• Title/Summary/Keyword: Test lamp

Search Result 218, Processing Time 0.022 seconds

A study on the removing of contaminants by TiO2 coating and CaO additive (TiO2 코팅과 CaO 첨가에 따른 독성물질 제거에 관한 연구)

  • Woo, Insung;Lee, Geonduk;Hwang, Myungwhan;Lee, Hongju
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.3
    • /
    • pp.127-132
    • /
    • 2013
  • This study shows an air-purification test by the UV lamp on which TiO2 catalyst is deposited with glass fiber in the reactor chamber. This test was based on the fundamental data of air-purifier as assessing a removing ability on various contaminants such as CH3COOH, NH3, NO and SO2 as variation of the TiO2 coating, the wave of UV lamp, and the additive CaO. As a result, the highest decomposing removal ratio was shown when 5-times coated glass fiber was used. It can be due to the recombination reaction of electrons and electron-hole in the loaded CaO. Thus, the decomposing removal ratio increased as the recombination ratio decreased. In addition, it was confirmed that the decomposing removal ratio lowered when CaO was considerably deposited because it hided the lamp of OH-1 radical.

The Optimum Design According to Type Analysis of the Safety Circuit Design (LED 조명의 안전회로설계 Type분석에 따른 최적설계)

  • Jang, In-Hyeok;Kim, Jeong-Ho;Lim, Hong-Woo;Oh, Geun-Tae;Choi, Youn-Ok
    • Journal of Applied Reliability
    • /
    • v.16 no.4
    • /
    • pp.331-337
    • /
    • 2016
  • Purpose: The purpose of this study is the analysis of the failure mechanisms effect of circuit design characteristics of the ballast for LED Lamp Methods: Recently, electronic circuit of ballasts for LED lamp are being occurred on various failure mechanisms (whiskers, ion migration, heat dissipation problem, switching element damage) because electronic ballast circuit design characteristics are becoming more and more diverse. Results: we analysis failure mechanisms that occurs in accordance with the circuit design characteristics The ballast for LED lamp were divided into three different types (Type A, Type B, Type C) considering circuit design characteristics (thermal design, PCB patten spacing, element material) and it was experimented in the acceleration test conditions ($85^{\circ}C$, 85% R.H). Conclusion: We confirmed that failure mechanism of the ballast for LED Lamp had occurred differently in accordance with the circuit design characteristics.

Development of loop-mediated isothermal amplification method for the rapid and sensitive detection of bovine tuberculosis in Korea native cattle (한우 결핵의 신속 감별진단을 위한 등온증폭법 개발)

  • Hwang, Eun-Suk;Lee, Tae-Uk;Jung, Dae-Young;Cho, Ho-Seong
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.4
    • /
    • pp.333-339
    • /
    • 2011
  • Loop-mediated isothermal amplification (LAMP) was developed to detect Mycobacterium tuberculosis complex (MTC) and non-tuberculous mycobacterium (NTM) genomic DNA in blood samples of Korea native cattle. A set of four primers, two outer and two inner, were designed from M. bovis and M. avium genomic DNA targeting the IS6110 and 16S rRNA gene, respectively. Based on 85 Intradermal Tuberculin Test (ITT) positive blood sample and using conventional PCR and LAMP, the agreement quotient (kappa), which measures agreement beyond chance were 0.93 (conventional PCR) and 0.97 (LAMP), respectively. The detection limit of the LAMP method was $2.0{\times}10^2$ copy/ml M. bovis and M. avium cells, compared to $2.0{\times}10^3$ copy/ml M. bovis and M. avium cells for conventional PCR. These results suggest that the LAMP is a powerful tool for rapid, sensitive, and practical detection of MTC and NTM in blood samples of Korea native cattle.

