• Title/Summary/Keyword: Test scenario

Search Result 558, Processing Time 0.024 seconds

Analysis of Paddy Rice Water Footprint under Climate Change Using AquaCrop (AquaCrop을 이용한 기후변화에 따른 미래 논벼 물발자국 변화 분석)

  • Oh, Bu-Yeong;Lee, Sang-Hyun;Choi, Jin-Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.1
    • /
    • pp.45-55
    • /
    • 2017
  • Climate change causes changes in rainfall patterns, temperature and drought frequency. Climate change impact influences on water management and crop production. It is critical issue in agricultural industry. Rice is a staple cereal crop in South Korea and Korea uses a ponding system for its paddy fields which requires a significant amount of water. In addition, water supply has inter-relationship with crop production which indicates water productivity. Therefore, it is important to assess overall impacts of climate change on water resource and crop production. A water footprint concept is an indicator which shows relationship between water use and crop yield. In addition, it generally composed of three components depending on water resources: green, blue, grey water. This study analyzed the change trend of water footprint of paddy rice under the climate change. The downscaled climate data from HadGEM3-RA based on RCP 8.5 scenario was applied as future periods (2020s, 2050s, 2080s), and historical climate data was set to base line (1990s). Depending on agro-climatic zones, Suwon and Jeonju were selected for study area. A yield of paddy rice was simulated by using FAO-AquaCrop 5.0, which is a water-driven crop model. Model was calibrated by adjusting parameters and was validated by Mann-Whitney U test statistically. The means of water footprint were projected increase by 55 % (2020s), 51 % (2050s) and 48 % (2080s), respectively, from the baseline value of $767m^2/ton$ in Suwon. In case of Jeonju, total water footprint was projected to increase by 46 % (2020s), 45 % (2050s), 12 % (2080s), respectively, from the baseline value of $765m^2/ton$. The results are expected to be useful for paddy water management and operation of water supply system and apply in establishing long-term policies for agricultural water resources.

Prediction of Evacuation Time for Emergency Planning Zone of Uljin Nuclear Site (울진원전 방사선비상계획구역에 대한 소개시간 예측)

  • Jeon, In-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.189-198
    • /
    • 2002
  • The time for evacuation of residents in emergency planning zone(EPZ) of Uljin nuclear site in case of a radiological emergency was estimated with traffic analysis. Evacuees were classified into 4 groups by considering population density, local jurisdictions, and whether they ate residents or transients. The survey to investigate the behavioral characteristics of the residents was made for 200 households and included a hypothetical scenario explaining the accident situation and questions such as dwelling place, time demand for evacuation preparation transportation means for evacuation, sheltering place, and evacuation direction. The microscopic traffic simulation model, CORSIM, was used to simulate the behavior of evacuating vehicles on networks. The results showed that the evacuation time required for total vehicles to move out from EPZ took longer in the daytime than at night in spite that the delay times at intersections were longer at night than in the daytime. This was analyzed due to the differences of the trip generation time distribution. To validate whether the CORSIM model fan appropriately simulate the congested traffic phenomena assumable in case of emergency, a benchmark study was conducted at an intersection without an actuated traffic signal near Uljin site during the traffic peak-time in the morning. This study indicated that the predicted output by the CORSIM model was in good agreement with the observed data. satisfying the purpose of this study.

Analytical Assessment of Blast Damage of 270,000-kL LNG Storage Outer Tank According to Explosive Charges (270,000 kL급 LNG 저장 탱크 외조의 폭발량에 따른 손상도 해석적 평가)

