• Title/Summary/Keyword: Test section

Search Result 3,092, Processing Time 0.042 seconds

A Study on the Influence of Finishing and Polishing Methods on the Gap between Denture Base Resin and Soft Liner (의치의 마무리와 연마법이 의치상 레진과 연성 이장재 간의 공극에 미치는 영향에 관한 연구)

  • Jung, Seung-Hwan;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.325-335
    • /
    • 2008
  • The junction between resilient denture liner and the denture base is difficult to finish and polish due to difference of the physical property of the materials. Gaps tend to be formed during finishing and polishing procedures. The purpose of this study was measuring the width of junctional gap between $Molloplast-B^{(R)}$ and denture base material after finishing and polishing procedure, and evaluating the effect of method and direction on gap width. $Molloplast-B^{(R)}$ was processed (according to the manufacturer's instruction) against Lucitone $199^{(R)}$ acrylic resin. 50 specimens were fabricated with a raised center section. All of specimens were examined and photographed with a stereoscopic microscope(x120), and the largest gap along the junction of $Molloplast-B^{(R)}$ and acrylic resin on each specimen was measured. One-way analysis of variance(ANOVA) and independent t-test at 95% confidence level were used to analyze the data and to compare groups. The results of this study were as follows. In comparison with finishing tools, the gap width was the largest in $Molloplast^{(R)}$-Cutter and the smallest in FSQ-cross cut bur. There was statistically significant difference between FSQ-cross cut bur and $Molloplast^{(R)}$-Cutter(p<0.05). There was no significant difference in gap width between the direction of polishing. The mean value of gap width was the smallest in case of no polishing, and the largest in case of polishing with pumice & tin oxide. There was statistically significant difference between pumice and pumice & tin oxide. From the results, it is concluded that the use of $Molloplast^{(R)}$-Cutter in clinic need serious consideration even though it has good cutting ability. Further careful study is needed for finishing and polishing methods for decreasing gap width in junction of two materials.

Effects of Growth Period and Cumulative Temperature on Flowering, Ripening and Yield of Soybean by Sowing Times (파종시기별 생육일수 및 적산온도 변화가 콩의 개화, 등숙 및 수량에 미치는 영향)

  • Lee, Jae Eun;Jung, Gun Ho;Kim, Sung Kook;Kim, Min Tae;Shin, Su Hyeon;Jeon, Weon Tai
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.64 no.4
    • /
    • pp.406-413
    • /
    • 2019
  • The purpose of this research was to analyze the effect of different sowing times on the flowering and maturing of major soybean cultivars by varying day length and temperature in the central plain region. The average of growth period and cumulative temperature in five test cultivars by sowing times were 121 days and 2,972℃ on June 1, respectively and gradually decreased to 85 days, 2,042℃, respectively on July 20. Analysis of the flowering response according to the sowing times showed that flowering was greatly influenced by the decrease of photoperiod until the sowing on July 10, and the minimum number of days for flowering were 27 days, 36 days, respectively in early and mid-rate maturing type in the central plain region. Daepung 2 is classified to the same ecotype with Daewonkong, the total number of growing days was not different between two cultivars, but ripening period (R2-R6) was longer by 5 days and yield was higher by 11% in Daepung 2. The maturity rate was also high and safe enough to maintain more than 90% through the entire sowing times. This ecological characteristic can be usefully applied as a section index for breeding environmental stress resistant and high yielding soybean varieties. The yield of 4 domestic cultivars (except TI196944) sowing on July 20 were 85~92% levels compared to sowing on June 20.