Study on the Performance of Infrared Thermal Imaging Light Source for Detection of Impact Defects in CFRP Composite Sandwich Panels

  • Park, Hee-Sang;Choi, Man-Yong;Kwon, Koo-Ahn;Park, Jeong-Hak;Choi, Won-Jae;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.91-98
    • /
    • 2017
  • Recently, composite materials have been mainly used in the main wings, ailerons, and fuselages of aircraft and rotor blades of helicopters. Composite materials used in rapid moving structures are subject to impact by hail, lightning, and bird strike. Such an impact can destroy fiber tissues in the composite materials as well as deform the composite materials, resulting in various problems such as weakened rigidity of the composite structure and penetration of water into tiny cracks. In this study, experiments were conducted using a 2 kW halogen lamp which is most frequently used as a light source, a 2 kW near-infrared lamp, which is used for heating to a high temperature, and a 6 kW xenon flash lamp which emits a large amount of energy for a moment. CFRP composite sandwich panels using Nomex honeycomb core were used as the specimens. Experiments were carried out under impact damages of 1, 4 and 8 J. It was found that the detection of defects was fast when the xenon flash lamp was used. The detection of damaged regions was excellent when the halogen lamp was used. Furthermore, the near-infrared lamp is an effective technology for showing the surface of a test object.

Development of reverse transcription loop-mediated isothermal amplification assays for point-of-care testing of avian influenza virus subtype H5 and H9

  • Zhang, Songzi;Shin, Juyoun;Shin, Sun;Chung, Yeun-Jun
    • Genomics & Informatics
    • /
    • v.18 no.4
    • /
    • pp.40.1-40.8
    • /
    • 2020
  • Avian influenza (AIV) outbreaks can induce fatal human pulmonary infections in addition to economic losses to the poultry industry. In this study, we aimed to develop a rapid and sensitive point-of-care AIV test using loop-mediated isothermal amplification (LAMP) technology. We designed three sets of reverse transcription LAMP (RT-LAMP) primers targeting the matrix (M) and hemagglutinin (HA) genes of the H5 and H9 subtypes. RT-LAMP targeting the universal M gene was designed to screen for the presence of AIV and RT-LAMP assays targeting H5-HA and H9-HA were designed to discriminate between the H5 and H9 subtypes. All three RT-LAMP assays showed specific amplification results without nonspecific reactions. In terms of sensitivity, the detection limits of our RT-LAMP assays were 100 to 1,000 RNA copies per reaction, which were 10 times more sensitive than the detection limits of the reference reverse-transcription polymerase chain reaction (RT-PCR) (1,000 to 10,000 RNA copies per reaction). The reaction time of our RT-LAMP assays was less than 30 min, which was approximately four times quicker than that of conventional RT-PCR. Altogether, these assays successfully detected the existence of AIV and discriminated between the H5 or H9 subtypes with higher sensitivity and less time than the conventional RT-PCR assay.

Study of the Reflector Shape of a Test Lamp for a Flame Detector with Little Influence of Error in Optical-system Fabrication (광학계 제작 시 오차 영향이 적은 불꽃감지기용 테스트램프 반사경 형상에 관한 연구)

  • Park, Hye-Jin;Kang, Dong-Hwa;Kong, Mi-Seon;Kim, Eun-Ji;Lee, Ye-Eun;Jo, Ye-Ji;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.6
    • /
    • pp.233-240
    • /
    • 2018
  • In this paper, a design method to reduce fabrication errors in reflector shape of a test lamp for a flame detector is carried out. Although the test lamp should be operated in parallel with a high-intensity light, it is difficult to fix the small reflector that controls the central light during fabrication. To solve these problems, a small spherical reflector is designed to minimize the performance degradation for a light loss factor of less than 5%, even during tilt and decenter, and a spherical shape is proposed for a small reflector with little effect on the error when designing the optical system.

LED Street Light Lamp Control by Central Command System (중앙관제시스템에 의한 LED 도로조명제어)

  • Cho, Si-Hyeong;Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.30 no.B
    • /
    • pp.75-81
    • /
    • 2010
  • This paper presents the development of LED street light lamp which is controled by central command system. This system includes a lamp unit controller, data repeater and command repeater as well as the LED lamps. These devices enable the individual power control and partial on/off control of the LED lamps by the control repeater through full duplex communication line. Also, they have the ability to control the brightness and period of on/off timing by detecting the car's existence. As a result of this development, it is founded that the performances of the system have been satisfied to apply for the actual road test.

