• Title/Summary/Keyword: Text neck

Search Result 21, Processing Time 0.025 seconds

The Wearable Sensor System to Monitor the Head & Neck Posture in Daily Life (웨어러블 센서를 이용한 일상생활중 머리-목 자세 측정 시스템)

  • Lee, Jaehyun;Chee, Youngjoon;Bae, Jieun;Kim, Haseon;Kim, Younghoon
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.112-118
    • /
    • 2016
  • The neck pain is fairly common occurance. Forward head posture and text neck are poor postures which may be related with neck pain but the evidence is not enough. We developed the wearable sensor which can assess the head & neck posture in daily life. Microprocessor, Bluetooth low energy, and 3-axis accelerometer, rechargeable battery and vibratior for reminding are used to implement the wearable sensor. Real-time algorithm to parameterize the posture for one epoch is implemented which classifies the posture in the epoch into three classed; dynamic, static_good posture, and static_poor posture. Also the algorithm makes reminding to its wearer to give them the prolonged poor posture is detected. The mean error of measurement was 1.2 degree. The correlation coefficient between neck angle and craniovertebral angle was 0.9 or higher in all cases. With the pilot study on text neck syndrome was also quatified. Average of neck angle were 74.3 degree during the listening in the classroom and 57.8 degree during the smartphoning. Using the wearable sensor suggested, the poor postures of forward head posture and neck neck can be detected in real-time which can remind the wearer according to his/her setting.

The Estimation of Craniovertebral Angle using Wearable Sensor for Monitoring of Neck Posture in Real-Time (실시간 목 자세 모니터링을 위한 웨어러블 센서를 이용한 두개척추각 추정)

  • Lee, Jaehyun;Chee, Youngjoon
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.278-283
    • /
    • 2018
  • Nowdays, many people suffer from the neck pain due to forward head posture(FHP) and text neck(TN). To assess the severity of the FHP and TN the craniovertebral angle(CVA) is used in clinincs. However, it is difficult to monitor the neck posture using the CVA in daily life. We propose a new method using the cervical flexion angle(CFA) obtained from a wearable sensor to monitor neck posture in daily life. 15 participants were requested to pose FHP and TN. The CFA from the wearable sensor was compared with the CVA observed from a 3D motion camera system to analyze their correlation. The determination coefficients between CFA and CVA were 0.80 in TN and 0.57 in FHP, and 0.69 in TN and FHP. From the monitoring the neck posture while using laptop computer for 20 minutes, this wearable sensor can estimate the CVA with the mean squared error of 2.1 degree.

Skeleton-Based Data Learning Framework to Efficiently and Accurately Find Text Neck Posture (거북목 자세를 효율적이고 정확하게 찾기 위한 뼈대 기반 데이터 학습 프레임워크)

  • Na, Hong Eun;Kim, Jong-Hyun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.01a
    • /
    • pp.361-364
    • /
    • 2022
  • 본 논문에서는 스마트 기기를 사용할 시 자세가 거북목 자세인지 아닌지 판별하는 시스템을 제안한다. 거북목 증후군이란 목이 구부정하게 앞으로 나오는 자세를 오래 취해 목이 일자목으로 바뀌고 뒷목, 어깨, 허리 등에 통증이 생기는 증상을 말하며, 수술이나 약물치료보다 평소의 자세 습관을 고치는 방법이 효과적이다. 기존의 연구들은 노트북에 내장되어있는 웹캠을 이용한 CNN기반의 학습모델은 영상의 명도와 학습 데이터 등에 많은 영향을 받고 학습 데이터를 모을 때 초상권 문제로 수집이 어렵다. 본 논문에서는 이러한 문제를 예방하고자 Openpose 오픈 소스를 이용한 뼈대를 기반으로 측면에서의 앉은 자세를 한습 모델로 실시간 검증하여, 거북목 자세인지 아닌지를 효율적이고 정확하게 판별한다.

  • PDF

Comparison of Electromyographic Activities in the Neck Region According to the Screen Height and Document Holder Position (스크린 높이와 서류 고정대 위치에 따른 경부 주위 근육의 활성 정도 비교)

  • Kwon, Hyuk-Cheol;Jeong, Dong-Hoon
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.829-837
    • /
    • 2001
  • Using Video Display Terminals(VDT) in the working environment often causes health complaints in the neck and shoulder region. This study was conducted on ten subjects, in order to investigate the change of electromyographic activities in the neck region(sternocleidomastoid muscle, upper trapezius muscle and erector muscle of cervical spine)with regards to the screen height and document holder position. A total of six different conditions of screen height and document holder position were measured during subjects performed a text-entry task for a duration of 10min. The raw EMG signal was transmuted into the root mean square(RMS). Two-way ANOVA for repeated measures was used to analyse the effects of the two factors. As a result, changing the screen height and document holder position has no effect on electromyographic activities in the neck region.

