• Title/Summary/Keyword: Thallium-201 SPECT

Search Result 32, Processing Time 0.034 seconds

Functional Significance of Angiographic Collaterals in Patients with Totally Occluded Right Coronary Artery: Intracoronary Thallium-201 Scintigraphy (우측 관상동맥 폐쇄 환자에서 관상동맥내 Thallium-201 주사를 이용한 측부 혈행의 의의)

  • Lee, Do-Yun;Lee, Jong-Doo;Cho, Seung-Yun;Shim, Won-Heum;Ha, Jong-Won;Kim, Han-Soo;Kwon, Hyuk-Moon;Jang, Yang-Soo;Chung, Nam-Sik;Kim, Sung-Soon;Park, Chang-Yun;Kim, Young-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.210-217
    • /
    • 1993
  • To compare the myocardial viability in patients suffering from total occlusion of the right coronry artery (RCA) with the angiographic collaterals, intracoronary injection of Thallium-201 (T1-201) was done to 14 coronary artery disease (CAD) patients (pts) with total occlusion of RCA and into four normal subjects for control. All 14 CAD pts had Grade 2 or 3 collateral circulations. There were 14 male and 4 females, and their ages ranged from 31 to 70 years. In nine pts, T1-201 was injected into left main coronary artery (LCA) ($300{\sim}350{\mu}Ci$) to evaluate the myocardial viability of RCA territory through collateral circulations. The remaining five pts received T1-201 into RCA ($200{\sim}250{\mu}Ci$) because two had intraarterial bridging collaterals and three had previous successful PTCA. Planar & SPECT myocardial perfusion images were obtained 30 minutes, and four to five hours after T1-201 injection. Intravenous T1-201 reinjection (six pts) or $^{99m}Tc-MIBI$ (two pts) were also performed in eight CAD pts. Intracoronary myocardial perfusion images were compared with intravenous T1-201 (IV T1-201) images, ECG, and ventriculography. Intracoronary T1-201 images proved to be superior to that of IV T1-201 due to better myocardial to background uptake ratio and more effective in the detection of viable tissue. We also found that perfusion defects were smaller on intracoronary T1-201 images than those on the IV T1-201. All of the 14 CAD pts had either mostly viable myocardium (seven pts) or large area of T1-201 perfusion (seven pts) in RCA territory, however ventriculographic wall motion and ECG did not correlate well with intracoronary myocardial perfusion images. In conclusion, total RCA occlusion patients with well developed collateral circulation had large area of viable myocardial in the corresponding territory.

  • PDF

Evaluation of Glioma with Thallium-201 Brain SPECT: The Correlation with $^1H$ MR Spectroscopy and Pathology ($^{201}Tl$ 뇌 SPECT을 이용한 신경교종의 평가)

  • Sohn, Hyung-Sun;Kim, Euy-Neyng;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Yong-An;Chung, Soo-Kyo;Hong, Yong-Gil;Lee, Youn-Soo;Choe, Bo-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.465-477
    • /
    • 2000
  • Purpose: Thallim-201 ($^{201}Tl$) brain SPECT and proton ($^1H$) magnetic resonance spectroscopy (MRS) have been used to evaluate tumor grade and viability of glioma. We assessed the correlations between $^{201}Tl$ brain index or spectrum of metabolites of $^1H$ MRS and grade of glioma or histopathologic findings. Materials and Methods: We studied 17 patients (4 astrocytoma, 7 anaplastic astrocytoma and 6 glioblastoma). On $^{201}Tl$ Brain SPECT, $^{201}Tl$ index was measured as the ratio of average counts for region of interest to those for the contralateral normal brain. On $^1H$ MRS, we calculated choline (Cho) /creatine (Cr) ratio and N-acetylaspartate (NAA)/Cr ratio in ROI defined as tumor center. Histopathologic findings were graded by Ki-67 index, cellularity, mitosis, pleomorphism, necrosis and endothelial proliferation. An unpaired t test and statistical correlations were performed to evaluate these data. Results: Tl-index showed the best correlation with Ki-67 index (p<0.01), less correlations with cellularity, mitosis, and endothelial proliferation, but no correlation with results of MRS, pleomorphism, or necrosis. The findings of MRS did not correlate with all of the above. The cases of glioblastoma demonstrated a higher Tl-index, Cho/cr ratio, Ki-67 index and lower NAA/Cr ratio, albeit without statistical significance. Conclusion: Even though $^{201}Tl$ brain SPECT did not correlate directly with grade of malignancy, it may still be useful in determining biological aggressiveness of tumor and prognosis of patients because it correlated well with Ki-67 index, a growth fraction of glioma, cellularity, mitosis and endothelial proliferation.