Definition of Child and Youth Welfare and Proposals for the Reform of Legal System (아동·청소년 복지의 개념과 법체계의 개선방안)

  • Cho, Sung-Hae
    • Journal of Legislation Research
    • /
    • no.41
    • /
    • pp.43-85
    • /
    • 2011
  • Child and youth welfare law in Korea is vague and complex. In a narrow sense it means the research on the provisions of the Child Welfare Act. In a broad sense it embraces all of the social welfare system regarding to the protection for children and youth. Regardless of the scope of child and youth welfare law it should be cleared what the term of child and youth means in Korean legal regulation. Historically, child protection in Korea was based on the good intentions of individuals to protect war orphan children from poverty or danger after the end of the Korean War. It is the story of the evolving status of children from being viewed as dependant of the parents to becoming rights-based citizens, even not in Constitution. In Korea neither parents nor children have constitutionally recognized right. According to Korean Constitution the parents have only the obligation to educate their children. And the state ist obliged to improve the welfare of the youth(section 34). In compliance with this article there are lots of statutes regulating youth welfare. This article reviews the legal definition of child and youth to test the uncertain definition of child and youth welfare in relation to the treatment of children's and youth's legal status in Korea. According to the Child Welfare Act child is the person under age of 18, while the legal definition of youth oscillates between the person under the age of 19 and the person over the age 9 to the age of 23. As a result child welfare is often used as the synonym of youth welfare, and vice versa. The lack of the arrangement of the legal definition of child and youth is based on the historical reasons that the legal definitions of youth (under the age of 19 or over the age 9 to the age of 23) newly appeared in the statutes regulating youth welfare, whereas the Child Welfare Act still maintained the definition of child under the age of 18. In order to get rid of the confusion of the definition of the child and youth, a part of certain statues should combine with another Act according to the purpose of the individual amended statutes. And the definition of child and youth should be subdivided into 3 or 4 classes, namely infant(0-6), child(7-13), youth(14-18) and young adult(19-26). Furthermore this article proposes a reform of the existing legal system pursuant to the nature of the law, i.g. whether the issued or amended Act takes on a selective(residual) or universal character.

Development of remote control automatic fire extinguishing system for fire suppression in double-deck tunnel (복층터널 화재대응을 위한 원격 자동소화 시스템 개발 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Yangkyun;Park, Byoungjik;Kim, Whiseong;Park, Sangheon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.167-175
    • /
    • 2019
  • To effectively deal with the fire in tunnel which is mostly the vehicle fire, it's more important to suppress the fire at early stage. In urban tunnel, however, accessibility to the scene of fire by the fire fighter is very limited due to severe traffic congestion which causes the difficulty with firefighting activity in timely manner and such a problem would be further worsened in underground road (double-deck tunnel) which has been increasingly extended and deepened. In preparation for the disaster in Korea, the range of life safety facilities for installation is defined based on category of the extension and fire protection referring to risk hazard index which is determined depending on tunnel length and conditions, and particularly to directly deal with the tunnel fire, fire extinguisher, indoor hydrant and sprinkler are designated as the mandatory facilities depending on category. But such fire extinguishing installations are found inappropriate functionally and technically and thus the measure to improve the system needs to be taken. Particularly in a double-deck tunnel which accommodates the traffic in both directions within a single tunnel of which section is divided by intermediate slab, the facility or the system which functions more rapidly and effectively is more than important. This study, thus, is intended to supplement the problems with existing tunnel life safety system (fire extinguishing) and develop the remote-controlled automatic fire extinguishing system which is optimized for a double-deck tunnel. Consequently, the system considering low floor height and extended length as well as indoor hydrant for a wide range of use have been developed together with the performance verification and the process for commercialization before applying to the tunnel is underway now.