  • Kim, Jang-Ho Jay;Choi, Seung-Jai;Choi, Ji-Hun;Kim, Tae-Kyun;Lee, Tae-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.6
    • /
    • pp.685-693
    • /
    • 2016
  • The outer tank of a liquefied natural gas (LNG) storage tank is a longitudinally and meridionally pre-stressed concrete (PSC) wall structure. Because of the current trend of constructing larger LNG storage tanks, the pre-stressing forces required to increase wall strength must be significantly increased. Because of the increase in tank sizes and pre-stressing forces, an extreme loading scenario such as a bomb blast or an airplane crash needs to be investigated. Therefore, in this study, the blast resistance performance of LNG storage tanks was analyzed by conducting a blast simulation to investigate the safety of larger LNG storage tanks. Test data validation for a blast simulation of reinforced concrete panels was performed using a specific FEM code, LS-DYNA, prior to a full-scale blast simulation of the outer tank of a 270,000-kL LNG storage tank. Another objective of this study was to evaluate the safety and serviceability of an LNG storage tank with respect to varying amounts of explosive charge. The results of this study can be used as basic data for the design and safety evaluation of PSC LNG storage tanks.

Characteristics for Progressive Collapse Behavior and Ultimate Strength of Very Large Marine Structure (초대형 해상구조물의 붕괴거동 및 최종강도 특성)

  • Park, Joo-Shin;Ko, Jae-Yong;Lee, Kyoung-Woo
    • Journal of Navigation and Port Research
    • /
    • v.33 no.5
    • /
    • pp.315-321
    • /
    • 2009
  • The Very Large Marine Structure has been widely used new method of ocean space instead of method for reclamation Therefore, VLFS is proposed to coincide on such request. It can be established regardless of nature of soil and height of water, and stream of flow exists under the floating structure, there is seldom effect in natural environment. Fuertherrnore, it can do easily to do assembly and taking to pieces due to expansion or removal. Based on the regulation by class, VLFS have to possess more than enough structural strength against severe wave loading induced by green sea condition Therefore, There are performed structural simulation as well as experimental test about expected loading scenario in order to examine the safety of structure. Up to now, various examinations based on the strength limit value of the main structural material have been done based on the elasticity response analysis. However, there is little finding about the collapse behavior and the safety when the load that exceeds the collapse of the material acts. In the present study, we investigated the collapse behavior based on the ultimate limit state calculated by FE-analysis.

Development of PBL Package - focusing on dental hygienist roles - (치과위생사 역할중심의 문제중심학습 패키지 개발)

  • Jung, Young-Ran;Hwang, Yoon-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.119-132
    • /
    • 2004
  • The purpose of this study was to introduce PBL to dental hygienist education in an effort to raise a question about the inauthentic and inappropriate curriculum. PBL is one of learning methods to enhance the problem-solving ability of learners, and it's attempted to develop a PBL package focusing on dental hygienist roles to lay the foundation for producing competent and expert dental hygienists with a good problem- solving ability. The literature concerned was reviewed from November 2002 through January 2003 to determine whether or not PBL was applicable to dental-hygienist course, and that turned out to be effective for dental hygienist education. And then a PBL package was developed to train students to be knowledgeable and have a knowhow and excellent problem-solving skills. The characteristics of the PBL package could be described as follows: First, that focused on dental hygienist roles to serve the purpose of this study to remedy the current unrealistic and improper curriculum and improve the problem-solving skills of learners. Second, time factor was taken into account. In this four-week course for two credits, there are four classes a week, and it's required to take six or eight weeks to apply the PBL package, which is expected to demotivate students. Therefore, it's planned to conduct more weekly classes to make a proper progress. Third, a wide variety of teaching aids were put to use, and learner would be encouraged to be more interactive and utilize teaching aids properly, and eventually, they could have an opportunity to better express themselves. Fourth, online real-time learner discussion would be attended by this researcher. Learners would have a discussion in real time in the Internet cafe chat room, and different discussion time would be allocated to each team. This researcher would take part in each team's discussion once or more. Fifth, learners would prepare one or more journal(s) about four-hour Internet cafe learning. They have to make it twice a week at least, and it would be a good opportunity for learners to look back on themselves and their teams, and their learning effect would be greater. Specific rules were presented to help them make a successful self-examination. Sixth, there are some spaces in the lower part of objective test sheets to have students describe why they make a particular answer choice. They would be asked to depict the reason of their prior evaluation and lecture assessment especially because their responses would be important for more successful discussion and feedback. Seventh, problem-solving approach was designed to attain learning objectives, stimulate the creative thinking of learners and help them share a more systematic discussion. That would serve as a secondhand guide not to make them digress when they discuss by using information they acquire from a scenario presented in class.