  • PDF

Comparison of Vowel and Text-Based Cepstral Analysis in Dysphonia Evaluation (발성장애 평가 시 /a/ 모음연장발성 및 문장검사의 켑스트럼 분석 비교)

  • Kim, Tae Hwan;Choi, Jeong Im;Lee, Sang Hyuk;Jin, Sung Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.26 no.2
    • /
    • pp.117-121
    • /
    • 2015
  • Background : Cepstral analysis which is obtained from Fourier transformation of spectrum has been known to be effective indicator to analyze the voice disorder. To evaluate the voice disorder, phonation of sustained vowel /a/ sound or continuous speech have been used but the former was limited to capture hoarseness properly. This study is aimed to compare the effectiveness in analysis of cepstrum between the sustained vowel /a/ sound and continuous speech. Methods : From March 2012 to December 2014, total 72 patients was enrolled in this study, including 24 unilateral vocal cord palsy, vocal nodule and vocal polyp patients, respectively. The entire patient evaluated their voice quality by VHI (Voice Handicap Index) before and after treatment. Phonation of sustained vowel /a/ sample and continuous speech using the first sentence of autumn paragraph was subjected by cepstral analysis and compare the pre-treatment group and post-treatment group. Results : The measured values of pre and post treatment in CPP-a (cepstral peak prominence in /a/ vowel sound) was 13.80, 13.91 in vocal cord palsy, 16.62, 17.99 in vocal cord nodule, 14.19, 18.50 in vocal cord polyp respectively. Values of CPP-s (cepstral peak prominence in text-based speech) in pre and post treatment was 11.11, 12.09 in vocal cord palsy, 12.11, 14.09 in vocal cord nodule, 12.63, 14.17 in vocal cord polyp. All 72 patients showed subjective improvement in VHI after treatment. CPP-a showed statistical improvement only in vocal polyp group, but CPP-s showed statistical improvement in all three groups (p<0.05). Conclusion : In analysis of cepstrum, text-based analysis is more representative in voice disorder than vowel sound speech. So when the acoustic analysis of voice by cepstrum, both phonation of sustained vowel /a/ sound and text based speech should be performed to obtain more accurate result.

  • PDF

Experiment of tong-neck Flange Cold Forging Process Using Plasticine (플라스티신을 이용한 롱넥 플랜지 냉간 단조 공정의 모사 실험)

  • 이호용;임중연;이상돈
    • Transactions of Materials Processing
    • /
    • v.10 no.1
    • /
    • pp.67-74
    • /
    • 2001
  • The cold forging process to produce a long-neck flange is investigated by using model material test. The two stage process with optimum design condition is examined using plasticine, which is suitable to model steel at room temperature. The similarity theory is employed to estimate the forging load of each sequence by strict application of similarity condition between steel(AISI 1015) and plasticine material The model test results are compared with the simulation results and shows good agreement. The proper forging process with least forming energy can be resulted in $25^{\circ}$ of extrusion semi-die angle.

  • PDF

A neck healthy warning algorithm for identifying text neck posture prevention (거북목 자세를 예방하기 위한 목 건강 경고 알고리즘)

  • Jae-Eun Lee;Jong-Nam Kim;Hong-Seok Choi;Young-Bong Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.3
    • /
    • pp.115-122
    • /
    • 2022
  • With the outbreak of COVID-19 a few years ago, video conferencing and electronic document work have increased, and for this reason, the proportion of computer work among modern people's daily routines is increasing. However, as more and more people work on computers in the wrong posture for a long time, the number of patients with poor eyesight and text neck is increasing. Until recently, many studies have been published to correct posture, but most of them have limitations that users may experience discomfort because they have to correct posture by wearing equipment. A posture correction sensor algorithm is proposed to prevent access to the minimum distance between a computer monitor and a person using an ultrasonic sensor device. At this time, an algorithm for minimizing false alarms among warning alarms that sound at the minimum distance is also proposed. Because the ultrasonic sensor device is used, posture correction can be performed without attaching a device to the body, and the user can relieve discomfort. In addition, experimental results showed that accuracy can be improved by reducing false alarms by removing more than half of the noise generated during distance measurement.

Comparison Research on the Ease of Fitted Dress Shirt Patterns

  • Lee, Eunhae;Park, Sanghee
    • Journal of Fashion Business
    • /
    • v.18 no.3
    • /
    • pp.91-103
    • /
    • 2014
  • Shirts which have been a inner-wear in men's suit in the past, are being changed into an item that 20's men utilize to their individuality. Dress shirts have gotten out of its shape, becoming tight and slim with activity and fashion trend. In this study, two patterns of fitted dress shirts in a clothing construction text book were compared with the pattern of an apparel company with regard to the size tolerance and appearance silhouette; this comparison was performed through a fitting test and an appearance evaluation. According to the study, size tolerance of chest girth and waist girth were about 6~8cm and 10~18cm, respectively. Neck girth of the collar was tight in both the fitting test and appearance evaluation. Thus, the measurement value of the neck base girth had to be used for the collar pattern making. Moreover, approximately 35cm is a moderate size for the width on the upper arm in sleeve. Therefor the factors such as size tolerance of waist girth, height of sleeve cap, slim sleeve width and measurement value of neck base girth are being considered for the pattern making of fitted dress shirts.

Takayasu`s Arteritis: A case Report (Takayasu 씨 동맥염 - 치험 1례)

  • 송진천
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.402-406
    • /
    • 1990
  • Recently we have experienced a case of Takayasu’s arteritis involving both common carotid artery, left subclavian artery, left renal artery, and the right pulmonary artery. The patients was 27 year-old female and she was admitted because of neck pain, dizziness and palpitation. Renal artery angioplasty with Griintzig balloon catheter was performed with successful result. And then bypass graft surgery using bifurcated Gore- Text graft was performed with satisfactory result.

  • PDF