Development of tracer concentration analysis method using drone-based spatio-temporal hyperspectral image and RGB image (드론기반 시공간 초분광영상 및 RGB영상을 활용한 추적자 농도분석 기법 개발)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun;Han, Eunjin;Kwon, Siyoon;Kim, Youngdo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.8
    • /
    • pp.623-634
    • /
    • 2022
  • Due to river maintenance projects such as the creation of hydrophilic areas around rivers and the Four Rivers Project, the flow characteristics of rivers are continuously changing, and the risk of water quality accidents due to the inflow of various pollutants is increasing. In the event of a water quality accident, it is necessary to minimize the effect on the downstream side by predicting the concentration and arrival time of pollutants in consideration of the flow characteristics of the river. In order to track the behavior of these pollutants, it is necessary to calculate the diffusion coefficient and dispersion coefficient for each section of the river. Among them, the dispersion coefficient is used to analyze the diffusion range of soluble pollutants. Existing experimental research cases for tracking the behavior of pollutants require a lot of manpower and cost, and it is difficult to obtain spatially high-resolution data due to limited equipment operation. Recently, research on tracking contaminants using RGB drones has been conducted, but RGB images also have a limitation in that spectral information is limitedly collected. In this study, to supplement the limitations of existing studies, a hyperspectral sensor was mounted on a remote sensing platform using a drone to collect temporally and spatially higher-resolution data than conventional contact measurement. Using the collected spatio-temporal hyperspectral images, the tracer concentration was calculated and the transverse dispersion coefficient was derived. It is expected that by overcoming the limitations of the drone platform through future research and upgrading the dispersion coefficient calculation technology, it will be possible to detect various pollutants leaking into the water system, and to detect changes in various water quality items and river factors.

Wetting-Induced Collapse in Fill Materials for Concrete Slab Track of High Speed Railway (고속철도 콘크리트궤도 흙쌓기재료의 Wetting Collapse에 관한 연구)

  • Lee, Sung-Jin;Lee, Il-Wha;Im, Eun-Sang;Shin, Dong-Hoon;Cho, Sung-Eun
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.4
    • /
    • pp.79-88
    • /
    • 2008
  • Recently, the high speed railway comes into the spotlight as the important and convenient traffic infrastructure. In Korea, Kyung-Bu high speed train service began in bout 400 km section in 2004, and the Ho-Nam high speed railway will be constructed by 2017. The high speed train will run with a design maximum speed of 300-350 km/hr. Since the trains are operated at high speed, the differential settlement of subgrade under the rail is able to cause a fatal disaster. Therefore, the differential settlement of the embankment must be controlled with the greatest care. Furthermore, the characteristics and causes of settlements which occurred under construction and post-construction should be investigated. A considerable number of studies have been conducted on the settlement of the natural ground over the past several decades. But little attention has been given to the compression settlement of the embankment. The long-term settlement of compacted fills embankments is greatly influenced by the post-construction wetting. This is called 'hydro collapse' or 'wetting collapse'. In spite of little study for this wetting collapse problem, it has been recognized that the compressibility of compacted sands, gravels and rockfills exhibit low compressibility at low pressures, but there can be significant compression at high pressures due to grain crushing (Marachi et al. 1969, Nobari and Duncan 1972, Noorany et al. 1994, Houston et al. 1993, Wu 2004). The characteristics of compression of fill materials depend on a number of factors such as soil/rock type, as-compacted moisture, density, stress level and wetting condition. Because of the complexity of these factors, it is not easy to predict quantitatively the amount of compression without extensive tests. Therefore, in this research I carried out the wetting collapse tests, focusing on various soil/rock type, stress levels, wetting condition more closely.

Development and assessment of pre-release discharge technology for response to flood on deteriorated reservoirs dealing with abnormal weather events (이상기후대비 노후저수지 홍수 대응을 위한 사전방류 기술개발 및 평가)