  • PDF

A Context Free Grammar based Algorithm for Generating Playable Transcoding Paths of the Multimedia Presentation with Different End-to-End QoS (종단간 상이한 QoS를 갖는 멀티미디어 연출 재생을 위한 CFG 기반의 변환 경로 생성 알고리즘)

  • Chon, Sung-Mi;Lim, Young-Hwan
    • The KIPS Transactions:PartC
    • /
    • v.9C no.5
    • /
    • pp.699-708
    • /
    • 2002
  • Since various terminals and different networks get involved in playing of a multimedia presentation, the case that the presentation QoS at a destination should be different from the QoS of multimedia data at a source occurs frequently. For playing the multimedia presentation, the multimedia data at a source should be transcoded into the multimedia data satisfying the QoS required at the terminal. The problem of generating the transcoding path is that, for a given multimedia presentation, different transcoding paths depending the terminal and networks should be generated. That is, a fixed transcoding path cannot be applied to a multimedia presentation. Instead, whenever the terminal and network to play the presentation get determined, a proper transcoding path should be regenerated automatically. In this paper, the algorithm for generating the transcoding path and the method for checking the playability of the generated path are proposed. The generating algorithm adopted the technique of Context Free Grammar in describing the set of transcoding resources and a user's transcoding rules in order to utilize the well-known compiler techniques. For the playability check, a method of computing the transcoding time and the delay time between data units are proposed. Finally all the proposed methods were implemented in the stream engine, called Transcore and the presentation-authoring tool, called VIP, we had developed. And the test results with a sample scenario were presented at the last.

A Study on Fire Resistance and Spalling of HPC Beam with Fiber-Cocktail in ISO Fire under Loading Condition (표준화재 재하조건하에서 Fiber Cocktail을 혼입한 고강도 콘크리트 보의 폭렬특성 및 내화성능에 관한 연구)

  • Cho, Kyung-Suk;Kim, Heung-Youl;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.126-134
    • /
    • 2009
  • In an attempt to control the spalling in high strength concrete, spalling reducer was mixed to identify the effect and thermal characteristics of concrete beam member at high temperature. The member was manufactured in such as way of adding 40~60MPa of high strength concrete into spalling reducer, and then fire resistance performance were monitored under the ISO standard fire load condition in accordance with KS F 2257. As a result of test, fore rate performance of 40MPa beam without spalling reducer was 180minutes, 50MPa was 174minutes and 60MPa was 152minutes, indicating that 50MPa and 60MPa beam appeared 6~28minutes short to become a 3-hour rate. However, 50 and 60MPa beam mixed with spalling reducer appeared to have satisfied the requirements for 180minutes. A spalling was occurred in surface of 50 and 60MPa beam mixed without spalling reducer, while no spalling or surface failure was occurred with 50 and 60MPa beam mixed with spalling reducer. Thus polypropylene fiber mixed with the concrete proved to be effective, but viewing that the surface of 60MPa was peeled off partially, the steel fiber mixed appeared not to be effective for the beam more than 60MPa.

