• 제목/요약/키워드: The 10-second test

검색결과 4,996건 처리시간 0.034초

A Jarque-Bera type test for multivariate normality based on second-power skewness and kurtosis

  • Kim, Namhyun
    • Communications for Statistical Applications and Methods
    • /
    • 제28권5호
    • /
    • pp.463-475
    • /
    • 2021
  • Desgagné and de Micheaux (2018) proposed an alternative univariate normality test to the Jarque-Bera test. The proposed statistic is based on the sample second power skewness and kurtosis while the Jarque-Bera statistic uses sample Pearson's skewness and kurtosis that are the third and fourth standardized sample moments, respectively. In this paper, we generalize their statistic to a multivariate version based on orthogonalization or an empirical standardization of data. The proposed multivariate statistic follows chi-squared distribution approximately. A simulation study shows that the proposed statistic has good control of type I error even for a very small sample size when critical values from the approximate distribution are used. It has comparable power to the multivariate version of the Jarque-Bera test with exactly the same idea of the orthogonalization. It also shows much better power for some mixed normal alternatives.

중풍 환자의 상지 경직에 대한 봉약침의 효과 (Effect of Bee-venom Acupuncture on Upper Limb Spasticity of Stroke Patients)

  • 노주환;박정아;조성우;윤현민;장경전;송춘호;안창범;김철홍
    • Journal of Acupuncture Research
    • /
    • 제27권4호
    • /
    • pp.115-125
    • /
    • 2010
  • Objectives : The purpose of this study is to determine the effect of Bee-venom Acupuncture on upper limb spasticity control in stroke patients. Methods : Ten stroke patients with upper limb spasticity were randomly divided into two groups, a Bee-Venom Acupuncture group(group I) and a normal saline group(group II). After 1 week resting phase, this trial was used a cross-over trial. The numbers of Pharmacopuncture treatment were 3 times a week for 3 weeks. Modified Ashworth Scale(MAS), WMFT(Wolf Motor Function Test), The 10-second Test were used for evaluation of spasticity control before experiment, after 1 week, 2 weeks, 3 weeks. Results : Group I showed significant improvement(p<.05) in MAS, WMFT, The 10-second Test. But Group II showed no significant improvement(p<.05) in MAS, WMFT, The 10-second Test. The results showed significant difference in WMFT, The 10-second Test, but no significant difference in MAS between two groups. Conclusions : These results showed that Bee-venom Acupuncture might decrease upper limb spasticity and increase arm motor function in stroke patients. Further studies will be required to examine more cases in the long period for the effect on upper limb in spasticity by Bee-Venom Acupuncture.

Long-term safety of PEG 4000 in children with chronic functional constipation: A biochemical perspective

  • Bae, Sun-Hwan
    • Clinical and Experimental Pediatrics
    • /
    • 제53권7호
    • /
    • pp.741-744
    • /
    • 2010
  • Purpose: To evaluate the long-term safety of polyethylene glycol (PEG) 4000 in children with constipation, particularly the biochemical aspects of safety. Methods: Medical records were evaluated, and 100 children, who had been taking PEG 4000 for more than 6 months, and who had been under clinical and biochemical monitoring, were enrolled. Ages; $6.11{\pm}3.12$ years, Duration of therapy; $16.93{\pm}7.02$ months, dose of PEG 4000; $0.72{\pm}0.21g/kg/d$. Results: None of the children complained of clinical adverse effect. The first biochemical test was performed at 8.05 months after beginning of PEG 4000. Serum phosphate (SP) value was high in 10 children, and leucopenia was noted in one child. The second test was performed in 44 children at 7.57 months after the first test. The SP value was high in four children, including the three children whose initial SP value was high and one new child. Six out of 10 children with high initial SP value became normal and one was lost. Hypernatremia was noted in one child. The third test was done in 15 children at 7.5 months after the second test. The SP value of the new child from the second test was high, but became normal after finishing treatment. Two out of 3 children with high SP value at the second test became normal and one was lost. The fourth test was done in 2 children few months after the third test. All of the results were normal. There were no relation between duration of therapy and hyperphosphatemia, or between dose of PEG 4000 and hyperphosphatemia. Conclusions: PEG 4000 is safe for long-term therapy in children with constipation with respect to biochemical parameters.