  • PDF

Protocols of Myocardial Perfusion SPECT (심장관류SPECT 검사 프로토콜)

  • Kim, Seong-Min
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.82-86
    • /
    • 2005
  • In myocardial perfusion scintigraphy, the results of this evalution now confront the practitioner of nuclear medicing with methodologic options. Most nuclear cardiologic studies are performed using thallium-201, Tc-99m sestamibi and Tc-99m tetrofosmin. Some part of these studies use some form of pharmacologic stress test. While tailoring each test to the individual is ideal, this may be impractical for a busy department. Accordingly, established protocols to be used for patients with similar clinical presentations will be helpful. The following review presents methodology of various imaging protocols mainly according to the guidelines of nuclear cardiology procedures in American Society of Nuclear Cardiology.

Diagnostic Accuracy of Rest T1-201/Stress Tc-99m-MIBI Myocardial SPECT in the Diagnosis of Coronary Artery Disease (휴식 T1-201/부하 Tc-99m MIBI 심근 SPECT의 관상동맥질환 진단 정확성)

  • Yeo, Jeong-Seok;Lee, Dong-Soo;Kang, Keon-Wook;Sohn, Dae-Won;Oh, Byung-Hee;Lee, Myung-Mook;Chung, June-Key;Park, Young-Bae;Lee, Myung-Chul;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.112-117
    • /
    • 1996
  • Objective: Standard stress/rest Tc-99m MIBI and T1-201 myocardial perfusion study have some limitations such as stress/rest image overlap for Tc-99m-MIBI, low energy for T1-201 and long period of study time for two separate studies. Separate acquisition rest T1-201/stress Tc-99m MIBI dual isotope study is a potentially efficient myocardial perfusion imaging protocol that combines the high resolution of Tc-99m for stress perfusion assessment and T1-201 for viability assessment. This study assessed the usefulness and diagnostic accuracy for this new approach. Methods: We tried to evaluate sensitivity and specificity of dual isotope separate acquisition protocol in 67 patients. Immediately after resting T1-201 SPECT data was acquired, dipyridamole stress Tc-99m MIBI myocardial perfusion study was performed. Visual analysis was carried out qualitatively with 0 to 3 scoring system for 17 segments of left ventricle in the reconstructed horizontal long axis and short axis slices. Results: Total study was completed within 3 hours. In angiographic correlation, dual isotope SPECT demonstrated high sensitivity(85%) and in a small group of patients, high specificity was also observed (100%). Conclusion: Combined thallium-201/stress Tc-99m MIBI SPECT displayed similiar diagnostic accuracy to protocol using stress/rest Tc-99m MIBI SPECT. This protocol was completed in shorter period than the previous protocols and therefore enhance laboratory throughput and patients convenience.

  • PDF

Usefulness of $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT in Benign and Malignant Lesion of the Lungs (폐의 양성 및 악성 병변에서 $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT의 진단적 가치)

