• Title/Summary/Keyword: The Operation Department

Search Result 13,791, Processing Time 0.045 seconds

INITIAL ACQUISITION PROCEDURE FOR KOMPSAT2 WITH K13ANTENNA

  • Lee Jeong-bae;Yang Hyung-mo;Ahn Sang-il;Kim Eun-kyou
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.501-504
    • /
    • 2005
  • In general, most incomplete communication link setup between satellite and ground station right after separation from launcher come from less accurate orbital vector ground station uses to track the satellite because only predicted orbital state vector is available during first few orbits. This paper describes the developed procedure for successful initial acquisition for KOMPSAT-2 using scanning functions ofK13 antenna system with predicted orbital information. Azimuth scan, raster scan, spiral scan functions were tested with KOMPSA Tl under intentionally degraded orbital information for antenna operation. Through tests, spiral scan function was decided to be best search scan among 3 scans. Developed procedure can assure the successful acquisition only if azimuth offset and time offset value are within +/-2deg and +/-30sec, respectively.

  • PDF

Development of Wireless Communication Based Operation State Monitoring System for Open Rack Vaporizer (무선 통신 기반 해수식 기화기 운영 상태 모니터링 시스템 개발)

  • Yoo, Seung-Yeol;Joen, Ming-Sung;Lee, Jae-Chul;Kang, Dong-Hoon;Kim, Dong-Goen;Lee, Soon-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.5
    • /
    • pp.280-287
    • /
    • 2022
  • An open rack vaporizer is a facility that vaporizes liquefied natural gas using sea water. When a vaporization efficiency of the open rack vaporizer decreases, liquefied natural gas can leak, which can cause great damage to the facility. Operators have to monitor the operation state of the facility in real-time to prevent the accident. However, operators have visited the site and have checked the state by looking at the value of sensors installed in the open rack vaporizer through indicators. For the safe operation of the open rack vaporizer, a monitoring system is needed to monitor the operation state of the open rack vaporizer in real-time without the need for operators to visit the site. In this paper, we developed a long term evolution based monitoring system to monitor the operation state of the open rack vaporizer. The developed system can monitor the real-time operation state of the open rack vaporizer at a control center far from the facility. For the system development, data transmission infrastructure using long term evolution was built. Afterwards a software was developed to monitor the operation state of the open rack vaporizer in real-time using the transmitted data. Finally, performance evaluation was conducted to confirm that the developed system operated successfully without data transmission delay or data missing.

Anticorrosive Monitoring and Complex Diagnostics of Corrosion-Technical Condition of Main Oil Pipelines in Russia

  • Kosterina, M.;Artemeva, S.;Komarov, M.;Vjunitsky, I.;Pritula, V.
    • Corrosion Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.208-211
    • /
    • 2008
  • Safety operation of main pipelines is primarily provided by anticorrosive monitoring. Anticorrosive monitoring of oil pipeline transportation objects is based on results of complex corrosion inspections, analysis of basic data including design data, definition of a corrosion residual rate and diagnostic of general equipment's technical condition. All the abovementioned arrangements are regulated by normative documents. For diagnostics of corrosion-technical condition of oil pipeline transportation objects one presently uses different methods such as in-line inspection using devices with ultrasonic, magnetic or another detector, acoustic-emission diagnostics, electrometric survey, general external corrosion diagnostics and cameral processing of obtained data. Results of a complex of diagnostics give a possibility: $\cdot$ to arrange a pipeline's sectors according to a degree of corrosion danger; $\cdot$ to check up true condition of pipeline's metal; $\cdot$ to estimate technical condition and working ability of a system of anticorrosive protection. However such a control of corrosion technical condition of a main pipeline creates the appearance of estimation of a true degree of protection of an object if values of protective potential with resistive component are taken into consideration only. So in addition to corrosive technical diagnostics one must define a true residual corrosion rate taking into account protective action of electrochemical protection and true protection of a pipeline one must at times. Realized anticorrosive monitoring enables to take a reasonable decision about further operation of objects according to objects' residual life, variation of operation parameters, repair and dismantlement of objects.

Study on Multi-scale Unit Commitment Optimization in the Wind-Coal Intensive Power System

  • Ye, Xi;Qiao, Ying;Lu, Zongxiang;Min, Yong;Wang, Ningbo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1596-1604
    • /
    • 2013
  • Coordinating operation between large-scale wind power and thermal units in multiple time scale is an important problem to keep power balance, especially for the power grids mainly made up of large coal-fired units. The paper proposes a novel operation mode of multi-scale unit commitment (abbr. UC) that includes mid-term UC and day-ahead UC, which can take full advantage of insufficient flexibility and improve wind power accommodation. First, we introduce the concepts of multi-scale UC and then illustrate the benefits of introducing mid-term UC to the wind-coal intensive grid. The paper then formulates the mid-term UC model, proposes operation performance indices and validates the optimal operation mode by simulation cases. Compared with day-ahead UC only, the multi-scale UC mode could reduce the total generation cost and improve the wind power net benefit by decreasing the coal-fired units' on/off operation. The simulation results also show that the maximum total generation benefit should be pursued rather than the wind power utilization rate in wind-coal intensive system.

Agent-based Lift-car Group Operation Optimization Model in High-rise Building Construction

  • Jung, Minhyuk;Park, Moonseo;Lee, Hyun-soo;Hyun, Hosang
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.221-225
    • /
    • 2015
  • To hoist construction workers to their working space is directly related to the productivity of building construction since hoisting tasks are carried out during the working time. In order to reduce hoisting time in the condition that the number of construction lift-cars is limited, various types of the lift-cars group operation plans such as zoning and sky-lobby have been applied. However, previous researches on them cannot be compared in the performance due to their methodological limitation, discrete-event simulation methods, and cannot be find better solution to increase the performance. Therefore, this research proposed the simulation-based optimization model combining the agent-based simulation method to the scatter search optimization methods. Using the proposed model, this paper carried out the comparison analysis on the performance of typical operation plans and also optimize an operation plans by controlling the service range of lift-cars, the size and number of service zones. In this case study, it is verified that better alternatives than typical operation plans can be exists and it is possible to increase the productivity of building construction.

