• Title/Summary/Keyword: Test lamp

Search Result 218, Processing Time 0.028 seconds

Experimental study on Light and Gas Pollution Resistance of Commercial Natural Pigments for Dancheong - Focucing on Korea, Japan and China Products - (시판 단청용 천연안료의 내광성·내공해성 실험 연구 -한국, 일본, 중국 생산 안료를 중심으로-)

  • Lee, Kyeong Min;Kim, Soon Kwan;Bae, Su Bin;Kim, Mi Jeong
    • Journal of Conservation Science
    • /
    • v.31 no.4
    • /
    • pp.443-455
    • /
    • 2015
  • To verifying the stability of Natural pigments for Dancheong which is available on the market was carried out as light resistance and gas corrosion test. In this particular case, we will confirm the characteristics of the only pigments except of Dancheong technique and influence of substance. Medium using for coloring are animal glue and synthetic resin that widely used for Dancheong in currently. Selected to artificial light source is a xenon arc lamp, contaminated gas is nitrogen dioxide gas in experiment. Degree of degradation of pigment were compared by measuring the degree of color change. The result of light resistance test, mineral pigments were good; color is green and blue type, soil pigments also good; color is yellow ocher, white clay, red clay etc. Gamboge, unghwang, cinnabar, red lead were confirmed not good. The result of gas corrosion test, most of the natural pigments were good condition except the red lead. Generally, animal glue samples had better than a synthetic resin samples.

Investigation of Lateral Resistance of Short Pile by Large-Scale Load Tests (실물 재하시험을 통한 짧은말뚝의 횡방향 저항거동 평가)

  • Lee, Su-Hyung;Choi, Yeong-Tae;Lee, Il-Wha;Yoo, Min-Taek
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.8
    • /
    • pp.5-16
    • /
    • 2017
  • When a lateral load is applied to a short pile whose embedded depth is relatively smaller than its diameter, an overturning failure occurs. To investigate the behavior of laterally loaded short piles, several model tests in laboratory scales had been carried out, however the behavior of large moment carrying piles for electric poles, traffic sign and road lamp, etc. have not been revealed yet. This paper deals with the real-scale load tests for 750 mm diameter short piles. To simulate the actual loading condition, very large moment was mobilized by applying lateral loads to the location 8 m away from the pile head. Three load tests changing the pile embedded lengths to 2.0 m, 2.5 m, and 3.0 m were carried out. The test piles overturned abruptly with very small displacement and rotation before the failures. These brittle failures are in contrast with the ductile failures shown in the former model tests with the relatively smaller moment to lateral load ratio. Comparisons of the test results with three existing methods for the estimation of the ultimate lateral capacity show that the method assuming the rotation point at pile tip matches well when the embedded depth is small, however, as the embedded depth increases the other two methods assuming the inversion of soil pressure with respect to rotation points in pile length match better.

Chemical Modification and Functionalisation of Poly(ethylene terephthalate) Fiber (폴리에틸렌테레프탈레이트 섬유의 화학개질 및 기능화)

  • 김인회;김성희
    • Polymer(Korea)
    • /
    • v.26 no.3
    • /
    • pp.389-399
    • /
    • 2002
  • Poly (ethylene terephthalate) (PET) fibers were modified by deep UV irradiation which was produced by a low pressure mercury lamp. FT-IR and XPS analyses were used to elucidate the surface chemical composition of PET fibers treated with UV. Relative $O_{1s}$ intensity increased considerably and it was found that oxygen was incorporated in the form of COO on the fiber surface. FT-IR and XPS analyses proved the existence of carboxylic groups on the surfaces and the adsorption test of cationic compound further supported these results. The concentration of carboxylic acid group on the surface increased remarkably with Increasing irradiation time. XPS analysis and adsorption experiments proved that the surface structure of the UV-irradiated PET fibers were stable for 12 months. Antibacterial property and the deodorization rate of UV-irradiated PET fibers adsorbed with the berberine compound were investigated. Reduction rates of bacteria increased by about 21 to 99% compared to unradiated PET fiber. Deodorization rates of 23% for unradiated PET fiber increased to about 75% for 30 min irradiated samples.s.