  • PDF

A Test of the Aviation Obstacle Light and Structural Improvement (태양전지식 항공장애등 성능특성시험 및 구조개선)

  • Byun, Gang;Min, Byeong-Wook;Kim, Sae-Hyun;Lee, Dong-Il;Shin, Gu-Yong;Lee, Sung-Doo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.442-444
    • /
    • 2003
  • For the safety of aircraft, aviation obstacle lights must be attached to the transmission towers in accordance with the governing law. Aviation obstacle lights which consist of solar cells, batteries. xenon lamps and a regulator substituted for aviation obstacle lights using AC power. A xenon lamp has advantage such as high brightness but also has disadvantage like large power consumption which cause lighting system to have many solar cells and batteries. This paper introduces an application of a aviation obstacle light using LED lamp through the economic analysis between LED lamp and xenon lamp.

  • PDF

The Effects of Temperature and Light on the Quality Change of Oils and Fats (유지의 품질변화에 미치는 온도 및 광선의 영향)

  • Lee, Ki-Chang;Yang, Chun-Hoi;Choi, Bong-Jong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.63-67
    • /
    • 1985
  • AOM and lamp tests were carried out with soybean, corn, palm oil and beef tallow without the addition of antioxidant. The evaluation of rancidity for the stability was determined by changes of peroxide value and acid value, and the correlation between the stability and the composition of fats and oils was examined. The results obtained were as follows. 1. In the AOM test, POV began to rise in the order of corn oil, soybean oil, beef tallow and palm oil. However, the time required to reach POV 100 in beef tallow was faster than other fats and oils. It was found that there was a good correlation between POV and content of tocophrol. 2. In the lamp test by light of main wavelength 253.7nm, beef tallow was stabler than soybean and corn oil. It was because the absorption of light into beef tallow was much smaller than others, since beef tallow was fats. Palm oil was very stable in all the samples during AOM and lamp test.

An Effect of Carbon Arc Lamp and Low Level Laser Therapy on the Changes of Burned Mice's Cytokine (탄소방전등과 저강도 레이저 조사가 화상 쥐의 Cytokine 변화에 미치는 영향)

  • Park, Don-Mog;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.6
    • /
    • pp.13-21
    • /
    • 2006
  • Purpose: To provide the basic method for physical therapy to contribute to early stage treatment of a burned patients. We investigated whether or not carbon arc lamp treatment and low level laser one among various laser treatments have the effect of reducing Cytokine, and to elucidate the effect of carbon arc lamp treatment and laser one. Methods: The 6-week old BALB/c types of 92 mice were used for the experimental test, and they were burned with $100^{\circ}C$ water, they were divided into 4 groups in accordance with the method of treatment respectively. And the blood and the tissue from the subject of each group were extracted and analyzed each time after they were cured for 3, 6, 9 days. For the analysis of the results, SPSS statistical program was used in this study. Results: The quantity of $TNF-{\alpha}$ and $IL-1{\beta}$ within the blood of a burned mouse increased more than that of a normal mouse(p<0.01). In only a burned mouse, carbon arc lamp treatment gave the effect on the decrease of $TNF-{\alpha}$ thickness the 6th day to the 9th day(p<0.01). $IL-1{\beta}$ quantity was more decreased than that of control group around the 6th day. In comparison with only a control group, low level laser treatment has more significant effect in decreasing the quantity of $TNF-{\alpha}$ a and $IL-1{\beta}$ than the two different methods(p<0.01). In case that the two treatment methods, carbon arc lamp treatment and low level laser, were executed together, there was the effect of decreasing $TNF-{\alpha}$ until the 6th day(p<0.01). Conclusion: Both low level laser treatment and carbon arc lamp one would be able to have an effect on the inflammation inhibition of burned patients and tissues reproduction. However, it must be also considered for the two treatments to be done at the same time.

  • PDF