• Title/Summary/Keyword: TestBed

Search Result 1,626, Processing Time 0.032 seconds

Incineration of Waste Water Sludge and Coal In a Circulating Fluidized Bed Combustor (순환유동층에서 폐수슬러지와 석탄의 혼소 특성)

  • Bae, Dal-Hee;Shun, Do-Won;Park, Jae-Hyeon;Ryu, Ho-Jung;Park, Do-Hyun
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.165-172
    • /
    • 2004
  • Co-incineration of coal and wastewater sludge was r;erfonn:rl in a O.lMWth bench scale circulating fluidized bed combustor(CFBC) Sludge was received from a wastewater treatment plant in a dye industrial complex in Busan. Metropolis. Moisture content of received sludge was 80%. Coal and sludge mixture was prepared with weight ratio of 90/10, 85/15 and 80/20. Co-combustion characteristics of the coal and sludge mixture demonstrated stable combustion conditions. Component analysis, incineration characteristics, boiler performance was measured before and after the test and application for commercial 59MWth CFBC boiler. The release of hazardous components such as $SO_2$ and Cl was suppressed by the presence of inherent minerals of Ca, Na, K in coal and sludge mixture. Pre-drying was not essential but it was recommended for the benefits of manageability of sludge.

  • PDF

Experimental Study of Decomposition Characteristics of Catalyst for Hydrazine Monopropellant Thruster (하이드라진 단일 액체추력기용 촉매의 분해거동 특성 연구)

  • Kim, Jung-Hun;Lee, Jae-Won;Kim, In-Tae;Yu, Myoung-Jong;Lee, Kyun-Ho;Kim, Su-Kyum
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.151-154
    • /
    • 2007
  • The purpose of this study is to identify the basic concept of thruster design through the visualization firing test on a hydrazine thruster. We designed the visual catalyst bed on the basis of the 1lbf hydrazine thruster for a low earth orbit satellite and observed visually the internal catalyst bed reaction.

  • PDF

Circulting Fluidized Bed Combustion of Refuse Derived Fuel and Steam Production (폐기물 고형연료(RDF)의 순환유동층 연소 및 증기생산)

  • Shun, Do-Won;Bae, Dal-Hee;Cho, Sung-Ho;Lee, Seung-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.613-616
    • /
    • 2007
  • A pilot scale circulating fluidized bed for refuse derived fuel is developed and constructed in order to demonstrate efficient and safe utilization of waste fuel. The capacity of the facility is 8 steam tons per hour with the steam quality of $450^{\circ}C$ and 38atm. The quantity and the quality of the produced steam is sufficient to produce 1MWe power capacity. The test operation proved the high combustion efficiency of 99% and up. The emissions of NOx, SOx in flue gas are below 100, 60ppm respectively with out any emission control. HCl emissions were above 400ppm at the combustor exit but reduced below 10ppm after scrubber.

  • PDF

Hydrogen Peroxide Gas Generator with Dual Catalytic Bed for Non-preheating Start-up (비예열 시동특성을 갖는 이원 촉매 베드 과산화수소 가스발생기)

  • Lim, Ha-Young;An, Sung-Yong;Kwon, Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.163-167
    • /
    • 2007
  • Silver is widely used for catalytic decomposition of hydrogen peroxide, but start-up at room temperature is difficult and cannot withstand at high temperature. In this paper, to overcome these short-comings, a dual catalytic bed which consists of a vaporizer catalyst and a high temperature catalyst was studied. Platinum was selected as the vaporizer catalyst and perovskite type catalyst was selected for the high temperature catalyst. Preliminary test demonstrated start-up capability with non-preheating at room temperature and good thermal stability at high temperature.

  • PDF

A Study on Commercialization of Condensing Fluidized-Bed Heat Exchanger for Paper Mill Hood Exhaust Air (제지설비 후드 배공기의 응축형 유동층열교환기 상용화 연구)

  • Park, Sang-Il
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1101-1106
    • /
    • 2006
  • The water fluidized bed heat exchanger was installed to recover heat from paper mill hood exhaust air containing lot of moisture and also fouling contaminants. The hood exhaust air flow rate was about $110,000m^3/hr$ at $70^{\circ}C$. The commercial scale field test apparatus has been operated for 3 months. As a result of operation, total heat recovered was 2,380,000 kcal/hr and proportion of the latent heat to total heat was 74%. The annual energy saving was estimated as 450 million won.

  • PDF

An Approach to the Optimization of Catalyst-bed L/D Configuration in 70 N-class Hydrazine Thruster (70 N급 하이드라진 추력기의 촉매대 형상(L/D) 최적화 연구)

  • Jung, Hun;Kim, Jong Hyun;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.6
    • /
    • pp.30-37
    • /
    • 2013
  • A ground hot-firing test was conducted to take out the optimal design configurations for the catalyst bed of liquid-monopropellant hydrazine thruster which could be used for primary engine or attitude control thruster of space vehicles. Performance characteristics with the variation of thrust-chamber length are investigated in terms of thrust, specific impulse, chamber pressure, characteristic velocity, and hydrazine decomposition rate. Additionally, the correlations between propellant-supply pressure and performance parameters are given. As results, increase of catalyst-bed length leads to performance degradation in this test condition, and also decreases propellant consumption efficiency with the supply pressure variation.