  • PDF

Secondary Adjuvant Operation after Free Flap for Functional and Aesthetic Purposes (유리 피판술 후 기능적, 미용적 목적을 위한 2차 보완수술)

  • Ahn, Hee-Chang;Yang, Eun-Zin;Kim, Chang-Yeon
    • Archives of Reconstructive Microsurgery
    • /
    • v.19 no.2
    • /
    • pp.101-107
    • /
    • 2010
  • Purpose: The free flap has been widely used as one stage reconstructive procedure the skin and soft tissue defect. The secondary adjuvant operations are often needed for better results as functional and aesthetic compartment. Therefore, we focus on the secondary adjuvant surgeries for better outcome after free flaps. Methods: One hundred ninety six consecutive patients underwent free flaps between January, 2002 and February 2009. The cases constituted ninety two male patients and one hundred four female patients. For the patients who got free flap operation, we investigated secondary adjuvant operations what type of procedures was applied according to the reconstructed sites. All clinical data were based on the patient's medical records. Results: Of one hundred ninety six patients in whom free flap was performed, a total of eighty two patients(41.8%) received the secondary adjuvant operation. Because of many patients got multiple secondary adjuvant operations, the number of the secondary adjuvant operation become one hundred fifty five cases. The most common used procedure is a liposuction, and the second one is a lipoinjection. Conclusion: As the secondary adjuvant operation like a liposuction, lipoinjection, etc., satisfaction for operative result was increased in the aspects of function and aesthetics. So the secondary adjuvant operation in free flap surgeries contributed in raising the patient's quality of life.

  • PDF

Master Arm and Control System for Teleoperated Bolting Robot (원격 제어되는 볼팅 로봇을 위한 마스터암과 제어 시스템)

  • Lee, Sang Woo;Park, Jang Woo;Park, Shin Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.2
    • /
    • pp.185-193
    • /
    • 2013
  • The construction automation provides safer and more productive working environment of construction site. We developed the automation system of bolting operation for high-rise building in the previous research. However, this system has a weak point that the operation has to be processed in the air with the operator in the cabin. This weakness leads operators to considerably dangerous environment. Therefore, we proposed the tele-operation system in order to supplement this weak point. Furthermore, it leads more effective operation by application of more intuitive controller; spherical coordinate based Master Arm than the joystick in the Mobile Bolting Robot system. These proposed system and controller were evaluated based on Fitts' law paradigm, which is a general estimation method of speed accuracy of task. Through the experimental results, new developed tele-operation system is compared with the actual operation and it discloses distinctions between two systems. As a result, it is found that new developed teleoperation system can be possible to replace the operation in the cabin.

Enzymatic Hydrolysis of Egg Yolk Protein in Continuous Packed Column Operation

  • Kang, Byung-Chul;Lee, Sang-Uk
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.485-489
    • /
    • 2003
  • Enzymatic hydrolysis of egg yolk Protein was carried out in continuous packed column reactor Five supports for enzyme immobilization were evaluated in this study. We investigated the optimum operation variables - pH, temperature, and flow rate in continuous reactor operation.

  • PDF

Electrokinetic Restoration of Saline Agricultural Land (염류집적 농경지의 전기동력학적 정화)

  • Jo, Sung-Ung;Kim, Do-Hyung;Yang, Jung-Seok;Chung, Keun-Yook;Baek, Ki-Tae
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.19-26
    • /
    • 2012
  • The influence of operation time on electrokinetic restoration was investigated to remove salts from sulfate-accumulated greenhouse soil. Operation time is directly related to the process cost, therefore, we determined the relationship between operation time and removal of salts. Nitrate and sodium were removed almost completely within 2 weeks, chloride and calcium was removed in proportion to the operation time. Sulfate was accumulated at the center of anode and cathode. The soil electrical conductivity (EC), an indicator for soil salinity, showed similar shape with the residual sulfate after electrokinetic treatment. The soil EC was not changed after 2 weeks, however, the energy consumption increased with operation time. Based on the experimental results, most salts except sulfate were removed within 2 weeks, but sulfate was not removed during same time period. For the further removal of sulfate, longer operation time is in need.

A Study on the Space Zoning and Area Composition of the Operation Department in Regional Public Hospitals - Focused on Net Floor Area (지방의료원 수술부 영역 및 면적 구성에 관한 조사·분석연구 - 순면적을 중심으로)

  • Yun, Woo Yong;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.25-36
    • /
    • 2019
  • Purpose: To establish guidelines for local public hospitals, the survey was conducted primarily on the current status of local public hospitals, focusing on the zone configuration and the spatial area of the operating department. Methods: 3 Methods have been used in this paper. 1) Analyzing drawings to derive the net floor area of each room. 2) A literature survey about composition of the zone by infection control. 3) Observation survey for user circulation analysis. Results: The operation department consists of the major, secondary, support and connected zones according to the user's actions. The spatial area composition ratio for each zone is major zone: 41.79%, secondary zone: 10.87%, support zone: 23.10%, and connected zone: 24.24%. Implications: This study is a basic research for guideline for the operation department in local public hospitals. In this study, zones configuration of the operation departments are classified in terms of user actions and room functions. In the future, it is required to establish criteria considering infection control and copper connection aspects.