  • Kim, Seong-Suk;Kim, Ki-Beom;Cho, Young-Bok;Cho, In-Ho;Lee, Kyung-Hee;Chung, Jin-Hong;Lee, Hyoung-Woo;Lee, Kwan-Ho;Lee, Hyun-Woo;Kim, Mi-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.54-62
    • /
    • 1996
  • Background: $^{99m}Tc$ MIBI(Methoxyisobutylisonitrile complex), a member of the isonitrile class of coordination compounds, is a lipophilic cation presently under investigation for clinical use as myocardial perfusion imaging agent and is widely used to detect myocardial infarction. Preliminary reports indicate that $T_1$-201 accumulate in human neoplasm and several authors reported $^{99m}Tc$ MIBI may also localized in primary malignant tumor and metastatic deposits from lung cancer. We evaluated the uptake of $^{99m}Tc$ MIBI in lung cancer and localization of mediastinal and other site metastasis, and compared the benign lesion of the lung. Method: Thirty four patients of lung cancer and ten patients of benign lung lesion were studied with chest CT and $^{99m}Tc$ MIBI Lung SPECT. $^{99m}Tc$ MIBI uptake ratio was assessed by TR/NL(Lung lesion/ Normal area), HT/NL (Heart/Normal area) and HT/TR(Heart/Lung lesion). Results: 1) All lung cancer patients showed increased uptakes of $^{99m}Tc$ MIBI in malignant lung lesion and Tc-99m MIBI uptake was also increased in mediastinal and lymph node metastasis except two cases. 2) There was significant different ratio of TR/NL between malignant and benign lesion, $3.79{\pm}1.82$ and $1.67{\pm}0.63$ on planar images, respectively(p<0.001). 3) There was no significant difference of $^{99m}Tc$ MIBI uptake ratio between squamous cell carcinoma, small cell carcinoma and adeno carcinoma($3.64{\pm}1.66$, $3.57{\pm}0.72$, $4.31{\pm}2.28$ respectively). Conclusion: $^{99m}Tc$ MIBI lung SPECT was useful in the localization of tumor and mediastinal or other site metastatic lesion in lung cancer and also in the differential diagnosis between benign and malignant lesion.

  • PDF

The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT (심근관류 SPECT에서 움직임 보정 방법들의 비교)

  • Park, Jang-Won;Nam, Ki-Pyo;Lee, Hoon-Dong;Kim, Sung-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose Patient motion during myocardial perfusion SPECT can produce images that show visual artifacts and perfusion defects. This artifacts and defects remain a significant source of unsatisfactory myocardial perfusion SPECT. Motion correction has been developed as a way to correct and detect the patient motion for reducing artifacts and defects, and each motion correction uses different algorithm. We corrected simulated motion patterns with several motion correction methods and compared those images. Materials and Methods Phantom study was performed. The anthropomorphic torso phantom was made with equal counts from patient's body and simulated defect was added in myocardium phantom for to observe the change in defect. Vertical motion was intentionally generated by moving phantom downward in a returning pattern and in a non-returning pattern throughout the acquisition. In addition, Lateral motion was generated by moving phantom upward in a returning pattern and in a non-returning pattern. The simulated motion patterns were detected and corrected similarly to no-motion pattern image and QPS score, after Motion Detection and Correction Method (MDC), stasis, Hopkins method were applied. Results In phantom study, Changes of perfusion defect were shown in the anterior wall by the simulated phantom motions, and inferior wall's defect was found in some situations. The changes derived from motion were corrected by motion correction methods, but Hopkins and Stasis method showed visual artifact, and this visual artifact did not affect to perfusion score. Conclusion It was confirmed that motion correction method is possible to reduce the motion artifact and artifactual perfusion defect, through the apply on the phantom tests. Motion Detection and Correction Method (MDC) performed better than other method with polar map image and perfusion score result.

  • PDF

A Study on Optimal Myocardium Perfusion SPECT According to Possible Myocardial Infarct Sites (8) 예측성 경색 부위별 최적의 심근관류 단층촬영술 시행에 관한 연구)

  • Song Jae Beom;Lee Wan Kyu;Shu Myung Duk;Jang Sang Sup
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.25 no.1
    • /
    • pp.234-252
    • /
    • 1999
  • Purpose : Physical properties of radiophamaceuticals of technetium($^{99m}Tc$) and thallium($^{201}Tl$) have early been used for clinical diagnostics. The studies of those radiophamaceuticals have been contributed to the efficient to

  • PDF