A Riverbed Change Prediction by River-Crossing Structure -Focused on the Major River Reaches of the Multifunctional Administrative City- (하천 횡단구조물에 의한 하상변동 예측 - 행정중심복합도시 주요 하천구간을 중심으로 -)

  • Yeon, Kyu-Sung;Jeong, Sang-Man;Yun, Chan-Young;Lee, Joo-Heon;Shin, Kwang-Seob
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.107-113
    • /
    • 2009
  • This study has been conducted for the long-term riverbed change prediction on Geum River and Miho Stream surrounding the planned Multifunctional Administrative City and the neighboring regions by the construction of a small dam. Based on the analysis of vertical riverbed changes of the cross-sectional data for the years 1988, 2002 and 2007, minimum bed elevation significantly decreased in both Geum River and Miho Stream in 2007 as compared to 1988. Compared to 2002, however, a slight elevation change was observed. To make a long-term prediction on riverbed changes by the construction of a small dam, a one dimensional HEC-RAS 4.0 model has been used. By the fixed bed model test, the water levels were calibrated. By using the cross-sectional data of 1988 and 2002, verification was conducted under a movable bed model. According to the prediction of riverbed changes for each scenario with varying height of small dam, minor impact is expected around Miho Stream while major impact is expected around Geum River by 2017, as the small dam height increases. If the small dam is 7m-high, for example, it's been simulated that 1.59m deposition would be expected around the upper stream of Miho Stream Confluence while 1.98m scour would be expected around the downstream of the small dam.

Current Calculation Simulation Model for Smartgrid-based Energy Distribution System Operation (스마트 그리드 기반 에너지 시스템 운영을 위한 배전계통 조류계산 시뮬레이션 모델 개발)

  • Bae, HeeSun;Shin, Seungjae;Moon, Il-Chul;Bae, Jang Won
    • Journal of the Korea Society for Simulation
    • /
    • v.30 no.1
    • /
    • pp.113-126
    • /
    • 2021
  • The future energy consumption pattern will show a very different pattern from the present due to the increase of distributed power sources such as renewable energy and the birth of the concept of prosumers, etc. Accordingly, it can be predicted that the direction of establishment of an appropriate production and supply plan considering the stability and consumption efficiency of the entire power grid will also be different from now. This paper proposes a simulation model that can test a new operational strategy when faced with a number of possible future environments. Through the proposed model, it is possible to simulate and analyze power consumed and supplied in a future Smart Grid environment, in which a large amount of new concepts including energy storage service (ESS) and distributed energy resources (DER) will be added. In particular, it is possible to model complex systems structurally by using DEVS formalism among the ABM (Agent-Based Model) methodologies that can model decision-making for each agent existing in the grid, and several factors can be easily added to the grid. The simulation model was verified using given dataset in the current situation, and scenario analysis was performed by simply adding an ESS, one of the main elements of the smart grid, to the model.

Evaluation of Segment Lining Fire Resistance Based on PP Fiber Dosage and Air Contents (세그먼트 라이닝의 PP섬유 혼입량과 공기량 변화에 따른 화재저항 특성 평가)

  • Choi, Soon-Wook;Kang, Tae Sung
    • Tunnel and Underground Space
    • /
    • v.31 no.6
    • /
    • pp.469-479
    • /
    • 2021
  • As a material for preventing spalling of concrete, the effectiveness of PP fiber has already been confirmed. However, it is necessary to consider the maximum temperature that occurs during a fire, and to solve the mixing problem and the strength reduction problem that occur depending on the mixing amount. In this study, the fire resistance performance of tunnel segment linings according to the PP fiber content and air volume under the RABT fire scenario was investigated. As a result, no spalling or cross-sectional loss occurred in all test specimens, and when the PP fiber content was small, the maximum temperature was relatively high and the maximum temperature arrival time was also fast. On the other hand, no trend was found for the maximum temperature and arrival time according to the difference in air volume. In the internal temperature distribution results for the PP fiber mixing amount of 0.75, 1.0, 1.5, and 2.0 kg/m3, the results of 0.75 and 1.0 kg/m3 showed similar temperature distribution, and the results of 1.5 and 2.0 kg/m3 were similar. It was confirmed that the internal temperature distribution tends to decrease at the same depth when the amount of PP fiber mixed is large, and it was confirmed that a remarkable difference occurred from the results of 1.0 kg/m3 and 1.5 kg/m3 of PP fiber mixed amounts.