  • Moon, Soojin;Jeong, Changsam;Choi, Byounghan;Kim, Seungwook;Jang, Daewon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.775-784
    • /
    • 2023
  • With the increasing trend of extreme rainfall that exceeds the design frequency of man-made structures due to extreme weather, it is necessary to review the safety of agricultural reservoirs designed in the past. However, there are no local government-managed reservoirs (13,685) that can be discharged in an emergency, except for reservoirs over a certain size under the jurisdiction of the Korea Rural Affairs Corporation. In this case, it is important to quickly deploy a mobile siphon to the site for preliminary discharge, and this study evaluated the applicability of a mobile siphon with a diameter of 200 mm, a minimum water level difference of 6 m, 420 (m2/h), and 10,000 (m2/day), which can perform both preliminary and emergency discharge functions, to the Yugum Reservoir in Gyeongju City. The test bed, Yugum Reservoir, is a facility that was completed in 1945 and has been in use for about 78 years. According to the hydrological stability analysis, the lowest height of the current dam crest section is 27.15 (EL.m), which is 0.29m lower than the reviewed flood level of 27.44 (EL.m), indicating that there is a possibility of lunar flow through the embankment, and the headroom is insufficient by 1.72 m, so it was reviewed as not securing hydrological safety. The water level-volume curve was arbitrarily derived because it was difficult to clearly establish the water level-flow relationship curve of the reservoir since the water level-flow measurement was not carried out regularly, and based on the derived curve, the algorithm for operating small and medium-sized old reservoirs was developed to consider the pre-discharge time, the amount of spillway discharge, and to predict the reservoir lunar flow time according to the flood volume by frequency, thereby securing evacuation time in advance and reducing the risk of collapse. Based on one row of 200 mm diameter mobile siphons, the optimal pre-discharge time to secure evacuation time (about 1 hour) while maintaining 80% of the upper limit water level (about 30,000 m2) during a 30-year flood was analyzed to be 12 hours earlier. If the pre-discharge technology utilizing siphons for small and medium-sized old reservoirs and the algorithm for reservoir operation are implemented in advance in case of abnormal weather and the decision-making of managers is supported, it is possible to secure the safety of residents in the risk area of reservoir collapse, resolve the anxiety of residents through the establishment of a support system for evacuating residents, and reduce risk factors by providing risk avoidance measures in the event of a reservoir risk situation.

The influence of fitness and type of luting agents on bonding strength of fiber-reinforced composite resin posts (섬유강화 복합레진 포스트의 결합강도에 대한 포스트 공간 적합도 및 접착 시멘트의 영향)

  • Kkot-Byeol Bae;Hye-Yoon Jung;Yun-Chan Hwang;Won-Mann Oh;In-Nam Hwang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.187-194
    • /
    • 2023
  • Purpose: A mismatched size in the post and post space is a common problem during post-fixation. Since this discordance affects the bonding strength of the fiber-reinforced composite resin post (FRC Post), a corresponding luting agent is required. The aim of this study was to evaluate the bonding strength of the FRC post according to the fitness of the fiber post and the type of luting agent. Materials and Methods: Thirty mandibular premolar were endodontic-treated and assigned to two groups according to their prepared post space: Fitting (F) and Mismatching (M). These groups were further classified into three subgroups according to their luting agent: RelyX Unicem (ReX), Luxacore dual (Lux), and Duolink (Duo). A push-out test was performed to measure the push-out bond strengths. The fractured surfaces of each cross-section were then examined, and the fracture modes were classified. Results: In the ReX and Duo subgroups, the F group had a higher mean bond strength; however, the Lux subgroup had no significant difference between the F and M groups. In the analysis of the failure modes, the ReX subgroup had only adhesive failures between the cement and dentin. Conclusion: The result of this study showed that the bond strength of an FRC post was influenced by the type of luting agent and the mismatch between the diameter of the prepared post space and that of the post.