A modified test for multivariate normality using second-power skewness and kurtosis

  • Namhyun Kim
    • Communications for Statistical Applications and Methods
    • /
    • 제30권4호
    • /
    • pp.423-435
    • /
    • 2023
  • The Jarque and Bera (1980) statistic is one of the well known statistics to test univariate normality. It is based on the sample skewness and kurtosis which are the sample standardized third and fourth moments. Desgagné and de Micheaux (2018) proposed an alternative form of the Jarque-Bera statistic based on the sample second power skewness and kurtosis. In this paper, we generalize the statistic to a multivariate version by considering some data driven directions. They are directions given by the normalized standardized scaled residuals. The statistic is a modified multivariate version of Kim (2021), where the statistic is generalized using an empirical standardization of the scaled residuals of data. A simulation study reveals that the proposed statistic shows better power when the dimension of data is big.

화학레이저 구동용 이젝터 시스템 개발 (II) - 이차목 형태의 환형 초음속 이젝터 최적 설계 - (Development of an Ejector System for Operation of Chemical Lasers (II) - Optimal Design of the Second-Throat Type Annular Supersonic Ejector -)

  • 김세훈;진정근;권세진
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1231-1237
    • /
    • 2004
  • Determination of geometric design parameters of a second-throat type annual supersonic ejector is described. Tested geometric parameters were primary nozzle area ratio, cross-sectional area of second-throat, L/D ratio of second-throat and primary flow injection angle. Varying these four geometric parameters, we build a test matrix made of 81 test conditions, and experimental apparatus was fabricated to accommodate them. For each test condition, the stagnation pressure of primary flow and the static pressure of the secondary flow were measured simultaneously along with their transition to steady operation and finally to unstarting condition. Comparing the performance curve of every case focused on starting pressure, the unstarting pressure and the minimum secondary pressure, we could derive correlations that the parameters have on the performance of the ejector and presented the optimal design method of the ejector. Additional experiments were carried out to find effects of temperature and mass flow rate of the secondary flow.

보바스 개념에 기초한 슬링 운동이 양하지 뇌성마비 균형에 미치는 영향: 단일사례연구 (The Effects of Sling Exercise Based with Bobath Concept on the Balance of Spastic Diplegia Cerebral Palsy: Case Report)

  • 이은주
    • 신경치료
    • /
    • 제22권3호
    • /
    • pp.11-18
    • /
    • 2018
  • Purpose This study is to investigate the effect of sling exercise on the balance capacity of spastic diplegia cerebral palsy patient based on Bobath concept. Methods A single subject experiment was designed targeting an 8year old child with the rigid bilateral cerebral palsy. The static balance test used the 30 second Rombug test of BT4, and the dynamic balance test used the timed up and go test. Results In the 30second Rombug test of BT4, the child had a smaller median outcome than baseline and withdrawal period. In the TUG test, the walking speed in the intervention period was improved comparing to the baseline and withdrawal period. Conclusion The sling exercise based on the Bobath concept has been proved that it is an effective intervention to improve the static and dynamic balance capacity of patients with rigid bilateral cerebral palsy.

3온스 물 삼킴검사 이후 정상 노년층의 음질 변화: 음향학적 분석 (Voice quality of normal elderly people after a 3oz water-swallow test: An acoustic analysis)

  • 이솔희;최홍식;최성희;김향희
    • 말소리와 음성과학
    • /
    • 제10권2호
    • /
    • pp.69-76
    • /
    • 2018
  • The elderly are at increased risk of developing dysphagia due to aging and illnesses. The aim of the current study was to analyze, via an acoustic study, the change in the voice quality of normal elderly people after a 3oz water-swallow test. Subjects included a group of 60 normal elderly people (age: $mean{\pm}SD=76.9{\pm}6.66$) and 60 healthy young adults (age: $mean{\pm}SD=25.1{\pm}2.36$). Every participant produced a five-second /a/ phonation pre- and post-swallowing, and the fractioned two-second sections were analyzed using the MDVP (multi dimensional voice program) analysis. The elderly group demonstrated a post-swallowing increase in the following related acoustic parameters: fundamental frequency, fundamental frequency variation, amplitude-variation, and noise in both two-second sections. However, the younger group showed an increase only in frequency related acoustic parameters (i.e., STD ) in the first two-second section. The significant changes in values in the post-swallowing parameters might indicate temporary irregularities in pitch and amplitude along with higher amounts of noise in the voice. The results could be attributed to water residues in the vocal fold and vocal tract, as well as a deterioration of the motor and sensory functions caused by anatomical and physiological changes that result from aging.

