case, a burned body with a suicide note was found inside a burned vehicle. Even though the COHb value is conclusive evidence, measuring the COHb for denatured blood might be difficult due to severe thermal denaturation or the formation of methemoglobin (MetHb). To overcome this difficulty, cyanide could be used as an indicator when investigating the death of a fire victim. In this study, gas chromatography/mass spectrometry (GC/MS) was adopted to measure the levels of cyanide in the blood through derivatization with pentafluorobenzyl bromide (PFBBr) under cation surfactant by scan and SIM mode. The concentration of cyanide in the blood of heart blood and brain of the victim was found to be 0.36 µg/mL and 1.20 µg/mL respectively, which was higher than the average value (0.041 µg/mL) found in the blood of 14 people who smoked.

Analysis of Spatial Characteristics of Old Building Districts to Evaluate Fire Risk Factors (화재 위험요소의 도출을 위한 노후건축지구의 공간구성 특성분석)

  • Son, Byeung-Hun;Kang, Kyung-Ha;Ryu, Jung-Rim;Roh, Seung-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.69-80
    • /
    • 2022
  • The proportion of buildings over 30 years old in Korea has increased, from 29.0% in 2005 to 37.8% in 2019. These old buildings were built during a time in which there was a lack of building-related safety standards in areas such as fire safety performance. Worse, during their years of use, many such old buildings have had illegal changes and extensions made, making them more vulnerable in terms of safety. Fire safety investigations are being conducted to prevent large-scale disasters in multi-use buildings, but no investigation has been conducted at the regional district level, where small-scale old buildings are concentrated. Therefore, to identify fire risk factors in the old building district where old buildings are concentrated, the composition characteristics of the buildings were first analyzed. To examine the spatial characteristics of old building districts in order to derive fire risk factors, the results of this analysis based on the structure, use, roof type, and year of approval for use are as follows. It was found through our analysis that as of the date of approval for the use of the building, the main structure of the building has the greatest impact.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

A Study on the Problems and Character for Management of Fire Prevention at the Wholesale Markets (도매시장 화재안전관리 측면에서의 특성 및 취약요소에 관한 연구)

  • Park, Jae-Sung;Im, Jae-Keun
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.150-158
    • /
    • 2010
  • There are lots of buildings with their deterioration in wholesale markets which have high concentration that can cause big fire due to difficulty of installing fire protection system in fire compartment, absence of safety awareness, access by many and unspecified people. There had been big fire that caused by these kind of fire weakness such as Seomun Market's in 2005 which costed tens of millions dollar, Dongmun Shopping District’s with 7 casualties. Now counter-measure against these fire is urgently needed. This study drew characteristic of current condition of wholesale markets and the one classified by main agent, fire cases and prevention of fire through statistical data. Also, current condition of fire prevention management and actual state were investigated by conducting a survey of person in charge of fire prevention and current practician. As a result, it was shown that securing professionalism of fire prevention, improvement of structural weakness of buildings, obtaining reliability on performance of fire protection system and internal fire education against practician in the market are needed.

Effects of Urban Greenspace on Microclimate Amelioration, $CO_2$ Sequestration and Eire Obstruction (도시녹지의 미기후개선, $CO_2$흡수 및 화재방지의 효과)

  • ;Yoshiteru Nojima
    • Korean Journal of Plant Resources
    • /
    • v.13 no.3
    • /
    • pp.162-170
    • /
    • 2000
  • This study quantified the effects of urban greenspace on microclimate amelioration and atmospheric $CO_2$ reduction for several residential districts selected in Korea and Japan. The study also explored fire obstruction by urban trees to develop systematic planting guidelines. Transpiration by a Zelkova serrata tree (diameter at breast height: 15 cm) in a day of August equaled cooling effect of about 3 air conditioners running for 12 hours. Average air temperature for the growing season was 0.5$^{\circ}C$ and 1.2$^{\circ}C$ cooler, respectively, in districts with 12% and 22% cover of woody plants than in a district with no vegetation. Annual $CO_2$ uptake and $O_2$ production by woody plants were 3 times greater in a district which was 2 times higher in their cover. Woody plants played, in a district with their 22% cover, an important role through offsetting total $CO_2$ emission from the district by about 3% annually, and through producing 10% of annual $O_2$ requirement by all residents within the district. Appropriate planning strategies of residential greenspace, including species selection, planting layout, greenspace enlargement, and maintenance were suggested to improve microclimate amelioration, air purification, and fire obstruction.

  • PDF

Spatial Clustering Analysis of Fire in Gangwon-Do (강원도 화재의 공간적 군집 특성 분석)

  • BAE, Sun-Hak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.3
    • /
    • pp.93-103
    • /
    • 2018
  • The purpose of this study is to analyze the spatial cluster characteristics of fire using long-term fire data. For this, fire data which were broke out in the last 40 years were converted into GIS data and spatial analysis was performed at Gangwon-do province's minimum administrative district level. In order to grasp the spatial distribution of the fire, Moran's I, Geary's Ci and Getis-Ord's Gi*, which are methods that analyze the local indicators of spatial association(LISA), were used. By integrating the characteristics of the spatial distribution of fire by integrating the results obtained from each analysis, the advantages of the individual analysis methods were reflected in the study results. As a result of the study, hotspot areas of fire in Gangwon-do was derived out. Among the hot spot areas, some areas, where the fire frequency is higher than the adjacent areas, have been identified. The results of this study can be used as information for predicting the fire hazard area and relocating of fire-fighting facilities in the study area.