• Title/Summary/Keyword: Thallium-201

Search Result 68, Processing Time 0.035 seconds

Lung/Heart Uptake Ratio and Transient Dilation Ratio of the Left Ventricle During Thallium-201 Imaging with Dipyridamole (Dipyridamole 부하를 T1-201 심근스캔에서 폐/심장 섭취율과 일과성 좌심실 확장율에 관한 연구)

  • Lee, Jae-Tae;Chung, Byung-Chun;Kim, Sang-Hyun;Lee, Kyu-Bo;Chae, Sung-Chull
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.177-185
    • /
    • 1991
  • Dipyridamole thallium imaging is one of the most widely accepted means of evaluating patients with suspected or known coronay artery disease. The results of thallium imaging help diagnose coronary artery disesse (CAD), determine the hemodynamic significance of coronary stenosis, evaluate viability of myocardium, assess the outcome of therapeutic interventions and stratify patients according to their risk for luther cardiac events. An increased lung thallium uptake and transient LV dilation has been reported as poor prognostic indicator and associated with extensive and severe coronary artery disease. We quantitated lung/heart uptake ratio (l/HUR) and transient left ventricular dilation ratio in 44 patients and 17 controls undertaking dipyridamole thallium-201 scintigraphy. The results are as follows: 1) The lung/heart uptake ratio was high in patients with CAD and which became higher according to increasing number of diseased vessel. The L/HUR of patients with low LVEF (<35%) was lower than those with normal LVEF. 2) Transient left ventricular dilation ratio of CAD patients had no close relation between numbers of diseased vessels and was not higher than normals. But transient left ventricular dilation ratio of patients with myocardial infartion was higher than normals. We concluded that lung/heart uptake ratio seems to be sensitive marker for severity of CAD and myocardial function, but transient left ventricular dilation ratio alone is not sufficient to be a marker for severe and extensive CAD.

  • PDF

Usefulness of Thallium Scan for Differential Diagnosis of Breast Mass (유방 종괴의 감별진단을 위한 탈륨 스캔의 유용성)

  • Bae, Sang-Kyun;Yum, Ha-Yong;Lee, Chung-Han;Choi, Kyung-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.214-219
    • /
    • 1994
  • The purpose of this study is to evaluate thallium scanning as a potential test in differentiating malignant from benign lesions of breast. Thirty-one female patients underwent thallium scan of the breast. After intravenous injection of 74-111 MBq(2-3 mCi)of thallium-201, anterior and lateral images were obtained. We compared thallium scans with pathological results. Of 11 patients with breat cancers, 10 cases(90.9%) were detected using thallium scan. Thallium scan obtained in one patient who had breast cancer but received several cycles of chemotherapy did not show thallium uptake. The smallest detectable cancer was 1.5cm in diameter. In contrast, there is no thallium accumulation in breasts of 17 of 20 patients with benign disease(85%). Three cases of 13 fibrocystic disease show thallium uptake in their breast. In conclusion, thallium scan is an effective test in differentiating benign from malignant lesion.

  • PDF

Thallium-201 SPECT Imaging of Brain Tumors (Thallium-201 SPECT 뇌종양 영상)

  • Kim, Sang-Eun;Choi, Chang-Woon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Yoon, Byung-Woo;Roh, Jae-Kyu;Jung, Hee-Won
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.14-25
    • /
    • 1992
  • Thallium-201 $(^{201}T1)$ SPECT studies were performed on a normal volunteer and 12 patients with intracerebral lesions: 3 patients with gliomas, 3 patients with meningiomas, 1 patient each with metastatic tumor, brain abscess, and cerebral infarction, and 3 postirradiation patients. (2 with metastatic tumors, 1 with lymphoma). A $^{201}T1$ index, based on the ratio of $^{201}T1$ uptake in the brain lesion versus the homologous contralateral brain, was calculated and compared with tumor histology and CT/MRI findings. The SPECT $^{201}T1$ scan showed minimal uptake of tracer in a normal brain. There was substantial uptake of $^{201}T1$ in high-grade gliomas (index>1.5) with little uptake in low-grade lesions. A previously irradiated patient with recurrent astrocytoma, in whom MRI study was unable to distinguish tumor recurrence from necrosis, showed the lesions with high $^{201}T1$ indices in both hemispheric regions (2.50/1.93), suggesting tumor recurrence. Two meningiomas and a metastatic tumor showed varying degrees of $^{201}T1$ uptake (index $1.71\sim8.15$), revealing that $^{201}T1$ uptake is not exclusive to high-grade gliomas. In 2 postirradiation patients with metastatic tumors, no abnormal $^{201}T1$ uptake was found in the cerebral lesions, shortly after the initiation of radiation therapy or despite the persistence of enhancing lesions-though improved-on MR images, suggesting that $^{201}T1$ uptake may reflect the metabolic and possibly clonogenic activities of tumors and the brain $^{201}T1$ SPECT imaging might be valuable for the evaluation of tumor responsiveness to the therapy and for early detection of tumor recurrence. A patient with brain abscess on antibiotic treatment, showig increased uptake of $^{201}T1$ in the resolving lesions (index 2.87/1.52) is discussed. In a patient with cerebral infarction, there was no abnormal uptake of $^{201}T1$ in infarcted tissue. When using a threshold index of 1.5, correlation rate between $^{201}T1$ uptake and contrast enhancement of the cerebral lesions on CT/MRI was 73% (8/11). In conclusion, the brain $^{201}T1$ SPECT imaging may be useful for assessment of tumor response to the therapy and to predict low-or high-grade lesions.

