• Title/Summary/Keyword: The City Structures

Search Result 613, Processing Time 0.027 seconds

Comparative Study About the Features of the Japanese Green Area Policy Changes - In Case of the Urban Green Area Law and Urban Park Law Amended in 2004 - (일본의 녹지정책 변화 특성에 관한 비교 연구 - 2004년 개정된 도시녹지법과 도시공원법을 중심으로 -)

  • Kang, Myung-Soo;Sung, Hyun-Chan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.2
    • /
    • pp.65-75
    • /
    • 2005
  • A green area plan is getting attention as a way to solve the recent urban problems such as the rise of environment problems. To correspond to this change, there were dramatic amendments for the green area related laws. These amendments are appraised as the epochal turning point for the green area policies. This study is to introduce the main contents of amended urban green area law and urban park law in Japan, to compare with the Korean green area related laws, and to summarize the special features of both countries' green policies and the comments about the Korean green area policy structures. As a result, this amendment of Japan established the unified green area policy structure supporting the green area policies of municipal governments and is inducing living environment improvement by securing green area in the center of city, support, and the participation of residents. On the other hands, this amendment of Korea is a lack of the systemization of green area policy and the phased establishments of green area plan in spite of the scope of whole city because of absence of the unified high level plan.

Field monitoring of wind effects on a super-tall building during typhoons

  • Zhi, Lunhai;Li, Q.S.;Wu, J.R.;Li, Z.N.
    • Wind and Structures
    • /
    • v.14 no.3
    • /
    • pp.253-283
    • /
    • 2011
  • This paper presents the field measurement results of wind effects on a super-tall building (CITIC Plaza, 391 m high) located in Guangzhou. The field data such as wind speed, wind direction and acceleration responses were simultaneously and continuously recorded from the tall building by a wind and vibration monitoring system during two typhoons. The typhoon-generated wind characteristics including turbulence intensity, gust factor, peak factor, turbulence integral length scale and power spectral density of fluctuating wind speed were presented and discussed. The dynamic characteristics of the tall building were determined based on the field measurements and compared with those calculated from a 3D finite element model of the building. The measured natural frequencies of the two fundamental sway modes of the building were found to be larger than those calculated. The damping ratios of the building were evaluated by the random decrement technique, which demonstrated amplitude-dependent characteristics. The field measured acceleration responses were compared with wind tunnel test results, which were found to be consistent with the model test data. Finally, the serviceability performance of the super-tall building was assessed based on the field measurement results.

Vibration based energy harvesting performance of magneto-electro-elastic beams reinforced with carbon nanotubes

  • Arjun Siddharth Mangalasseri;Vinyas Mahesh;Sriram Mukunda;Vishwas Mahesh;Sathiskumar A Ponnusami;Dineshkumar Harursampath;Abdelouahed Tounsi
    • Advances in nano research
    • /
    • v.14 no.1
    • /
    • pp.27-43
    • /
    • 2023
  • This article investigates the energy harvesting characteristics of a magneto-electro-elastic (MEE) cantilever beam reinforced with carbon nanotubes (CNT) under transverse vibration. To this end, the well-known lumped parameter model is used to represent the coupled multiphysics problem mathematically. The proposed system consists of the MEE-CNT layer on top and an inactive substrate layer at the bottom. The substrate is considered to be made of either an isotropic or composite material. Basic laws such as Gauss's Law, Newton's Law and Faraday's Law are used to arrive at the governing equations. Surface electrodes across the beam are used to harvest the electric potential produced, together with a wound coil, for the generated magnetic potential. The influence of various distributions of the CNT and its volume fraction, substrate material, length-to-thickness ratio, and thickness ratio of substrate to MEE layer on the energy harvesting behaviour is thoroughly discussed. Further, the effect of external resistances and changes in substrate material on the response is analysed and reported. The article aims to explore smart material-based energy harvesting systems, focusing on their behaviour when reinforced with carbon nanotubes. The results of this study may lead to an improved understanding of the design and analysis of CNT-based smart structures.