듀얼카메라를 활용한 ACC 안전성 평가 방법에 관한 연구 (A Study on the ACC Safety Evaluation Method Using Dual Cameras)

  • 김봉주;이선봉
    • 자동차안전학회지
    • /
    • 제14권2호
    • /
    • pp.57-69
    • /
    • 2022
  • Recently, as interest in self-driving cars has increased worldwide, research and development on the Advanced Driver Assist System is actively underway. Among them, the purpose of Adaptive Cruise Control (ACC) is to minimize the driver's driving fatigue through the control of the vehicle's longitudinal speed and relative distance. In this study, for the research of the ACC test in the real environment, the real-road test was conducted based on domestic-road test scenario proposed in preceding study, considering ISO 15622 test method. In this case, the distance measurement method using the dual camera was verified by comparing and analyzing the result of using the dual camera and the result of using the measurement equipment. As a result of the comparison, two results could be derived. First, the relative distance after stabilizing the ACC was compared. As a result of the comparison, it was found that the minimum error rate was 0.251% in the first test of scenario 8 and the maximum error rate was 4.202% in the third test of scenario 9. Second, the result of the same time was compared. As a result of the comparison, it was found that the minimum error rate was 0.000% in the second test of scenario 10 and the maximum error rate was 9.945% in the second test of scenario 1. However, the average error rate for all scenarios was within 3%. It was determined that the representative cause of the maximum error occurred in the dual camera installed in the test vehicle. There were problems such as shaking caused by road surface vibration and air resistance during driving, changes in ambient brightness, and the process of focusing the video. Accordingly, it was determined that the result of calculating the distance to the preceding vehicle in the image where the problem occurred was incorrect. In the development stage of ADAS such as ACC, it is judged that only dual cameras can reduce the cost burden according to the above derivation of test results.

Economic Reliability Group Acceptance Sampling Based on Truncated Life Tests Using Pareto Distribution of the Second Kind

  • Aslam, Muhammad;Mughal, Abdur Razzaque;Hanif, Muhammad;Ahmad, Munir
    • Communications for Statistical Applications and Methods
    • /
    • 제17권5호
    • /
    • pp.725-731
    • /
    • 2010
  • Economic Reliability test plans(ERTP) are proposed considering that the life time of the submitted items follow the Pareto distribution of the second kind. For various specified acceptance number, sample size and producer's risk, a minimum test termination time is obtained. A comparison of proposed plan has been made with the existing plan developed by Aslam et al. (2010). The results are explained by tables and example.

How Does 12-weeks of Taekwondo Training Effect Older Persons' Functional Fitness: A Preliminary Study

  • Daniel Sullivan;Mike Climstein;Ben Exton;Luke Delvecchio
    • 대한물리의학회지
    • /
    • 제19권1호
    • /
    • pp.1-10
    • /
    • 2024
  • PURPOSE: This pre-post intervention study aimed to examine the effects of a 12-week supervised modified Taekwondo exercise program on the functional fitness of community-dwelling older adults. METHODS: 10 participants (mean age: 72.3 ± 4.6 years) completed the program over a 12-week period. The intervention consisted of Taekwondo-based exercises modified for older persons. Changes to functional fitness were measured using the finger-to-nose test, functional reach test, timed up and go test, 30-second sit-to-stand test, 30-second arm curl test, Chester step test, chair sit-and-reach test, and back scratch test. Participants were assessed prior to the training and after the final training session, changes were measured using descriptive statistics and paired sample 't' tests. RESULTS: Effect sizes ranged from small to large (Cohen's d = .22 to 1.23). The exercise program was well- tolerated by participants, with a high level of engagement and no attrition for the duration of the program. Results showed significant improvements in most measures of functional fitness (p < .05) except for the back scratch test (p = .051). CONCLUSION: These findings suggest a well-designed, supervised, modified Taekwondo exercise program can significantly improve functional fitness in older adults.