The study on the Anchovy's (Engraulis japonica) reaction to several light colors in a tank (수조에서 여러 가지 색광에 대한 멸치의 반응 연구)

  • Bae, Bong-Seong;Cho, Sam-Kwang;Cha, Bong-Jin;Park, Seong-Wook;An, Heui-Chun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.47 no.4
    • /
    • pp.327-337
    • /
    • 2011
  • This study was conducted to develop energy-efficient LED lamps with an excellent fishing performance for an anchovy scoop net by comparing the functions of 6 different lamps- incandescent, blue LED, green LED, white LED, yellow LED and red LED lamp. We used incandescent and red LED lamps only for the initial test and then excluded because those showed the lowest herding capacity. According to the result, yellow LED showed lower herding capacity in comparison with the blue, green and white one. Although the herding performance of the blue, green and white LED was similar in almost tests, herding speed to the each light was different. The anchovies were gathered into the blue LED as the speed of 39.88cm/s that was the fastest. Green LED was the second as the speed of 33.28cm/s. White LED was the slowest as the speed of 26.73cm/s. We will have field tests because we found the result that yellow LED's herding performance was better than green LED's for 5 seconds comparing after starting in some tests.

Monitoring of Environmental Arsenic by Cultures of the Photosynthetic Bacterial Sensor Illuminated with a Near-Infrared Light Emitting Diode Array

  • Maeda, Isamu;Sakurai, Hirokazu;Yoshida, Kazuyuki;Siddiki, Mohammad Shohel Rana;Shimizu, Tokuo;Fukami, Motohiro;Ueda, Shunsaku
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.12
    • /
    • pp.1306-1311
    • /
    • 2011
  • Recombinant Rhodopseudomonas palustris, harboring the carotenoid-metabolizing gene crtI (CrtIBS), and whose color changes from greenish yellow to red in response to inorganic As(III), was cultured in transparent microplate wells illuminated with a light emitting diode (LED) array. The cells were seen to grow better under near-infrared light, when compared with cells illuminated with blue or green LEDs. The absorbance ratio of 525 to 425 nm after cultivation for 24 h, which reflects red carotenoid accumulation, increased with an increase in As(III) concentrations. The detection limit of cultures illuminated with near-infrared LED was 5 ${\mu}g$/l, which was equivalent to that of cultures in test tubes illuminated with an incandescent lamp. A near-infrared LED array, in combination with a microplate, enabled the simultaneous handling of multiple cultures, including CrtIBS and a control strain, for normalization by the illumination of those with equal photon flux densities. Thus, the introduction of a near-infrared LED array to the assay is advantageous for the monitoring of arsenic in natural water samples that may contain a number of unknown factors and, therefore, need normalization of the reporter event.

Congenital Anomalies of Lower Lacrimal Puncta and Nasolacrimal Duct Atresia in a Labrador Retriever Dog

  • Park, Eun-Jin;Kang, Seon-Mi;Park, Sang-Wan;Kwak, Ji-Yoon;Lim, Jae-Gook;Nam, Taek-Jin;Jeong, Seo-Woo;Seo, Kangmoon
    • Journal of Veterinary Clinics
    • /
    • v.33 no.4
    • /
    • pp.228-230
    • /
    • 2016
  • An 1-year-old, spayed, female Labrador Retriever was presented for bilateral epiphora. A complete ophthalmic examination was conducted, including Schirmer tear test, rebound tonometry, fluorescein staining, slit lamp biomicroscopy, and binocular indirect ophthalmoscopy. To determine the patency of the nasolacrimal duct system, a nasolacrimal flush and dacryocystorhinography were also performed. Although the nasolacrimal flush showed patency in the upper and lower lacrimal puncta in both eyes (OU), the lower lacrimal puncta were not found in the original palpebral conjunctiva, but on medial canthal skin with very small opening. Moreover, the nasolacrimal ducts in OU were not patent with flushing. Bilateral nasolacrimal duct atresia was confirmed by dacryocystorhinography. No other abnormalities of the eyes were found on complete ophthalmic examinations. Bilateral congenital anomalies of the lower lacrimal puncta and nasolacrimal duct atresia were diagnosed in this dog.

Effect of Injection Conditions on the Spray Behaviors of the Multi-hole GDI Injector (분사 조건이 다공형 GDI 인젝터의 분무 거동에 미치는 영향)

  • Park, Jeong-Hwan;Park, Su-Han;Lee, Chang-Sik;Park, Sung-Wook
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.2
    • /
    • pp.116-122
    • /
    • 2012
  • The purpose of this study is to investigate the overall spray behavior characteristics for various injection conditions in a gasoline direct injection(GDI) injector with multi-hole. The spray characteristics, such as the spray penetration, the spray angle, and the injection quantity, were studied through the change of the injection pressure, the ambient pressure, and the energizing duration in a high-pressure chamber with a constant volume. The n-heptane with 99.5% purity was used as the test fuel. In a constant volume chamber, the injected spray was visualized by the spray visualization system, which consisted of the high-speed camera, the metal-halide lamp, the injector control device, and the image analysis system with the image processing program. It was revealed that the injection quantity was mainly affected by the difference between the injection pressure and the ambient pressure. For low injection pressure conditions, the injection quantity was decreased by the increase of the ambient pressure, while it nearly maintained regardless of the ambient pressure at high injection pressure. According to the increase of the ambient pressure in the constant volume chamber, the spray development became slow, consequently, the spray tip penetration decreased, and the spray area increased. In additions, the circular cone area decreased, and the vortex area increased.