Determination of Cost and Measurement of nursing Care Hours for Hospice Patients Hospitalized in one University Hospital (일 대학병원 호스피스 병동 입원 환자의 간호활동시간 측정과 원가산정)

  • Kim, Kyeong-Uoon
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.6 no.3
    • /
    • pp.389-404
    • /
    • 2000
  • This study was designed to determine the cost and measurement of nursing care hours for hospice patients hostpitalized in one university hospital. 314 inpatients in the hospice unit 11 nursing manpower were enrolled. Study was taken place in C University Hospital from 8th to 28th, Nov, 1999. Researcher and investigator did pilot study for selecting compatible hospice patient classification indicators. After modifying patient classification indicators and nursing care details for general ward, approved of content validity by specialist. Using hospice patient classification indicators and per 5 min continuing observation method, researcher and investigator recorded direct nursing care hours, indirect nursing care hours, and personnel time on hospice nursing care hours, and personnel time on hospice nursing care activities sheet. All of the patients were classified into Class I(mildly ill), Class II (moderately ill), Class III (acutely ill), and Class IV (critically ill) by patient classification system (PCS) which had been carefully developed to be suitable for the Korean hospice ward. And then the elements of the nursing care cost was investigated. Based on the data from an accounting section (Riccolo, 1988), nursing care hours per patient per day in each class and nursing care cost per patient per hour were multiplied. And then the mean of the nursing care cost per patient per day in each class was calculated. Using SAS, The number of patients in class and nursing activities in duty for nursing care hours were calculated the percent, the mean, the standard deviation respectively. According to the ANOVA and the $Scheff{\'{e}$ test, direct nursing care hours per patient per day for the each class were analyzed. The results of this study were summarized as follows : 1. Distribution of patient class : class IN(33.5%) was the largest class the rest were class II(26.1%) class III(22.6%), class I(17.8%). Nursing care requirements of the inpatients in hospice ward were greater than that of the inpatients in general ward. 2. Direct nursing care activities : Measurement ${\cdot}$ observation 41.7%, medication 16.6%, exercise ${\cdot}$ safety 12.5%, education ${\cdot}$ communication 7.2% etc. The mean hours of direct nursing care per patient per day per duty were needed ; 69.3 min for day duty, 64.7 min for evening duty, 88.2 min for night duty, 38.7 min for shift duty. The mean hours of direct nursing care of night duty was longer than that of the other duty. Direct nursing care hours per patient per day in each class were needed ; 3.1 hrs for class I, 3.9 hrs for class II, 4.7 hrs for class III, and 5.2 hrs for class IV. The mean hours of direct nursing care per patient per day without the PCS was 4.1 hours. The mean hours of direct nursing care per patient per day in class was increased significantly according to increasing nursing care requirements of the inpatients(F=49.04, p=.0001). The each class was significantly different(p<0.05). The mean hours of direct nursing care of several direct nursing care activities in each class were increased according to increasing nursing care requirements of the inpatients(p<0.05) ; class III and class IV for medication and education ${\cdot}$ communication, class I, class III and class IV for measurement ${\cdot}$ observation, class I, class II and class IV for elimination ${\cdot}$ irrigation, all of class for exercise ${\cdot}$ safety. 3. Indirect nursing care activities and personnel time : Recognization 24.2%, house keeping activity 22.7%, charting 17.2%, personnel time 11.8% etc. The mean hours of indirect nursing care and personnel time per nursing manpower was 4.7 hrs. The mean hours of indirect nursing care and personnel time per duty were 294.8 min for day duty, 212.3 min for evening duty, 387.9 min for night duty, 143.3 min for shift duty. The mean of indirect nursing care hours and personnel time of night duty was longer than that of the other duty. 4. The mean hours of indirect nursing care and personnel time per patient per day was 2.5 hrs. 5. The mean hours of nursing care per patient per day in each class were class I 5.6 hrs, class II 6.4 hrs, class III 7.2 hrs, class IV 7.7 hrs. 6. The elements of the nursing care cost were composed of 2,212 won for direct nursing care cost, 267 won for direct material cost and 307 won for indirect cost. Sum of the elements of the nursing care cost was 2,786 won. 7. The mean cost of the nursing care per patient per day in each class were 15,601.6 won for class I, 17,830.4 won for class II, 20,259.2 won for class III, 21,452.2 won for class IV. As above, using modified hospice patient classification indicators and nursing care activity details, many critical ill patients were hospitalized in the hospice unit and it reflected that the more nursing care requirements of the patients, the more direct nursing care hours. Emotional ${\cdot}$ spiritual care, pain ${\cdot}$ symptom control, terminal care, education ${\cdot}$ communication, narcotics management and delivery, attending funeral ceremony, the major nursing care activities, were also the independent hospice service. But it is not compensated by the present medical insurance system. Exercise ${\cdot}$ safety, elimination ${\cdot}$ irrigation needed more nursing care hours as equal to that of intensive care units. The present nursing management fee in the medical insurance system compensated only a part of nursing car service in hospice unit, which rewarded lower cost that that of nursing care.