  • PDF

Functional Significance of Angiographic Collaterals in Patients with Totally Occluded Right Coronary Artery: Intracoronary Thallium-201 Scintigraphy (우측 관상동맥 폐쇄 환자에서 관상동맥내 Thallium-201 주사를 이용한 측부 혈행의 의의)

  • Lee, Do-Yun;Lee, Jong-Doo;Cho, Seung-Yun;Shim, Won-Heum;Ha, Jong-Won;Kim, Han-Soo;Kwon, Hyuk-Moon;Jang, Yang-Soo;Chung, Nam-Sik;Kim, Sung-Soon;Park, Chang-Yun;Kim, Young-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.210-217
    • /
    • 1993
  • To compare the myocardial viability in patients suffering from total occlusion of the right coronry artery (RCA) with the angiographic collaterals, intracoronary injection of Thallium-201 (T1-201) was done to 14 coronary artery disease (CAD) patients (pts) with total occlusion of RCA and into four normal subjects for control. All 14 CAD pts had Grade 2 or 3 collateral circulations. There were 14 male and 4 females, and their ages ranged from 31 to 70 years. In nine pts, T1-201 was injected into left main coronary artery (LCA) ($300{\sim}350{\mu}Ci$) to evaluate the myocardial viability of RCA territory through collateral circulations. The remaining five pts received T1-201 into RCA ($200{\sim}250{\mu}Ci$) because two had intraarterial bridging collaterals and three had previous successful PTCA. Planar & SPECT myocardial perfusion images were obtained 30 minutes, and four to five hours after T1-201 injection. Intravenous T1-201 reinjection (six pts) or $^{99m}Tc-MIBI$ (two pts) were also performed in eight CAD pts. Intracoronary myocardial perfusion images were compared with intravenous T1-201 (IV T1-201) images, ECG, and ventriculography. Intracoronary T1-201 images proved to be superior to that of IV T1-201 due to better myocardial to background uptake ratio and more effective in the detection of viable tissue. We also found that perfusion defects were smaller on intracoronary T1-201 images than those on the IV T1-201. All of the 14 CAD pts had either mostly viable myocardium (seven pts) or large area of T1-201 perfusion (seven pts) in RCA territory, however ventriculographic wall motion and ECG did not correlate well with intracoronary myocardial perfusion images. In conclusion, total RCA occlusion patients with well developed collateral circulation had large area of viable myocardial in the corresponding territory.

  • PDF

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF

Effects of Potassium-Channel Opener on Thallium-201 Kinetics: In-vitro Study in Rat Myocyte Preparations and In-vivo Mice Biodistribution Study (K-통로개방제가 배양심근세포와 생쥐 체내의 Thallium-201역동학에 미치는 영향)

  • Lee, Jae-Tae;Kim, Eun-Ji;Ahn, Byeong-Cheol;Sohn, Kang-Kyun;Lee, Kyu-Bo;Ha, Jeoung-Hee;Kim, Chun-K.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.507-515
    • /
    • 1996
  • Background : Potassium channel opener (K-opener) opens ATP-sensitive K'-channel located at cell membrane and induces potassium efflux from cytosol, resulting in intracellular hyperpolarization. Newly synthesized K-opener is currently examined for pharmacologic potency by means of rubidium release test from smooth muscle strip pre-incubated with Rb-86. Since in-vivo behavior of thallium is similar to that of rubidium, we hypothesized that K-opener can alter T1-201 kinetics in vivo. Purpose : This study was prepared to investigate the effects of pinacidil (one of potent K-openers) on the T1-201 uptake and clearance in cultured myocyte, and in-vivo biodistribution in mice. Methods : Spontaneous contracting myocytes were prepared to imitate in-vivo condition from 20 hearts of 3-5 days old Sprague-Dawley rat and cultured for 3-5 days before use ($5{\times}10^5$ cells/ml). Pinacidil was dissolved in 10% DMSO solution at a final concentration of 100nM or l0uM and was co-incubated with T1-201 in HBSS buffer for 20-min to evaluate its effect on cellular T1-uptake, or challenged to cell preparation pre-incubated with T1-201 for washout study. Two, 40 or $100{\mu}g$ of pinacidil was injected intravenously into ICR mice at 10 min after $5{\mu}Ci$ T1-201 injection, and organ uptake and whole body retention rate were measured at different time points. Results : Co-incubation of pinacidil with T1-201 resulted in a decrease in T1-201 uptake into cultured myocyte by 1.6 to 2.5 times, depending on pinacidil concentration and activity of T1-201 used. Pinacidil enhanced T1-201 washout by 1.6-3.1 times from myocyte preparations pre-incubated with T1-201. Pinacidil treatment appears to be resulted in mild decreases in blood and liver activity in normal mice, in contrast, renal and cardiac uptake were mildly decreased in a dose dependent manner. Whole body retention ratios of T1-201 were lower at 24 hour after injection with $100{\mu}g$ of pinacidil than control. Conclusion : These results suggest that treatment with K-opener may affect the interpretation of T1-201 myocardial images, due to decreasing thallium accumulation and enhancing washout from myocardium.

  • PDF