The Effect of Periocular Acupressure with a Medical Massager for Myopia Children

  • Cha, Ho-Yeol;Jung, A-Ram;Kang, Byoung-kab;Song, Ji-Hoon;Jung, Jae Ho;Cheon, Jin Hong;Choi, Jun Yong;Kim, Kibong
    • The Journal of Korean Medicine
    • /
    • v.37 no.2
    • /
    • pp.53-61
    • /
    • 2016
  • Objectives: Considering high prevalence of myopia in Asian countries, social cost paid for myopia may gradually increase in Korea. However, studies for developing myopia treatment are deficient. The study was to evaluate whether the periocular acupressure with a medical massager is effective for suppressing myopia progression. Methods: This study was an investigator-sponsored, prospective, open-labeled, and superiority pre and post single-armed study. 14 myopia children aged 7-12 years wore a medical massager for 15 minutes to stimulate periocular acupoints. For 24 weeks, the participants used the device twice a day. Based on prior studies, the refraction change of naturally proceeded myopia was set as -0.38 D. The axial length change of naturally proceeded myopia was set as 0.228 mm. To assess the safety, we performed vital sign check, physical examination, visual acuity test, slit lamp examination, IOP measurement, and fundus examination. Results: The refraction and axial length of the participants increased. For 24 weeks, the change in refraction was -0.38 D at the right eye and -0.40 D at the left. The change in axial length was 0.21 mm at the right and 0.22 mm at the left. In the safety assessment, any adverse event did not occur. Conclusions: There was no significant difference between the control group and the intervention group. The effect of growth may have more contributed to our result than that of acupressure. Based on our result, a full-scale study will not be conducted.

First Light Results of IGRINS Instrument Control Software

  • Lee, Hye-In;Pak, Soojong;Sim, Chae Kyung;Le, Huynh Anh N.;Jeong, Ueejeong;Chun, Moo-Young;Park, Chan;Yuk, In-Soo;Kim, Kangmin;Pavel, Michael;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.54.2-54.2
    • /
    • 2014
  • IGRINS (Immersion GRating Infrared Spectrograph) is a high spectral resolution near-infrared spectrograph that has been developed in a collaboration between the Korea Astronomy & Space Science Institute and the University of Texas at Austin. By using a silicon immersion echelle grating, the size of the fore optics is reduced by a factor of three times and we can make a more compact instrument. One exposure covers the whole of the H- and K-band spectrum with R=40,000. While the operation of and data reduction for this instrument is relatively simple compared to other grating spectrographs, we still need to operate three infrared arrays, cryostat sensors, calibration lamp units, and the telescope during astronomical observations. The IGRINS Instrument Control Software consists of a Housekeeping Package (HKP), Slit Camera Package (SCP), Data Taking Package (DTP), and Quick Look Package (QLP). The SCP will do auto guiding using a center finding algorithm. The DTP will take the echellogram images of the H and K bands, and the QLP will confirm fast processing of data. We will have a commissioning observations in 2014 March. In this poster, we present the performance of the software during the test observations.

  • PDF

Familial Sarcoidosis, The First Report in Korea (가족형 폐유육종증)

  • Uhm, Wan-Sik;Lim, Chae-Man;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.6
    • /
    • pp.644-650
    • /
    • 1994
  • Sarcoidosis can affect two or more members of the same family, and the reported occurrence of such familial sarcoidosis is variable from 0.5 to 14%. Recent1y we have experienced familial sarcoidosis affected mother and daughter, for the first time in Korea. Mother was diagnosed as Stage 11 sarcoidosis 4 years ago by transbronchial lung biopsy and cervical lymph node biopsy with compatible BAL finding in our hospital. This time, the daughter was admitted with bilateral hilar enlargement and anterior uveitis. Even though she had positive tuberculin skin test and atypical BAL finding(lymphocyte: 61%, CD4/CD8: 1.22). Transbronchial lung biopsy and mediastinal lymph node biopsy revealed noncaseating epithelioid granuloma without AFB. Slit lamp examination of the eyes showed severe anterior uveitis. Systemic steroid therapy was started due to progressive uveitis with antituberculous medication.

  • PDF