  • PDF

The micro-tensile bond strength of two-step self-etch adhesive to ground enamel with and without prior acid-etching (산부식 전처리에 따른 2단계 자가부식 접착제의 연마 법랑질에 대한 미세인장결합강도)

  • Kim, You-Lee;Kim, Jee-Hwan;Shim, June-Sung;Kim, Kwang-Mahn;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.148-156
    • /
    • 2008
  • Statement of problems: Self-etch adhesives exhibit some clinical benefits such as ease of manipulation and reduced technique-sensitivity. Nevertheless, some concern remains regarding the bonding effectiveness of self-etch adhesives to enamel, in particular when so-called 'mild' self-etch adhesives are employed. This study compared the microtensile bond strengths to ground enamel of the two-step self-etch adhesive Clearfil SE Bond (Kuraray) to the three-step etch-and- rinse adhesive Scotchbond Multi-Purpose (3M ESPE) and the one-step self-etch adhesive iBond (Heraeus Kulzer). Purpose: The purpose of this study was to determine the effect of a preceding phosphoric acid conditioning step on the bonding effectiveness of a two-step self-etch adhesive to ground enamel. Material and methods: The two-step self-etch adhesive Clearfil SE Bond non-etch group, Clearfil SE Bond etch group with prior 35% phosphoric acid etching, and the one-step self-etch adhesive iBond group were used as experimental groups. The three-step etch-and-rinse adhesive Scotchbond Multi-Purpose was used as a control group. The facial surfaces of bovine incisors were divided in four equal parts cruciformly, and randomly distributed into each group. The facial surface of each incisor was ground with 800-grit silicon carbide paper. Each adhesive group was applied according to the manufacturer's instructions to ground enamel, after which the surface was built up using Light-Core (Bisco). After storage in distilled water at $37^{\circ}C$ for 1 week, the restored teeth were sectioned into enamel beams approximately 0.8*0.8mm in cross section using a low speed precision diamond saw (TOPMET Metsaw-LS). After storage in distilled water at $37^{\circ}C$ for 1 month, 3 months, microtensile bond strength evaluations were performed using microspecimens. The microtensile bond strength (MPa) was derived by dividing the imposed force (N) at time of fracture by the bond area ($mm^2$). The mode of failure at the interface was determined with a microscope (Microscope-B nocular, Nikon). The data of microtensile bond strength were statistically analyzed using a one-way ANOVA, followed by Least Significant Difference Post Hoc Test at a significance level of 5%. Results: The mean microtensile bond strength after 1 month of storage showed no statistically significant difference between all adhesive groups (P>0.05). After 3 months of storage, adhesion to ground enamel of iBond was not significantly different from Clearfil SE Bond etch (P>>0.05), while Clearfil SE Bond non-etch and Scotchbond Multi-Purpose demonstrated significantly lower bond strengths (P<0.05), with no significant differences between the two adhesives. Conclusion: In this study the microtensile bond strength to ground enamel of two-step self-etch adhesive Clearfil SE Bond was not significantly different from three-step etch-and-rinse adhesive Scotchbond Multi-Purpose, and prior etching with 35% phosphoric acid significantly increased the bonding effectiveness of Clearfil SE Bond to enamel at 3 months.