Effects of size-dependence on static and free vibration of FGP nanobeams using finite element method based on nonlocal strain gradient theory

  • Pham, Quoc-Hoa;Nguyen, Phu-Cuong
    • Steel and Composite Structures
    • /
    • v.45 no.3
    • /
    • pp.331-348
    • /
    • 2022
  • The main goal of this article is to develop the finite element formulation based on the nonlocal strain gradient and the refined higher-order deformation theory employing a new function f(z) to investigate the static bending and free vibration of functionally graded porous (FGP) nanobeams. The proposed model considers the simultaneous effects of two parameters: nonlocal and strain gradient coefficients. The nanobeam is made by FGP material that exists in un-even and logarithmic-uneven distribution. The governing equation of the nanobeam is established based on Hamilton's principle. The authors use a 2-node beam element, each node with 8 degrees of freedom (DOFs) approximated by the C1 and C2 continuous Hermit functions to obtain the elemental stiffness matrix and mass matrix. The accuracy of the proposed model is tested by comparison with the results of reputable published works. From here, the influences of the parameters: nonlocal elasticity, strain gradient, porosity, and boundary conditions are studied.

Effect of reinforcing details on seismic behavior of RC exterior wide beam-column joint

  • Jae Hyun Kim;Seung-Ho Choi;Sun-Jin Han;Hoseong Jeong;Jae-Yeon Lee;Kang Su Kim
    • Earthquakes and Structures
    • /
    • v.25 no.4
    • /
    • pp.283-296
    • /
    • 2023
  • This paper presents experimental and numerical studies of seismic performance on reinforced concrete (RC) wide beam (WB) joints. Two RC-WB joint specimens and one conventional RC joint specimen were fabricated using the reinforcing details of longitudinal reinforcing bars in a beam as a variable, and quasi-static cyclic loading tests were performed. The results were used to compare and analyze the load-drift ratio relationship, failure mode, and seismic performance of the specimens quantitatively. In addition, a finite element (FE) analysis of the RC-WB joint was conducted, and the rationality of the FE model was validated by comparing it with the test results. Based on the FE model, a parametric study was conducted, where the ratio of longitudinal reinforcing bars placed on the outer and inner parts of the joint (𝜌ex/𝜌in) was a key variable. The results showed that, in the RC-WB joint, an increase of 𝜌ex/𝜌in leads to more severe damage to concrete, which reduces the seismic performance of the RC-WB joints.

Wind effects on a large cantilevered flat roof: loading characteristics and strategy of reduction

  • Fu, J.Y.;Li, Q.S.;Xie, Z.N.
    • Wind and Structures
    • /
    • v.8 no.5
    • /
    • pp.357-372
    • /
    • 2005
  • Mean and extreme pressure distributions on a large cantilevered flat roof model are measured in a boundary layer wind tunnel. The largest peak suction values are observed from pressure taps beneath conical "delta-wing type" corner vortices that occur for oblique winds, then the characteristics and causes of the local peak suctions are discussed in detail. Power spectra of fluctuating wind pressures measured from some typical taps located at the roof edges under different wind directions are presented, and coherence functions of fluctuating pressures are also obtained. Based on these results, it is verified that the peak suctions are highly correlated with the conical vortices. Furthermore, according to the characteristics of wind loads on the roof, an aerodynamic solution to minimize the peak suctions by venting the leading edges and the corners of the roof is recommended. The experimental results show that the suggested strategy can effectively control the generation of the conical vortices and make a reduction of 50% in mean pressures and 25% in extreme local pressures at wind sensitive locations on the roof.

Observational study of wind characteristics from 356-meter-high Shenzhen Meteorological Tower during a severe typhoon