Seepage Characteristics of Domestic Bed Sediments Mixed with Good-quality Soil as Levee Fill Material (양질토와 혼합처리된 국내 하상토의 제체재료로서의 침투특성)

  • Choi, Bong-Hyuck;Kim, Kyung-Min;Kim, Jin-Man;Lee, Dae-Yeong
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.10
    • /
    • pp.105-111
    • /
    • 2008
  • To improve the stability of levee structure, it is required to use good quality fill materials, intensive management, appropriate hydraulic structure and construction of cut-off wall. In particular, the most important factor of levee construction technology is to use bed sediment for its safety. In this study, seepage model test and numerical analysis were performed based on a standard section of levee recommended in the river design standard of korea (2005). The results of test and analysis show that most of the bed soil is a sand (SP in USCS), which does not satisfy the permeability criteria for levee materials ($< k=10^{-3}cm/sec$), thus for the safety of levee it is required to adopt a stabilizing method such as good quality soil mixing, water content control.

Test-bed evaluation of developed small constructed wetland for using in urban areas (도시지역에 적용하기 위한 소규모 인공습지 Test-bed 시설 평가)

  • Kang, Chang-Guk;Lee, So-Young;Cho, Hye-Jin;Lee, Yuw-Ha;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.455-463
    • /
    • 2011
  • Conventional construction technologies have been continually applied without consideration of its impact to the environment. This resulted to various problems including the negative responses of local citizens that regarded some constructed facilities as aversive facilities causing environmental and hydraulic problems in the urban area, etc. To prevent these problems, therefore, alternative methods should be undertaken. A new approach termed "Low Impact Development (LID)" technology is currently adapted in developed countries around the world. This study aims to investigate the efficiency of the developed small constructed wetland (SCW) with horizontal subsurface flow as a LID technique applicable in urban areas. Two test-bed facilities were constructed and monitoring had been conducted between July 2010 and June 2011. Based on the findings, the removal efficiencies achieved for TSS, $COD_{Cr}$, TN, TP, Total Fe, Total Pb for the SCW-1 were 66, 53, 46, 55, 67 and 50%, respectively. On the other hand, the SCW-2 attained 82, 62, 51, 48, 74 and 42% efficiency for TSS, $COD_{Cr}$, TN, TP, Total Fe, Total Pb, respectively. The results indicated that the removal of particulate matter and heavy metals which are considered as main pollutants from stormwater runoff in urban areas was satisfactory in the system. Therefore, the test-beds proved to be appropriate for the treatment of pollutants in urban landuses such as road, parking lot, etc. The results of this study can contribute to the conservation of aquatic ecosystems and restoration of natural water cycle in the urban areas.

Development of the Distributed Real-time Simulation System Based on HLA and DEVS (DEVS형식론을 적응한 HLA기반의 분산 실시간 시뮬레이션 시스템 개발)

  • Kim, Ho-Jeong;Lee, Jae-Hyun;Cho, Kil-Seok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.25-32
    • /
    • 2006
  • Weapon systems composed of several subsystems execute various engagement missions in distributed combat environments in cooperation with a large number of subordinate/adjacent weapon systems as well as higher echelons through tactical data links. Such distributed weapon systems require distributed real-time simulation test beds to integrate and test their operational software, analyze their performance and effects of cooperated engagement, and validate their requirement specifications. These demands present significant challenges in terms of real-time constraints, time synchronization, complexity and development cost of an engagement simulation test bed, thus necessitate the use of high-performance distributed real-time simulation architectures, and modeling and simulation techniques. In this paper, in order to meet these demands, we presented a distributed real-time simulation system based on High Level Architecture(HLA) and Discrete Event System Specification(DEVS). We validated its performance by using it as a test bed for developing the Engagement Control System(ECS) of a surface-to-air missile system. The proposed technique can be employed to design a prototype or model of engagement-level distributed real-time simulation systems.

Hardware and Software Implementation of a GPS Receiver Test Bed Running from PC (PC 기반 GPS 수신기 하드웨어 모듈 및 펌웨어 개발)

  • Long, Nguyen Phi;Hieu, Nguyen Hoang;Lee, Sang-Hoon;Park, Ok-Deuk;Kim, Hyun-Su;Kim, Han-Sil
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.394-396
    • /
    • 2006
  • When developing a new GPS receiver module, the essential problems are evaluation of reliable algorithms, software debugging, and performance comparison between algorithms to find optimal solution. Most GPS receiver modules nowadays use a correlator to track signals from satellites and an MCU (Micro Controller Unit) to control operations of the entire module. The problem of software evaluation from MCU is very difficult, due to limitation of MCU resources and low ability of interfacing with user. Normally, user has to expense special tool kit for a limiting access to MCU but it is also hard to use. This article introduces an implementation of a GPS receiver test bed using correlator GP2021 interfacing with ISA (Industry Standard Architecture) PC bus. This way can give user complete control and visibility into the operation of the receiver, then user can easily debug program and test algorithms. For this article, the least square method is implemented to test the hardware and software performance.

  • PDF