  • He, Yinghou;Li, Qiusheng;Chan, Pakwai;Zhang, Li;Yang, Honglong;Li, Lei
    • Wind and Structures
    • /
    • v.30 no.6
    • /
    • pp.575-595
    • /
    • 2020
  • The characteristics of winds associated with tropical cyclones are of great significance in many engineering fields. This paper presents an investigation of wind characteristics over a coastal urban terrain based on field measurements collected from multiple cup anemometers and ultrasonic anemometers equipped at 13 height levels on a 356-m-high meteorological tower in Shenzhen during severe Typhoon Hato. Several wind quantities, including wind spectrum, gust factor, turbulence intensity and length scale as well as wind profile, are presented and discussed. Specifically, the probability distributions of fluctuating wind speeds are analyzed in connection with the normal distribution and the generalized extreme value distribution. The von Karman spectral model is found to be suitable to depict the energy distributions of three-dimensionally fluctuating winds. Gust factors, turbulence intensity and length scale are determined and discussed. Moreover, this paper presents the wind profiles measured during the typhoon, and a comparative study of the vertical distribution of wind speeds from the field measurements and existing empirical models is performed. The influences of the topography features and wind speeds on the wind profiles were investigated based on the field-measured wind records. In general, the empirical models can provide reasonable predictions for the measured wind speed profiles over a typical coastal urban area during a severe typhoon.

A Study on the Right of Light Impact at Adjacent Residential Area by High-rise Residential Commercial Complex Building (상업지역내 고층건물의 인접주거 지역 일조권 영향에 관한 연구)

  • Lee, Sang-Hwa;Lee, Kyoo-Seock
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.2
    • /
    • pp.10-18
    • /
    • 2009
  • In order to determine the violation of right of light impact at adjacent residential area by high-rise building, analysis on the right of light for high-rise residential commercial complex building block at Gahngnam-ku, Seoul, Korea was carried out using Google Sketchup Pro. After the analysis th sunshine duration of B apartment decreased from 5 hours 16 minutes 3 hours 48 minutes by I hour 42 minutes after construction. It shows that the total sunshine duration is less than the Seoul City Government Standard which is more than 4 hours a day, or more than 2 consecutive hours. Lowering the heights of apartments by 54m would increase the total sunshine duration which would meet the Seoul City Government Standard by four hours seven minutes. Problems that rna lead to the violation on the right of light in the adjacent area should be discussed in advance and minimized by analyzing the right of light among buildings and structures which are scheduled to be constructed on the site during construction penni! process when high-rise building is proposed.

4th Industrial Revolution Construction IT Convergence Technology Based Bridge System CFT for Seismic Performance Improvement and Performance Evaluation of Buildings Using Drones (4차산업혁명 건설IT융합기술기반 내진성능향상을 위한 Bridge System CFT 개발 및 드론을 이용한 건축물 성능검토)

  • Kim, Dae-Geon;Jang, Yu-Gyeong;Moon, Won-Kyu;Lee, Da-Sol;Park, Su-Bin;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.177-178
    • /
    • 2018
  • Unlike the projects that the government has implemented recently to develop new cities under the New Deal project, Saeddeul Village projects to improve the environment of the city are gaining attention. The problem has been found to be that many of the buildings in Saeddeul Village are still not earthquake-proof by using drones to review the state of the town. It also revealed that after two years of earthquakes, Pilotis structures are the most vulnerable to earthquakes. However, it is suitable for small spaces in the city because it provides parking spaces as well as residential spaces. Accordingly, the focus should be on repair and reinforcement rather than reconstruction. In this study, a concrete-based seismic design and construction method is developed in the columns of the existing pylotis structure.

  • PDF

CFD Simulations of the Ground Surface Temperature and Air Temperature, Air flow Coupled with Solar Radiation (태양복사열에 따른 지표면 온도와 열, 기류 환경 시뮬레이션 연구)

  • Lee, JuHee;Kim, JaeGwon;Yoon, JaeOck
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.65-70
    • /
    • 2014
  • The thermal environment in a small city rapidly deteriorates due to the urbanization and overpopulation. It is important to understand and predict the thermal environment in a city area. The thermal environment is highly affected by the solar radiation and temperature distributions changing over time periodically. To predict the thermal environment precisely, the solar radiation calculation including radiation strength, incidence angle, and thermal radiation between building surface and ground should be considered. In this study, the computational domain includes various artificial structures such as building, ground, asphalt, brick and grass. To consider the solar radiation, the unsteady state numerical calculation is performed from sun rise to mid-day (2:00pm). The numerical methods consist of solar load and one dimensional heat conduction through the boundaries to reduce the computational load and improve the flexibility of the calculation.